User Dynamic Access Control for Privacy Protection in Smart Home (스마트 홈에서 프라이버시 보호를 위한 사용자 동적 접근제어)

  • Cho, Do-eun;Kim, Si-jung
    • Journal of Platform Technology
    • /
    • v.6 no.3
    • /
    • pp.17-22
    • /
    • 2018
  • Smart home is a technology for monitoring and controlling all the information about a house by integrating various home applications like cooling, heating, lighting, kitchen and security systems into a network. Although home appliances have become more convenient to use due to the development of smart home technology, they are also more vulnerable to information security hazards. Unauthorized visitors may have access to any of home appliance to arbitrarily control it or acquire information. This causes serious privacy and security problems, which should be solved to further smart home technology. This present paper proposed a dynamic user access control system for privacy protection in smart homes. The proposed system defines the role of a user of smart home services by automatically identifying the status information of the user and dynamically controls the access range for the service. In this way, the privacy of a user can be protected and the inter-smart device service is effectively provided. Consequently, the proposed dynamic user access control for smart home will improve the security service for protecting privacy in smart home devices.

A Study on Introducing Security Certification for Control Systems (제어시스템 보안인증 도입 방안 연구)

  • Choi, Hoyeol;Kim, Daeyeong;Shin, Hyungjune;Hahn, Changhee;Hur, Junbeom
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.3
    • /
    • pp.725-734
    • /
    • 2016
  • SCADA(Supervisory Control and Data Acquisition) system is widely used for remote monitoring and control throughout the domestic industry. Due to a recent breach of security on SCADA systems, such as Stuxnet, the need of correctly established secure certification of a control system is growing. Currently, EDSA-CRT (Embedded Device Security Assurance-Communication Robustness Test), which tests the ability to provide core services properly in a normal/abnormal network protocol, is only focused on the testing of IP-based protocols such as IP, ARP, TCP, etc. Thus, in this paper, we propose test requirements for DNP3 protocol based on EDSA-CRT. Our analysis show that the specific test cases provide plentiful evidences that DNP3 should follow based on its functional requirements. As a result, we propose 33 specific test case for DNP3 protocol.

Design and Implementation of Network Access Control based on IPv6 (IPv6 기반의 네트워크 접근제어 시스템 설계 및 구현)

  • Shin, HaeJoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6310-6316
    • /
    • 2014
  • The increase in the Internet and smart device users requires high-level network security. Network security consists of Web Firewall, Network Firewall, IPS, DDoS system, UTM (Unified Treat Management), VPN, NAC (Network Access Control), Wireless security, Mobile security, and Virtualization. Most network security solutions running on IPv4, and IPv6 network services are not sufficiently ready. Therefore, in this paper, this study designed and implemented important functions of Network Access Control (NAC), which include IPv6 host detection, isolation, blocking and domain assignment for the IPv6 network. In particular, domain assignment function makes 128 bits IPv6 address management easy. This system was implemented on a KISA IPv6 test-bed using well known devices. Finally, the test result showed that all IPv6 based wired and wireless devices were well-controlled (detection, blocking, isolation and domain assignment).

Executable Code Sanitizer to Strengthen Security of uC/OS Operating System for PLC (PLC용 uC/OS 운영체제의 보안성 강화를 위한 실행코드 새니타이저)

  • Choi, Gwang-jun;You, Geun-ha;Cho, Seong-je
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.2
    • /
    • pp.365-375
    • /
    • 2019
  • A PLC (Programmable Logic Controller) is a highly-reliable industrial digital computer which supports real-time embedded control applications for safety-critical control systems. Real-time operating systems such as uC/OS have been used for PLCs and must meet real-time constraints. As PLCs have been widely used for industrial control systems and connected to the Internet, they have been becoming a main target of cyberattacks. In this paper, we propose an execution code sanitizer to enhance the security of PLC systems. The proposed sanitizer analyzes PLC programs developed by an IDE before downloading the program to a target PLC, and mitigates security vulnerabilities of the program. Our sanitizer can detect vulnerable function calls and illegal memory accesses in development of PLC programs using a database of vulnerable functions as well as the other database of code patterns related to pointer misuses. Based on these DBs, it detects and removes abnormal use patterns of pointer variables and existence of vulnerable functions shown in the call graph of the target executable code. We have implemented the proposed technique and verified its effectiveness through experiments.

Digital Asset Analysis Methodology against Cyber Threat to Instrumentation and Control System in Nuclear Power Plants (원자력발전소의 디지털계측제어시스템의 사이버보안을 위한 디지털 자산분석 방법)

  • Koo, In-Soo;Kim, Kwan-Woong;Hong, Seok-Boong;Park, Geun-Ok;Park, Jae-Yoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.839-847
    • /
    • 2011
  • Instrumentation & Control(I&C) System in NPP(Nuclear Power Plant) plays a important role as the brain of human being, it performs protecting, controling and monitoring safety operation of NPP. Recently, the I&C system is digitalized as digital technology such as PLC, DSP, FPGA. The different aspect of digital system which use digital communication to analog system is that it has potential vulnerability to cyber threat in nature. Possibility that digital I&C system is defected by cyber attack is increasing day by day. The result of cyber attack can be adverse effect to safety function in NPP. Therefore, I&C system required cyber security counter-measures that protect themselves from cyber threat efficiently and also cyber security design should be taken into consideration at concept stage in I&C system development process. In this study, we proposed the digital asset analysis method for cyber security assessment of I&C system design in NPP and we performed digital asset analysis of I&C system by using the proposed method.

