• Title/Summary/Keyword: Control signal line

Search Result 490, Processing Time 0.102 seconds

The Decision of the Optimal Shape of Inductive Loop for Real-Time Traffic Signal Control (실시간 교통신호제어를 위한 루프 검지기의 최적형태결정에 관한 연구)

  • 오영태;이철기
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.3
    • /
    • pp.67-86
    • /
    • 1995
  • It requires the detector system which can collect highly reliable traffic data in order to perform the real-time traffic signal control. This study is to decide the optimal shape of inductive loop for the real-time traffic signal control .This loop is located at the stopline in the signalized intersection for DS(Degree of Saturation) control. In order to find out the optimal shape of loop, 6types of experiments were performed . The results of the basic experiments of loops are as follows ; -the optimal number of turns for loop is 3 turns. -the impedance values of the loop detectors are similar to that of NEMA standards -the 1.8${\times}$4.5M loop is excellent for sensitivity in actual detection range of car length comparing to other shape of inductive loops. At the experimental of establishments of the optimal loop shape, it found that 1.8 4.5M loop has the highest values of $\DeltaL$ comparing to other types of loops, It means that the range of Lead-in cable length of this loop. And this loop is highly reliable in occpupancy time. Conclusivley, the 1.8${\times}$4.5M inductive loop is the optimal solution as a stop line loop detector for real -time traffic signal control.

  • PDF

Development of a Monitoring Equipment of Current and Potential on Power Transmission Line for 66kV

  • Nisiyama, Eiji;Kuwanami, Kenshi;Kawano, Mitsunori;Matsuda, Toyonori;Oota, I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.41-44
    • /
    • 2003
  • We propose portable equipment that monitors current and voltage of high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to an insulator that supports a power transmission line: A clamped to the power line and the detected current signal is transmitted to the ground station by a wireless optical link using transmission line is detected by a high resistance element, zinc oxide (ZnO). That acts as a potential divider between the power line and ground. We make an experimental device for 66kV power line and demonstrate that it can monitor currents proposed equipment is small-sized, light, and inexpensive in comparison with the conventional CT (current transformer) and PT (potential transformer) since it does not require high potential insulators and magnetic cores, further, the equipment is easily installed owing to its small size and its simple structure.

  • PDF

A Development of Stroke Sensing Cylinder for Position Control Using Magnetic Sensor (I) (자기센서를 이용한 위치제어용 스트로크 측정 실린더 개발(I))

  • Lee, M.C.;Choi, Y.J.;Lee, M.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.136-144
    • /
    • 1996
  • We developed a part of stroke sensing cylinder for position control of automatic excavator and its measurement system. In this paper, for development of stroke sensing cylinder, we consist of 2-axis control instrument system with Hall sensor. A performance of piston rod with magnetic scales is evaluated by the developed measurement system. Furthermore, the position control for good performance of instrument system is achieved by a sliding mode control which is a new method diminishing the chattering in that control by setting 2-dead band along the swtching line. The unknown parameters for sliding mode control are estimated by the signal compression method.

  • PDF

An Indirect Model Reference Adaptive Fuzzy Control for SISO Takagi-Sugeno Model

  • Cho, Young-Wan;Park, Chang-Woo;Lee, Ki-Chul;Park, Mignon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.1
    • /
    • pp.32-42
    • /
    • 2001
  • In this paper, a parameter estimator is developed for the plant model whose structure is represented by the Takagi-Sugeno model. The essential idea behind the on-line estimation is the comparison of the measured stated with the state of an estimation model whose structure is the same as that of the parameterized model. Based on the parameter estimation scheme, and indirect Model Reference Adaptive Fuzzy control(MRAFC) scheme is proposed to provide asymptotic tracking of a reference signal for the systems with uncertain for slowly time-varying parameters. The developed control law and adaptive law guarantee the boundedness of all signals in the closed-loop systems. In addition, the plant state tracks the state of the reference model asymptotically with time for any bounded reference input signal.

