A Study on Improved Heating Performance of an Apartment Housing Unit (공동주택 세대별 난방 성능 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

Study of Temperature Dynamic Characteristics of Various Control Methods for MGO Chiller System (MGO Chiller 시스템의 제어 방식에 따른 온도 동특성 연구)

  • Cho, Hee-Joo;Kim, Sung-Hoon;Choi, Jungho
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.139-145
    • /
    • 2019
  • It is important that an MGO Chiller System, which is one of the sulfur oxide emission control technologies, is designed to meet the fuel temperature requirements, even with sudden engine load changes. Three different control algorithms (PI, Cascade, and MPC) were applied to an indirect MGO chiller system to compare and analyze the outlet temperature dynamic characteristics of the system through a case study. The results showed that the MPC control method had the best temperature following characteristics in the case study, and the temperature deviation range was reduced by approximately 5% compared to the PI control method.

A Temperature Management of Mass Concrete for Crack Control in Machine Foundation (기계기초 매스콘크리트의 균열제어를 위한 온도관리)

  • 허택녕;이제방;손영현
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.394-401
    • /
    • 1996
  • This paper persents the crack control of mass concrete in massive machine foundation. The dimension of the machine foundation is 52.6m$\times$14.4m$\times$8.5m. The one distinctive characteristic of mass concrete is thermal behavior. Since the cement-water reaction is exothermic by nature, the temperature rises inside the massive concrete structure. When the heat is not quickly dissipated, it can be quite high. Significant tensile stresses may develop from the volume change associated with the increase of decrease of temperature within the mass concrete structure. To avoid occurrence of harmful cracks due to hydration heat, special attention shall be given to the construction of mass cnocrete structures. The temperature control system of mass concrete is proposed in this paper. This system contains a discussion of materials and concrete mix proportioning, thermal analysis, curing method, temperature control, and measurement of hydration heat. As will be seen throughout the paper, the proposed temperature control system have a great effect on the temperature-related cracks on mass concrete structures.

  • PDF

Study on application of domestic development DCS for S/H temp in the power plant (발전소 과열증기 온도제어 시스템의 국산 DCS 적용에 관한 연구)

  • 박익수;김은기;박성혁;이기원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.292-296
    • /
    • 1992
  • There are lots of disturbance in the super heater temperature control system of power plant boiler as follows. 1.Burner light off. 2.Excess Air. 3.Burner tilt. 4.G.R fan flow. Temperature control system of super heater in the power plant has delay time about 5 min. So it is difficult to control the super heater temperature in the power plant. This paper show us the application of domestic development DCS to control the super heater temperature in seoul #5 thermal power plant unit.

  • PDF

Actuator multiple control method for greenhouse environment control system (온실 환경 제어시스템을 위한 액추에이터 복합 제어 방법)

  • Son, Kyo-Hoon;Park, Dae-Heon;Kim, Se-Han;Kim, Jae-Hyung;Jeung, Eun-Tae
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.11 no.2
    • /
    • pp.39-45
    • /
    • 2012
  • In recent years the USN(Ubiquitous Sensor Networks) technology has been applied in the greenhouse in order to control temperature and humidity automatically. In this paper, we proposed a control algorithm using feedback linearization techniques based on a mathematical model for temperature and humidity environment. Especially, Control algorithm is presented to the operation of the ventilator affecting on the temperature and humidity system at the same time. The System has been designed taking into account the disturbance(External temperature, soil temperature, external humidity, solar radiation and wind). In conclusion, I will present a way to control multiple actuator through simulations. The proposed control algorithm is validated using the Matlab/Simulink tools.

  • PDF

A Study of Superheater Temperature Control on an Once Through Boiler in Thermal Power Plant (화력발전소 관류보일러의 과열기 온도제어에 관한 연구)

  • Lee, Jo-Hyun;Jeong, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2022-2027
    • /
    • 2009
  • An supercritical once through boiler system has been used in the korea standard-type thermal power plant. It is critical in boiler operation that superheater temperature should be controlled within the specified limit. In this paper, control logic scheme is suggested for superheater temperature in once through boiler. Finally the simulation result using process model based simulator shows the validity of suggested control logic.

