• Title/Summary/Keyword: Control Value

Search Result 10,379, Processing Time 0.038 seconds

Preparation of TiO2-SiO2 Powder by Modified Sol-Gel Method and their Photocatalytic Activities (수식 졸-겔법에 의한 TiO2-SiO2분체합성 및 광촉매활성)

  • Kim, Byung-Kwan;Mizuno, Noritaka;Yasui, Itaru
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1034-1042
    • /
    • 1996
  • Various $TiO_2-SiO_2$ composite powders were prepared by the modified sol-gel method using 1-dodecanol as DCCA (Dryng Control Chemical Additive ). Their characterizations were carried out and their photocatalytic catalysis was examined on the evolution reaction of hydrogen. The weight losses at $500^{\circ}C$ of only $TiO_2$ and $SiO_2$ powders were 33. 0wt% and 42.5wt%, respectively, and those of the $TiO_2/SiO_2$ powders ($TiO_2/SiO_2=25/75$, 50/50 and 75/25) were about $70.0{\pm}3.0wt%$. The released substances from the powders were almost organic matters. The as-prepared powders except only $TiO_2$ powder were amorphous. Transformation of anatase to rutil was hindered by $SiO_2$ component and the crystallinity of anatase was decreased with increasing $SiO_2$ contents. The as-prepared powders were bulky states. By heating at $600^{\circ}C$ for 1 hr $TiO_2-SiO_2$ powders ($TiO_2=100%$, $TiO_2/SiO_2=75/25,\;50/50$) showed agglomerates consisted of particles in submicron, but those of $TiO_2/SiO_2=25/75$ and $SiO_2=100%$ were still bulky states. Specific surface area of the powders heat-treated at $600^{\circ}C$ for 1hr was increased with $SiO_2$ concents and their pore sizes were also depended on $SiO_2$ contents. The photocatalytic activity of $TiO_2/SiO_2=75/25$ heat-treated at $600^{\circ}C$ for 1hr was 0.240mo1/h.g-cat as $H_2$ evolution rate. This value was about 2.0 times that of P-25(Degussa P-25) as a standard photocatalyst.

  • PDF

Meat Quality and Storage Characteristics of Finishing Pigs by Feeding Stevia and Charcoal (스테비아와 숯이 급여된 비육돈의 육질 및 저장특성)

  • Lee, Jae-Joon;Park, Sung-Hyun;Jung, Dong-Soon;Choi, Yang-Il;Choi, Jung-Soek
    • Food Science of Animal Resources
    • /
    • v.31 no.2
    • /
    • pp.296-303
    • /
    • 2011
  • This study was conducted to determine the effects of stevia (Stevia rebaudiana Bertoni) and charcoal supplementation on meat quality traits in finishing pigs. A total of 420 pigs (LYD) were randomly allocated into seven treatments with three replications. The dietary treatments were T1 (control, basal diet), T2 (basal diet+0.3% stevia), T3 (basal diet+0.6% stevia), T4 (basal diet+0.3% charcoal), T5 (basal diet+0.6% charcoal), T6 (basal diet+0.3% stevia+0.3% charcoal), and T7 (basal diet+0.6% stevia+0.6% charcoal). Pigs were slaughtered conventionally on each marketing day and chilled overnigth. At 24 h postmortem, the Longissimus muscle from left side between the 6th and 14th rib was removed for the meat quality traits. The T6 group showed a higher pH, water holding capacity (p<0.05), and lower drip loss (p<0.05) than those in the T1 group. The T6 group showed lower (p<0.05) $L^*$ (lightness) and $b^*$ (yellowness) values and higher $a^*$ (redness) color value than those in the T1 group, resulting in a redder surface meat color. In the subjective evaluation, marbling and color scores improved in the T6 group compared to those in the other treatments. In the panel test, the T6 group tended to have higher tenderness and juiciness scores than those in the T1 group. In the storage characteristics, all treatments showed similar 2-thiobarbituric acid and volatile basic nitrogen values as well as total microbial counts during 7 d of cold storage. As a result, dietary supplementation with 0.3% stevia and 0.3% charcoal showed the highest meat quality traits and storage characteristics in finishing pigs.

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF

Performance Characteristics of Agitated Bed Manure Composting and Ammonia Removal from Composting Using Sawdust Biofiltration System (교반식 축분 퇴비화 및 톱밥 탈취처리 시스템의 퇴비화 암모니아 제거 성능)

  • Hong, J.H.;Park, K.J.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 2007
  • Sawdust biofiltration is an emerging bio-technology for control of ammonia emissions including compost odors from composting of biological wastes. Although sawdust is widely used as a medium for bulking agent in composting system and for microbial attachment in biofiltration systems, the performance of agitated bed composting and sawdust biofiltration are not well established. A pilot-scale composting of hog manure amended with sawdust and sawdust biofiltration systems for practical operation were investigated using aerated and agitated rectangular reactor with compost turner and sawdust biofilter operated under controlled conditions, each with a working capacity of approximately $40m^3\;and\;4.5m^3$ respectively. These were used to investigate the effect of compost temperature, seed germination rate and the C/N ratio of the compost on ammonia emissions, compost maturity and sawdust biofiltration performance. Temperature profiles showed that the material in three runs had been reached to temperature of 55 to $65^{\circ}C$ and above. The ammonia concentration in the exhaust gas of the sawdust biofilter media was below the maximum average value as 45 ppm. Seed germination rate levels of final compost was maintained from 70 to 93% and EC values of the finished compost varied between 2.8 and 4.8 ds/m, providing adequate conditions for plant growth.

