• Title/Summary/Keyword: Conventional Suture

Search Result 71, Processing Time 0.028 seconds

Convenient Suture Technique for Pediatric Facial Lacerations (소아 안면열상 환자의 치료에 있어서 유용한 봉합술)

  • Kim, Jun-Hyung;Kwon, Soon-Beom;Eo, Su-Rak;Cho, Sang-Hun;Markowitz, Bernard L.
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.496-498
    • /
    • 2010
  • Purpose: Lacerations requiring formal wound closure compose a significant number of all childhood injuries presenting to the emergency department. The problem with conventional suture technique are that suture removal is quite cumbersome, especially in children. Unwanted soft tissue damage can result in the process of suture removal, which calls for sedation, stressful for both medical personnel and child. The purpose of this study is to introduce the convenient suture technique for pediatric facial lacerations. Methods: Children under the age of four, presenting to the emergency department with facial lacerations were enrolled in the study. From March 2008 to June 2009, 63 patients (41 males and 22 females) with an average age of 1.4 years were treated with our convenient suture technique using utilized a loop suspended above a double, flat tie. Clean, tension free wounds were treated with our technique, wounds with significant skin defect and concomitant fractures were excluded. Results: The Patients were followed-up in 1, 3 and 5 days postoperatively. On the third hospital visit, suture removal was done by simply cutting the loop suspended above the wound margin and gently pulling the thread with forceps. There were no significant differences in the rates of infection and dehiscence compared with conventional suture technique. Conclusion: The use of our technique was to be simple with similar operative time compared with conventional suture technique. Removal of suture materials were easy without unwanted injuries to the surrounding tissue which resulted in less discomfort for the patient and greater parental satisfaction, minimized the complications. It can be considered as a viable alternative in the repair of pediatric facial lacerations.

Comparing Conventional Suture Method Versus Wound Closure Using Tissue Glue(Histoacryl Blue®): a Prospective Randomized Clinical Trial (기존의 창상봉합과 Histoacryl Blue®를 이용한 창상봉합의 비교 분석: 전향적 무작위 임상실험)

  • Choi, Jong Woo;Hyun, Kyung Bae;Kim, Yong Oock;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.19-23
    • /
    • 2005
  • Tissue adhesives have gained popularity for quicker and painless closure of lacerations. The use of tissue glue is currently popular for the closure of superficial lacerations, especially in children. Histoacryl $Blue^{(R)}$(2-N-butylcyanoacrylate) is a topical wound closure that precludes the need for foreign bodies to close wounds. The purpose of this study was to compare the applications of Histoacryl $Blue^{(R)}$(HAB) and conventional suture, regarding cosmetic outcome. To compare the short term and long term results of various repair methods, we designed the prospective, randomized, blind study. Patients with laceration undergoing repair were randomly allocated to conventional suture, subcutaneous suture plus HAB, and HAB only groups. The exclusion criterions were large wound that require large tension for repair or avulsion wound. An independent, blinded observer assessed cosmetic result at 7-10 days after repair and 3-9 months postoperatively. Physician's satisfaction with wound appearance was recorded on 100 mm Visual Analogue Scale(VAS)(0=worst, 100=best). The difference in VAS score between conventional suture method and subcutaneous suture plus HAB methods were not significant. Tissue glue being easy to use with no complications and still resulting in equivalent cosmetic outcomes has several benefits. Especially in the case of children, the wound closure with Histoacryl $Blue^{(R)}$ could be a good alternative for repair of laceration in emergency room.

The hidden X suture: a technical note on a novel suture technique for alveolar ridge preservation

