• Title/Summary/Keyword: Control cone

Search Result 261, Processing Time 0.031 seconds

Evaluation of condylar positions in patients with temporomandibular disorders: A cone-beam computed tomographic study

  • Imanimoghaddam, Mahrokh;Madani, Azam Sadat;Mahdavi, Pirooze;Bagherpour, Ali;Darijani, Mansoreh;Ebrahimnejad, Hamed
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.127-131
    • /
    • 2016
  • Purpose: This study was performed to compare the condylar position in patients with temporomandibular joint disorders (TMDs) and a normal group by using cone-beam computed tomography (CBCT). Materials and Methods: In the TMD group, 25 patients (5 men and 20 women) were randomly selected among the ones suffering from TMD according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). The control group consisted of 25 patients (8 men and 17 women) with normal temporomandibular joints (TMJs) who were referred to the radiology department in order to undergo CBCT scanning for implant treatment in the posterior maxilla. Linear measurements from the superior, anterior, and posterior joint spaces between the condyle and glenoid fossa were made through defined landmarks in the sagittal view. The inclination of articular eminence was also determined. Results: The mean anterior joint space was 2.3 mm in the normal group and 2.8 mm in the TMD group, respectively. The results showed that there was a significant correlation between the superior and posterior joint spaces in both the normal and TMD groups, but it was only in the TMD group that the correlation coefficient among the dimensions of anterior and superior spaces was significant. There was a significant correlation between the inclination of articular eminence and the size of the superior and posterior spaces in the normal group. Conclusion: The average dimension of the anterior joint space was different between the two groups. CBCT could be considered a useful diagnostic imaging modality for TMD patients.

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

Reduction in post extraction waiting period for dental implant patients using plasma rich in growth factors: an in vivo study using cone-beam computed tomography

  • Arya, Varun;Malhotra, Vijay Laxmy;Rao, JK Dayashankara;Kirti, Shruti;Malhotra, Siddharth;Sharma, Radhey Shyam
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.285-293
    • /
    • 2019
  • Objectives: This study examined the effects of plasma-rich growth factors (PRGF) on accelerating bone regeneration/repair in fresh extraction sockets, and determined the quality and quantity of bone by assessing the bone density using cone-beam computed tomography (CBCT). Materials and Methods: Twenty patients, who had undergone bilateral extractions, were included in this study. In one extraction socket, PRGF was used and covered with an autologous fibrin plug. Nothing was used in the opposite side extraction socket. Thirteen weeks post extraction, the level of bone regeneration was evaluated on both sides with CBCT. Results: At the end of the study, the mean bone density according to the Hounsfield units (HU) in the control group and PRGF group was 500.05 HU (type III bone type) and 647.95 HU (type II bone type), respectively. Conclusion: This study recommends the use of PRGF in post extraction sites to accelerate the rate of bone regeneration and improve the quality of regenerated bone. The technique to process PRGF was simple compared to previously mentioned techniques used for platelet-rich plasma (PRP) preparation. PRP preparation requires a two-cycle centrifugation procedure, leading to a longer processing time.

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Evaluation of the accuracy of mobile cone-beam computed tomography after spinal instrumentation surgery

  • Eom, Ki Seong;Park, Eun Sung;Kim, Dae Won;Park, Jong Tae;Yoon, Kwon-Ha
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.12-18
    • /
    • 2022
  • Purpose: Pedicle screw fixation provides 3-column stabilization, multidimensional control, and a higher rate of interbody fusion. Although computed tomography (CT) is recommended for the postoperative assessment of pedicle screw fixation, its use is limited due to the radiation exposure dose. The purpose of this preliminary retrospective study was to assess the clinical usefulness of low-dose mobile cone-beam CT (CBCT) for the postoperative evaluation of pedicle screw fixation. Methods: The author retrospectively reviewed postoperative mobile CBCT images of 15 patients who underwent posterior pedicle screw fixation for spinal disease from November 2019 to April 2020. Pedicle screw placement was assessed for breaches of the bony structures. The breaches were graded based on the Heary classification. Results: The patients included 11 men and four women, and their mean age was 66±12 years. Of the 122 pedicle screws, 34 (27.9%) were inserted in the thoracic segment (from T7 to T12), 82 (67.2%) in the lumbar segment (from L1 to L5), and six (4.9%) in the first sacral segment. Although there were metal-related artifacts, the image of the screw position (according to Heary classification) after surgery could be assessed using mobile CBCT at all levels (T7-S1). Conclusions: Mobile CBCT was accurate in determining the location and integrity of the pedicle screw and identifying the surrounding bony structures. In the postoperative setting, mobile CBCT can be used as a primary modality for assessing the accuracy of pedicle screw fixation and detecting postoperative complications.

