• Title/Summary/Keyword: Convective Heat Transfer

Search Result 600, Processing Time 0.027 seconds

Comparative Investigation of Convective Heat Transfer Coefficients for Analyzing Compressed Hydrogen Fueling Process (압축 수소 충전 공정 해석을 위한 대류 열전달 계수 비교 분석)

  • Hyo Min Seo;Byung Heung Park
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.123-133
    • /
    • 2023
  • Commercial hydrogen fuel cell vehicles are charged by compressing gaseous hydrogen to high pressure and storing it in a storage tank in the vehicle. This process causes the temperature of the gas to rise, to ensure the safety to storage tanks, the temperature is limited. Therefore, a heat transfer model is needed to explain this temperature rise. The heat transfer model includes the convective heat transfer phenomenon, and accurate estimation is required. In this study, the convective heat transfer coefficient in the hydrogen fueling process was calculated and compared using various correlation equations considering physical phenomena. The hydrogen fueling process was classified into the fueling line from the dispenser to the tank inlet and the storage tank in the vehicle, and the convective heat transfer coefficients were estimated according to process parameters such as mass flow rate, diameter, temperature and pressure. As a result, in the case of the inside of the filling line, the convective heat transfer coefficient was about 1000 times larger than that of the inside of the storage tank, and in the case of the outside of the filling line, the convective heat transfer coefficient was about 3 times larger than that of the outside of the storage tank. Finally, as a result of a comprehensive analysis of convective heat transfer coefficients in each process, it was found that outside the storage tank was lowest in the entire hydrogen fueling process, thus dominated the heat transfer phenomenon.

Convective Heat Transfer to Water near the Critical Region in Horizontal Rectangular Ducts (수평 직사각 덕트 내 임계점 부근 물의 대류열전달 특성)

  • Lee, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.477-485
    • /
    • 2012
  • Fluid flow and heat transfer in horizontal ducts are strongly coupled with large changes in thermodynamic and transport properties near the critical region as well as the gravity force. Numerical analysis has been carried out to investigate convective heat transfer in horizontal rectangular ducts for water near the thermodynamic critical point. Convective heat transfer characteristics, including velocity, temperature, and the properties as well as local heat transfer coefficients along the ducts are compared with the effect of proximity on the critical point. When there is flow acceleration because of a density decrease, convective heat transfer characteristics in the ducts show transition behavior between liquid-like and gas-like phases. There is a large variation in the local heat transfer coefficient distributions at the top, side, and bottom surfaces, and close to the pseudocritical temperature, a peak in the heat transfer coefficient distribution resulting from improved turbulent transport is observed. The Nusselt number distribution depends on pressure and duct aspect ratio, while the Nusselt number peak rapidly increases as the pressure approaches the critical pressure. The predicted Nusselt number is also compared with other heat transfer correlations.

Laminar Forced Convective Heat Transfer to Near-Critical Water in a Tube

  • Lee, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1756-1766
    • /
    • 2003
  • Numerical modeling is carried out to investigate forced convective heat transfer to near-critical water in developing laminar flow through a circular tube. Due to large variations of thermo-physical properties such as density, specific heat, viscosity, and thermal conductivity near thermodynamic critical point, heat transfer characteristics show quite different behavior compared with pure forced convection. With flow acceleration along the tube unusual behavior of heat transfer coefficient and friction factor occurs when the fluid enthalpy passes through pseudocritical point of pressure in the tube. There is also a transition behavior from liquid-like phase to gas-like phase in the developing region. Numerical results with constant heat flux boundary conditions are obtained for reduced pressures from 1.09 to 1.99. Graphical results for velocity, temperature, and heat transfer coefficient with Stanton number are presented and analyzed.

Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures (순수 및 혼합냉매의 유동증발 열전달 상관식)

  • Shin, J.Y.;Kim, M.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF

Analysis for Air-Side Convective Heat Transfer Characteristics in Compact Heat Exchangers (밀집형 열교환기 내 공기 측 대류열전달특성)

  • Moh, Jeong-Hah;Lee, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1443-1448
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchangers with continuous plate fins. Simulation results such as air flow and temperature distributions are presented, and heat transfer characteristics are compared for various inlet conditions. Results from various turbulence models are also compared for applicability. There is large difference between the local heat transfer coefficient distributions along the cylinder wall for circular tubes. Colburn j factors from the calculated results of circular and flat tubes in the heat exchangers are compared for various Reynolds number. The predicted results in this study can be applied to the optimal design of air conditioning system. with compact heat exchanger.

