• 제목/요약/키워드: Controlled Cooling Rate

검색결과 107건 처리시간 0.022초

냉각수 및 오일의 온도에 따른 연비향상에 관한 실험적 연구 (An Experimental Study on the Improvement of Fuel Economy according to Coolant and Oil Temperature)

  • 조원준;김형익;이기형
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.72-79
    • /
    • 2009
  • Recently, the internal combustion engines have focused on reducing the $CO_2$ gas in order to cope with severe regulations for fuel economy. Therefore, various new technologies have been developed. Among them, cooling system is spotlighted because it has great effect on fuel economy. In this study, we measured the friction losses of engine parts according to engine speed and oil temperature. We also obtained optimized oil temperature which has the minimum friction losses. Then, we selected optimized oil temperature range and gave informations of friction losses for each engine parts. In addition, we analyzed relationship between coolant temperature and oil temperature by using engine performance test system. From this experiment, we obtained the database for relationship between coolant temperature and oil temperature. Then, we found the optimal temperature about engine oil. We analyzed BSFC and exhaust emissions by controlling the high coolant temperture. If we controlled coolant temperature more higher, BSFC has a little difference but exhaust emissions such as THC and CO have reduced. By using these experimental results, we predicted that IC engine have more low fuel consumption and exhaust emissions by optimized cooling control strategy.

화염경화 표면처리 공정에 의한 12Cr 강의 잔류응력 거동 (Behavior of the Residual Stress on the Surfaces of 12Cr Steels Generated by Flame Hardening Process)

  • 이민구;김광호;김경호;김흥회
    • 한국표면공학회지
    • /
    • 제37권4호
    • /
    • pp.226-233
    • /
    • 2004
  • The residual stresses on the surfaces of low carbon 12Cr steels used as a nuclear steam turbine blade material have been studied by controlling the flame hardening surface treatments. The temperature cycles on the surfaces of 12Cr steel were controlled precisely as a function of both the surface temperature and cooling rate. The final residual stress state generated by flame hardening was dominated by two opposite competitive contributions; one is tensile stress due to phase transformation and the other is compressive stress due to thermal contraction on cooling. The optimum processing temperatures required for the desirable residual stress and hardness were in the range of $850^{\circ}C$ to $960^{\circ}C$ on the basis of the specification of GE power engineering. It was also observed that the high residual tensile stress generated by flame hardening induced the cracks on the surfaces, especially across the prior austenite grain boundaries, and the material failure virtually, which might limit practical use of the surface engineered parts by flame hardening.

상용차 하이브리드 냉방시스템 냉방 성능 특성 연구 (Experimental study on cooling performance characteristics of hybrid refrigeration system in a heavy duty vehicle)

  • 이호성;전한별;김정일;이무연
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.419-425
    • /
    • 2019
  • 본 연구의 목적은 상용차 운행 시, 야간 및 운휴중에 냉방시스템을 운전하기 위하여서, 기계식과 전동식 압축기를 적용한 하이브리드 냉방시스템에 대한 냉방성능 특성을 분석하는 것이다. 기계식압축기는 170cc의 왕복동 형식이고, 전동식 압축기는 18cc 스크롤 형식이다. 전동식 압축기는 운휴시나 야간에 사용할 목적으로 적용되었기 때문에, 냉방용량은 기계식 압축기 대비 낮은 성능을 가지고 있다. 기계식 압축기를 사용하였을 경우, 6.0kW 수준의 냉방성능을 보이고 있고, 시스템 효율은 2.0이하의 결과를 가졌다. 반면, 전동식 압축기는 냉방성능 4.0kW수준, 시스템 효율은 3.5 수준을 가지고 있었다. 본 연구에서는 전동식 압축기는 냉방성능 4.0kW수준, 시스템 효율은 3.5 수준을 가지고 있었다. 기계식 압축기와 전동식 압축기를 운전조건에 따라서, 선택적으로 운전하는 것을 고려하였기 때문에, 운전모드가 바뀔 때의 시스템 특성을 분석하기 위하여서, 운전모드 변경에 대한 영향을 알아보았다. 운전모드가 변경될 때, 토출압력이 일시적으로 증가하는 경향을 보이는데, 안정적인 운전을 위하여서, 외기 부하 등을 고려한 운전모드 변경 로직에 대한 연구가 필요할 것으로 판단된다.