  • Park, Jung-Chul;Koo, Ki-Tae;Lim, Hyun-Chang
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.415-425
    • /
    • 2016
  • Purpose: The present study investigated the impact of 2 different suture techniques, the conventional crossed mattress suture (X suture) and the novel hidden X suture, for alveolar ridge preservation (ARP) with an open healing approach. Methods: This study was a prospective randomized controlled clinical trial. Fourteen patients requiring extraction of the maxillary or mandibular posterior teeth were enrolled and allocated into 2 groups. After extraction, demineralized bovine bone matrix mixed with 10% collagen (DBBM-C) was grafted and the socket was covered by porcine collagen membrane in a double-layer fashion. No attempt to obtain primary closure was made. The hidden X suture and conventional X suture techniques were performed in the test and control groups, respectively. Cone-beam computed tomographic (CBCT) images were taken immediately after the graft procedure and before implant surgery 4 months later. Additionally, the change in the mucogingival junction (MGJ) position was measured and was compared after extraction, after suturing, and 4 months after the operation. Results: All sites healed without any complications. Clinical evaluations showed that the MGJ line shifted to the lingual side immediately after the application of the X suture by $1.56{\pm}0.90mm$ in the control group, while the application of the hidden X suture rather pushed the MGJ line slightly to the buccal side by $0.25{\pm}0.66mm$. It was demonstrated that the amount of keratinized tissue (KT) preserved on the buccal side was significantly greater in the hidden X suture group 4 months after the procedure (P<0.05). Radiographic analysis showed that the hidden X suture had a significant effect in preserving horizontal width and minimizing vertical reduction in comparison to X suture (P<0.05). Conclusions: Our study provided clinical and radiographic verification of the efficacy of the hidden X suture in preserving the width of KT and the dimensions of the alveolar ridge after ARP.

ACTION POTENTIAL DIFFERENCES AND REGENERATION EFFECT AFTER MICRONEURAL SUTURE TECHNIQUE AND FIBRIN ADHESIVE TECHNIQUE IN RAT SCIATIC NERVE (신경문합술과 피브린접합술 후 활동전위차 및 신경재생 효과)

  • Jung, Tae-Young;Kim, Uk-Kyu;Chung, In-Kyo;Shin, Sang-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.5
    • /
    • pp.427-435
    • /
    • 2005
  • The purpose of this study was to compare clinical availability of fibrin adhesive technique with microneural suture technique. We applicated fibrin adhesive technique and microneural suture technique on cut sciatic nerve in rat and used to Compound muscle action potential of rat thigh muscle compartment and histologic finding for comparision of clinical availability. The results were as following. 1. Using latency and amplitude in Compound muscle action potential test, we compared microneural suture technique with fibrin adhesive technique for nerve regeneration effect. the means was slightly different between two method. but there's no statistically significant differences. 2. Histologic finding was similar in microneural suture technique and fibrin adhesive technique for regeneration of axon and myelin sheath in destruction site after nerve anastomosis. These results showed that the efficacy of fibrin adhesive technique was similar to that of conventional microneural suture technique. Moreover, fibrin adhesive technique is decreased operating time and imporved of incapability of accessment in conventional suture technique. Therefore this technique is a useful method to nerve anastomosis in nerve enervation and neurotransplantation.

Microvascular Anastomosis Using 'Continuous Suture with Interrupted Knot' Technique (연속 봉합 단속 결찰법을 이용한 미세 혈관 문합법)

  • Choi, Moon-Su;Park, Sang-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.22-27
    • /
    • 1999
  • While the conventional end-to-end anastomotic technique is accepted as 'the golden standard' for microvascular anastomosis, it is time-consuming and tedious. In an effort to offer faster and safer ways of performing microvascular anastomoses, numerous anastomotic techniques have been proposed, but further refinements in microvascular techniques are still necessary. A 'continuous suture with interrupted knot' technique was devised for faster and safer anastomosis. It has been successfully used in microanastomoses of both artery and vein for free tissue transfer. It is a combination of the interrupted suturing technique and the continuous suturing technique. First, a continuous suture is made with the size of loop decreasing in order, and then the sutures are tied individually from the first loop to the last one as in the conventional interrupted suturing technique. It was applied clinically to fourteen patients over the past ten months and found to be a highly efficient technique that satisfied our needs. This 'continuous suture with interrupted knot' technique has several advantages over other techniques : The operative time is reduced comparing conventional interrupted suture technique. By delaying the tie and with the vessel walls kept separated, the risk of through-stitch can be reduced. Tying all the sutures at one time not only speed up the procedures, but also reduced the surgeon's fatigue. In addition, it has no problem of anastomotic stenosis which is a disadvantage of continuous suture technique. This technique proved to be faster and safer, and has patency equal to that of the conventional end-to-end anastomosis. It is of great help to the surgeon in reducing operative time, especially in clinical situations when many anastomoses are required, or lengthy grafting procedures are undertaken.

