• Title/Summary/Keyword: Convection Heat Transfer

Search Result 971, Processing Time 0.027 seconds

The Effects of Top and Bottom Lids on the Natural Convection Heat Transfer inside Vertical Cylinders (수직 원형관 내부에서 발생하는 자연대류 열전달에서 상·하단 마개의 영향)

  • Kang, Gyeong-Uk;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.242-251
    • /
    • 2011
  • The effects of top and bottom lids on the natural convection heat transfer phenomena inside vertical cylinders were investigated experimentally for $Ra_{Lw}$ from $9.26{\times}10^9$ to $7.74{\times}10^{12}$. Using the concept of analogy between heat and mass transfer, a cupric acid-copper sulfate electroplating system was employed as mass transfer experiments replacing heat transfer experiments. The natural convection heat transfer of both-open cylinders in laminar and turbulent flows was in good agreement with the existing heat transfer correlations developed for vertical plates. The effects of top and bottom lids on the heat transfer rates were very similar to the studies of Krysa et al. and Sedahmed et al. and Chung et al. With the copper lids, the bottom-closed cavity showed the highest heat transfer rates and then followed both-closed, top-closed, both-open ones in both laminar and turbulent flows. However with the acryl lids, the similar trends were observed except that the heat transfer rates for both-open were higher than top-closed one. The use of the copper lids increased the heat transfer rates compared to the acryl lids due to the hydrodynamic interaction of the flows developed for the different heated faces. This study extended the ranges of flow conditions of the existing literatures and proposed the empirical correlations.

Forced Convection Characteristics of V type Circular-finned Tube Heat Exchanger (V형 원형휜-원형관의 강제대류 열유동 특성)

  • Lee, Jong-Hwi;Lim, Mu-Gi;Kang, Hie-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1348-1354
    • /
    • 2009
  • The purpose of the present study is to investigate the flow resistance and the heat transfer characteristics of V type circular fin-tube heat exchanger. Four kinds of V type fin having the same fin area and the different span wise angle tested numerically. Test data for the heat transfer, pressure drop and fin temperature were shown and discussed. The pressure drop and heat transfer increased for decreasing the span wise angle up to 58% and 25% respectively.

  • PDF

Mass Transfer Experiments for the Heat Load During In-Vessel Retention of Core Melt

  • Park, Hae-Kyun;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.906-914
    • /
    • 2016
  • We investigated the heat load imposed on the lower head of a reactor vessel by the natural convection of the oxide pool in a severe accident. Mass transfer experiments using a $CuSO_4-H_2SO_4$ electroplating system were performed based on the analogy between heat and mass transfer. The $Ra^{\prime}_H$ of $10^{14}$ order was achieved with a facility height of only 0.1 m. Three different volumetric heat sources were compared; two had identical configurations to those previously reported, and the other was designed by the authors. The measured Nu's of the lower head were about 30% lower than those previously reported. The measured angular heat flux ratios were similar to those reported in existing studies except for the peaks appearing near the top. The volumetric heat sources did not affect the Nu of the lower head but affected the Nu of the top plate by obstructing the rising flow from the bottom.

Forced Convection Characteristics of V shape Circular fin-tube Heat Exchanger (V형 원형휜-원형관의 강제대류 열유동 특성)

  • Lee, Jong-Hwi;Lim, Moo-Gi;Kang, Hie-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.649-655
    • /
    • 2009
  • The purpose of the present study is to investigate the flow resistances and heat transfer characteristics of V-shaped circular fin-tube heat exchangers. Four types of V-shaped fins in which the fin areas are identical but the areas of the V-shaped portion are different have been tested numerically. The results obtained for heat transfer, pressure drop, and fin temperature are discussed in this paper. With increase in the area of the V-shaped portion, the pressure drop and heat transfer increase up to 40% and 24%, respectively, in the present test range.

A Study on Cooling Characteristics of the LED Lamp Heat Sink for Automobile by Forced Convection (강제대류에 의한 자동차용 램프 방열판의 냉각 특성에 LED 관한 연구)

  • Yang, Ho-Dong;Yoo, Jae-Young;Park, Seul-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.117-123
    • /
    • 2018
  • Automotive headlamps have been continuously developed as one of the most important devices for securing the driver's view, and the LED lamps are getting popular in recent years. However, in case of the LED lamps, because the heat generated by the LED lamps are too high, it shorten the product life and lower the LED efficiency. Therefore, this study was investigated the cooling characteristics of the LED lamp heat sink for automobile by forced convection for LED heat generation control. In order to analyze the cooling characteristics of the heat sink, the temperature distribution results were investigated through the experiment and computational analysis under the increase of the air flow velocity, and the convective heat transfer coefficient was obtained. Also, convective heat transfer coefficient was calculated by the theoretical formula under the same condition and compared with experimental and computational results. From the result of this study, as the air flow velocity around the heat sink fins increased, the convective heat transfer coefficient significantly increased, confirming the improvement in the cooling effect.

