• Title/Summary/Keyword: Control device

Search Result 5,522, Processing Time 0.036 seconds

Development and Application of Siphon Breaker Simulation Program (사이펀 차단기 시뮬레이션 프로그램의 개발 및 활용)

  • Lee, Kwon-Yeong;Kim, Wan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.346-353
    • /
    • 2016
  • In the design conditions of some research reactors, the siphon phenomenon can cause continuous efflux of water during pipe rupture. A siphon breaker is a safety device that can prevent water efflux effectively. However, the analysis of the siphon breaking is complicated because many variables must be included in the calculation process. For this reason, a simulation program was developed with a user-friendly GUI to analyze the siphon breaking easily. The program was developed by MFC programming using Visual Studio 2012 in Windows 8. After saving the input parameters from a user, the program proceeds with three steps of calculation using fluid mechanics formulas. Bernoulli's equation is used to calculate the velocity, quantity, water level, undershooting, pressure, loss coefficient, and factors related to the two-phase flow. The Chisholm model is used to predict the results from a real-scale experiment. The simulation results are shown in a graph, through which a user can examine the total breaking situation. It is also possible to save all of the resulting data. The program allows a user to easily confirm the status of the siphon breaking and would be helpful in the design of siphon breakers.

A Design Technique of Configurable Framework for Home Network Systems (홈 네트워크 시스템을 위한 재구성 프레임워크 설계 기법)

  • Kim, Chul-Jin;Cho, Eun-Sook;Song, Chee-Yang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1844-1866
    • /
    • 2011
  • In a home network system, each customer electronic device has the control data format chosen by its manufacturing company and there are various types of digital devices and protocols. Besides the mutual operating environments among the various devices are dissimilar. Affected by the characteristics explained above, home network systems can hardly support the crucial functions, such as data compatibility, concurrency control, and dynamic plug-in. Thus, the home network system shows relatively poor reusability. In this paper, we suggest design technique of configurable framework, which can widely support the variability, to increase the reusability of the home network system. We extract the different parts of the home network system as variation points, and define them as the variability types. We design a structure of configurable framework, and suggest customization technique of configurable framework through selection technique and plug-in technique. Also, we prove the reusability by applying the proposed framework and it methods to real-world home network systems and analyzing the measurement results of these case studies using software metrics. We can expect the proposed approach provides better reusability than the existing them by analyzing those measurement results.

Design of pHEMT channel structure for single-pole-double-throw MMIC switches (SPDT 단일고주파집적회로 스위치용 pHEMT 채널구조 설계)

  • Mun Jae Kyoung;Lim Jong Won;Jang Woo Jin;Ji, Hong Gu;Ahn Ho Kyun;Kim Hae Cheon;Park Chong Ook
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.207-214
    • /
    • 2005
  • This paper presents a channel structure for promising high performance pseudomorphic high electron mobility transistor(pHEMT) switching device for design and fabricating of microwave control circuits, such as switches, phase shifters, attenuators, limiters, for application in personal mobile communication systems. Using the designed epitaxial channel layer structure and ETRI's $0.5\mu$m pHEMT switch process, single pole double throw (SPDT) Tx/Rx monolithic microwave integrated circuit (MMIC) switch was fabricated for 2.4 GHz and 5 GHz band wireless local area network (WLAN) systems. The SPDT switch exhibits a low insertion loss of 0.849 dB, high isolation of 32.638 dB, return loss of 11.006 dB, power transfer capability of 25dBm, and 3rd order intercept point of 42dBm at frequency of 5.8GHz and control voltage of 0/-3V These performances are enough for an application to 5 GHz band WLAN systems.

Effect of 840 nm Light-Emitting Diode(LED) Irradiation on Monosodium Iodoacetate-Induced Osteoarthritis in Rats (흰쥐의 MIA 유발 무릎 뼈관절염에 대한 840 nm LED의 효과)

  • Jekal, Seung-Joo;Kwon, Pil-Seung;Kim, Jin-Kyung;Lee, Jae-Hyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.151-159
    • /
    • 2014
  • PURPOSE: The purpose of this study was to evaluate whether light-emitting diodes (LED) irradiation could be effective in a noninvasive, therapeutic device for the treatment of osteoarthritis(OA). METHODS: Twenty-four male Sprague-Dawley rats were divided into four groups: Vehicle control (saline); monosodium iodoacetate-injection (MIA); LED irradiation after MIA injection (MIA-LED); indomethacin-treatment after MIA injection (MIA-IMT). OA was induced by intra-articular injection of 3 mg MIA through the patellar ligament of the right knee. Vehicle control rats were injected with an equivalent volume of saline. The LED was irradiated for 15 min/day for a week after 7 days of MIA treatment. To compare with the effect of LED irradiation, the indomethacin was administrated 20 mg/kg twice a week orally after 7 days of MIA treatment. Knee joints were removed and fixed overnight in 10% neutral buffered formalin and decalcified by EDTA for 2 week before being embedded in paraffin. The assessment of OA induction were monitored by knee movement and radiographic finding. Histologic analysis were performed following staining with hematoxylin and eosin, safranin O-fast green, or toluidine blue, picrosirius red, and histologic changes were scored according to a modified Mankin system. Apoptotic cell in tissue sections was detected using TUNEL method. RESULTS: Radiographic examination could not show the differences between the MIA-treated and the MIA-LED-treated rats. In the histologic analysis, however, LED irradiation prevented cartilage damage and subchondral bone destruction, and significantly reduced mononuclear inflammatory cell infiltration and pannus formation. LED irradiation also reduced apoptosis of cartilage cells, but it prevented apoptosis of infiltrated inflammatory cells in synovium. In addition, LED irradiation showed an increase of collagen production in the meniscus. CONCLUSION: These results suggest that the 840 nm LED irradiation would be a suitable non-thermal phototherapy for the treatment of OA, as a cartilage protection and anti-inflammatory modality.

