• 제목/요약/키워드: Control Structure Concept

검색결과 360건 처리시간 0.029초

문화재 화재 대응훈련을 위한 시뮬레이터 개발 (TRAINING PROGRAM BASED ON DIGIEAL CONTENTS FOR PROTECTING CULTURAL ASSETS FROM FIRE)

  • 기재석
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2015년 정기학술대회
    • /
    • pp.321-323
    • /
    • 2015
  • This study will build a prompt response system based on accurate information about the internal structure of cultural heritages, including the roof structure, to improve the ability to contain and respond to the fire of wooden structure for safe preservation of cultural heritages with historical and academic values that are very vulnerable to fire, and develop a training simulation program based on virtual reality by applying the concept of Edutainment for systemized and interesting training of trainees with a response manual.

  • PDF

Pilot Bus의 정보를 이용한 효율적인 지역별 전압제어 (Effective Localized-Voltage Control Scheme using the Information from Pilot Bus)

  • 송성환;윤용태;문승일;이호철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.505-513
    • /
    • 2006
  • One of the major reasons for recent blackout, like August 14, 2003 blackout in the US and Canada has been insufficient voltage/reactive power support. For the stable reactive power management, a new approach for the voltage monitoring and control structure is required in the market environment. This paper proposes the effective localized-voltage control scheme using the information from pilot buses at each zone. In this paper, the steady state voltage monitoring and control (SSVMC) is adopted and illustrated for the voltage control scheme during steady state because it is thought as the systemic algorithm to explain voltage profile phenomenon before and after contingencies. And the concept of electrical distance is applied to simultaneously achieve both clustering the voltage control zone, and selecting the pilot bus as the representative node at each control zone. Applying SSVMC based on the structure with clustering and pilot bus enables system operators to monitor and understand the system condition much more easily, to monitor and control the voltage in real-time more manageably, and to respond quickly to a disturbance. The proposed voltage control scheme has been tested on the IEEE 14-bus system with the numerical analysis to examine the system reliability and structure efficiency.

점탄성감쇠기를 설치한 구조물의 비용효율성 평가 (Cost-Effectiveness Evaluation of the Structure with Viscoelastic Dampers)

  • 고현무;함대기;조상열
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.387-393
    • /
    • 2001
  • Installing vibration control devices in the structure rises as a solution instead of increasing structural strength considering construction cost. Especially, viscoelastic dampers show excellent vibration control performance at low cost and are easy to install in existing structures compared with other control devices. Therefore, cost-effectiveness of structure with viscoelastic dampers needs to be evaluated. Previous cost-effectiveness evaluation method for the seismically isolated structure(Koh et al., 1999;2000)is applied on the building structure with viscoelastic dampers, which combines optimal design and cost-effectiveness evaluation for seismically isolated structures based on minimum life-cycle cost concept. Input ground motion is modeled in the form of spectral density function to take into account acceleration and site coefficients. Damping of the viscoelastic damper is considered by modal strain energy method. Stiffness of shear building and shear area of viscoelastic damper are adopted as design variables for optimization. For the estimation of failure probability, transfer function of the structure with viscoelastic damper for spectral analysis is derived from the equation of motion. Results reveal that cost-effectiveness of the structure with viscoelastic dampers is relatively high in how seismic region and stiff soil condition.

  • PDF

가변구조 벡터제어를 이용한 유도전동기의 위치제어 (Position Control of Induction Motor using Variable Structure Vector Control)

  • 이윤종;김희준;손영대;권완주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1218-1220
    • /
    • 1992
  • This paper presents the three section sliding mode control algorithm based on variable structure current controller design in a synchronous frame and indirect field oriented control method, and applies it to the position control of induction motor. This control scheme solves the problem of robustness loss during the reaching phase that occurs in a conventional VSC strategy, and ensures the stable sliding mode and robustness enhancement throughout an entire response. As the performance of a VSI fed induction motor drives depends on the characteristics of inner loop current controller, it is desired that the current controller have the fast tracking and robust nature. Therefore, we introduced the voltage mapping table based on the concept of voltage space vector for variable structure current control, and implemented fully digital control system using 16-bit microcontroller with on-chip peripherals without additional processing circuits. Simulation and experimental results confirm the validity of this control scheme for robust AC servo drive system of VSI fed induction motor.

  • PDF

블록 역행렬 기법에 의한 다중입출력 양변위 되먹임제어기의 설계 (Design of Multi-Input Multi-Output Positive Position feedback Controller based on Block-Inverse Technique)

  • 곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.508-514
    • /
    • 2005
  • This paper is concerned with the active vibration control of a grid structure equipped with piezoceramic sensors and actuators. The grid structure is a replica of the solar panel commonly mounted on satellites, which contains complex natural mode shapes. The multi input and multi output positive position feedback controller is considered as an active vibration controller for the grid structure. A new concept, the block-inverse technique, is proposed to cope with more modes than the number of actuators and sensors. This study also deals with the stability and the spillover effect associated with the application of the multi-input multi-output positive position feedback controller based on the block inverse technique. It was found that the theories developed in this study are capable of predicting the control system characteristics and its performance. The new multi-input multi-output positive position feedback controller was applied to the test structure using a digital signal processor and its efficacy was verified by experiments..

