• 제목/요약/키워드: Control Room Design

검색결과 354건 처리시간 0.024초

원자력발전소에서의 인간공학적 실험평가를 위한 종합 실험설비 개발 (Development of integrated test facility for human factors experiments in nuclear power plant)

  • 오인석;이현철;천세우;박근옥;심봉식
    • 대한인간공학회지
    • /
    • 제16권1호
    • /
    • pp.107-117
    • /
    • 1997
  • It is necessary to evaluate HMI inaspects of human factors in the design stage of MMIS(man machine interface system) and feedback the result of evaluation because operators performance is mainly influenced by the HMI. Therefore, the MMIS design should be reflected the operators psychological, behavioral and physiological characteristics in the interaction with human machine interface(HMI) in order to improve the safety and availability of the MMIS of a nuclear power plant(NPP) by reduction of human error. The development of human factors experimental evaluation techniques and integrated test facility(ITF) for the human factors evaluation become an important research field to resolve hi,am factors issues on the design of an advanced control room(ACR). We developed am ITF, which is aimed to experiment with the design of the ACR and the human machine interaction as it relates to the control of NPP. This paper presents the development of an ITF that consists of three rooms such as main test room(MTR), supporting test room(STR) and experiment control room(ECR). And, the ITF has a various facilities such as a human machine simulator(HMS), experimental measurement systems and data analysis and experiment evaluation supporting system(DAEXESS). The HMS consists of full-scope simulation model of Korean standard NPP and advanced HMI based on visual display nits (VDUS) such as touch color CRT, large scale display panel(LSDP), flat panel display unit and so on.

  • PDF

HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구 (A study on the food clean room system observing the regulations of HACCP)

  • 원영재;서기원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.520-526
    • /
    • 2009
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF

공리적 설계를 이용한 매립형 공기조화시스템의 분석 (Analysis of a Mount Type HVAC Control System Using Axiomatic Design)

  • 이세정;홍을표;김대환;김수옥;박경진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1028-1033
    • /
    • 2008
  • The mount type HVAC control system is a type of an HVAC control system which is installed between a ceiling and ceiling boards of a room to control room temperature. Although the device is quite popular, design is conducted by a conventional way where engineering intuition and experiences are utilized. It is found that the design process is fairly inefficient and time-consuming because there are a lot of feedbacks. The axiomatic approach is used to investigate the design characteristics of the mount type HAVC control system and the Independence Axiom is utilized for the investigation. The Overall hierarchy is established up to the level of parts. It is found that the current design has many coupled and redundant aspects. The hierarchy is reorganized based on the Independence Axiom and a new design process is found. To exploit the new design process in practice, a design manual is made.

  • PDF

전자식 절차서 시스템의 원전제어적합성 확인 및 검증절차 (Validation and Verification Process for the Computerized Procedure System in Nuclear Power Plant Control Room)

  • 차우창
    • 시스템엔지니어링학술지
    • /
    • 제5권1호
    • /
    • pp.33-41
    • /
    • 2009
  • The analog or partly digital typed interface of main control room in nuclear power plant (NPP) is gradually being replaced to the totally digitalized interface suitable for the digital environment. SKN 3,4 Nuclear Power Plant is currently developed in such a way to employ advanced displays and controls such as computerized procedure system(CPS), large display panel(LDP), and Soft control. According to the developed design process, the main control room (MCR) of the SKN3,4 was aesthetically designed based on a design concept of the health and sustainability and technically evaluated with human factors guidelines, which somehow lack of the confidence on the evaluation for the rapidly changing digital environment. The suitable review guideline for the digitalized interface and the environment was developed such as the guideline for CPS with information displays on VDU. For the guideline development, tremendous guidelines and technical papers related to evaluation issues of digital environment has been collected, analyzed and transformed to electric database forms and then built on database management system, called Design Review Supporting System to retrieve the appropriate issues for the practical usage of evaluators-in-field.

  • PDF

HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구

  • 원영재
    • 공기청정기술
    • /
    • 제23권3호
    • /
    • pp.1-9
    • /
    • 2010
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF

가청화를 이용한 중학교 음악실의 음향성능 평가에 관한 연구 (A Study on the Evaluation of Acoustic Performance for Music Room in Middle School Using Auralization)

  • 설수환;강규선;김재수
    • 한국주거학회논문집
    • /
    • 제19권4호
    • /
    • pp.49-57
    • /
    • 2008
  • The case study for this research is a middle school music room located in Iksan City, Korea. Although the room is used for teaching music, indiscreet sound-absorbing materials were applied within the space. Accordingly, a number of difficulties have been experienced when using the room. During a music lesson, the sound-volume is inadequate for music appreciation, while the music performance has an arid sound due to an insufficient echo. In order to control the obstructive factors resulting from a short Reverberation Time, the acoustic factor is optimized in this study by using an Acoustic Simulation, following an arrangement of Acoustic Design. A Psycho-acoustics Experiment was conducted using the Auralizational Technique, whereby the Virtual Acoustic Field can be experienced at the design stage.