  • PDF

Active noise control with the active muffler in automotive exhaust system (액티브 머플러를 이용한 자동차 배기계의 능동소음제어)

  • Kim, Heung-Seob;Hong, Jin-Seok;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1837-1843
    • /
    • 1997
  • This study experimentally demonstrates the use of active muffler attached to the automotive exhaust system to reduce exhaust noise. For improving the signal to noise ratio in the process of estimation of secondary path transfer functions, the on-line algorithm that conventional inverse modeling is combined with adaptive line enhancer is used as the control algorithm. Active muffler is designed that the primary noise and the control sound are propagated as a plane wave in the outlet. Therefore, the error microphone could be placed out of the tail pipe center of a high temperature and the radiation noise to the outside could be reduced in the whole area around the outlet. The control experiment for reducing exhaust noise with active muffler is implemented during run-up at no load. From the experimental results presented, compared with the conventional off-line method, the proposed on-line method is capable to acquire a reduction of exhaust noise above 5 dB in overall sound power level.

A Method for Fault detecting on Power Transmission Network by use of M-sequence Correlation

  • Nishiyama, Eiji;Kuwanami, Kenshi;Owaki, Kosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2570-2575
    • /
    • 2003
  • Monitoring a power transmission line is significant for power electric companies. In this paper, we propose a new method for detecting an fault point of power transmission line by use of M-sequence correlation technique. In this method, detecting signal is used as one or plural M-sequences ( same characteristic polynomial, including normal and reverse mark, synchronized ). In receiving point, we make same sequence with the input one and take crosscorrelation function between M-sequence and the received signal. We can see transfer fanctions of plural paths between inputs and a output taps separated from different of delay times on the crosscorrelation function, and from these transfer fanctions, so we compare them when fault occurred with in usual.

  • PDF

Principal and Application of Velocity Detection Signal Device Applied in Tarin Control System of Maglev Train (자기부상열차 열차제어시스템에 적용되는 속도검출장치 원리 및 적용사례)

  • Kim, Young-Taek;Cho, Dong-Il;Lee, Oh-Hyun;Park, Hee-Jun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1108-1114
    • /
    • 2011
  • In general, railway system uses wheels so detecting speed by tachometer. However, LRT(Light Rail Transits) stands out recently as alternatives transportation, and besides of that Maglev trains are emerged as an alternative means of transportation. Maglev operates above certain heights caused inability of the measurement by tachometer which used to detect speed of wheels. Velocity Detection Signal Device of Train Control System applied in "Train Control System Project of Pilot Line Construction for Urban MAGLEV Train" which is prepared ahead of opening in 2013. This paper, therefore, explains the function and operation principal of Velocity Detection Signal Device, and suggests installation method of velocity detection loop installed around the track.

  • PDF

Simualation of PFM control signal for optical fiber transmission

  • Komatsu, Takeshi;Ikeda, Hiroaki;Li, Jinzhu;Aoki, Kazuya;Yoshida, Hirofumi;Shinohara, Shigenobu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1116-1118
    • /
    • 1990
  • This paper describes the required frequency bandwidth which is used as a measure for the quality of the PFM transmission system to transmit the control signals. First, the PFM signal which has been distorted due to the frequency bandwidth limit on the transmission line is analyzed by Fourier transform and secondly distortion which has been observed at the receiver is numerically analyzed to make the frequency bandwidth required for transmitting the PFM signals. According to the analysis heretofore, the 50% threshold level for shaping the received PFM signal, which is of 50 % in TTL level, is superior than the 10- and 90-% threshold levels.

  • PDF

Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module (ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Park, Jong-Taek;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

A Study on Operating Position Sensing System of Pull Cord Switches Using Power Line Communication (전력선 통신을 이용한 풀 코드 스위치의 동작위치 인식 시스템에 대한 연구)

  • Choi, Nam-Sup;Lee, Buhm
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.745-748
    • /
    • 2003
  • This paper presents a study on pull cord switch system which is employed in various industry for emergency stop of the equipments. By using power line communication(PLC) technique, in this paper, a new method for operation position detection of pull cord switch is suggested without complicated wiring of separate cables which utilize only 2 lines. Also, using control function of PLC IC, a reset signal for each switch reset can be implemented in the switch status control/sensing device. Finally, this paper shows validity and practical applicability of the proposed operating position sensing system of pull cord switch by implementing the system and revealing the response time and signal through the PLC line.

  • PDF