• Title/Summary/Keyword: Control factor

Search Result 8,393, Processing Time 0.049 seconds

Dimensions and Assessment of Korean Parenting Style (한국 부모의 자녀 양육방식에서의 차원과 평가)

  • 조복희;이진숙;이흥숙;권희경
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.10
    • /
    • pp.123-133
    • /
    • 1999
  • The purpose of the study was to develop the parenting style scale which is reflecting cultural background of Korean parent's parenting for their children. The instalment was designed based on the literature reviews and on the Baumrind's parenting style. A total of three hundred and sixty two mothers whose children from first and second grade in elementary school completed the Questionnaires. The questionnaires consisted with the items addressing different types of parenting style which include love and care, encouragement of independence, enjoyment in parenting, communication, control, control of aggressiveness, strategies of control , request of maturity. Factor of analysis was applied to examine validity of Korean parenting style scale. Based on the factor analysis, 33 items selected for final questionnaire and two factors discovered. The first factor which named 'warmth'included 20 items such as love and care toward their children, communication, enjoyment in parenting, encouragement toward independency. The second factor which named'control'included 13 items such as control of children's behavior and discipline of children. Warmth factor accounted for 46% of variance and control factor accounted for 18% of variance. Internal consistency was also checked. Although warmth and control factor represented a moderate internal consistency, control factor showed lower correlations then warmth factor. The reliability estimates (Cronbach alpha) were. 87 and 71 for warmth and control factor respectively. Korean parenting style scale can be used to address the appropriateness of Baumrind's theoretical assumptions in parenting style as well as to examine parenting style for Korean population. However, this instalment was developed with Korean mothers only. Further analysis need to be addressed with fathers.

  • PDF

Design of active power factor control AC/DC converter having current control loop with no compensator (전류 제어 루프에 보상을 행하지 않는 능동 역률 제어 AC/DC 컴버터의 제어기 설계)

  • 이인호;김성환;유지윤;박귀태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.216-223
    • /
    • 1996
  • The active power factor control AC/DC converter needs a current loop compensator to obtain better dynamic characteristics and power factor performance, but the optimal design of a current loop compensator is difficult because the AC/DC converter is a nonlinear system having periodically varying poles and zeros. The predictive current control scheme generates a control input using the dynamic equations of the AC/DC converter so that the dynamic of the AC/DC converter is included in the controller and the necessary bandwidth and the gain characteristics of the current control loop are satisfied. And as a result, a compensator becomes unnecessary and the current loop shows the improved current loop characteristics. In this paper, a power factor controller without current loop compensator by adopting a predictive current control scheme is designed and the designed power factor controller is modelled by using a small signal perturbation modelling technique, and simulated to investigate its small signal characteristics. A 200 W power factor control AC/DC converter is built to verify the effectiveness of the proposed power factor controller.

  • PDF

Imposed Weighting Factor Optimization Method for Torque Ripple Reduction of IM Fed by Indirect Matrix Converter with Predictive Control Algorithm

  • Uddin, Muslem;Mekhilef, Saad;Rivera, Marco;Rodriguez, Jose
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.227-242
    • /
    • 2015
  • This paper proposes a weighting factor optimization method in predictive control algorithm for torque ripple reduction in an induction motor fed by an indirect matrix converter (IMC). In this paper, the torque ripple behavior is analyzed to validate the proposed weighting factor optimization method in the predictive control platform and shows the effectiveness of the system. Therefore, an optimization method is adopted here to calculate the optimum weighting factor corresponds to minimum torque ripple and is compared with the results of conventional weighting factor based predictive control algorithm. The predictive control algorithm selects the optimum switching state that minimizes a cost function based on optimized weighting factor to actuate the indirect matrix converter. The conventional and introduced weighting factor optimization method in predictive control algorithm are validated through simulations and experimental validation in DS1104 R&D controller platform and show the potential control, tracking of variables with their respective references and consequently reduces the torque ripple.

Unity Power Factor Control for A Single Phase AC/DC PWM Converter (단상 AC/DC PWM 변환기의 단위 역률 제어)

  • Kang, Dong-Woo;Cha, Young-Kil;Lee, Deuk-Kee;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.373-377
    • /
    • 1996
  • Recently, active power factor control for AC/DC converter has been required to replace for a conventional diode rectifier. A voltage type AC/DC converter is widely used to obtain higher regulated DC voltage than input voltage with a unity power factor and a sinusoidal line current. This paper describes several active power factor control method for AC/DC converter. The analysis of several active power factor control is given. The simulations for hysteresis control, peak current control. constant frequency control and average current mode control are represented and compared.

