• Title/Summary/Keyword: Control of separation

Search Result 1,035, Processing Time 0.033 seconds

Control of Reactive Dividing Wall Column for the Recovery of Lactic Acid (젖산회수를 위한 분리벽형 반응증류탑의 제어)

  • Choi, Yu-Mi;Woo, Dae-Sik;Cho, Hoon;Han, Myung-Wan
    • Korean Chemical Engineering Research
    • /
    • v.49 no.3
    • /
    • pp.306-313
    • /
    • 2011
  • Lactic acid is widely used in the food, chemical and pharmaceutical industries, and there is an increasing demand for lactic acid as the raw material of polylactic acid, which is a biodegradable polymer. The presence of high boilers and non volatility of lactic acid makes the separation of lactic acid very difficult job. Esterification of lactic acid with methanol followed by hydrolysis of the separated methyl lactate was employed for the recovery of lactic acid. Reactive dividing wall column was proposed for the simultaneous reaction and separation. The intensified process poses a challenging control problem. Dynamic characteristics of the proposed process were examined and control systems were proposed to get a stable control performance for a disturbance in feed. Control performances of the proposed control systems were compared.

Control of superoritioal fluid extraotion process using fuzzy logio (모호논리를 이용한 초임게유체추출공정의 제어)

  • 유두선;이광순;남성우;김정한
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.246-251
    • /
    • 1990
  • A fuzzy control scheme has been proposed for a supercritical extraction process which has attracted much attention recently as a new separation technology. Based on the manual operation experience, three control pairs between manipulated and output variables are selected first and then seven membership functions are defined for control error and time rate of the error, respectively for each control pair, resulting in forty nine Fuzzy control rules. In addition to these, the membership functions are defined in two steps (coarse and fine) to enhance control performance. Fuzzy inference is performed using MAX-MTN composition rule and defuzzified control output is calculated based on center of gravity method. The prosed Fuzzy control scheme has been assessed through numerical simulation. As a result, the proposed scheme shows good control performance comparable with that by INA(inverse nyquist array) which usually requires complicated design procedure.

  • PDF

Trust and Risk based Access Control and Access Control Constraints

  • Helil, Nurmamat;Kim, Mu-Cheol;Han, Sang-Yong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.11
    • /
    • pp.2254-2271
    • /
    • 2011
  • Access control in dynamic environments needs the ability to provide more access opportunities of information to users, while also ensuring protection information from malicious users. Trust and risk are essential factors and can be combined together in access control decision-making to meet the above requirement. In this paper, we propose the combination of the trust and risk in access control to balance information accessibility and protection. Access control decision is made on the basis of trustworthiness of users and risk value of permissions. We use potential relations between users and relations between permissions in access control. Our approach not only provides more access opportunities for trustworthy users in accessing permissions, but also enforces traditional access control constraints such as Chinese Wall policy and Separation of Duty (SoD) of Role-Based Access Control (RBAC) model in an effective way.

Flow Control of Smart UAV Airfoil Using Synthetic Jet Part 1 : Flow control in Hovering Mode Using Synthetic Jet (Synthetic jet을 이용한 스마트 무인기(SUAV) 유동제어 Part 1 : 정지 비행 모드에서 synthetic jet을 이용한 유동제어)

  • Kim, Min-Hee;Kim, Sang-Hoon;Kim, Woo-Re;Kim, Chong-Am;Kim, Yu-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.12
    • /
    • pp.1173-1183
    • /
    • 2009
  • In order to reduce the download around the Smart UAV(SUAV) at hovering, flow control using synthetic jet has been performed. Many of the complex tilt rotor flow features are captured including the leading and trailing edge separation, and the large region of separated flow beneath the wing. In order to control the leading edge and trailing edge separation, synthetic jet is located at 0.01c, $0.3c_{flap}$, $0.95c_{flap}$. As non-dimensional frequency, the flow pattern is altered and the rate of drag reduction is changed. The results show that synthetic jets shorten the vortex period and decrease the vortex size by changing local flow structure. By using leading edge jet and trailing edge jet, download is efficiently reduced compared to no control case at hovering mode.

Effect of Internal Stress on Cyclic Fatigue Failure in ProTaper Universal (ProTaper Universal에 축적된 내부 응력이 피로 파절에 미치는 영향)

  • Jo, Yun-Sung;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.57-66
    • /
    • 2012
  • The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of ProTaper Universal. ProTaper Universal (Dentsply Maillefer) S1, S2, F1, F2, F3, F4 and F5 (25 mm length) were used in this study. To give the internal stress, the ProTaper Universal were put into the .02 taper Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. The rotation speed was 300 rpm and torque value was 1.0 Ncm. ProTaper Universal were grouped by the induced number of internal stress and randomly distributed among one control group and three experimental groups (n=10). The four groups were Stress 0 (control), Stress 1, Stress 2 and Stress 3. These instruments were rotated until separation. For cyclic fatigue measurement, inclined plane was used and time for separation was recorded. It was statistically analyzed using two-way ANOVA and Duncan post-hoc test at 95% confidential level. In all ProTaper Universal, there was statistically significant decrease on time for separation in Stress 3. In F2 and F3, there were statistically significant difference between control group and all experimental groups. And in F4 and F5, Stress 2 and 3 groups showed significantly lower cyclic fatigue resistance from Stress 0 group. In the limitation of this study, cyclic fatigue failure of ProTaper Universal is influenced by accumulated internal stress.