수정된 열교환법에 의한 sapphire 단결정의 성장 : I. 사각단면 단결정의 제조 (Sapphire single crystal growth by the modified heat exchanger method : I. Preparation with the square cross-section)

  • 이민상;김성균;김동익;진영철
    • 한국결정성장학회지
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 1998
  • 본 연구에서는 냉각매체로서 물을 이용하는 수정된 열교환법을 이용하여 45$\times$45$\times$20(mm) 크기의 사각단면 형상의 sapphire 단결정의 제조가능 조건에 대하여 조사하였다. 온도에 따른 성장로 내의 압력 변화로부터 사파이어의 용융 및 응고 과정을 추적할 수 있었으며, 이로부터 sapphire 단결정은 1970~$1960^{\circ}C$에서 응고가 완료됨을 알 수 있었다. 도가니 성형시 이루어지는 '귀'의 형태는 도가니 벽면과 접촉되지 않는 '나선형태'이어야 한다. 열유출부는 융액 내의 온도구배를 지배하며 융액내의 열유속과 씨앗 결정의 흔적은 Mo 봉의 체적 변화로서 조절할 수 있었다. 기공 형성을 억제하기 위해서는 $0.2^{\circ}C$/min 이하의 발열체의 냉각속도가 요구되었다.

  • PDF

전자 밸브에 의해서 제어되는 히트파이프의 전열 특성 (Characteristics of Heat Transfer in a Heat pipe Controlled by Solenoid Valve)

  • 전철호;장영석;김오근
    • 태양에너지
    • /
    • 제17권1호
    • /
    • pp.103-111
    • /
    • 1997
  • 본 연구에서는 히트파이프의 제어를 전자밸브에 의하여 단속 되어질 때 증발부의 상태변화가 응축부에 미치는 전열제어 특성을 연구한 것이다. 증발부와 응축부사이의 단열부에 전자밸브를 설치하여 증발부의 열저장에 따른 밸브제어의 영향, 밸브주기 개폐에 따른 응축부의 응답특성, 경사도, 입열량, 냉각수량변화가 전열에 미치는 연구를 실행하고 증발부와 응축부의 유동특성을 고찰하여 전자제어밸브에 따라 증기의 동특성영향을 연구한다. 그 결과는 응축부와 증발부사이의 온도차가 크면 온도의 진동수는 증가하고, 온도의 진폭은 감소한다. 제어밸브의 개폐시간이 지연되면 증발부의 펄스비등은 강하게되고 밸브개폐후 응축부의 온도 진동은 지연 감쇄한다.

  • PDF

퍼지논리를 이용한 저온저장고의 온도제어시스템 개발 (Development of Temperature Control System for Cold Storage Room Using Fuzzy Logic)

  • 양길모;고학균;조성인
    • Journal of Biosystems Engineering
    • /
    • 제25권2호
    • /
    • pp.107-114
    • /
    • 2000
  • Low temperature storage method is to increase the value of agricultural products by reducing quality loss and regulate consignment time by controlling respiration rates of agricultural products. Respiration rate of agricultural products depends on several factors such as temperature, moisture, gas composition and a microbe inside the storage room. Temperature is the most important factor among these, which affects respiration rate and causes low or high temperature damage. Fuzzy logic was used to control the temperature of a storage room ,which uses information of uncertain facts and mathematical model for room temperature control . Room temperature was controlled better by using fuzzy logic control method rather than on-off control method. Refrigerant flow rates and temperature deviations were measured for on-off system using TEV(temperature expansion valve) and for fuzzy system using EEV(Electrical Expansion Valve) . Temperature of the Storage room was lowered faster by using fuzzy system than on -off system. Temperature deviation was -0.6~+0.9$^{\circ}C$ for on-off system and $\pm$0.2$^{\circ}C$ for fuzzy system developed. Temperature deviation and variation of temperature deviation were used as inout parameters for fuzzy system. The most suitable input and output value were found by experiment. Cooling rate of the storage room decreased while temperature deviation increased for the sampling time of 20 sec.