  • PDF

Effect of Olive Oil Substitution Ratio on Quality Characteristics of Low-fat Pork Patty (올리브유 대체 비율이 저지방 돈육 패티의 품질 특성에 미치는 영향)

  • Lee, Si-Hyung;Choi, Young-Joon;Lee, Kyoung-Sook;Jung, In-Chul;Lee, Kyung-Soo;Choi, Gang-Won
    • Journal of Life Science
    • /
    • v.30 no.7
    • /
    • pp.606-613
    • /
    • 2020
  • This study investigated the effect of olive oil substitution ratio on physicochemical quality of pork patty. Five treatments were performed as follows: control (T0, 20% pork fat), T1 (pork fat 15% and olive oil gel 5%), T2 (pork fat 10% and olive oil gel 10%), T3 (pork fat 5% and olive oil gel 15%), and T4 (olive oil gel 20%). The moisture increased and fat amount was decreased in proportion to olive oil substitution ratio. The L* and a* values were highest levels in raw and cooked pork patty of T0, and the b* value was highly enhanced in of cooked pork patty of T4. The water holding capacity, moisture and fat retention were significantly increased, and the cooking loss, diameter reduction and shrinkage ratio were decreased by olive oil substitution ratio. The hardness, springiness and chewiness showed the highest level in T4, and the cohesiveness and gumminess were highest in T0. The reduction ratio of cholesterol in T1, T2, T3 and T4 were 13.8%, 21.6%, 34.5% and 49.0%, respectively, indicating that the content was lowest level in T4. The palmitic acid was the most abundant saturated fatty acid, and the oleic acid was the most abundant unsaturated fatty acid. The unsaturated fatty acid of pork patty was increased in proportion to olive oil substitution ratio. Therefore, the olive oil gel substitution of low-fat pork patty results in a positive effect on the physicochemical qualities due to reduced cholesterol and saturated fatty acids.

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Performance of Occupational Health Services by Type of Service : Cost Benefit Analysis (사업장 보건관리 사업의 형태별 수행성과 분석 -비용편익 분석을 중심으로-)

  • Cho, Tong Ran;Kim, Hwa Joong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.4
    • /
    • pp.5-29
    • /
    • 1995
  • Occupational health services in Korea have been operated as dual types : one is operated by occupational health care manager and the other is health care agency without their own personnel. The performance of occupational health service should be different due to the variety of characteristics of health care manager and workplace, qualification of health care manager. This study is to analyze performance of occupational health care services with a particular consideration of job performance shape and efficiency, based on comparing those two types of health care management to show on the basic data for the settlement of more qualitative health care management system at workplace. For this study, total 391 places in Seoul and Inchon city area ; 154 places (39.4%) managed by designated health care manager and 237 places (60.6%) by the agency with their commission are selected as research samples. Tools for data collection are questionnares that have been investigated during the period of 20 September 1993-20 December 1993. Those data are compared with percentiles, mean, standard deviation and B/C ratio using SPSS PC program. Conclusions observed from the tests and each comparison could be summerized as follows : 1. Occupational health care have been accomplished at workplaces with designated people than with agencies people, and coverage rate of the occupational health care services has differences, due to management types. The reason of these results is due to visit only one or two times monthly by the agencies, while their own health care manager obsess, at the workplaces all the times. 2. Most of the expense for environmental control of all health care services expenditures shows that there is almost no fundamental improvement because more expenses are needed for procuring personal protective equipment and measuring work environment instead of environmental improvement. 3. It is investigated how much the cost of occupational health care services needs per worker, and calculated how much the cost needs per service hour per worker. The results from this show that the cost of occupational health services at workplaces with their own managers used less than the cost of health care agencies, eventually the former gives better services with less cost than the latter. 4. Benefit/Cost ratio is also produced by total benefit/total cost. The result from the above way reads 4.57 as a whole, while their own manager having workplaces reads 4.82 and the agencies do l.56. Even if their own manager performing workplaces spent more cost, this system produces more benefit than the agencies management. 5. The B/C ratio for medical organization such as local clinic, health care center and pharmacy shows more than or equal to at the workplaces controlled by the agencies. It is inferred that benefit would be much less than the cost used, with so being inefficient. 6. It is assumed that the efficiency ratio of health education is equal to reduction rate of workers medical organization visit. Estimated reduction rate 5%, 10%, 15%, show that the efficiency ratio of health education have an effect on producing benefits. It is estimated that more benefit can be produced if more qualitative education will be provided for enhancing health care efficiency. 7. Results of this study cannot be generalized because there are large scale of deviation in case of workplaces with less than 300 full time workers, but B/C ratio reads 2.69 as a whole and 3.25 at workplaces with their own health care manager are higher than 1.63 at the workplaces manged by the agencies. Finally, all the benefit concerning health care services could not be quantified, measured and shown on the value of money. This is a reason that a considerable part of benefits are so underestimated. This is also thought that measurement tools should be developed for measuring benefits of health care services with a comprehensive quantification. in the future. It is also expected that efficiency of occupational health care services should be investigated using cost-effectiveness analysis.

