• 제목/요약/키워드: Control Room Design

검색결과 354건 처리시간 0.024초

ROOM기법을 이용한 전자연동 소프트웨어 설계에 관한 연구 (A Study on the Design of Railway Electornic Interlocking Software Based on Real-Time Object-Oriented Modeling Technique)

  • 김종선;유지윤
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권9호
    • /
    • pp.439-446
    • /
    • 2001
  • This paper considers the design technique of the real-time control algorithm to implement the electronic interlocking system which is the most important station control system in railway signal field. The proposed technique consists of the structure design and the detail design which are based on the ROOM(Real-Time Object-Oriented Modeling). The structure design is designed with a modeling using the heuristic search technique which, at first, catch and make out the specific requested condition, and then, is designed on the requested condition. The detail design can be implemented if it may get the satisfying values through the repetitive modeling after comparing and examining the data obtained from the structure design in order for the more reliable and accurate system to be implemented. The technique proposed in this paper is implemented with C++ language which is easy to be transferred and compatible with the existing interfaces, and also the operating system is designed and simulated on the VRTX which is a real-time operating system. This proposed technique is applied to the typical station model in order to prove the validity as verifying the performance of the modeled station.

  • PDF

냉난방 시스템의 이중선형 시스템에 관한 제어기 설계 (A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System)

  • 이정석;강민수;김명호;이기서
    • 한국철도학회논문집
    • /
    • 제3권4호
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

메르스 감염관리지침에 따른 감염병 임시 격리병동 계획방법에 관한 연구 - 컨테이너를 이용한 음압격리병동을 중심으로 - (A Design Methodology for the Temporary Isolation Room Based on the MERS-Cov Infection Control Guideline - In Case of Temporary Negative Pressure Isolation Room Using Shipping Container -)

  • 이상현;이진우
    • 대한건축학회논문집:계획계
    • /
    • 제33권12호
    • /
    • pp.19-28
    • /
    • 2017
  • The purpose of this study is to propose a design methodology to build temporary isolation rooms when infectious diseases suddenly occur in a certain region, such as the case of MERS-Cov in South Korea in 2015. Although most big hospitals usually have isolation rooms, they are expensive and dangerous to run such facilities on normal and typical days. To deal with these problems in this research, shipping containers are chosen as devices used to build the temporary isolation rooms near the original hospital. To do so, firstly, a prototype for the temporary isolation room was designed with the three part modules. The first part is for the medical team; the second part including the isolation rooms is for patients; the third part is for medical selection rooms to test the specimens. Secondly, the plan was compared with the MERS-Cov infection control guidelines. Finally this prototype is applied into the Yong-in Yon-sei severance hospital and then evaluated through a CFD simulation using STAR-CCM+(ver.9.06) for checking infectious bacterium movement in this prototype. The result showed that the prototype is effectively safe for patients tested as negative, patients waiting to be tested, and the medical team.

병원 감염관리를 위한 중환자부 공간계획에 관한 연구 (A Study on the Space Design for Nosocomial Infection Control in Intensive Care Unit)

  • 이현진;김길채;오영훈
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권4호
    • /
    • pp.87-95
    • /
    • 2016
  • Purpose: Recently an experience in the MERS crisis focused on the importance of infection control in hospitals. According to Korean National healthcare-associated Infection Surveillance System (KONIS) of the KSICP, a great number of 498 people, 841 people, and 1021 people were infected by pneumonia, urinary tract infection, and bacteremia respectively from 94 hospital ICUs during the year of 2014. Therefore, the purpose of this study is to investigate the configuration and design guidelines for the ICU rooms to minimize the nosocominal infections. Methods: Based on the several infection control guidelines and revised Medical Law, consequent analyses which classified the planning and operational behavior in the ICUs of seven hospitals, were performed to reduce the cross-infection. Results: The results of this study are offering a space, configuration and design guidelines for effective infection control in the intensive care units through the unit-bed area, the bed-to-bed distance, the isolation room, etc. Implications: It is expected that this study propose the direction of architectural planning and guideline for the ICU room in order to realize the intension of revised Medical Law.

간호대학생을 위한 전자태아감시 자가학습 교재의 개발 및 적용효과 (Development and Effects of Supplementary Material about Electronic Fetal Monitoring for Nursing Students)

  • 염계정;김일옥
    • 여성건강간호학회지
    • /
    • 제22권1호
    • /
    • pp.21-29
    • /
    • 2016
  • Purpose: This study aimed to develop supplementary material about the electronic fetal monitoring for nursing students, and to test the effects on electronic fetal monitoring related knowledge and confidence on nursing performance in delivery room. Methods: Totally 58 nursing students were recruited either experimental group (n=30) or a control group (n=28). A non-equivalent control group pretest-posttest design was employed to test the effects on fetal monitoring related knowledge and confidence on nursing performance in delivery room. The supplementary material about the electronic fetal monitoring was developed based on Analysis, Design, Development, Implement and Evaluation (ADDIE) model. Fetal monitoring related knowledge and confidence on nursing performance in delivery room were self-reported by the scales that author developed. Data were collected at pre-test and after the 6-week intervention. Results: There was significant difference in confidence on nursing performance in delivery room between two groups after intervention. Conclusion: These findings suggest the importance of the supplementary material about the electronic fetal monitoring for nursing students to improve confidence on nursing performance in delivery room.

