• 제목/요약/키워드: Convection Heat Transfer

검색결과 976건 처리시간 0.026초

보론 강판의 핫 프레스 포밍 공정 시 재료 물성 모델러와 DEFORMTM-HT를 활용한 상 변태 예측 (Prediction of Phase Transformation of Boron Steel Sheet during Hot Press Forming using Material Properties Modeler and DEFORMTM-HT)

  • 강경필;이경훈;김영석;지민욱;서영성
    • 소성∙가공
    • /
    • 제17권4호
    • /
    • pp.249-256
    • /
    • 2008
  • Combined phase transformation and heat transfer was considered on the simulation of hot press forming process, using material properties modeler, $JMatPro^{(R)}$ and a finite element package, $DEFORM^{TM}$-HT. In order to obtain high temperature mechanical properties and flow curves for different phases, a material properties modeler, $JMatPro^{(R)}$ was used, avoiding expensive and extensive high temperature materials tests. The results successfully show that the strength of hot press forming parts may exhibit different strength in the same parts, depending on the contact of blank with tooling. It was also shown effectively that the strength of the parts can be controlled by designing appropriate cooling paths and coolants. This was shown in terms of different heat convection coefficient in the calculation. Overall, current combination of software was shown to be an effective tool for the tool and process design of hot forming process, although the material modeler needs to be additionally verified by an appropriate set of high temperature materials test.

사용후핵연료 저장용기의 정상 및 비정상조건에 대한 열해석 (Thermal Analysis of a Spent Fuel Storage Cask under Normal and Off-Normal Conditions)

  • Ju-Chan Lee;Kyung-Sik Bang;Ki-Seog Seo;Ho-Dong Kim;Byung-Il Choi;Heung-Young Lee
    • 방사성폐기물학회지
    • /
    • 제2권1호
    • /
    • pp.13-22
    • /
    • 2004
  • This study presents the thermal analyses of a spent fuel dry storage cask under normal and off-normal conditions. The environmental temperature is assumed to be 15 $^{\circ}C$ under the normal condition. The off-normal condition has an environmental temperature of 38 $^{\circ}C$. An additional off-normal condition is considered as a partial blockage of the air inlet ducts. Two of the four air inlet ducts are assumed to be completely blocked. The significant thermal design feature of the storage cask is the air flow path used to remove the decay heat from the spent fuel. Natural circulation of the air inside the cask allows the concrete and fuel cladding temperatures to be maintained below the allowable values. The finite volume computational fluid dynamics code FLUENT was used for the thermal analysis. The maximum temperatures of the fuel rod and concrete overpack were lower than the allowable values under the normal and off-normal conditions.

  • PDF

제한공간내 펄스가열에 기인한 열음향파의 전달특성에 관한 수치적 연구 (A Numerical Study on the Transmission of Thermo-Acoustic Wave Induced by Step Pulsed Heating in an Enclosure)

  • 황인주;김윤제
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.914-922
    • /
    • 2002
  • Thermo-acoustic waves can be thermally generated in a compressible flow field by rapid heating and cooling, and chemical reaction near the boundary walls. This mechanism is very important in the space environment in which natural convection does not exist. Also this may be a significant factor for heat transfer when the fluids are close to the thermodynamic critical point. In this study, the generation and transmission characteristics of thermo-acoustic waves in an air-filled confined domain with two-step pulsed heating are studied numerically. The governing equations are discretized using control volume method, and are solved using PISO algorithm and second-order upwind scheme. For the purpose of stable solution, time step was set to the order of $1\times10_-9s,\;and\;grids\;are\;50\times2000$. Results show that temperature and pressure distributions of fluid near the boundary wall subjected to a rapid heating are increased abruptly, and the induced thermo-acoustic wave propagates through the fluid until it decays due to viscous and heat dissipation. Pressure waves have sharp front shape and decay with a long tail in the case of step heating, but these waves have sharp pin shape in the case of pulsed heating.

공기순환구조를 갖는 축열지붕의 열전달해석 (Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System)

  • 신우철;박석현;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

자연대류 영향을 고려한 상변화 열에너지 저장장치의 열전도향상에 관한 수치적 연구 (Numerical Study on Enhanced Heat Conduction of Phase-Change Thermal Energy Storage Devices in The Presence of Natural Convection)

  • Chung, Hong-Chul
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.207-212
    • /
    • 1993
  • 상변화 에너지 저장장치는 변동하는 액체-고체 상접합면과 자연대류의 존재에 기인한 비선형성 때문에 해석적으로 분석하기가 어렵다. 핀(fin) 형태의 상변화 에너지 저장장치를 준선형화 시켜 열전달을 수치적으로 해석하여 실험 데이타와 비교 검증하였다. 대칭형 수평 핀에 대하여 준선형, 비정상의 얇은 2차원적 모델을 세우고 유한체적방법(FVM)에 의해 시간의 함수로 융해된 상변화물질의 비율과 액체-고체 상접합면의 형상을 예측하였다. 유한체적방법(FVM)에 의한 결과는 실험결과와 비교적 잘 일치하였다. 벽과 융해점 사이의 온도차가 클수록 융해된 상변화물질의 비율은 증가하였으며 대류항을 포함하는 경우가 없는 경우보다 실험결과에 더 가까운 해를 얻을 수 있었다.

  • PDF

소형 Slot less PMSM의 coil 배치에 따른 최적 설계 및 열 내구성 분석 (A Study on Optimal Design According to Change of Coil Distribution in Slot Less Type Permanent Magnet Synchronous Motor)

  • 김용태;고덕화;김규화;백성민;김규탁
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.27-32
    • /
    • 2017
  • In this paper, slot less type high-speed and compact motor was designed. it was selected through change of stator coil distribution for the optimal performance of the motor. In this paper, designed motor was expected to be very vulnerable to heat dissipation in a compact motor. Therefore, to ensure reliability in the design result, winding and permanent magnet damage caused by the losses of motor was analyzed by thermal analysis and demagnetization analysis. Using the result, whether motor burnout was confirmed by motor performance degradation and insulation breakdown.

