• 제목/요약/키워드: Conventional Methods

검색결과 9,101건 처리시간 0.038초

Comparison of Liquid-based Cytology and Conventional Smear in the Evaluation of Sputum Cytology

  • Back, Oun-Cheol
    • 대한임상검사과학회지
    • /
    • 제45권1호
    • /
    • pp.26-31
    • /
    • 2013
  • The cytology of sputum specimens, at a medical facility in Korea, is using the liquid-based cytology and conventional smear method. It confirms the diagnosis using conventional smear methods and the liquid-based cytology. In addition, the diagnosis uses two kinds of each method, compares the suitability, sensitivity and specificity for each test and tries to understand the efficient method needed. It divided sputum specimens in half and liquid-based cytology. A conventional smear method was conducted and the Papanicolaou's staining was conducted using Autostainer. Diagnosed each slide of staining produced smear slides specimens by using an optical microscope. The result of the liquid-based cytology and conventional smear method was that the liquid-based cytology was of a higher-grade than the conventional smear method. It was 36.8%, and 62.8% in the same condition. But only one case was of a lower grade. Liquid-based cytology showed 86.2% of adequacy, 31.0% of sensitivity and 97.5% of specificity. The conventional smear method showed 54.4% of adequacy, 19.6% of sensitivity and 100% of specificity. If it was conducted with two methods at the same time, the results would be similar to the liquid-based cytology. In conclusion, liquid-based cytology has a more superior adequacy and sensitivity than the conventional smear method. The combination of the two methods is similar to the result of only conducting a liquid-based cytology. Conducting a liquid-based cytology rather than the combination of the two ways of sputum cytoscopy, is to be considered as an efficient method to achieve diagnostic accuracy, reduce labor of clinical technologist and pathologist, and to reduce the expense of patients.

  • PDF

Assessment of slope stability using multiple regression analysis

  • Marrapu, Balendra M.;Jakka, Ravi S.
    • Geomechanics and Engineering
    • /
    • 제13권2호
    • /
    • pp.237-254
    • /
    • 2017
  • Estimation of slope stability is a very important task in geotechnical engineering. However, its estimation using conventional and soft computing methods has several drawbacks. Use of conventional limit equilibrium methods for the evaluation of slope stability is very tedious and time consuming, while the use of soft computing approaches like Artificial Neural Networks and Fuzzy Logic are black box approaches. Multiple Regression (MR) analysis provides an alternative to conventional and soft computing methods, for the evaluation of slope stability. MR models provide a simplified equation, which can be used to calculate critical factor of safety of slopes without adopting any iterative procedure, thereby reducing the time and complexity involved in the evaluation of slope stability. In the present study, a multiple regression model has been developed and tested its accuracy in the estimation of slope stability using real field data. Here, two separate multiple regression models have been developed for dry and wet slopes. Further, the accuracy of these developed models have been compared and validated with respect to conventional limit equilibrium methods in terms of Mean Square Error (MSE) & Coefficient of determination ($R^2$). As the developed MR models here are not based on any region specific data and covers wide range of parametric variations, they can be directly applied to any real slopes.

고효율 컬럼과 RRLC를 이용한 담배 주류연 중 페놀 화합물의 분석 효율화 (Enhancement of Analytical Method for Phenolic Compounds in Mainstream Cigarette Smoke Using High Efficiency Column and RRLC system)

  • 민혜정;강영희;이정민;장기철
    • 한국연초학회지
    • /
    • 제32권1호
    • /
    • pp.35-40
    • /
    • 2010
  • This study was carried out to enhance the analytical methods of phenolic compounds in mainstream cigarette smoke using high efficiency column and RRLC(Rapid Resolution Liquid Chromatography) system, and to compare these methods. RRLC system offers significantly faster results with higher data quality of phenolic compounds than conventional HPLC, but it is disadvantage that it is expensive. On the other hand, the method using monolithic column offers faster results by the use of conventional HPLC system without new equipment introduction. In this study, we used the linear type smoking machine and Health Canada method for pre-treatment process of phenolic compounds. The analysis time of phenolic compounds using RRLC and monolithic column was individually 8 and 15 minutes, whereas in the conventional HPLC it was 45 minutes. These new methods were accompanied with the minimal solvent consumption and had lower analysis costs. Also, we proved that there were no difference between new methods and conventional method in accuracy by statistic.