Memory-Free Skin-Detection Algorithm and Implementation of Hardware Design for Small-Sized Display Device (소형 DISPLAY 장치를 위한 비 메모리 피부 검출 알고리즘 및 HARDWARE 구현)

  • Im, Jeong-Uk;Song, Jin-Gun;Ha, Joo-Young;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1456-1464
    • /
    • 2007
  • The research of skin-tone detection has been conducting continuously to enlarge the importance in security, surveillance and administration of the information and 'Password Control System' for using face and skin recognition in airports, harbors and general companies. As well as tile rapid diffusion of the application range in image communications and an electron transaction using wide range of communication network, the importance of the accurate detection of skin color has been augmenting recently. In this paper, it will set up the boundaries of skin colors using the information of Cb and Cr in YCbCr color model of human skin color which is from hundreds compiled portrait images for each race, and suggest a efficient yet simple structure about the skin detection which has been followed by whether the comprehension of the boundaries of skin or not with adaptive skin-range set. With the possibility of the 1D Processes which does not use any memory, it is able to be applied to relatively small-sized hardware and system such as mobile apparatuses. To add the selective mode, it is not only available the improvement of tie skin detection, but also showing the correspondent results about previous face recognition technologies using complicated algorithm.

Mechanical Alignment of Hull Mounted Phased Array Radar on the Separated Mast (분리된 마스트에 설치되는 선체고정 위상 배열 레이더의 기계적 정렬)

  • Seo, Hyeong-Pil;Kim, Dae-Han;Kim, Joon-Woo;Lee, Kyung-Jin;Cho, Kyu-Lyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.465-473
    • /
    • 2019
  • This paper is meaningful as the first case where a 4 - sided hull-fixed phased array radar was installed on a mast separated from Korea and the alignment was verified. The mechanical alignment method was studied for accurately mounting two separate masts for naval ships and the 3D scanner for alignment. Hull-fixed phased array radar uses very high frequency, so the short wavelength can cause a phase difference of the device due to the small positional error. Since the array antenna is fixed with the hull, it has higher accuracy control than the rotary radar for 4 array surfaces. The study describes a method of checking the flatness of two radar masts manufactured at a factory, a method of aligning masts in a shipyard, and a method of aligning four array pad mounting surfaces. As a tool for this, a 3D laser scanner and a software-based method for comparing survey results with 3D CAD are used. This paper is meaningful as the first example of installing a four-sided hull-fixed phased array radar on a separate mast from a Korean naval ship and deriving a mechanical alignment method.

The Development of Protocol for Construction of Smart Factory (스마트 팩토리 구축을 위한 프로토콜 개발)

  • Lee, Yong-Min;Lee, Won-Bog;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1096-1099
    • /
    • 2019
  • In this paper, we propose the protocol for construction of smart factory. The proposed protocol for construction of smart factory consists of an OPC UA Server/Client, a technology of TSN realtime communication, a NTP & PTP time synchronization protocol, a FieldBus protocol and conversion module, a technology of saving data for data transmit latency and synchronization protocol. OPC UA server/client is a system integration protocol which makes interface industrial hardware device and supports standardization which allows in all around area and also in not independent from any platform. A technology of TSN realtime communication provides an high sensitive time management and control technology in a way of sharing specific time between devices in the field of high speed network. NTP & PTP time synchronization protocol supports IEEE1588 standardization. A fieldbus protocol and conversion module provide an extendable connectivity by converting industrial protocol to OPC. A technology of saving data for data transmit latency and synchronization protocol provide a resolution function for a loss and latency of data. Results from testing agencies to assess the performance of proposed protocol for construction of smart factory, response time was 0.1367ms, synchronization time was 0.404ms, quantity of concurrent access was 100ea, quantity of interacting protocol was 5ea, data saving and synchronization was 1,000 nodes. It produced the same result as the world's highest level.