  • PDF

Change of FDG Uptake According to Radiation Dose on Squamous Cell Carcinoma of the Head and Neck (두경부종양에서 방사선조사량에 타른 FDG-PET의 변화양상)

  • Lee Sang-wook;Kim Jae-Seung;Im Ki Chun;Ryu Jin Sook;Lee Hee Kwan;Kim Jong Hoon;Ahn Seung Do;Shin Seong Soo;Yoon Sang Min;Song Siyeol;Park Jin-hong;Moon Dae Hyuk;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.98-105
    • /
    • 2004
  • Purpose : To evaluate whether positron omission tomography (PET) with 2-[F-18]fluoro-2-deoxy-D-giucose(FDG) can be used to predict of early response to definitive aim radlotherapy (RT) in squamous cell carcinoma of the head and neck using response rate and locoreglonal control as study endpoints. Materials and Methods : Twenty-two patients with head and neck cancer underwent a FDG-PET study before RT, after a flrst dose of 45 Gy, and after a second dose on more 4han 70 Gy. Standard uptake value (SUV) was calculated for primary tumor (n=22) and neck lymph node (n:10). Attenuation corrected PET scans acquired 60 min after tracer injection were used for evaluation of FDG uptake In tumors. A quantitative FDG uptake index was expressed as Suvlean (corrected for iean body mass). The follow-up time was at least 5 months (range S-1 S months). Results : A total of 22 primary tumors and 10 metastatic lymph nodes were analyzed In FDG-PET. In the first PET study the mean SUVlean the primary tumors and nodes were 5.4 (SD, 2.5) and 4.6 (SD, 2.3), respectively. In the second PET, study peformed after 46 Gy RT the mean SUV in primary tumor and node decreased to 2.9 (SD, 1.9, p<0.001) and 1.7 (SD, 1.3) respectively. in the third PET study peformed at the full dose (more than 70 Gy), RT the mean SUV In the primary tumors and nodes decreased to 2.3 (SD, 1.5, p<0.001) and 1.5 (SD, 1 .1) respectively. Conclusions: FDG uptake In tumors showed a significant decrease after the 45 Gy and more than 70 Gy of RT for squamous cell carcinoma of the head and neck. Reduction of metabolic activity after 46 Gy of radiotherapy Is closely correlated with radiation response.

Physicochemical Characteristics of Yanggaeng with Pear Juice and Dried Pear Powder Added (배즙과 배 건조분말을 첨가한 양갱의 물리화학적 특성)

  • Park, Yeon-Ok;Choi, Jin-Ho;Choi, Jang-Jeon;Yim, Sun-Hee;Lee, Han-Chan;Yoo, Maeng-Ja
    • Food Science and Preservation
    • /
    • v.18 no.5
    • /
    • pp.692-699
    • /
    • 2011
  • This study was conducted to investigate the physicochemical characteristics of yanggaeng prepared with pear juice and dried pear powder. The proximate composition and total polyphenol content, antioxidant activities, Hunter's color values, texture, sensory properties of pear yanggaeng variants [pear juice (PJ), pear juice and hot-air-dried pear powder (PJH), pear juice and freeze-dried pear powder (PJF) yanggaeng] were examined. The moisture content was highest (27.9%) in the control (C) yanggaeng, but the latter's energy and carbohydrate content were lower than in the pear yanggaeng variants. The differences between the pear yanggaeng variants were not significant.The total polyphenol content was highest in the 20.7 mg/100g PJF yanggaeng. The antioxidant activities of PJF yanggaeng were higher than those of the other pear yanggaeng varients. The Hunter color value results showed that the lightness (L) values were highest in C yanggaeng whereas the redness(a) and yellowness(b) values were highest in PJH yanggaeng. The springiness in texture was lowest in C yanggaeng and not significant in the others. The hardness and chewiness were highest in PJH and PJF yanggaeng, but adhesiveness was lowest therein. The results of the sensory test showed that PJF yanggaeng was the highest in flavor, color, taste, hardness, chewiness, and overal quality. Based on these results, it can be concluded that pear juice and freeze-dried pear powder yanggaeng has excellent physicochemical and antioxidant activities.