Study on the Experiment and Numerical Computation of Forced Convection Heat Transfer around Circular Cylinder in a Rectangular Duct (사각덕트 내에서 원형 실린더 주위의 강제대류 열전달에 대한 실험과 수치계산에 관한 연구)

  • 윤영환;김경환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.490-498
    • /
    • 2004
  • This paper measures the forced convective heat transfer from heated cylinder to air flow in a rectangular duct at Re$_{D}$ =2,337, 4,589, 6,621 and 7,944 through experiments. And the heat transfer is computed by 3-D numerical computation in which various turbulent models are applied. It is shown through the comparison of experimental and computed data that numerical computation with standard k-$\varepsilon$ model predicts the experimental data most accurately. Furthermore, the correlation from the computed heat transfer is almost similar to that from the experiment when Re$_{D}$ is greater than 4,589. In addition, the correlation of McAdams is the closest to that from experimental data among various correlations from literature in the range of Reynolds number.ber.

An Experimental Investigation on Combined Convective Heat Transfer of NonNewtonian Fluids (비뉴톤유체의 복합대류 열전달에 관한 실험적 연구)

  • 김용진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1770-1779
    • /
    • 1995
  • A combined convective heat transfer study for non-Newtonian fluids was experimentally performed in uniformly heated horizontal tubes with laminar flow in the thermal entry region. Velocity profiles were fully developed at the entrance of the heated sections in the tubes. Aqueous solutions of sodium carboxymethylcellulose(CMC ) were used; their behavior showed a reasonably good fit into the power-law model, .tau.=K.gamma.$^{n}$ . The test sections were made of copper with inside diameters of 3.23 cm and 5.042 cm and lengths of approximately 300 cm. Most experimental runs displayed noticeable secondary flows caused by buoyancy ; when present, secondary flows caused significant increase in the rate of heat transfer over the purely forced-convection case. A correlation, which relates the rate of heat transfer for flows with temperature-dependent properties, free convection effects, and non-newtonian effects, was suggested.

HEAT AND MASS TRANSFER EFFECTS ON MHD NATURAL CONVECTION FLOW PAST AN INFINITE INCLINED PLATE WITH RAMPED TEMPERATURE

  • SHERI, SIVA REDDY;SURAM, ANJAN KUMAR;MODULGUA, PRASANTHI
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.20 no.4
    • /
    • pp.355-374
    • /
    • 2016
  • This work is devoted to investigate heat and mass transfer effects on MHD natural convection flow past an inclined plate with ramped temperature numerically. The dimensionless governing equations for this investigation are solved by using finite element method. The effects of angle inclination, buoyancy ratio parameter, permeability parameter, magnetic parameter, Prandtl number, heat generation, thermal radiation, Eckert number, Schmidt number, chemical reaction parameter and time on velocity, temperature and concentration fields are studied and presented with the aid of figures. The effects of the pertinent parameters on skin friction, rate of heat transfer and mass transfer coefficients are presented in tabular form. The numerical results are compared graphically with previously published result as special case of the present investigation and results found to be in good agreement.

A Numerical Study on Heat Transfer of External Surface of Ambient Evaporators (액화가스용 기화기의 외측 열전달에 대한 수치해석 연구)

  • Seo, Dongmin;Ko, Dong Guk;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.1
    • /
    • pp.116-119
    • /
    • 2017
  • In this paper, natural convection around the ambient evaporator was numerically studied using commercial computational fluid dynamics software. From the simulations, temperature and velocity fields around the evaporator were found as a function of evaporator size and liquefied gas flow rate. The heat transfer coefficient at the external surface of the evaporator was also calculated from the simulation results. In order to give the heat transfer coefficient for various conditions, correlation between Rayleigh number and Nusselt number was proposed.

  • PDF

Application of Multivariate Adaptive Regression Spline-Assisted Objective Function on Optimization of Heat Transfer Rate Around a Cylinder

  • Dey, Prasenjit;Das, Ajoy K.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1315-1320
    • /
    • 2016
  • The present study aims to predict the heat transfer characteristics around a square cylinder with different corner radii using multivariate adaptive regression splines (MARS). Further, the MARS-generated objective function is optimized by particle swarm optimization. The data for the prediction are taken from the recently published article by the present authors [P. Dey, A. Sarkar, A.K. Das, Development of GEP and ANN model to predict the unsteady forced convection over a cylinder, Neural Comput. Appl. (2015) 1-13]. Further, the MARS model is compared with artificial neural network and gene expression programming. It has been found that the MARS model is very efficient in predicting the heat transfer characteristics. It has also been found that MARS is more efficient than artificial neural network and gene expression programming in predicting the forced convection data, and also particle swarm optimization can efficiently optimize the heat transfer rate.