납-고무 베어링(LRB) 면진시스템을 적용한 원전주제어실의 진동대 실험 (Experimental Study on Floor Isolation of Main Control Room of Nuclear Power Plant using LRB (Lead Rubber Bearing))

  • 이경진;함경원;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.429-436
    • /
    • 2005
  • In this study, we made two types of main control room floor systems (Type I, Type II) and several shaking table tests with and without isolation system were conducted to evaluate floor isolation effectiveness of LRB(Lead Rubber Bearing). Both type showed large difference according to input earthquake signals, but showed little difference according to floor type. It is required to make LRB of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such LRB, it is recommended that consideration should be taken into account when applied to main control room of NPP.

  • PDF

원전 주제어실 삼차원 면진시스템 수직방향 저감효과 시험연구 (Experimental Study on Vertical Reduction Effectiveness of Main Control Room of NPP using 3-Dimensional Isolation System)

  • 함경원;이경진;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.417-423
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional isolation systems have been studied using a shaking table system. In this study, we made nuclear power plant main control room floor systems and several seismic shaking table tests with and without isolation systems were conducted to evaluate floor isolation effectiveness. Isolation systems have showed large reduction effectiveness in acceleration and response spectra with x and z direction respectively, but horizontal isolation is more effective than vertical one It is required to make isolation systems of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such isolation systems, it is recommended that much consideration should be taken into account when applied to main control room of NPP.

  • PDF

A Case Study on Designing a Console Design Review System Considering Operators' Viewing Range and Anthropometric Data

  • Cha, Woo Chang;Choi, Eun Gyeong
    • 대한인간공학회지
    • /
    • 제36권5호
    • /
    • pp.373-383
    • /
    • 2017
  • Objective: The aim of this study is to introduce an operator console design review system suitable for designing and evaluating consoles based on human factor guidelines for a digitalized main control room in an advanced nuclear power plant which has a requirement for anthropometric data usage. Background: The system interface of the main control room in a nuclear power plant has been getting digitalized and consists of various consoles with many information displays. Console operators often face human-computer interactive problems due to inappropriate console design stemming from the perceptual constraints of anthropometric data usage. Method: Computational models with a process of visual perception and variables of anthropometric data are used for designing and evaluating operator consoles suitable for human system interface guidelines, which are used in an advanced nuclear power plant. Results: From the computational model and simulation application, console dimensions and a designing test module, which would be used for designing suitable consoles with safety concerns in a nuclear power plant, have been introduced. Conclusion: This case study may influence employing a suitable design concept with various anthropometric data in many areas with safety concerns and may show a feasible solution to designing and evaluating the safety console dimensions. Application: The results of this study may be used for designing a control room with the human factors requiring a safe working environment.

신형원전(APR+)을 위한 범용소프트제어기의 내고장성 설계 (Fault Tolerant Design of Universal Soft Controller for Advanced Power Reactor)

  • 예송해;유준
    • 전자공학회논문지
    • /
    • 제49권9호
    • /
    • pp.279-286
    • /
    • 2012
  • 최근 범용소프트제어기 설계는 원자력발전소의 첨단주제어실에 적용되고 있다. 범용소프트제어기는 고집적 주제어실에서 비안전 기기뿐만이 아니라 안전기기를 제어할 수 있는 소프트웨어 기반의 수동제어 수단이다. 따라서 범용소프트제어기는 신형 주제어실의 단일 워크스테이션 구현을 위한 필수적인 설계특성을 갖고 있다. 전통적인 주제어실은 컴퓨터 기반으로 하는 통합 운전원 인터페이스 체계로 대체되고 있다. 범용소프트제어기의 오작동신호 발생 가능성을 줄이기 위해 어떠한 기기의 조작을 위해서는 2단계의 구분된 운전원 조작을 요구하는 설계를 고려하였다. 범용소프트제어기 오작동 가능성은 매우 낮기 때문에 범용소프트제어기 그자체로 발전소의 트립 가능성을 증가시키지는 않는다. 범용소프트제어기는 원자력발전소의 계측제어분야/인간연계 분야의 혁신을 대표한다. 범용소프트제어기는 인간연계를 기반으로 하는 단일 표시장치에 다양한 디비젼의 제어와 표시기를 통합하고 있다. 범용소프트제어기의 고장으로부터 안전기능 수행의 영향을 막기 위해 안전기기 및 기능에는 공학적 안전설비 신호가 적용된다. 또한 안전등급 수동스위치는 범용소프트제어기의 신호보다 우선한다. 그러므로 범용소프트제어기의 오작동 신호는 안전관련 스위치로부터의 제어신호에 의해 차단되어질 수 있다.