  • PDF

블록 역행렬 기법에 의한 다중입출력 양변위 되먹임제어기의 설계 (Design of Multi-input Multi-output Positive Position Feedback Controller Based on Block-inverse Technique)

  • 곽문규
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1037-1044
    • /
    • 2005
  • This paper is concerned with the active vibration control of a grid structure equipped with piezoceramic sensors and actuators. The grid structure is a replica of the solar panel commonly mounted on satellites, which contains complex natural mode shapes. The multi-input and multi-output positive position feedback controller is considered as an active vibration controller for the grid structure. A new concept, the block-inverse technique, is proposed to cope with more modes than the number of actuators and sensors. This study also deals with the stability and the spillover effect associated with the application of the multi-input multi-output positive position feedback controller based on the block-inverse technique. It was found that the theories developed in this study are capable of predicting the control system characteristics and its performance. The new multi-input multi-output positive position feedback controller was applied to the test structure using a digital signal processor and its efficacy was verified by experiments.

MW 규모 풍력 터빈의 기계적 하중 특성 해석 및 제어 (Mechanical Loads Analysis and Control of a MW Wind Turbine)

  • 남윤수;최한순
    • 한국정밀공학회지
    • /
    • 제27권9호
    • /
    • pp.26-33
    • /
    • 2010
  • A multi-MW wind turbine is a huge mechanical structure, of which the rotor diameter is more or less than 100 m. Rotor blades experience unsymmetric mechanical loads caused by the interaction of incoming wind with the tower and wind shear effect. These mechanical loads are transferred to the entire structure of the wind turbine and are known as the major reasons for shortening the life span of the wind turbine. Therefore, as the size of wind turbine gets bigger, the mitigation of mechanical loads becomes more important issue in wind turbine control system design. In this paper, a concept of an individual pitch control(IPC), which minimizes the mechanical loads of rotor blades, is introduced, and simulation results using IPC are discussed.

자기부상 모듈의 4자유도 제어 (4 degrees of freedom control for attractive levitation module)

  • 김국헌;김춘경;조창희;김종문;박민국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.271-273
    • /
    • 1993
  • One maglev vehicle is composed of 6 or 8 modules. Each module is composed of 4 staggered magnets attached to an aluminum bogie. In the view point of levitation control except propulsion-by LIM. 5 is the maximum degree of freedom to be controlled. But rolling control of the vhhicle depends on the bogie structure. We describe just anti-roll type bogie structure and 4 degree of freedom control is sufficient for levitation quality improvement. Multivariable pole-placement concept is used for controller design. Control experiment is performed on a specially designed test module as well as actual bogie system.

  • PDF

공장모니터링을 통한 수평구조 공장제어시스템의 개발 (Development of Heterarchical Control System through Automated Plant Monitoring)

  • 이석희;배용환
    • 한국정밀공학회지
    • /
    • 제14권1호
    • /
    • pp.108-118
    • /
    • 1997
  • The heterarchical structure provides a more attractive solution to the conventional hierarchical structure as the density and level of distrubution of computing resources in manufacturing system expands. Tracing the evolution of control structures for automated manufacturing systems, this paper discusses the design principles for heterarchical system to reduce complexity, increase extendability, flexible configurability and suggests a good example of real-time adaptation using the concept of intelligent agent of manufac- turing entities and fault diagmosis system.

  • PDF

능력기반전력구조를 위한 통합능력프레임워크 연구 (A Study on the Integrated Capability Framework for Capability Based Force Structure)

  • 박상건;이태공;임남규;손현식;김한욱
    • 한국국방경영분석학회지
    • /
    • 제36권2호
    • /
    • pp.39-52
    • /
    • 2010
  • 미 국방성은 플랫폼중심전의 상향식소요제기에서 네트워크중심전의 하향식소요제기로 변화하고 능력기반전력구조개발에 힘쓰고 있으며, 한국군도 다변화하는 안보위협과 전시작전권전환을 앞두고 능력기반전력구조로의 전환을 시도하고 있으나 통합능력의 개념과 개발방법이 부족한 상태이다. 따라서 이 연구는 능력기반전력구조 개발을 위해 상 하위 조직 전체의 능력과 현재의 전력운용관점과 미래의 전력개발관점을 동시에 포함하는 통합능력프레임워크를 제시한다.