  • PDF

Heat Transfer Characteristics of a Slot Jet and Circular Jets Impinging on a Flat Surface (벽면에 충돌하는 슬롯형 제트와 원형 제트의 열전달 효과 비교)

  • Kim, Hui-Hyun;Kim, Dae-Seong;Yoon, Soon-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.540-545
    • /
    • 2001
  • An experimental study was conducted to compare the heat transfer characteristics of an impinging slot jet and three kinds of impinging circular jets. Thermochromic liquid crystal with an image processing system was employed to measure the temperature of impinging wall where constant heat flux condition was applied. The distribution of convective heat transfer coefficients were then evaluated for eight nozzle-to-surface distance settings for each jet cases. The cooling effect was linearly proportional to the number of nozzles for circular jet cases at the same nozzle exit speed. However, the heat transfer under constant volume flow rate was the most at single circular jet. It was concluded that the overall convective heat transfer was better at the circular jets than the slot jet.

  • PDF

Inverse Estimation of Convective Heat Transfer Coefficient, Emissivity and Flame Heat Flux on the Surface (표면의 대류열전달계수, 방사율 및 화염 열유속 역해석 연구)

  • Yoon, Kyung-Beom;Park, Won-Hee
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.15-20
    • /
    • 2013
  • The convective heat transfer coefficient, emissivity, and flame heat flux on the surface of Duglas fir are estimated by using repulsive particle swarm optimization. The surface temperature, mass loss rate, and ignition time are measured for various incident heat fluxes from a cone heater of the cone calorimeter. The calculated surface temperatures obtained by using the optimized convective heat transfer coefficient, emissivity and flame heat flux on the surface in this study match well with those obtained from the test. The maximum error between the predicted and measured surface temperatures for the three different external heat fluxes is within 2% showing reasonable agreements. The methodology proposed in this study can be used to obtain various values related to heat transfer on a flaming surface that are difficult to measure in experiments.

Experimental Measurement and Numerical Computation on the Air-Side Forced Convective Heat Tranfer Coefficient in Plate Fin-Tube Exchangers (평판 핀 튜브 열교환기의 공기측 강제대류 열전달계수에 대한 실험 및 수치계산)

  • Yoon, Young-Hwan;Paeng, Jin-Gi;Yoon, Keon-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.729-737
    • /
    • 2006
  • Air-side forced convective heat transfer of a plate fin-tube heat exchanger is investigated by experimental measurement and numerical computation. The heat exchanger consists of staggered arrangement of refrigerant pipes of 10.2 m diameter and the pitch of fins is 3.5 m. In the experimental study, the forced convective heat transfer is measured at Reynolds number of 1082, 1397, 1486, 1591 and 1649 based on diameter of refrigerant piping and mean velocity. Average Nusselt number for the convective heat transfer coefficient is also computed for the same Reynolds number by commercial software of STAR-CD with standard $k-{\varepsilon}$ turbulent model. It is found that the relative errors of average Nusselt numbers between experimental and numerical data are less than 6 percentage in Reynolds number of $1082{\sim}1649$. The errors between experiment and other correlations are ranged from 7% to 32.4%. But the correlation of Kim at al is closest to the experimental data within 7% of the relative error.

The Characteristics of Convective Heat Transfer in Non Boiling Vertical Downard Flow (비비등 수직 하향 유동의 대류 열전달 특성)

  • Lee, D.S.;Kim, J.G.;Yang, H.J.;Oh, Y.K.;Cha, K.O.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.118-123
    • /
    • 2000
  • This experimental study was conducted to figure out the characteristics of convective heat transfer in non boiling vertical downward flow with polymer additives. This experiment was studied in 26mm diameter, 800mm heating length and $1{\times}10^5W/m^2$ heat flux. The polymer concentration ranged from 0PPM to 500PPM with corresponding from Reynolds number $3.3{\times}10^4$ to $6.8{\times}10^4$ in non boiling vertical downward flow. Experimental results show that the characteristics of convective heat transfer was a strong function of polymer concentration and it has decreased with increasing the polymer concentration in non boiling vertical downward flow.

  • PDF

NUMERICAL STUDY ON COMBINED HEAT TRANSFER IN NIR HEATING CHAMBER (근적외선 열풍기의 복합열전달에 관한 수치적 연구)

  • Choi, H.K.;Yoo, G.J.;Kim, I.H.
    • Journal of computational fluids engineering
    • /
    • v.12 no.4
    • /
    • pp.7-13
    • /
    • 2007
  • Numerical analysis is carried out for combined heat transfer in an indirected NIR(Near Infrared Ray) heating chamber. Reynolds number and shapes of absorbed cylinder are known as important parameters on the combined heat transfer effects. Reynolds number based on the outer diameter of the cylinder is varied from $10^3$ to $3{\times}10^5$. Four difference heat transfer regimes are observed: forced convection and radiative heat transfer on the outer surface of the cylinder, pure conduction in the cylinder body, pure natural convection and radiation between lamp surface and inner surface of the cylinder, and radiation from the lamp. Flow and temperature characteristics are presented with iso-contour lines for the absorbed circular and elliptic cylinders to compare their differences. The convective and radiative heat transfer fluxes are also compared with different Reynolds numbers. As usual, Reynolds number is an important factor to estimate increasing convective heat transfer as it increases. The shape of absorbed cylinder results overall heat transfer rates remain unchanged.