• Title/Summary/Keyword: Control overflow load

Search Result 13, Processing Time 0.032 seconds

Comparison of Pollutant Control in Combined Sewer Overflows and Separated Sewer Overflows using the Separation Wall (우오수분리벽을 이용한 합류식 하수관거와 분류식 우수관거의 월류수 제어효과 비교)

  • Lim, Bong-Su;Kim, Do-Young;Lee, Kuang-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.458-466
    • /
    • 2007
  • This study is to evaluate control effects of separation wall by surveying water quality and sewer overflows during dry and wet periods in combined sewer and separated sewer systems. Ravine water from the combined Seokgyo outfall with the separation wall was separated about four times larger than sewage flow during dry periods. The water quality of the combined Seokgyo outfall with separation wall during dry periods is flow weighed average BOD 61 mg/L, the combined Cheonseokgyo outfall without the separation wall is average BOD 71 mg/L, and the separated Pyeongsong center outfall is average BOD 41 mg/L. The BOD concentration in separated outfall form about 57% of the combined outfall, and this means the separated outfall (i.e. storm sewer) is polluted by inflow of sewage. The overflow load of the separated outfall is ten times higher than the combined outfall and its overflow load per rainfall is three times than combined outfall during the wet periods. Therefore, the control plan of overflow load is required in storm sewer. The control effects of the overflow load increased 79% by setting the separation wall in the combined sewer, and showed 27% increase without the separation wall in separated sewer, but forecasted over 80% increase of effects if the separation wall was set.

Overflow Valve and Performance Evaluation System for Diesel Cars based on Spring Load (스프링하중을 고려한 디젤차량용 오버플로우 밸브 성능평가)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.200-204
    • /
    • 2016
  • In this paper, we have estimated the performance of an overflow valve for EURO type CRDI(common rail direct injection) engine. In order to implement the overflow valve with friendly circumstance, it is necessity for considering spring load. Especially, the performance evaluation of diesel car with accuracy control will be considered a mileage improvement and circumstance regulation. In order to evaluate the performance of overflow valve, The leak test system checks the pressure, switching time and operating time under 3.0 bar below 100 cc, 3.3 bar among 150 cc and 200 cc, finally 4.0 bar upper 250 cc.

Control of the Sediment in a Combined Sewer Using a Separation Wall

  • Lim, Bong Su;Kwon, Chung Jin;Kim, Do Young;Lee, Kuang Chun
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.71-75
    • /
    • 2013
  • This study is to evaluate the effects of the separation wall on the sediment quality and quantity in a combined sewer, by surveying the sewer overflow and sediments during a rainfall. Since the separation wall installed in the combined sewer separates the rainfall and the sewage, the flow rate of the sewage is increased, and the amount of the sediment deposited on the sewer is decreased. One sampling point was the outfall of Daesacheon with a separation wall, and the other was the outfall of Gwaryecheon without a separation wall, in Daejeon metropolitan city. The maximum control of the biochemical oxygen demand (BOD) overflow load was more than 38% in the Daesacheon point with the separation wall, during a rainfall of 0.11 mm/hr. The maximum control of the BOD overflow load was 24% in Gwaryecheon without a separation wall, during a rainfall of 1.0 mm/hr. According to the survey results of the sediment in the sewer, the discharged sediment deposited on the sewer in Gwaryecheon point was about 23% to 28% of the total suspended solid during the rainfall. In addition, the average velocity of sewage in the presence of sediment was about 0.30 m/s, and if the separation wall is installed, it was expected to be about 1.01 m/s, that is 3.4 times more than the same conditions, resulting in the reduction of the sediment deposit.

A study on the overload control of the ATM switching system (ATM 교환기 과부하제어 연구)

  • 기장근;최진규;김영선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.952-960
    • /
    • 1996
  • In this paper, a new overload control scheme is proposed for a control system in ATM switching system. The proposed control scheme includes a counter that conunts the number of accepted calls and is decreased at cach D time interval. In overload condition of call processor, the control scheme detects over load condition when the counter value reaches a certain threshold value. Under overload condition, processor utilization is measured and the value of the D is updataed according to the difference between measured processor utilization and target utilization. A new call is accepted accepted only if the value of the counter is less than the threshold value. In overflow condition of cell traffic, accept probability of new call is reduced exponetially according to the elapsed time. The results of simulation show that the proposed overload contorl scheme maintains the target utilization very well under the various processor overload conditions and reduces the cell loss probability under the cell overflow conditions.