  • PDF

Advantages of Scorpion Suture Passer and 70 Degrees Arthroscope in Arthroscopic Bankart Repair: Usefulness for Inferior Labral Repair

  • Hyun, Yoon-Suk;Shin, Woo-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • Background: The blunted tip of a reusable with multiple uses can cause problems with the passing procedure in arthroscopic Bankart repair. This study assessed the advantage of Scorpion with a $70^{\circ}$ arthroscope in arthroscopic Bankart repair compared to hook typed suture passer. Methods: Scorpion in 19 patients, the hook type suture passer (conventional group) in 18 patients were used. All patients underwent the same procedure except for the type of suture passer used. Another different point of the procedure were telescopes and the number of portals used; three arthroscopic portals (posterior, anterorsuperiorlateral, and mid-anterior) and a $30^{\circ}$ arthroscope in the conventional group, but two portals and a $70^{\circ}$ arthroscope as well as the $30^{\circ}$ one in the Scorpion group. The surgery time and the surgical complications including an iatrogenic axillary nerve injury were recorded. Results: The Scorpion group showed a significant decrease in surgery time compared to the conventional group. In contrast to the conventional group, Scorpion provided an easy estimation of the exit of suture passing, no iatrogenic labral injury during the passing procedure with straight movement and the sharp tip of the knife installed. Iatrogenic supraspinatus injuries could be avoided when making an accessory anteosuperiorlateral portal due to the $70^{\circ}$ arthroscope. Conclusions: In arthroscopic Bankart repair, the use of the Scorpion suture passer and a $70^{\circ}$ arthroscope can reduce the surgery time, avoid unnecessary supraspinatus injury, and avoid iatrogenic axillary nerve damage through the relatively easy and precise suture passing and saving of the anterosuperior portal.

Enhancing Venous Anastomosis Visualization in Murine Kidney Transplants: The Two Stay Suture Technique

  • Jong-Min Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.423-428
    • /
    • 2023
  • The mouse kidney transplantation model serves as an invaluable tool for exploring various aspects of the transplant process, including acute rejection, cellular and humoral rejection, ischemia-reperfusion injury, and the evaluation of novel therapeutic strategies. However, conducting venous anastomosis in this model poses a significant challenge due to the thin and pliable characteristics of the renal vein, which often obstruct clear visualization of the resected vein's edge. This study proposes the adoption of a two stay suture technique to enhance the visualization of the renal vein's edge, thereby facilitating efficient and successful venous anastomosis. A total of 22 mice served as kidney donors in this study. The conventional anchoring suture technique was employed for venous anastomosis in 11 of these mice, while the remaining 11 underwent the two stay suture technique. The anastomosis duration and completion rates were then compared between these two groups. The conventional anchoring suture technique yielded an average anastomosis time of 29 minutes and a completion rate of 64%. In contrast, the two stay suture technique demonstrated a substantial improvement, with an average anastomosis time of 14 minutes and a completion rate of 100%. The two stay suture technique offers a promising solution to enhance visualization during venous anastomosis in murine kidney transplantation. This technique may particularly benefit novices by enabling them to perform venous anastomosis more easily, swiftly, and successfully.

Cadaveric Feasibility Study of Knotless Barbed Suture for Tracheal Anastomosis in Dogs

  • Hyeon-Ah Min;Chang-Hwan Moon;You-Jeong Jeong;Hae-Beom Lee;Dae-Hyun Kim;Seong Mok Jeong
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.311-318
    • /
    • 2022
  • Appropriate suture technique is crucial for successful tracheal anastomosis. However, standards for an ideal suture method have not yet been established. A previous study suggested tracheal anastomosis using barbed sutures that do not require knots; however, their use in small animals has not been reported. In this study, we aimed to compare knotless barbed sutures with conventional smooth sutures in terms of maximum tensile strength and suturing time in canine tracheal models to demonstrate the feasibility of using barbed sutures in tracheal anastomosis in dogs. Tracheal segments harvested from nine beagle dog cadavers were randomly assigned to three suture groups: barbed suture (B), smooth suture in simple interrupted pattern (SI), and smooth suture in simple continuous pattern (SC). The maximum tensile force and suturing time were compared according to the suturing method, and the mode of failure was evaluated. The average suturing time was 3.29 min in the B group; 4.41 min, SC group; and 8.99 min, SI group (p < 0.001). The average maximum tensile force in the SC group was 134.97 N, which was stronger than the SI (110.57 N) and B groups (103.10 N) (p < 0.05 and p < 0.01, respectively). The difference between the B and SI groups was not significant (p = 0.05). The B group demonstrated comparable mechanical strength and shorter suture time compared with the SI group. Therefore, tracheal anastomosis using barbed sutures could be an effective alternative to conventional smooth sutures in dogs.