Mechanical and Thermal Properties of Industrial Protective Fabric with Recycled m-Aramid and Natural Fiber

  • Sung, Eun Ji;Baek, Young Mee;An, Seung Kook
    • 한국염색가공학회지
    • /
    • 제30권4호
    • /
    • pp.227-236
    • /
    • 2018
  • As consciousness of safety becomes an important social issue, the demand for protective clothing is increasing. Conventional flame-retardant cotton working wear has low durability, and working wear with m-aramid fibers are stiff, heavy, less permeable, and expensive. In this study, recycled m-aramid and cotton have been blended to produce woven fabric of different compositions to enhance high performance and comfort to solve aforementioned problems. The fabrics were analyzed according to constituents and various structural factors. Mechanical properties were measured using KES-FB system. The measured thermal properties are TGA, $Q_{max}$, TPP and RPP. Fabric with polyurethane yarn covered by m-aramid/cotton spun yarn is observed to have good wearability. The fabric of open end spun yarn showed more stiffness than that of ring spun yarn. The sample with the high count of yarn has more smooth surface. In addition, high m-aramid content fabric is considered to have relatively high stiffness when using as clothing. In TGA the fabric with higher m-aramid content showed more stable decomposition behavior. The fabric having rough surface showed lower heat transfer properties in $Q_{max}$. The influence of the fabric thickness was important in convection and radiant heat test.

Influence of thermal radiation and magnetohydrodynamic on the laminar flow: Williamson fluid for velocity profile

  • Muzamal Hussain;Humaira Sharif;Mohammad Amien Khadimallah;Hamdi Ayed;Abir Mouldi;Muhammad Naeem Mohsin;Sajjad Hussain;Abdelouahed Tounsi
    • Advances in nano research
    • /
    • 제16권4호
    • /
    • pp.427-434
    • /
    • 2024
  • Latest advancement in field of fluid dynamics has taken nanofluid under consideration which shows large thermal conductance and enlarges property of heat transformation in fluids. Motivated by this, the key aim of the current investigation scrutinizes the influence of thermal radiation and magnetohydrodynamic on the laminar flow of an incompressible two-dimensional Williamson nanofluid over an inclined surface in the presence of motile microorganism. In addition, the impact of heat absorption/generation and Arrhenius activation energy is also examined. A mathematical modeled is developed which stimulate the physical flow problem. By using the compatible similarities, we transfer the governing PDEs into ODEs. The analytic approach based on Homotopy analysis method is introduced to impose the analytic solution by using Mathematica software. The impacts of distinct pertinent variable on velocity profiles are investigated through graphs.

Development and validation of the lead-bismuth cooled reactor system code based on a fully implicit homogeneous flow model

  • Ge Li;Wang Jingxin;Fan Kun;Zhang Jie;Shan Jianqiang
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1213-1224
    • /
    • 2024
  • The liquid lead-bismuth cooled fast reactor has been in a single-phase, low-pressure, and high-temperature state for a long time during operation. Considering the requirement of calculation efficiency for long-term transient accident calculation, based on a homogeneous hydrodynamic model, one-dimensional heat conduction model, coolant flow and heat transfer model, neutron kinetics model, coolant and material properties model, this study used the fully implicit difference scheme algorithm of the convection-diffusion term to solve the basic conservation equation, to develop the transient analysis program NUSOL-LMR 2.0 for the lead-bismuth fast reactor system. The steady-state and typical design basis accidents (including reactivity introduction, loss of flow caused by main pump idling, excessive cooling, and plant power outage accidents) for the ABR have been analyzed. The results are compared with the international system analysis software ATHENA. The results indicate that the developed program can stably, accurately, and efficiently predict the transient accident response and safety characteristics of the lead-bismuth fast reactor system.

비균일 대칭성 열Flux인 수직 사각 닥트내의 층류조합대류 열전달 효과 (Laminar Convective Heat Transfer in Vertical Square Duct with Variational Symmetric Heat Flux)

  • 김시영
    • 수산해양기술연구
    • /
    • 제18권1호
    • /
    • pp.47-53
    • /
    • 1982
  • 본 논문은 비균일대칭성 열Flux인 수직사각 Duct내의 층류조합대류 열전달 효과를 해석하기 위하여 그 유동의 특성 지배 방정식 및 비균일 열Flux의 경계조건을 무차원화 시켜 이를 Galerkin's 방법에 의해 유한요소식으로 정식화하고 이에 대하여 R 하(a) 수 및 압력구배 변수에 대해서 Duct 내의 온도분포, 속도분포 및 Nusselt 수의 값을 계산하였고 온도분포를 열 Flux가 일정 및 없는 경우와 비교하였으며 또 닥트내의 열전달 특성을 R 하(a) 수, 응력구배변수 및 Corner에 따른 변호경향을 조사하였다. 그 결과 1. 본 해석의 경계벽 온도분포 계산치와 유효자료들과의 비교에서 열 Flux가 일정 또는 없는 경우는 그 값이 일치하였다. 2. 닥트내의 온도분포와 Nusselt수의 값은 R 하(a) 수 및 압력구배 변수에 비례하여 증감하였다. 3. Nusselt수는 Corner에서 유속지연에 의한 온도분포의 특성 때문에 그 값이 감소하였으며 최대치는 0.7부근이었다

  • PDF