  • PDF

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

A Study for Flow-rate Balancing when the System Resistance Changes in the Control of the Radiant Floor Heating System (온돌난방제어 시 시스템저항 변화에 따른 유량 밸런싱에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Kwang-Woo;Yeo, Myoung-Souk
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.129-134
    • /
    • 2005
  • The behavior of whole system is affected by a minor change of system in the hydronic radiant floor heating system. Under partial load condition, the change of system resistance causes overflow of supply water. This unexpected effect is the cause of several problems in the heating system. In this study, we find some factors were validated with several computer simulations. After validation of this result, several conceptual solutions are evaluated to prevent overflow.

  • PDF

A Study on the Call Admission Control with Overflow and Preemption at Adaptive Moving Boundary in Cellular Mobile Communications (셀룰러 이동통신망의 적응성 가변경계에서 Overflow와 Preemption을 갖는 호 접속제어 방안 연구)

  • 노희정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.171-180
    • /
    • 2004
  • CDP(handoff Call Dropping Probability) and CBP(new Call Blocking Probability) have been used as two important call level QoS parameters in cellular mobile communications. But, many methods to reduce CDP without considering CBP have been studied, and hand-off call priority scheme has been introduced. But the use of hand-off call priority scheme increases CBP and decreases channel utilization rate depending on the number of reserved channel for priority. In this paper, we propose a CAC(Call Admission Control) algorithm with overflow and preemption to solve the problem caused by considering CDP and CBP in calculation of the number of channel reserved. The problem is the increase of CDP as the traffic load increases. In our CAC algorithm, hand-off call is permitted to use(overflow) unreserved and unused channel if there is no reserved and unused channel, and new call is permitted to use(preemption) the channel overflowed by hand-off call if there is no unreserved and unused channel. This mechanism of calculation of the number of reserved channel and CAC algorithm is expected to increase channel utilization rate, and can be applied to media-based QoS provision in cellular mobile communications.

Auto Regulated Data Provisioning Scheme with Adaptive Buffer Resilience Control on Federated Clouds

  • Kim, Byungsang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.11
    • /
    • pp.5271-5289
    • /
    • 2016
  • On large-scale data analysis platforms deployed on cloud infrastructures over the Internet, the instability of the data transfer time and the dynamics of the processing rate require a more sophisticated data distribution scheme which maximizes parallel efficiency by achieving the balanced load among participated computing elements and by eliminating the idle time of each computing element. In particular, under the constraints that have the real-time and limited data buffer (in-memory storage) are given, it needs more controllable mechanism to prevent both the overflow and the underflow of the finite buffer. In this paper, we propose an auto regulated data provisioning model based on receiver-driven data pull model. On this model, we provide a synchronized data replenishment mechanism that implicitly avoids the data buffer overflow as well as explicitly regulates the data buffer underflow by adequately adjusting the buffer resilience. To estimate the optimal size of buffer resilience, we exploits an adaptive buffer resilience control scheme that minimizes both data buffer space and idle time of the processing elements based on directly measured sample path analysis. The simulation results show that the proposed scheme provides allowable approximation compared to the numerical results. Also, it is suitably efficient to apply for such a dynamic environment that cannot postulate the stochastic characteristic for the data transfer time, the data processing rate, or even an environment where the fluctuation of the both is presented.

Developing Dynamic Scheduling Algorithm of VoD Server Server System Performance (시스템 성능 향상을 위한 VoD서버의 능동 스케줄링 알고리즘 개발)

  • 김정택;고인선
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.65-65
    • /
    • 2000
  • For Video on Demand(VoD) servers, a design of an efficient scheduler is important to the support a large number of clients having various playback speeds and receiving rates. In this paper, we propose the scheduling algorithm to handle establishing deadlines and selection using the earliest deadline first. To establish deadlines and selections, the period of the receiving rates for each client is located between the over-max receiving rate and the over-playback rate. To avoid video starvation and the buffer overflow of each client, the proposed algorithm guarantees providing the admission control. Because of establishing deadlines and selection, period of each client receiving is between one over max receiving rate and one over play back rate. Using Virtual Buffer in server, scheduling load is reduced. The efficiency of the proposed algorithm is verified using a Petri Net_Based simulation tool, Exspect.

  • PDF

Design of Digital Filter One Chip I.C (DIGITAL FILTER ONE CHIP I.C.화 및 제작)

  • Park, Sang-Bong;Pack, In-Cheon;Park, Noo-Kyeong;Moon, Dait-Chul;Tchah, Kyun-Hyon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1495-1498
    • /
    • 1987
  • This paper described the design of register part, ROM and entire digital filter implementation by merging with ALU, control part last year. The register part consists of shift register, parallel load serial output register, multiplexer and selector, and we designed specially the 1024 memory cells ROM and decoder to decode the register data. Also, presented scaling algorithm to prevent the overflow.

  • PDF