Effectiveness of Ventilation Control in a Dry Room with a Heat and Moisture Source

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Ahn, Kang-Ho;Jung, Young-Sick
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.1-9
    • /
    • 2001
  • The temperature and moisture distributions in a dry room with a heat and moisture source -i.e., workers- are studied numerically by using a standard $k-\varepsilon$ turbulence model. In order to evaluate the effectiveness of heat and moisture ventilation inside the room, the heat removal capacity and the moisture exhaust efficiency are introduced. The effectiveness of ventilation control is analyzed by evaluating the temperature and humidity distributions in the room quantitatively. It is found that the mean absolute humidity inside the room is almost constant regardless of the models and the heat generation rates in this study range. This results from the fact that the moisture generation by the workers was relatively small. Through the modification of the design, 40% improvement in critical decay time was achieved.

  • PDF

항공기 구조용 소방차 탱크룸의 구조 안정성 평가 및 설계 개선에 대한 해석적 연구 (An Analytical Study on Structural Stability Evaluation and Design Improvement of Fire Truck Water Tank for Aircraft Rescue)

  • 권혁진;강명철;임수일;김한욱;홍정기;이호;황영선
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권1호
    • /
    • pp.1-7
    • /
    • 2023
  • In this study, the structural stability of the tank room of an aircraft rescue fire engine is to be studied. The tank room of the aircraft rescue fire engine is filled with fire extinguishing water and chemicals. Fire extinguishing water and chemical are filled to a capacity of about 12.5 tons and are subjected to high stress. The tank room is made of PP material with low yield stress. Structural analysis of the tank room is performed and structural weakness is analyzed. In addition, if a structural problem occurs as a result of structural analysis, an analysis simulation result is presented to derive an improved design and to show the validity of the structural stability of the tank room.

응급의료센터 감염예방을 위한 동선분리를 고려한 평면계획 연구 (Infection Control through Emergency Room Layout)

  • 김중기;서현보
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: Emergency room(ER) is the first place to enter a hospital where patients who might have been infected with contagious disease. Therefore, ER should be designed with infection control in mind. Researchers examined hospital ER layouts to identify layout design that support infection control. Methods: This study analyzed the hospital ER layout of Korean and other hospitals abroad. Researchers focused on route of incoming patients who potentially have infectious disease. Crossing of this route with other routes such as for imaging and testing should be avoided for infection control. Results: There were certain hospital ERs with better control of infection related incidents. ER floor plan layout is analyzed about allocation of key functions with movement routes for each role such as patients and medical staff in mind. To identify layout strategies for ER functions researchers simplified the routes in ER into diagrams. Layout options show that bypassing infection suspected routes over other routes is possible. Implications: Hospitals can control infection easier when they adopt strategic ER layout identified in this study.

홀 센서 기반 전자식 엔진냉각제어 시스템 설계 (Design of Hall Sensor based Electronic Engine Cooling System)

  • 고영호;김현희;이경창
    • 한국산업융합학회 논문집
    • /
    • 제20권4호
    • /
    • pp.325-332
    • /
    • 2017
  • The engine cooling system is a device that maintains the temperature in the engine room at an appropriate level by driving a cooling fan when the temperature in the engine room generated during the vehicle operation occurs over a certain temperature. In recent years, the vehicle cooling system has changed to an electronic system. Therefore, in this paper, we design and develop a hall sensor based electronic engine cooling system. In this paper, a hall sensor module and an actuator module for engine cooling control system are designed. In order to verify the performance of the designed module, the magnetic field control was verified through the simulation of the diameter and the head of the coil.

Digital Human Simulation을 활용한 방사성 폐기물 처리장 주제어실의 인체공학적 평가 (Ergonomic Evaluation of a Control Room Design of Radioactive Waste Facility using Digital Human Simulation)

  • 이백희;장윤;정기효;정일호;유희천
    • 대한인간공학회지
    • /
    • 제29권3호
    • /
    • pp.383-391
    • /
    • 2010
  • The present study evaluated a preliminary control room (CR) design of radioactive waste facility using the $JACK^{(R)}$ human simulation system. Four digital humanoids ($5^{th}$, $50^{th}$, $95^{th}$, and $99^{th}$ percentiles) were used in the ergonomic evaluation. The first three were selected to represent 90% of the target population (Korean males aged 20 to 50 years) and the last to reflect the secular trend of stature for next 20 years in South Korea. The preliminary CR design was assessed by checking its compliance to ergonomic guidelines specified in NUREG-0700 and conducting an in-depth ergonomic analysis with a digital prototype of the CR design and the digital humanoids in terms of postural comfort, reachability, visibility, and clearance. For identified design problems, proper design changes and their validities were examined using JACK. A revised CR design suggested in the present study would contribute to effective and safe operations of the CR as well as operators' health in the workplace.