  • PDF

엔진 냉각수 유량 단속에 의한 디젤 차량의 연비 및 배기가스 특성 연구 (A Study on the Characteristics of Fuel Consumption and Emissions of Diesel Vehicles Using Engine Coolant Flow Rate On/Off Control)

  • 김성철
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2069-2074
    • /
    • 2013
  • 내연기관 차량에 전자기식 클러치 워터펌프의 적용은 연비 향상 및 배기가스 저감을 꾀할 수 있다. 이러한 클러치 워터펌프는 엔진 냉각시스템의 유량 단속에 의하여 최적 운전 조건을 가능케 한다. 본 연구에서는 클러치 워터펌프를 이용한 냉각시스템을 제어함으로써 디젤 차량의 연비 및 배기가스 특성을 살펴보았다. 전자기식 클러치 워터펌프에 의한 저온 시동시 냉각수 흐름을 차단하여 아이들 조건에서 예열 시간을 기존 워터펌프 대비 49% 정도 단축시켰고, 주행 중에는 냉각수가 최적 고온상태를 유지하도록 제어하였다. 그리하여 NEDC 모드에서 연소 효율이 개선되어 최대 5% 정도의 연비 향상 효과를 나타내었다. 또한 NOx를 제외한 HC, CO 및 $CO_2$ 배기가스의 농도가 전반적으로 감소하였다.

오픈 캐소드형 고분자전해질 연료전지의 성능향상과 회복기법 (Performance Enhancement and Recovery Method of Open Cathode PEMFC)

  • 이기택;김준범
    • 공업화학
    • /
    • 제28권1호
    • /
    • pp.118-124
    • /
    • 2017
  • 공랭식 고분자전해질 연료전지는 개방된 cathode구조로 인하여 시스템의 단순화와 부품 수 저감의 장점이 있다. 공랭식 연료전지는 최근에 많이 연구되고 있지만, 성능이 외부 환경에 영향을 받으며, 공기의 상대습도가 낮은 경우 전해질막의 건조로 인한 성능 감소가 발생할 수 있다. 본 연구에서는 공랭식 연료전지의 성능에 영향을 주는 요인인 cathode 측 공기 유량과 anode 측 purge interval영향에 대해 분석하였으며, 스택을 운전하지 않는 상태로 장기간 보관하는 것이 성능에 미치는 영향에 대하여 실험을 수행하였다. 연료전지 외부에 설치한 fan의 전압을 조절하면 cathode 측 공기의 공급유량을 변화시킬 수 있고 스택의 온도도 제어할 수 있으므로, fan전압은 공랭식 연료전지의 성능에 영향을 주는 중요한 인자이다. 연료전지 시스템을 단순화하고 수소의 사용률을 높이기 위하여 anode 측은 dead ended anode (DEA) 기법을 사용하였다. 주기적인 purge를 실행하여 생성된 물과 가스를 배출하였으며, purge 주기를 변경하면서 스택의 성능에 미치는 영향에 대하여 실험을 수행하였다. 스택의 보관기간이 길어질수록 membrane dehydration으로 인해 성능이 감소하는 것을 실험을 통해 파악하였고, 단시간에 성능을 회복할 수 있는 기법을 제시하였다.

퍼지 적용 PID제어를 이용한 오일쿨러 시스템의 온도제어 (Temperature Control for an Oil Cooler System Using PID Control with Fuzzy Logic)

  • 김순철;홍대선;정원지
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.87-94
    • /
    • 2004
  • Recently, technical trend in machine tools is focused on enhancing of speed, accuracy and reliability. The high speed usually results in thermal displacement and structural deformation. To minimize the thermal effect, precision machine tools adopt a high precision cooling system. This study proposes a temperature control for an oil cooler system using Pill control with fuzzy logic. In the cooler system, refrigerant flow rate is controlled by rotational speed of a compressor, and outlet oil temperature is selected as the control variable. The fuzzy control rules iteratively correct PID parameters to minimize the error and difference between the outlet temperature and the reference temperature. Here, ambient temperature is used as the reference one. To show the effectiveness of the proposed method, a series of experiments are conducted for an oil cooler system of machine tools, and the results are compared with the ones of a conventional Pill control. The experimental results show that the proposed method has advantages of faster response and smaller overshoot.

U-Healthcare시스템을 위한 PPG의 피부표면의 온도변화보상 (Compensation of Skin Surface Temperature Variation on the PPG for the U-Healthcare System)

  • 염호준
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.319-324
    • /
    • 2011
  • 본 논문에서는 혈압과 광용적맥파, 국부피부온도변화에 따른 심혈관 파라메터의 통계적 변화와 관계에 대해 연구하였다. 국부피부온도변화는 Finometer의 혈압, 광용적맥파 그리고 총말초저항에 영향을 주었고 오실로메트릭 혈압, 심박수, 심박출량에는 영향을 주지 않는 결과를 얻었다. 그러므로 온도변화가 있는 환경에서 에러를 줄이기 위해 심혈관계의 상태를 광용적맥파로 평가하기위해서는 온도를 제어하거나 보상해 주어야 한다.