Comparative Evaluation of Three Purification Methods for the Nucleocapsid Protein of Newcastle Disease Virus from Escherichia coli Homogenates

  • Tan Yan Peng;Ling Tau Chuan;Yusoff Khatijah;Tan Wen Siang;Tey Beng Ti
    • Journal of Microbiology
    • /
    • 제43권3호
    • /
    • pp.295-300
    • /
    • 2005
  • In the present study, the performances of conventional purification methods, packed bed adsorption (PBA), and expanded bed adsorption (EBA) for the purification of the nucleocapsid protein (NP) of Newcastle disease virus (NDV) from Escherichia coli homogenates were evaluated. The conventional methods for the recovery of NP proteins involved multiple steps, such as centrifugation, precipitation, dialysis, and sucrose gradient ultracentrifugation. For the PBA, clarified feedstock was used for column loading, while in EBA, unclarified feedstock was used. Streamline chelating immobilized with $Ni^{2+}$ ion was used as an affinity ligand for both PBA and EBA. The final protein yield obtained in conventional and PBA methods was $1.26\%$ and $5.56\%$, respectively. It was demonstrated that EBA achieved the highest final protein yield of $9.6\%$ with a purification factor of 7. Additionally, the total processing time of the EBA process has been shortened by 8 times compared to that of the conventional method.

비전형적인 품질 요구사항을 고려한 실용적 소프트웨어 아키텍처 설계 기법 (Practical Software Architecture Design Methods for Non-Conventional Quality Requirements)

  • 라현정;김수동
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제6권8호
    • /
    • pp.391-400
    • /
    • 2017
  • 소프트웨어 아키텍처는 비기능적 요구사항(Non-Functional Requirement, NFR), 즉 품질 요구사항과 제약사항을 만족시키는데 중요한 역할을 한다. 현재까지 진행된 대부부의 연구는 전형적인 NFR을 위한 아키텍처 설계 방법과 설계 택틱에 국한된다. 그러나, 목표 시스템에 특화된 비전형적인 NFR을 위한 설계 방법에 대한 연구는 많이 진행되고 있지 않고, 소프트웨어 아키텍트가 보유한 지식과 경험에 의해 비전형적인 NFR을 만족시킬 수 있는 효과적인 방법과 택틱을 유도하고 이를 기반으로 아키텍처를 설계한다. 그러므로, 비전형적인 NFR을 고려하여 아키텍처를 설계하는 효과적인 방법 및 택틱을 고안하는 것이 어렵다. 본 논문에서는 비전형적인 NFR을 만족시키는 소프트웨어 아키텍처를 설계하는 효과적이며 체계적인 아키텍처 설계 방법론을 제안한다. 이 방법론은 전형적인 NFR을 고려한 아키텍처 설계에도 적용될 수 있다. 제안된 방법론은 5개의 스텝으로 구성된 프로세스, 각 스텝에 대한 상세 활동 지침을 포함한다. 그리고, 제안된 프로세스가 잘 설계되었음을 보이기 위해, 산출물 간의 추적성 관계를 확인한다. 마지막으로, 제안된 방법론의 효율성과 실용성을 평가하기 위해 사례 연구를 수행한 결과를 제시한다.

적응 윈도윙을 기반으로한 적응 필터 (Adaptive Filter Based on Adaptive Windowing)

  • 우종진;신현출;송우진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 제14회 신호처리 합동 학술대회 논문집
    • /
    • pp.81-84
    • /
    • 2001
  • We propose a novel noise littering method based on adaptive windowing. To restore a noisy signal adaptive filtering methods have been widely researched and used. However, conventional adaptive filtering methods have a trade-off between noise suppression and edge preservation since they adopt fixed size filters. In this paper applying the adaptive windowing concept to adaptive filtering, we overcome the trade-off, The filter size is adaptively selected depending on signal statistics. The visual results of the signal and image restorations convincingly show the superior preservation of edge and detail and suppression of noise for the proposed adaptive windowed adaptive filter compared with conventional methods.