Barbed sutures versus conventional tenorrhaphy in flexor tendon repair: An ex vivo biomechanical analysis

  • Colak, Ozlem;Kankaya, Yuksel;Sungur, Nezih;Ozer, Kadri;Gursoy, Koray;Serbetci, Kemal;Kocer, Ugur
    • Archives of Plastic Surgery
    • /
    • v.46 no.3
    • /
    • pp.228-234
    • /
    • 2019
  • Background The management of flexor tendon injuries has evolved in recent years through industrial improvements in suture materials, refinements of repair methods, and early rehabilitation protocols. However, there is no consensus on the ideal suture material and technique. This study was conducted to compare the tensile strength, repair time, and characteristics of 4-strand cruciate, modified Kessler, and 4-strand horizontal intrafiber barbed sutures for flexor tenorrhaphy with a 12-mm suture purchase length in an animal model. Methods The right third deep flexors of 60 adult Leghorn chicken feet were isolated and repaired with a 12-mm suture purchase length. The tendons were randomly assigned to three groups of equal number (n=20 each). Groups 1 and 2 received 4-strand cruciate and modified Kessler repair with conventional suture materials, respectively. A 4-strand horizontal intrafiber barbed suture technique was used in group 3. The repaired tendons were biomechanically tested for tensile strength, 2-mm gap resistance, and mode of failure. Repair times were also recorded. Results The maximum tensile strength until failure was $44.6{\pm}4.3N$ in group 1, $35.7{\pm}5.2N$ in group 2, and $56.7{\pm}17.3N$ in group 3. The barbed sutures were superior to the other sutures in terms of the load needed for 2-mm gap formation (P<0.05). Furthermore, the barbed sutures showed the shortest repair time (P<0.05). Conclusions This study found that 4-strand horizontal intrafiber barbed suture repair with a 12-mm purchase length in a chicken flexor tendon injury model showed promising biomechanical properties and took less time to perform than other options.

Arthroscopic transosseous anchorless rotator cuff repair reduces bone defects related to peri-implant cyst formation: a comparison with conventional suture anchors using propensity score matching

  • Hyeon Jang Jeong;Ji Soo Lee;Young Kyu Kim;Sung-Min Rhee;Joo Han Oh
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.276-286
    • /
    • 2023
  • Background: The transosseous anchorless repair (ToR) technique was recently introduced to avoid suture anchor-related problems. While favorable outcomes of the ToR technique have been reported, no previous studies on peri-implant cyst formation with the ToR technique exist. Therefore, this study compared the clinical outcomes and prevalence of peri-implant cyst formation between the ToR technique and the conventional transosseous equivalent technique using suture anchors (SA). Methods: Cases with arthroscopic rotator cuff repair (ARCR) between 2016 and 2018 treated with the double-row suture bridge technique were retrospectively reviewed. Patients were divided into ToR and SA groups. To compare clinical outcomes, 19 ToR and 57 SA cases without intraoperative implant failure were selected using propensity score matching (PSM). While intraoperative implant failure rate was analyzed before PSM, retear rate, peri-implant cyst formation rate, and functional outcomes were compared after PSM. Results: The intraoperative implant failure rate (ToR, 8% vs. SA, 15.3%) and retear rate (ToR, 5.3% vs. SA, 19.3%) did not differ between the two groups (all P>0.05). However, peri-implant cysts were not observed in the ToR group, while they were observed in 16.7% of the SA group (P=0.008). Postoperative functional outcomes were not significantly different between the two groups (all P>0.05). Conclusions: The ToR technique produced comparable clinical outcomes to conventional techniques. Considering the prospect of potential additional surgeries, the absence of peri-implant cyst formation might be an advantage of ToR. Furthermore, ToR might reduce the medical costs related to suture anchors and, thereby, could be a useful option for ARCR. Level of evidence: III.