• Title/Summary/Keyword: Conventional PV module

Search Result 57, Processing Time 0.029 seconds

Development of Building Integrated PV(BIPV) module for the replacement of commercial building envelope materials (건물외피용 태양광발전 BIPV 모듈 개발 연구)

  • Yoon, Jongho;Kim, J.I;Lee, K.S.;Yu, G.J.
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.113-119
    • /
    • 2004
  • As Building Integrated Photovoltaic(BIPV) system replaces the conventional building finishing materials with PV modules, two function of electricity generation and building envelope can be expected. Therefore BIPV can be a good alternative technology for the 21 century environment-friendly buildings. The objective of this paper is to develope BIPV modules for a commercial buildings of which structure is mainly light-weight, curtain wall system. Two types of module are developed for a opaque part and a transparent part of building envelope. Current technology level and market status of Korea determines the configuration of developed BIPV modules. Architectural considerations for the integration of PV module to building envelope such as building structure, construction type, safety, regulation, maintenance etc. have been carefully reflected from the early stage of BIPV module design. Especially the survey result of current building envelope materials determines the size of unit BIPV modules and a unique cladding method for PV module installation is developed. Trial product of BIPV modules and cladding hardwares are manufactured and sample construction details for a demonstration building are proposed.

State of the Art Review of Shading Effects on PV Module Efficiencies and Their Detection Algorithm Focusing on Maximum Power Point

  • Lee, Duk Hwan;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.21-28
    • /
    • 2014
  • This paper provides the up to date review of the shading effects on PV module performance and the associated detection algorithm related to the maximum power point tracking. It includes the brief explanations of the MMP variations due to the shading occurrence on the PV modules. Review of experimental and simulation studies highlighting the significant impacts of shading on PV efficiencies were presented. The literature indicates that even the partial shading of a single cell can greatly drop the entire module voltage and power efficiency. The MMP tracking approaches were also reviewed in this study. Both conventional and advanced soft computing methods such as ANN, FLC and EA were described for the proper tracking of MMP under shaded conditions. This paper would be the basic source and the comprehensive information associated with the shading effects and relevant MPP tracking technique.

A high efficient PV system using series connection of DC-DC converter's output with photovoltaic panel (광전지 패널과 DC-DC 컨버터 출력의 직렬 접속을 이용한 고효율 PV 시스템)

  • Kim, Ho-Sung;Kim, Jong-Hyun;Min, Byung-Duk;Yoo, Dong-Wook;Hong, Ji-Tae;Lee, Dong-Gil;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1146-1147
    • /
    • 2008
  • PV Power Conditioning System (PCS) must have high conversion and low cost. Generally, PV PCS uses either a single converter or multilevel module integrated converter (MIC). Each of these approaches has both advantage and disadvantage. For a high conversion efficiency and low cost of PV module, this paper proposes series connection of module integrated DC-DC converter's output with PV panel. Output voltage of PV panel is connected to the output capacitor of flyback converter. Thus, converter's output voltage is added to the output voltage of PV panel. Isolated DC-DC converter generates only the difference voltage between the PV panel voltage and the required total output voltage. This method reduces power level of DC-DC converter and enhances the energy conversion efficiency compared with conventional DC-DC converter.

  • PDF

Soft Switching DC-DC Converter for AC Module Type PV Module Integrated Converter (AC 모듈형 태양광 모듈 집적형 컨버터를 위한 소프트 스위칭 DC-DC 컨버터)

  • Youn, Sun-Jae;Kim, Young-Ho;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.247-255
    • /
    • 2013
  • In this paper, a soft switching DC-DC converter for AC module type photovoltaic (PV) module integrated converter is proposed. A push-pull converter is suitable for a low voltage PV AC module system because the step-up ratio of a high frequency transformer is high and the number of primary side switches is relatively small. However, the conventional push-pull converters do not have high efficiency because of high switching losses by hard switching and transformer losses (copper and iron losses) by high turns-ratio of the transformer. In the proposed converter, primary side switches are turned on at zero voltage switching (ZCS) condition and turned off at zero current switching (ZVS) condition through parallel resonance between secondary leakage inductance of the transformer and a resonant capacitor. Therefore the proposed push-pull converter decreases the switching loss using soft switching of the primary switches. Also, the turns-ratio of the transformer can be reduced by half using a voltage-doubler of secondary side. The theoretical analysis of the proposed converter is verified by simulation and experimental results.

A study of small size battery charging characteristic by serial-parallel connected DSC module (단위 DSC셀의 직병렬 연결을 통한 소형 배터리 충전특성에 관한 연구)

  • Hong, Ji-Tae;Choi, Jin-Young;Seo, Hyun-Woong;Kim, Mi-Jeong;Sim, Ji-Young;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.192-194
    • /
    • 2006
  • To elucidate possible challenges for outdoor practical use of dye-sensitized solar cells(DSC), compared with conventional Si solar cells. DSC modules still need the larger area than conventional Si solar modules to attain the same rated output because of lower photoelectron-chemical conversion efficiency. However, using batteries backup systems, the measured data shows that DSCs gathered over 12% more electricity than Si solar cells of the same rated output power in same outdoor condition. Moreover, battery charging time of DSC is about 1 hour faster than same rate of Si solar module. In this paper, 12 single DSC cells prepared for 4 serialized DSC cells was connected in 3 row parallel which have same output power rate of Si solar module. This DSC module was practiced generating characteristic experiment over outdoor daylight condition and applied with PV battery charger by using DC-DC converter. The main advantages of DSC module battery charger as compared with conventional Si solar module one are shorter charge time and lower cost.