Robust $H_{\infty}$ Control for Bilinear Systems with Parameter Uncertainties via output Feedback

  • Kim, Young-Joong;Lee, Su-Gu;Chang, Sae-Kwon;Kim, Beom-Soo;Lim, Myo-Taeg
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.386-391
    • /
    • 2003
  • This paper focuses on robust $H_{\infty}$ control for bilinear systems with time-varying parameter uncertainties and exogenous disturbance via output feedback. $H_{\infty}$ control is achieved via separation into a $H_{\infty}$ state feedback control problem and a $H_{\infty}$ state estimation problem. The suitable robust stabilizing output feedback control law can be constructed in term of approximated solution to x-dependent Riccati equation using successive approximation technique. Also, the $H_{\infty}$ filter gain can be constructed in term of solution to algebraic Riccati equation. The output feedback control robustly stabilizes the plant and guarantees a robust $H_{\infty}$ performance for the closed-loop systems in the face of parameter uncertainties and exogenous disturbance.

  • PDF

Drop Time Evaluation for SMART Control Rod Assembly (스마트 제어봉집합체의 낙하시간 평가)

  • Kim, Kyoung-Rean;Jang, Ki-Jong;Park, Jin-Seok;Lee, Won-Jae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • The control rod assemblies do freely fall into the reactor core by the gravity from the control rod drive mechanism. In order to achieve a rapid shutdown and control the reactor power, it is required to insert control rod assemblies as soon as possible. In this paper, we evaluated the drop time and flow characteristics caused around guide tube for SMART(System-integrated modular advanced reactor) control rod assembly. Numerical analyses are carried out with FLUENT program of computational fluid dynamics. This study results show that the drop time of the control rod assembly in the operating condition of SMART is more 20 percent rapidly than the drop time of the room temperature and ambient atmosphere condition.

Morphological Effect of Dispersed Phase on Gas Separation Properties through Heterophase Polymer Membrane: Theoretical and Experimental Approaches.

  • Park, Cheolmin;Jo, Won-Ho;Kang, Yong-Soo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.04a
    • /
    • pp.55-56
    • /
    • 1996
  • Heterophase polymer system has been attractive for a potential applicability to gas separation membrane material. It has been known that there is a trade-off between gas permeability and its selectivity in common polymers. Therefore, the heterophase polymer can be an alternative for a gas separation membrane material because its transport properties can be readily controlled by blending of two different polymers. The transport properties of immiscible polymer blends strongly depend upon the intrinsic transport properties of corresponding polymers. Another important factor to determine the transport properties is their morphology: volume fraction, size and shape of dispersed phase. Although the effect of the volume fraction of the dispersed phase on the transport properties has been widely investigated, the size and shape effects have been paid attention very much. In an immiscible polymer blend of two polymers, its morphology is primarily controlled by its volume fraction of dispersed phase. Therefore, the effect of the size of the dispersed phase can be hardly seen. Therefore, a block copolymer has been commonly employed to control their morphology when each block is miscible with one or the other phase. In this work, gas transport properties will be measured by varying the morphology of the heterophase polymer membrane. The transport properties will be interpreted in terms of their morphology. The effect of the volume fraction of the PI phase and, in particular, its size effect will be investigated experimentally and theoretically.

  • PDF

Preparation of Alumino-silicate Membrane and Its Application to a Gas Separation

  • 김태환
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2002.04a
    • /
    • pp.23-46
    • /
    • 2002
  • The cryogenic, pressure swing adsorption and membrane methods have been used to separate air into nitrogen and oxygen. The air separation membrane is made of the polymers, of which manufacturing process is complicate and it causes a little high production cost. Polymer membrane has temperature limit in usage and low durability even at moderate temperature. Therefore, inorganic membranes have been studied for years. As formation of unit alumino-silicate membrane, unit cells of membrane were made with a few coating methods. In this study the dipping of substrate into sols, application of vacuum to the opposite side of substrate with coating and rotating of the substrate in the sols were found as good coating memthods to make a uniform coating and to control the thickness of membrane. The membrane coats were examined by SEM and XRD. The sample ESZl-1 was compared with those of samples that prepared by another method. The present developed coating methods could be applied to the various types of zeolite membrane formation, that is A- X-, Y- ZSM- and MCM-types of membranes. Also these membrane forming methods could be applied to formation of catalyst absorbed zeolite membrane, of which zeolite absorb the catalytic metals. The product obtained from these coating methods could be applied to the industrial gas and liquid phase catalytic reaction and separation processes.

  • PDF

Trend on the Curtailments of Medical and Drug Expenditure Before and After the Separation between Prescription and Dispensing in General Hospitals (의약분업 전후 일부 종합병원 진료비 및 약제진료비 삭감추이)

  • 조희숙;이선희
    • Health Policy and Management
    • /
    • v.12 no.3
    • /
    • pp.23-35
    • /
    • 2002
  • Fiscal crisis in the medical insurance system has put the pressure upon hospitals by increasing the rate of curtailment, since the implementation of the separation of prescription and dispensing of medicine. The purpose of this study is to analyse the curtailment of mdical and drug expenditure before and after the system of separation between prescribing and dispensing and to suggest the problems about current inspection system. Data were obtained from 13 general hospitals and used for analysis of trends on medical & drug expenditure, and curtailment in 1999-2000 at three months intervals. The results were as follows; The scale of curtailment for drug expenditure has been increased on outpatient and inpatient since 2000. For the curtailed drug cost with outpatient, the ratio of curtailed drug expenditure has been increased in the case of prescription within the hospital. These results suggest that review system in social insurance were over-focused to control the cost and it might to impede the validity of review function in insurance system. Therefore, it' s needed to develope the scientific and reasonable criteria for Inspection and evaluation of durg expenditure.