  • PDF

New Splitting Criteria for Classification Trees

  • Lee, Yung-Seop
    • Communications for Statistical Applications and Methods
    • /
    • 제8권3호
    • /
    • pp.885-894
    • /
    • 2001
  • Decision tree methods is the one of data mining techniques. Classification trees are used to predict a class label. When a tree grows, the conventional splitting criteria use the weighted average of the left and the right child nodes for measuring the node impurity. In this paper, new splitting criteria for classification trees are proposed which improve the interpretablity of trees comparing to the conventional methods. The criteria search only for interesting subsets of the data, as opposed to modeling all of the data equally well. As a result, the tree is very unbalanced but extremely interpretable.

  • PDF

비실험자료를 이용한 연구에서 인과적 추론의 강화: 성향점수와 도구변수 방법의 적용 (Strengthening Causal Inference in Studies using Non-experimental Data: An Application of Propensity Score and Instrumental Variable Methods)

  • 김명희;도영경
    • Journal of Preventive Medicine and Public Health
    • /
    • 제40권6호
    • /
    • pp.495-504
    • /
    • 2007
  • Objectives : This study attempts to show how studies using non-experimental data can strengthen causal inferences by applying propensity score and instrumental variable methods based on the counterfactual framework. For illustrative purposes, we examine the effect of having private health insurance on the probability of experiencing at least one hospital admission in the previous year. Methods : Using data from the 4th wave of the Korea Labor and Income Panel Study, we compared the results obtained using propensity score and instrumental variable methods with those from conventional logistic and linear regression models, respectively. Results : While conventional multiple regression analyses fail to identify the effect, the results estimated using propensity score and instrumental variable methods suggest that having private health insurance has positive and statistically significant effects on hospital admission. Conclusions : This study demonstrates that propensity score and instrumental variable methods provide potentially useful alternatives to conventional regression approaches in making causal inferences using non-experimental data.

디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교 (The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph)

  • 김미자;허경회;이원진;허민석;이삼선;이진구;안병근;최순철
    • Imaging Science in Dentistry
    • /
    • 제35권1호
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques

  • Kocaagaoglu, Hasan;Albayrak, Haydar;Sahin, Sezgi Cinel;Gurbulak, Aysegul Guleryuz
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.262-270
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to evaluate the marginal misfits of three-unit frameworks fabricated with conventional and digital impressions techniques. MATERIALS AND METHODS. Thirty brass canine and second premolar abutment preparations were fabricated by using a computer numerical control machine and were randomly divided into 3 groups (n=10) as follows: conventional impression group (Group Ci), Cerec Omnicam (Group Cdi), and 3shape TRIOS-3 (Group Tdi) digital impression groups. The laser-sintered metal frameworks were designed and fabricated with conventional and digital impressions. The marginal adaptation was assessed with a stereomicroscope at ${\times}30$ magnification. The data were analyzed with 1-way analysis of variances (ANOVAs) and the independent simple t tests. RESULTS. A statistically significant difference was found between the frameworks fabricated by conventional methods and those fabricated by digital impression methods. Multiple comparison results revealed that the frameworks in Group Ci (average, $98.8{\pm}16.43{\mu}m$; canine, $93.59{\pm}16.82{\mu}m$; premolar, $104.10{\pm}15.02{\mu}m$) had larger marginal misfit values than those in Group Cdi (average, $63.78{\pm}14.05{\mu}m$; canine, $62.73{\pm}13.71{\mu}m$; premolar, $64.84{\pm}15.06{\mu}m$) and Group Tdi (average, $65.14{\pm}18.05{\mu}m$; canine, $70.64{\pm}19.02{\mu}m$; premolar, $59.64{\pm}16.10{\mu}m$) (P=.000 for average; P=.001 for canine; P<.001 for premolar). No statistical difference was found between the marginal misfits of canine and premolar abutment teeth within the same groups (P>.05). CONCLUSION. The three-unit frameworks fabricated with digital impression techniques showed better marginal fit compared to conventional impression techniques. All marginal misfit values were clinically acceptable.