  • PDF

Fabrication and Evaluation of Low Concentrator Photovoltaic Modules with Aluminium Reflectors (반사판을 이용한 저집속 집광형 태양광 모듈 제작 및 평가)

  • Jeong, Hye-Jeong;Lee, Young-Woo;Ju, Seong-Min;Lee, Ho-Jae;Boo, Seong-Jae
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.17-22
    • /
    • 2008
  • A low concentrating (< 5X) photovoltaic module with aluminum reflectors is fabricated and evaluated which is designed to reduce the affection of the high temperature to the solar cell modules preventing the efficiency lowering. As results, the output power is increased of 1.97X from the concentrating photovoltaic module which is designed with the concentrating ratio of 2.25X and to control the module temperature cooling the module by air circulation. Also, the effect of the concentrating module with aluminum reflectors on the conventional PV module is investigated at the field. The result shows the increase of the output power more than about 20% and the improvement of the module efficiency of 1.4X in spite of the increase of average module temperature.

  • PDF

Economic Analysis on VLS-PV System from Sunbelt Region (Sunbelt 지역의 태양광발전 경제성분석)

  • Choi, Bong-Ha;Park, Soo-Uk;Lee, Deok-Ki;Kim, Seok-Ki;Song, Jin-Soo
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.86-92
    • /
    • 2006
  • This paper analyses the economics of 50kW PV system installed in Tibet and using domestic technology. We show that this system can be expanded to very large-scale photovoltaic power generation [VLS-PV] system successfully. Based on this result, we conduct the economic analysis of 100MW VLS-PV system designed assuming that it will be installed from 2008 to 2017 in Tibet. In this analysis, future price of PV module and system are estimated based on the methodology of experience curve. In 50kW PV system, the generation cost is calculated at 567.2 won/kWh and this is lower than the one of domestic PV system. In future 100MW VLS-PV system. the generation cost is calculated at 305.4 won/kWh by declining system price. If the lifetime and efficiency of the system goes up, due to future technological improvements, the generation cost can be lowered. Moreover, under the environmental and political effect, VLS-PV system can be as competitive as the conventional energy within 20 years.

  • PDF

The Effect of PID Generation by Components of the PV Module (태양전지 모듈의 구성 요소가 PID 발생에 미치는 영향)

  • Kim, Han-Byul;Jung, Tae-Hee;Kang, Gi-Hwan;Chang, Hyo Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.760-765
    • /
    • 2013
  • PID (potential induced degradation) of PV module is the degradation of module due to the high potential difference between the front surface of solar cells and ground when PV modules operate under high humidity and temperature conditions. PID is generally derived from the positive sodium ions in front glass that are accumulated on P-type solar cells. Therefore, some papers for the electrical characteristic of only front components as glass, EVA sheet, solar cell under PID generation condition were revealed. In this paper, we analyzed the different outputs of module with PID by considering the all parts of module including the back side elements such as glass, back sheet. Mini modules with one solar cell were fabricated with the various parts on front and back sided of module. To generate PID of module in a short time, the all modules were applied.1,000 V in $85^{\circ}C$, 85% RH. The outputs, dark IV curves and EL images of all modules before and after experiments were also measured to confirm the main components of module for PID generation. From the measured results, the outputs of all modules with front glass were remarkably reduced and the performances of modules with back and front glass were greatly deteriorated. We suggest that the obtained data could be used to reduce the PID phenomenon of diverse modules such as conventional module and BIPV (building integrated photovoltaic) module.

A Study on the Characteristic of P. I. D Control with M. L. P Communication in GSIKGL (GSIKGL M. L. P 통신에 의한 P. I. D 제어 특성에 관한 연구)

  • Wee, Sung-Dong;Oh, Soo-Hong;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.91-100
    • /
    • 2000
  • An operating principle of PID module was implemented using the load, where the integer in a PID measuring derivate equation were valid in the ranges of 500-9000, 60-1000, and 000-9000, for P, I and D, respectively. A load operation program was designed to investigate the PID theory and its realization process. With it, it was examined the process that the current PV tracts the target SV, By investigating the time when the PV approaches the SV and the rate at which the EV is varied, it is revealed that 1) larger (or Smaller) Kp leads to faster (or slower) approaching of PV to SV, 2) smaller (or larger) Ti results in faster (or slower) approaching of PV to SV, 3) larger (or smaller)$T_d$ causes smaller (or Larger) rate variation in the EV. These observation were found to coincide with those of PID operating characteristics. Though this implementation, it is known for the widespread use of PID module that an improvement should be made in the error of temperature. This, meanwhile, implies that the computational time of conventional manipulation valve must be faster than 0.1 second. It is demanded that an improved PID module including the A/D and D/A module, in itself must be used in conjunction with PLC.

  • PDF

Design and Analysis of SEPIC Converter Based MPPT for Solar PV Module with CPWM

  • Maglin, J.R.;Ramesh, R.;Vaigundamoorthi, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1269-1276
    • /
    • 2014
  • The main objective of this paper is to design DC-DC MPPT circuit using chaotic pulse width modulation to track maximum power from solar PV module for space application. The direct control method of tracking is used to extract maximum power. The nominal duty cycle of the main switch of DC-DC SEPIC converter is adjusted so that the solar panel output impedance is equal to the input resistance of the SEPIC converter which results better spectral performance in the tracked voltages when compared to conventional PWM control. The conversion efficiency of the proposed MPPT system is increased when CPWM is used as a control scheme