  • PDF

Fuzzy Control Method By Automatic Scaling Factor Tuning (자동 양자이득 조정에 의한 퍼지 제어방식)

  • 강성호;임중규;엄기환
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2807-2810
    • /
    • 2003
  • In this paper, we propose a fuzzy control method for improving the control performance by automatically tuning the scaling factor. The proposed method is that automatically tune the input scaling factor and the output scaling factor of fuzzy logic system through neural network. Used neural network is ADALINE (ADAptive Linear NEron) neural network with delayed input. ADALINE neural network has simple construct, superior learning capacity and small computation time. In order to verify the effectiveness of the proposed control method, we performed simulation. The results showed that the proposed control method improves considerably on the environment of the disturbance.

  • PDF

Power Factor Control of a Doubly Fed Induction Machine using Fuzzy Logic (퍼지로직을 이용한 이중여자 유도기의 역률제어)

  • Kim Jae-Hong;Kim Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.268-271
    • /
    • 2001
  • This paper describes the power factor control of doubly fed induction machine using fuzzy logic algorithm in wind power generation system. Under fuzzy logic control, which enables superior dynamic performance, the power factor is independently controllable by decoupled d, q rotor experimental results are presented.

  • PDF

The Correlations among Psychological Control in Parents with a child, and Empathy, Humor Sense, Parenting self-efficacy (유아기 부모의 심리적 통제 양육과 공감능력, 유머감각, 양육효능감 간의 관계 연구)

  • Kim, Ji-hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.831-842
    • /
    • 2022
  • The purpose of this study was to examine the correlations among empathy, humor sense parenting self-efficacy and psychological control in Korean parents with a child. For research, 203 parents with a child under the age of 5 attending kindergarten in Seoul participated in this study. As a result of the study, parenting self-efficacy was the lowest and psychological control was the highest. In adittion, among 'empathy', 'humor sense' and 'autonomy support', 'guilt inducement' on sub factor of psychological control showed a significant correlations. In addition, 'cognitive empathy' on sub factor of empathy was significantly correlated with 'autonomy control' on sub factor of psychological control, and 'preference for humor' on sub factor of humor was significantly correlated with 'identical parenting' on sub factor of psychological control. Among parenting self-efficacy and 'autonomy support', 'guilt inducement', 'autonomy control' on sub factor of psychological control showed a significant negative-correlation. 'Difficulty in parental roles' on sub factor of parenting self-efficacy was negatively correlated with other factors except 'identical parenting' on sub factor of psychological control.

Distributed Constrained Power Control with Non stationary Relaxation Factor in CDMA Cellular systems (CDMA 셀룰라 시스템에서 변동 경감 요소를 가지는 제한적 분산 전력제어)

  • Oh, Do-Chang;Lee, Moo-Young;Lee, Dong-Gi;Her, Yong-Do
    • Journal of Information Technology Applications and Management
    • /
    • v.13 no.4
    • /
    • pp.291-302
    • /
    • 2006
  • The current paper proposes fast distributed constrained power control (FDCPC) with a non stationary relaxation factor as the next power update for CDMA cellular power control systems. A review is also given of unconstrained control algorithms: distributed power control (DPC), unconstrained second order power control (USOPC), and DPC with a stationary relaxation factor (DPCSRF) To improve the performance of outage probability convergence, DCPC with a non stationary relaxation factor (FDCPC) is proposed. Under constrained conditions, the convergence rate of FDCPC is shown to outperform that of DCPC and constrained second order power control(CSOPC).

  • PDF

Mapping Control Function for High Power Factor Cycloconverter (고역률 사이크로 컨버터의 매핑함수제어)

  • 김광태
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.237-240
    • /
    • 2000
  • A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current. unity input displacement factor regardless of load power factor. Moreover compensation of the asymmetrical and harmonic containing input voltage is sautomatically realized and calculation time of control function is reduced.

  • PDF

Robust and Unity Input Power Factor Control Scheme for Electric Vehicle Battery Charger (전기차 배터리 충전기용 강인한 단위 입력 역률 제어장치)

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • This study develops a digital control scheme with power factor correction for a front-end converter in an electric vehicle battery charger. The front-end converter acts as the boost-type switching-mode rectifier. The converter assumes the two roles of the battery charger, which include power factor control and robust charging performance. The proposed control scheme consists of a charging control algorithm and a grid current control algorithm. The scheme aims to obtain unity input power factor and robust performance. Based on the linear average model of the converter, a constant-current constant-voltage charging control algorithm that passes through only one proportional-integral controller and a current feed-forward path is proposed. In the current control algorithm, we utilized a second band pass filter, a single-phase phase-locked loop technique, and a duty-ratio feed-forward term to control the grid current to be in phase with the grid voltage and achieve pure sinusoidal waveform. Simulations and experiments were conducted to verify the effectiveness of the proposed control scheme, both simulations and experiments.