Change in the Plant Temperature of Tomato by Fogging and Airflow in Plastic Greenhouse (포그분사 및 공기유동에 의한 온실재배 토마토의 엽온 변화)

  • Nam, Sang-Woon;Kim, Young-Shik;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • To investigate the influence of surrounding environment on the plant temperature and examine the effect of plant temperature control by fogging and airflow, plant temperature of tomato, inside and outside air temperature and relative humidity, solar radiation and wind speed were measured and analyzed under various experimental conditions in plastic greenhouse with two-fluid fogging systems and air circulation fans. According to the analysis of plant temperature and the change of inside and outside air temperature in each condition, inside air temperature and plant temperature were significantly higher than outside air temperature in the control and shading condition. However, in the fogging condition, inside air temperature was lower or slightly higher than outside air temperature. It showed that plant temperature could be kept with the temperature similar to or lower than inside air temperature in fogging and airflow condition. To derive the relationship between surrounding environmental factor and plant temperature, we did multiple regression analysis. The optimum regression equation for the temperature difference between plant and air included solar radiation, wind speed and vapor pressure deficit and RMS error was $0.8^{\circ}C$. To investigate whether the fogging and airflow contribute to reduce high temperature stress of plant, photosynthetic rate of tomato leaf was measured under the experimental conditions. Photosynthetic rate was the highest when using both fogging and airflow, and then fogging, airflow and lastly the control. So, we could assume that fogging and airflow can make better effect of plant temperature control to reduce high temperature stress of plant which can increase photosynthetic rate. It showed that the temperature difference between plant and air was highly affected by surrounding environment. Also, we could estimate plant temperature by measuring the surrounding environment, and use it for environment control to reduce the high temperature stress of plant. In addition, by using fogging and airflow, we can decrease temperature difference between plant and air, increase photosynthetic rate, and make proper environment for plants. We could conclude that both fogging and airflow are effective to reduce the high temperature stress of plant.

Precise Temperature Control by Locking on the Fixed point of Gallium (갈륨의 고정점을 이용한 정밀 온도제어)

  • 김태호;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.351-354
    • /
    • 2002
  • The new enhanced method of temperature control need not any reference temperature, the system itself can find the melting temperature of gallium as a reference point by dithering input heat flux. If gallium is in melting state, the latent heat of fusion works, so gallium temperature does not change on dithering input heat flux. Also, the control method can determine the state of gallium; solid, liquid, or melting state by investigating the temperature in gallium. We apply this new temperature stabilization method to stabilize a Fabry-Perot cavity, which serves as a ultimate length measurement technique. We achieved 1 mK-temperature stability and 1.5426 nm/ 95 mm-length stability over 10 hours.

  • PDF

The Design of an Automatic System for Dairy Cattle Breeding I - The Choice of Temperature Sensor for Body Temperature Measuring - (낙농의 자동화 시스템 구성 I - 체온 감지 온도센서의 선정 -)

  • 김형주;정길도;한병성;김용준;김동원;김명순
    • Journal of Biosystems Engineering
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 1998
  • In this paper the automatic system for dairy cattle has been desisted such as body temperature measuring unit, feed supplying unit and temperature control unit. Since e disease is strongly related to the body temperature of cattle, early detection of the abnormal temperature would prevent the severe problems which nay occur in dairy farms. An electronic component AD590J is used as temperature sensor for the system, The device is highly robust against the noise since the output signal is the current so it can be applied to a long distance sensing The resolution of signal is 0.1$^{\circ}C$ and the current is 10㎷ Also 12-bit A/D converter is desisted fir interfacing the sensor with a one-chip microprocessor. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of dairy cattle properly. A geared AC motor is used for the feed supplying unit The heater and fm are used as temperature control unit. The feed supplying unit and temperature control unit are well operating in the laboratory experiment.

  • PDF

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF