• Title/Summary/Keyword: Control malfunction

Search Result 238, Processing Time 0.028 seconds

The detection of IC engine's Mutiple misfire using Walsh transform (월쉬변환을 이용한 IC엔진의 다중실화검출)

  • 김종부;이태표어정수임국현
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.235-238
    • /
    • 1998
  • This paper presents the detection of internal combustion engine's multiple misfire. The primary cause of air pollution by vehicles is imperfect conbustion of fuel. The CARB(California Air Resources Board) have imposed regulations for the detection of misfiring in automotive engines. The OBD-II regulations requir that misfire should be monitored by the diagnostic system, and that the goal of OBD-II is to alert the driver to the presence of a malfunction of the emission control system. Present invention based upon measurements of engine roughness as derived from crankshaft angular velocity measurements with special signal processing method. Crankshaft angular velocity signals are processed by walsh-fourier transform. Experimental work confims that it's possible to apply walsh-fourier transform for the detection of multiple misfires in no-load idle and road testing.

  • PDF

Reliability Assessment Criteria of Sensor Module for Lighting Fixtures (조명용센서모듈의 신뢰성평가기준)

  • Jeong, Hee-Suk;Park, Chang-Kyu;Jeong, Hai-Sung;Baik, Jai-Wook
    • Journal of Applied Reliability
    • /
    • v.10 no.1
    • /
    • pp.11-24
    • /
    • 2010
  • Lighting industry is rapidly being developed as the ubiquitous society based on sensor network emerges. This kind of paradigm shift brings the society convergence of technologies which leads to smart lighting system as well as the integration of interior and sensibility control. However, standards for sensors have not been firmly established, and problems related to quality and malfunction have been brought up, thereby calling for careful approach to the enhancement and assessment of reliability of the item. In this article reliability assessment criteria for sensor module for lighting fixtures is established in terms of performance assessment criterion and reliability assessment criterion.

The Insulation Design of Enclosure for Diagnostic Device in Extra High Voltage Line (초고압 선로 진단장치용 외함 절연설계)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • In this paper, in order to avoid equipment malfunction due to electromagnetic waves, which can occur when high-voltage live line diagnostic device fabrication, the enclosure structure of the diagnostic device with power lines that can minimize the EMI (electromagnetic interference) was modeled using the FEM (finite element method). Simulation examined the strength of the electric field in the required thickness, material and regions where there is a control board while changing the curvature radius of the corner making the enclosure, and By applying a mechanical design and simulation results that occur during the actual production has been designed for the final design. Most of the simulation results for the electric field is concentrated in the final model, the inner edge of the enclosure could be confirmed that the stable structure.

A New Valve Actuator for a Glaucoma Treatment by Using MEMS

  • Byunghoon Bae;Kim, Nakhoon;Park, Kyihwan;Hongseok Kee;Kim, Seonho;Lee, Yeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.103.6-103
    • /
    • 2001
  • Glaucoma is an eye disease which is caused by abnormal high IOP (Intra Ocular Pressure) in the eye. High IOP is caused by the aqueous humor which is produced consistently but not drained due to the malfunction of the trabecular system which has a role of draining the aqueous humor into the venous system. Currently, there are some methods to treat glaucoma, Among these, the use of implants is increasing in these days due to many problems in other methods. However, conventional implants are passive implants and have critical disadvantage. Therefore, it is needed to develop a new implant using MEMS structure which is capable of controlling the IOP actively and copes with personal difference of patients. An active glaucoma implant consists of the valve actuator, pressure sensor, controller, and power supply. In this paper the valve actuator is considered. We make experiments and simulations with the fabricated ...

  • PDF

EMI Mesh Development for the PDP using Electroforming (Electroforming을 이용한 PDP용 EMI 메시 개발)

  • Kwon, H.H.;Beom, M.W.;Lim, S.Y.;Hwang, C.S.;Park, D.S.;Lee, T.W.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.108-113
    • /
    • 2011
  • There are a lot of PDP TV for a plasma discharge pulse voltage generated by the use of electromagnetic waves. EMI mesh film is near Infrared ray caused by malfunction of the remote control intended to prevent this phenomenon. In this study, the formation of fine pattern by making the mold is imprinted on the film sheet. EMI mesh film has been granted by filling in the conductive material region imprinted with electroforming in the manufacture of resistance. The fine patterns fabricated with electroforming facility thickness of homogenization process technology were established to optimize the working conditions.

연기농도 계측용 광학식 미세입자 감지장치 개발

  • 김영재;김희식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.128-132
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of smoke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility from the fire. We need to develope a new high precision smoke detection system to keep expensive industial facilities most reliably from fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke psrticles in the air. It is operated continuously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities,such as power plants, underground common tunnel,main control rooms,computer rooms etc.

  • PDF

ACOUSTIC EMISSION IN BENDING FATIGUE PROCESS OF CARBURIZING SPUR DEAR BY AE SOUTCE LICATION

  • Sentoku, Hirofumi;Yamato, Hiroyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.142-145
    • /
    • 1995
  • It is important from prevention of the malfunction and an important accident by the failuer, to detect a failuer in revolution devices. The acoustic emission(AE) method is expected as means that defects an abnormal phenomenon of revolution devices earlily and utilized. Although a research example by the AE method is reported regarding a gears, little reserch has been conducted using the AE method for running gears in a bending fatigue process of spur gear teeth. Therefore, in this report, with two micro AE sensors attached to the side of the gear, AE was measured in a bending fatigue process of a carburizing gear by using the power circurating-type machine and AE source location in gear teeth were required. By various analysis in these data, the AE characteristics in the fatigue damaging process of the gear tooth were determined.

  • PDF

The Plan to Increase Efficiency of Exhaust Gas Recirculation System (배기가스 재순환장치 효율 증대 방안)

  • Kim, Kwang Soo;Chung, Soon Suk;Heo, Yun Bok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.185-194
    • /
    • 2014
  • Internal engine is the main power source of vehicle and is the main source of air pollution. To satisfy this getting rigorous emission regulation, it must be solved simultaneously the dilemma of reducing emission gas and increasing heat efficiency. Diesel engine is preferred compare with gasoline engine in aspect of energy consumption but it must be solved reducing the containing of NOx, CO and HC. In this study: 1. Looking for alternative of performance improvement of Exhaust Gas Recirculation(EGR) which is emission gas reduction system. 2. Reducing malfunction of controlling emission gas. 3. Made possible precision control.

Analysis of Noise Reduction Performance for Noise Cut Transformer (Noise Cut Transformer의 노이즈 억제성능 분석)

  • Lee, Jae-Bok;Huh, Chang-Su;Lee, Ki-Chul;Myung, Sung-Ho;Ha, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1784-1786
    • /
    • 1996
  • It is necessary to eliminate the broad band noise which frequency is in a few kHz to MHz in the AC line to supply the power to electrical and electronic control equipments. Because this kind of noise could damage the device or could be a source of malfunction, many devices like a filter and surge suppressor are developed to cut off the noise. But those device could not disconnected from the power line, so it remain some problem and on be used in limited area, In this paper, we present performance test results NCT(noise Cut Transformer) with excellent performance for reducing the high frequency noise and surge existing in the power line.

  • PDF

The Study of Tilting Control System for Tilting Vehicle (틸팅차량용 틸팅제어시스템 기술개발에 관한연구)

  • Lee, Su-Gil;Han, Seong-Ho;Han, Young-Jae;Lee, Woo-Dong;Song, Yong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.229-231
    • /
    • 2004
  • Tilting trains are now an established feature of railway operations throughout the world. For intercity traffic, tilt provides operators with increasing speeds, and therefore enhanced competitiveness, on existing routes where insufficient traffic or a lack of funds precludes the construction of a dedicated new high-speed railway. Appling the tilting train, we can expect 30% of speed up on existing lines, but the stability of the electric current would be low because of tilting the train. Also, the spark between the catenary and pantagraph cause environmental problems such as noise, radio wave malfunction. Therefore, the tilting on pantagraph for the power suppling device is very essential for stable electric power supply.

  • PDF