Texture analysis in cone-beam computed tomographic images of medication-related osteonecrosis of the jaw

  • Polyane Mazucatto Queiroz;Karolina Castilho Fardim;Andre Luiz Ferreira Costa;Ricardo Alves Matheus;Sergio Lucio Pereira Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis(AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

Punching Shear Strength of RC Slabs by Simple Truss Model (단순 트러스 모델에 의한 철근콘크리트 교량 바닥판의 펀칭전단강도)

  • Lee, Yongwoo;Hwang, Hoonhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.187-196
    • /
    • 2008
  • The punching shear strength of RC slabs is estimated analytically by the simple truss model. To avoid intrinsic difficulties in punching shear analysis of reinforced concrete slabs, the slabs were divided into three sub-structures as the punching cone and the remaining parts. The strength of the punching cone was evaluated by the stiffness of inclined strut. The stiffness of springs which control lateral displacement of the roller supports consists of the steel reinforcement which passed through the punching cone. Initial angle of struts was determined by curve fitting method of the experimental data with variable reinforcement ratio in order to compensate for uncertainties in the slab's punching shear, the simplification errors and the stiffness of the remaining sub-structures. The validity of computed punching shear strength by simple truss model was shown by comparing with experimental results. The punching shear strength, which was determined by snap-through critical load of shallow truss, can be used effectively to examine punching shear strength of RC slabs.

Diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography images of a non-displaced fracture of ovine mandibular bone

  • Farzane Ostovarrad;Sadra Masali Markiyeh;Zahra Dalili Kajan
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.375-381
    • /
    • 2023
  • Purpose: This study assessed the diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography (CBCT) images of non-displaced ovine mandibular fractures. Materials and Methods: In this ex vivo study, non-displaced fractures were artificially created in 10 ovine mandibles (20 hemi-mandibles) using a hammer. The control group comprised 8 hemi-mandibles. The non-displaced fracture lines were oblique or vertical, <0.5 mm wide, 10-20 mm long, and only in the buccal or lingual cortex. Fracture lines in the ramus and posterior mandible were created to be at the interface or borders of the 2 stitched images. CBCT images were obtained from the specimens with an 80 mm×80 mm field of view before and after fracture induction. OnDemand software (Cybermed, Seoul, Korea) was used for stitching the CBCT images. Four observers evaluated 56 (28 stitched and 28 non-stitched) images to detect fracture lines. The diagnostic performance of stitched and non-stitched images was assessed by calculating the area under the receiver operating characteristic curve (AUC). Sensitivity and specificity values were also calculated (alpha=0.05). Results: The AUC was calculated to be 0.862 and 0.825 for the stitched and non-stitched images, respectively (P=0.747). The sensitivity and specificity were 90% and 75% for the non-stitched images and 85% and 87% for the stitched images, respectively. The inter-observer reliability was shown by a Fleiss kappa coefficient of 0.79, indicating good agreement. Conclusion: No significant difference was found in the diagnostic performance of stitched and non-stitched cross-sectional CBCT images of non-displaced fractures of the ovine mandible.

Joint Space Analysis Using Cone-beam Computed Tomography Imaging in Patients Diagnosed with Temporomandibular Joint Osteoarthritis and Occlusal Changes

  • Hyun-Jeong Park;Yo-Seob Seo;Jong-Won Kim;Sun-Kyoung Yu;Ji-Won Ryu
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.4
    • /
    • pp.152-158
    • /
    • 2023
  • Purpose: This pilot study aimed to evaluate changes in joint space (JS) using cone-beam computed tomography (CBCT) images of patients diagnosed with temporomandibular joint (TMJ) osteoarthritis (OA) and to determine the association between occlusal changes and JS. Methods: CBCT images were used to measure the anterior, superior, and posterior JSs of the sagittal plane. The differences in JS values over time and between groups were compared. The percentage change in the anteroposterior position of the mandibular condyle between groups was also analyzed. Results: Thirty-four subjects (mean age=43.91±20.13), comprising eight males (23.5%) and 26 females (76.5%), were divided into 18 patients with no change in occlusion (NCO) and 16 patients with a change in occlusion (CO) during TMJ OA. The JS measurements of the study subjects showed a decrease in anterior joint space (AJS) values over time. There was no difference in JS measurements between the groups at T1 and T2. AJS values measured at T1 were lower in the CO group than in the NCO group, but the difference was not statistically significant. In both groups, a posterior position of the mandibular condyle was initially observed with high frequency. However, there is a statistically significant difference in CBCT images taken after occlusal changes, with an increased frequency of condyles observed in the anterior or central positions. Conclusions: In conclusion, AJS decreased over time in TMJ OA, and the mandibular condyle became more anteriorly positioned with occlusal changes. Therefore, clinicians should diligently monitor mandibular condyle morphology and JS using CBCT, along with the patient's clinical symptoms, to treat and control TMJ OA effectively.

Potential impact of metal crowns at varying distances from a carious lesion on its detection on cone-beam computed tomography scans with several protocols

  • Matheus Barros-Costa;Eduarda Helena Leandro Nascimento;Iago Filipe Correia-Dantas;Matheus L. Oliveira;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR(P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.