A Study on Categorization of Accident Pattern for Organization's Information Security Strategy Establish (기업 정보보안 전략 수립을 위한 보안 사고 유형 분류에 관한 연구)

  • Kim, Hee-Ohl;Baek, Dong-Hyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.193-201
    • /
    • 2015
  • Corporation's valuable intelligent asset is being threatened from the skills of threatening subject that has been evolved along with the growth of the information system and the amount of the information asset. Domestically, attempts of various private information attacks, important information extortion, and information damage have been detected, and some of them have abused the vulnerability of security of information system, and have become a severe social problem that generates security incident. When accessing to the security, most of companies used to establish a strategy with a consistent manner and a solution plan. However, this is not a proper way. The order of priorities vary depending on the types of business. Also, the scale of damage varies significantly depending on the types of security incidents. And method of reaction and critical control point vary depending on the types of business and security incidents. In this study, I will define the security incidents by their types and preponderantly examine how one should react to those security incidents. In this study, analyzed many types of security accidents that can occur within a corporation and an organization considering various factors. Through this analysis, thought about factors that has to be considered by corporations and organizations when they intend to access to the information security. This study focuses on the response methodology based on the analysis of the case analysis of the leakage of industrial secret and private secret other than the conceptual response methodology that examines the way to prevent the leakage of the industry security systems and the industry information activities. And based on these factors, want to be of help for corporations to apply a reasonable approach when they establish a strategy to information security.

Quantitative Methodology to Assess Cyber Security Risks of SCADA system in Electric Power Industry (전력 SCADA 시스템의 사이버 보안 위험 평가를 위한 정량적 방법론에 관한 연구)

  • Kang, Dong-Joo;Lee, Jong-Joo;Lee, Young;Lee, Im-Sop;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.3
    • /
    • pp.445-457
    • /
    • 2013
  • This paper is about the study to build a quantitative methodology to assess cyber threats and vulnerabilities on control systems. The SCADA system in power industry is one of the most representative and biggest control systems. The SCADA system was originally a local system but it has been extended to wide area as both ICT and power system technologies evolve. Smart Grid is a concept to integrate energy and IT systems, and therefore the existing cyber threats might be infectious to the power system in the integration process. Power system is operated on a real time basis and this could make the power system more vulnerable to the cyber threats. It is a unique characteristic of power systems different from ICT systems. For example, availability is the most critical factor while confidentiality is the one from the CIA triad of IT security. In this context, it is needed to reflect the different characteristics to assess cyber security risks in power systems. Generally, the risk(R) is defined as the multiplication of threat(T), vulnerability(V), and asset(A). This formula is also used for the quantification of the risk, and a conceptual methodology is proposed for the objective in this study.

Internal Model Control for Unstable Overactuated Systems with Time Delays

  • Mahmoud, Ines;Saidi, Imen
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.1
    • /
    • pp.64-69
    • /
    • 2021
  • In this paper, we have proposed a new internal model control structure (IMC). It is aimed at unstable overactuated multivariable systems whose transfer matrices are singular and unstable. The model inversion problem is essential to understand this structure. Indeed, the precision between the output of the process and the setpoint is linked to the quality of the inversion. This property is preserved in the presence of an additive disturbance at the output. This inversion approach proposed in this article can be applied to multivariable systems with no minimum phase or minimum phase shift with or without delays in their transfer matrices. It is proven by an example of simulation through which we have shown its good performance as a guarantee of stability, precision as well as rapidity of system responses despite the presence of external disturbances and we have tested this control structure in the frequency domain hence the robustness of the IMC.

Implementation of the Intelligent MUX System for Green USN (녹색 유비쿼터스 지능형 다중화장비의 구현)

  • Kang, Jeong-Jin;Chang, Hark-Sin;Lee, Young-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • Recently emphasizing the importance of security such as national major institutions' facilities or major industrial facilities for the maintenance of security/crime prevention due to specialization of the Green Information Technology(G-IT) and Green Ubiquitous Technology(G-UT) industry fields, The Security System Building linked high technology within the government-related organization, enterprise and army the military is urgently required. This paper is about the green USN intelligent an unmanned guard MUX system that receive the signals, from alarm device within surveillance area, with various ways of communication techniques and then transmit to local control center and remote control server trough TCP/IP network. This study enables the mutual senergy effect by realizing a total solution of an unmanned guard system and also significantly contributes to the global/domestic market expansion. That can be applied to the crime prevention/security fields in the Green Ubiquitous Environment Implemented Business(survalance-Home, Gu-City, Gu-Health, etc.), and will contribute to expand companies with international competitiveness that can provide the Green Ubiquitous Vision(Gu-Vision).

Key Establishment and Pairing Management Protocol for Downloadable Conditional Access System Host Devices

  • Koo, Han-Seung;Kwon, O-Hyung;Lee, Soo-In
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.204-213
    • /
    • 2010
  • In this paper, we investigate the possible security threats to downloadable conditional access system (DCAS) host devices. We then propose a DCAS secure micro (SM) and transport processor (TP) security protocol that counters identified security threats using a secure key establishment and pairing management scheme. The proposed protocol not only resists disclosed SM ID and TP ID threats and indirect connection between TA and TP threats, but also meets some desirable security attributes such as known key secrecy, perfect forward secrecy, key compromised impersonation, unknown key-share, and key control.