Effects of Smart Home on Performance and Satisfaction of Activities of Daily Living of Wheelchair Users (스마트 홈이 휠체어를 사용하는 장애인의 일상생활활동 수행도와 만족도에 미치는 영향)

  • Woo, Ji-Hee;Kim, Jeong-Hyun;Kim, Jongbae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.242-248
    • /
    • 2019
  • This study was conducted to examine the effects of a smart home (electronic control unit, ECU) on the performance and satisfaction of activities of daily living of wheelchair users. A total of 15 wheelchair users (10 patients with spinal cord injury and 5 patients with stroke) were investigated. Smart homes were equipped with ECU technology, which consisted of automation of furniture and products. The products and facilities were integrated and controlled by a smart device or voice. Performance and satisfaction of activities of daily living were measured by the Canadian Occupational Performance Measure (COPM) before and after residence in a smart home. All participants showed a higher COPM (performance score ${\geq}3$, satisfaction score ${\geq}4$) during residence in a smart home compared to residence in the current home. In addition, the COPM scores differed significantly before and after residence in a smart home. These results provide evidence of the applicability of smart homes based on high technology. However, additional studies of more smart home participants should be conducted to improve the quality of the results.

A LiDAR-based Visual Sensor System for Automatic Mooring of a Ship (선박 자동계류를 위한 LiDAR기반 시각센서 시스템 개발)

  • Kim, Jin-Man;Nam, Taek-Kun;Kim, Heon-Hui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1036-1043
    • /
    • 2022
  • This paper discusses about the development of a visual sensor that can be installed in an automatic mooring device to detect the berthing condition of a vessel. Despite controlling the ship's speed and confirming its location to prevent accidents while berthing a vessel, ship collision occurs at the pier every year, causing great economic and environmental damage. Therefore, it is important to develop a visual system that can quickly obtain the information on the speed and location of the vessel to ensure safety of the berthing vessel. In this study, a visual sensor was developed to observe a ship through an image while berthing, and to properly check the ship's status according to the surrounding environment. To obtain the adequacy of the visual sensor to be developed, the sensor characteristics were analyzed in terms of information provided from the existing sensors, that is, detection range, real-timeness, accuracy, and precision. Based on these analysis data, we developed a 3D visual module that can acquire information on objects in real time by conducting conceptual designs of LiDAR (Light Detection And Ranging) type 3D visual system, driving mechanism, and position and force controller for motion tilting system. Finally, performance evaluation of the control system and scan speed test were executed, and the effectiveness of the developed system was confirmed through experiments.

An Experimental Study on the Biomechanical Effectiveness of Bone Cement-Augmented Pedicle Screw Fixation with Various Types of Fenestrations

  • Yoon, Sang Hoon;Lee, Sang Hyung;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.779-789
    • /
    • 2022
  • Objective : To analyze the effects of the number and shape of fenestrations on the mechanical strength of pedicle screws and the effects of bone cement augmentation (BCA) on the pull-out strength (POS) of screws used in conventional BCA. Methods : For the control group, a conventional screw was defined as C1, a screw with cannulated end-holes was defined as C2, a C2 screw with six pinholes was defined as C3, and the control group type was set. Among the experimental screws, T1 was designed using symmetrically placed thru-hole type fenestrations with an elliptical shape, while T2 was designed with half-moon (HM)-shaped asymmetrical fenestrations. T3 and T4 were designed with single HM-shaped fenestrations covering three pitches and five pitches, respectively. T5 and T6 were designed with 0.6-mm and 1-mm wider fenestrations than T3. BCA was performed by injecting 3 mL of commercial bone cement in the screw, and mechanical strength and POS tests were performed according to ASTM F1717 and ASTM F543 standards. Synthetic bone (model #1522-505) made of polyurethane foam was used as a model of osteoporotic bone, and radiographic examinations were performed using computed tomography and fluoroscopy. Results : In the fatigue test, at 75% ultimate load, fractures occurred 7781 and 9189 times; at 50%, they occurred 36122 and 82067 times; and at 25%, no fractures occurred. The mean ultimate load for each screw type was 219.1±52.39 N for T1, 234.74±15.9 N for T2, 220.70±59.23 N for T3, 216.45±32.4 N for T4, 181.55±54.78 N for T5, and 216.47±29.25 N for T6. In comparison with C1, T1, T2, T3, T4, and T6 showed significantly different ultimate load values (p<0.05). However, when the values for C2 and the fenestrated screws were evaluated with an unpaired t test, the ultimate load value of C2 significantly differed only from that of T2 (p=0.025). The ultimate load value of C3 differed significantly from those of T1 and T2 (C3 vs. T1 : p=0.048; C3 vs. T2 : p<0.001). Linear correlation analysis revealed a significant correlation between the fenestration area and the volume of bone cement (Pearson's correlation coefficient r=0.288, p=0.036). The bone cement volume and ultimate load significantly correlated with each other in linear correlation analysis (r=0.403, p=0.003). Conclusion : Fenestration yielded a superior ultimate load in comparison with standard BCA using a conventional screw. In T2 screws with asymmetrical two-way fenestrations showed the maximal increase in ultimate load. The fenestrated screws can be expected to show a stable position for the formation of the cement mass.