• 제목/요약/키워드: Controlling Power

검색결과 1,245건 처리시간 0.03초

Optimal Power Flow of DC-Grid Based on Improved PSO Algorithm

  • Liu, Xianzheng;Wang, Xingcheng;Wen, Jialiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1586-1592
    • /
    • 2017
  • Voltage sourced converter (VSC) based direct-current (DC) grid has the ability to control power flow flexibly and securely, thus it has become one of the most valid approaches in aspect of large-scale renewable power generation, oceanic island power supply and new urban grid construction. To solve the optimal power flow (OPF) problem in DC grid, an adaptive particle swarm optimization (PSO) algorithm based on fuzzy control theory is proposed in this paper, and the optimal operation considering both power loss and voltage quality is realized. Firstly, the fuzzy membership curve is used to transform two objectives into one, the fitness value of latest step is introduced as input of fuzzy controller to adjust the controlling parameters of PSO dynamically. The proposed strategy was applied in solving the power flow issue in six terminals DC grid model, and corresponding results are presented to verify the effectiveness and feasibility of proposed algorithm.

저속 전력선통신 적용 전원공급장치의 대기전력 절감 방법 및 구현 (Method and implementation for reducing stand by power consumption in SMPS with low-speedy power line communication)

  • 김기현;손도선;김형우;서길수;김상철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1139-1140
    • /
    • 2008
  • This paper is designated to introduce the method of reducing stand-by Power of SMPS applied PLC(Power Line Communication) and its implementation. PLC modem consists mainly of PLC Module, Coupling Circuit, ZCP(Zero-Cross Point) Circuit and Power Supply Circuit. By controlling power from Power Supply Circuit to PLC Module and ZCP Circuit, the reduction of Stand-by Power is established. When this method is applied to SMPS used for a low-speed PLC, about 50% power reduction is provided, compared to the other case to which it is not applied.

  • PDF

대용량 에너지 저장장치용 전력변환기 개발 (Development of the Power Conditioning System for High Power Energy Storage System)

  • 이진희;최용길;최준영;손의권;서인영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.330-331
    • /
    • 2010
  • This paper presents the development of 800kW energy storage system. This system consist of lithium-ion batteries (LiB), power conditioning system (PCS), energy management system (EMS), and shows specification of the 800kW PCS. Furthermore, this paper presents a control methodology for controlling the combined output and the energy storage.

  • PDF

Improved LVRT Capability and Power Smoothening of DFIG Wind Turbine Systems

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.568-575
    • /
    • 2011
  • This paper proposes an application of energy storage devices (ESD) for low-voltage ride-through (LVRT) capability enhancement and power smoothening of doubly-fed induction generator (DFIG) wind turbine systems. A grid-side converter (GSC) is used to maintain the DC-link voltage. Meanwhile, a machine-side converter (MSC) is used to control the active and reactive powers independently. For grid disturbances, the generator output power can be reduced by increasing the generator speed, resulting in an increased inertial energy of the rotational body. Design and control techniques for the energy storage devices are introduced, which consist of current and power control loops. Also, the output power fluctuation of the generator due to wind speed variations can be smoothened by controlling the ESD. The validity of the proposed method has been verified by PSCAD/EMTDC simulation results for a 2 MW DFIG wind turbine system and by experimental results for a small-scale wind turbine simulator.

전원 불평형과 역률을 보상하는 직렬형 능동전력필터 (Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction)

  • 장정익;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.498-500
    • /
    • 2005
  • This paper presents a unified control scheme for series-type active power filters combined with shunt passive filters for the source voltage unbalance compensation and the power factor correction simultaneously. The power factor correction is achieved by controlling the amplitude of reactive power current in a series filter as zero in a synchronously rotating reference frame. The proposed algorithm successfully compensates the source voltage unbalance and the power factor. The validity of the proposed scheme has been verified by simulation for a 3-kVA hybrid active power filter system.

  • PDF

Efficient Maximum Power Tracking of Energy Harvesting Using a ${\mu}$Controller for Power Savings

  • Heo, Se-Wan;Yang, Yil-Suk;Lee, Jae-Woo;Lee, Sang-Kyun;Kim, Jong-Dae
    • ETRI Journal
    • /
    • 제33권6호
    • /
    • pp.973-976
    • /
    • 2011
  • This letter describes an efficient technique for maximum power point tracking (MPPT) of an energy harvesting device. It is based on controlling the device voltage at the point of maximum power. Using a microcontroller with a power saving technique, the MPPT algorithm maintains the maximum power with low power consumption. An experiment shows that the algorithm maximizes the energy transfer power using an energy management IC fabricated in a 0.18-${\mu}m$ process. Compared to direct energy transfer to a battery, the proposed technique is more efficient for low-energy harvesting under variable conditions.

가교제 및 pH 조절제가 수용성 아크릴 점착제의 점착 물성에 미치는 효과 (The Effects of Crosslinking Agent and pH Controlling Agent on Adhesive Properties of Water Soluble Acrylic PSA)

  • 서인선;박명철;이명천
    • 접착 및 계면
    • /
    • 제4권3호
    • /
    • pp.9-13
    • /
    • 2003
  • 본 연구에서는 점착제의 유지력 개선과 pH 조절을 위해 각각 첨가해 주는 가교제와 pH 조절제의 종류 및 첨가량이 수용성 아크릴 점착제의 점착 물성 및 수용성에 미치는 효과를 알아보기 위하여 중합된 점착 시료에 여러 가지의 가교제와 pH 조절를 첨가해 준 후 초기점착력, 유지력 및 점착력 등의 점착 물성과 수용성을 측정하였다. 가교제를 0.2 wt% 미만 첨가해 주었을 때, 초기 점착력은 감소하였고 유지력과 점착력은 증가하였다. 그러나 0.2 wt% 이상 첨가해 주었을 때는 초기 점착력은 증가하였지만 유지력과 점착력은 감소하는 결과를 보였다. 또한 pH 조절제를 첨가해 주었을 때 pH 조절제의 농도가 증가함에 따라 초기점착력과 수용성은 감소하였고 점착력과 유지력은 증가하였으며, LiOH, KOH, NaOH 순으로 점착 물성과 수용성에 미치는 영향이 큰 것으로 나타났다.

  • PDF

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

Bandwidth - Power Optimization Methodology for SFB Filter Design

  • Shin, Hun-Do;Ryu, Seung-Tak
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권1호
    • /
    • pp.88-98
    • /
    • 2012
  • In this paper, the relationship between the bandwidth (BW) and power efficiency of a source follower based (SFB) filter is quantitatively analyzed, and a design methodology for a SFB filter for optimized BW - power consumption is introduced. The proposed design methodology achieves a maximum BW at a target quality (Q) factor for the given power consumption constraint by controlling design factors individually. In order to achieve the target BW from the maximized BW, a tuning method is introduced. Through the proposed design methodology, a fourth order Butterworth filter was implemented in 0.18 ${\mu}m$ CMOS technology. The measured BW, power consumption, and IIP3 are 100 MHz, 33 ${\mu}W$, and 9 dBm, respectively. Compared with other filter structures, the measured results show high BW - power efficiency.