• 제목/요약/키워드: Control Requirements

검색결과 2,389건 처리시간 0.027초

Today's Nuclear Challenge: Maintenance and Radiation Exposure

  • Willis, Chales A.
    • Nuclear Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.159-165
    • /
    • 1975
  • The Nuclear power industry today faces a serious and rapidly emerging problem in reactor maintenance and occupational radiation exposure control. The basic problem is the need for much maintenance on nuclear power plants. The problem is seriously compounded by radiation exposure control requirements. Many studies are underway seeking solutions tut the industry is developing rapidly and new plants will not await the results of such studies. It is essential that attention be given to maintenance and exposure control in all phases of plant design, construction and operation.

  • PDF

다중 제어면 고장에 대한 제어면 재분배 고장 대처 기법 (Fault-Tolerant Networked Control Systems Using Control Allocation for Failures in Multiple Control Surfaces)

  • 양인석;김동길;이동익
    • 제어로봇시스템학회논문지
    • /
    • 제17권11호
    • /
    • pp.1067-1073
    • /
    • 2011
  • In this paper, the methodology of a CA (Control Allocation) based FTNCS (Fault-Tolerant Networked Control System) is proposed. Control allocation is a control surface management technique by redistributing the redundant control surfaces in overactuated systems. In modern high performance aircrafts, they adopt many redundant control surfaces to provide high performance and to satisfy various tactical requirements. Moreover, redundant control surfaces provide an opportunity to compensate performance degradation due to failures in more than one actuator by re-allocating redundant control surfaces. Simulation results with an F-18 HARV demonstrate that the proposed CA based FTNCS can achieve a fast and accurate tracking performance even in the presence of actuator faults.

The Analysis of MOUs and their Activities Related to Port State Control

  • Min, Byung-Sun;Kim, Soon-Kap;Kong, Gil-Young;Kim, Chol-Seong;Lee, Yoon-Sok;Kim, Jung-Man;Lee, Chung-Ro
    • 한국항해항만학회지
    • /
    • 제27권3호
    • /
    • pp.321-327
    • /
    • 2003
  • The Memorandum of Understanding (MOU) is the document of intent signed between the Port States Control(PSC) to undertake a uniform as agreed. Though the MOU is not a legally binding, in case where the agreed items are violated without a just cause, the denunciation will follow. International Maritime Organization (IMO) and regional MOUs have been making amendments and reinforcing the relevant requirements, so that port State Authorities can effectively eradicate the substandard vessels. However, the various problems have arisen due to the existence of different requirements of each MOU, the lack of information exchange between each MOU, the lack of uniform PSC implementation within the same MOU and the lack of adequate system due to the short history of MOUs. In this paper, the MOU records for three years (1999∼2001) were analyzed according to each MOU, type of ship, deficiency code, classification society, the number of inspected ships and the number of detained ships to assess the problems (Statistics during 2002 will be published after August 2003). The purpose of this study is to help better understand the PSC activities within each MOU and to establish effective countermeasures by grasping the problems that exist in the PSC at present.

미디어 스트리밍 서비스 기반 엘리베이터 제어 및 정보 시스템 설계 및 구현 (Design and Implementation of Elevator Control and Information System based on Media Streaming Service)

  • 김운용;박석규
    • 한국항행학회논문지
    • /
    • 제14권3호
    • /
    • pp.409-414
    • /
    • 2010
  • 최근 IT융합 환경의 성장과 더불어 엘리베이터 시장 역시 지능화를 통한 다양한 서비스 요구가 증대되고 있다. 이에 본 논문에서는 엘리베이터 시스템의 정보 전달 기능을 높이기 위해 기존 엘리베이터 제어 시스템을 확장한 스트리밍 기반의 정보 시스템을 제시하고자 한다. 정보 전달 구조는 인터넷 기반의 서비스 환경을 기반으로 구성되며 이를 바탕으로 다양한 서비스를 엘리베이터 시스템과 통합하여 운영할 수 있다. 또한 IT 융합 구조를 통해 홈 네트워크 및 다양한 전자 기기와의 결함을 통해 엘리베이터 시스템에서발생 가능한 다양한 사용자의 요구를 쉽게 반영함으로써 스마트 엘리베이터 환경을 구축할 수 있을 것이다.

Eliminating the Third Harmonic Effect for Six Phase Permanent Magnet Synchronous Generators in One Phase Open Mode

  • Liu, Jian;Yang, Gui-Jie;Li, Yong;Gao, Hong-Wei;Su, Jian-Yong
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.92-104
    • /
    • 2014
  • To insure stable operation and eliminate twice torque ripple, a topology for a six phase permanent magnet synchronous generator (SP-PMSG) with a neutral point connected together was analyzed in this paper. By adopting an extended transformation matrix, the mathematic model of the space vector control was established. The voltage and torque equations were deduced while considering the third harmonic flux and inductance. In addition, the suppression third harmonic method and the closed loop control strategy were proposed. A comparison analysis indicates that the cooper loss minimum method and the current magnitude minimum method can meet different application requirements. The voltage compensation amount for each of the methods was deduced which also takes into account the third harmonic effect. A simulation and experimental result comparison validates the consistency through theoretical derivation. It can be seen that all of the two control strategies can meet the requirements of post-fault.

트랜잭션 처리 시스템을 위한 동시성 제어의 기능시험 기법 (Functional Testing Techniques for Concurrency Control in Transaction Processing Systems)

  • 홍석희
    • 한국정보통신학회논문지
    • /
    • 제7권4호
    • /
    • pp.805-811
    • /
    • 2003
  • 정해진 시간 내에 사용자 요구 조건을 충족시키도록 복잡한 소프트웨어를 개발하는 경우 시스템 시험은 중요한 요인이다. 데이터베이스 관리 시스템의 모듈 중 트랜잭션 처리 시스템은 다중 사용자 환경에서 트랜잭션의 수행과 데이터 일관성을 유지하는 중요한 기능을 한다. 본 논문은 트랜잭션 처리 시스템의 동시성 제어 기능이 요구조건을 만족하는지를 체계적이고 자동적으로 시험하기 위한 기법을 제안한다. 다섯 가지 잠금 모드를 지원하는 2단계 잠금 기법을 적용하는 동시성 제어 모듈의 기능을 자동적으로 시나리오 기반의 기능시험을 하고 시험 결과를 사용자에게 제시한다. 또한, 본 논문에서 제안한 기능시험 기법을 실제 데이터베이스 관리 시스템의 모듈 시험 과정에 적용하여 그 타당성을 확인한다.

Tire Industry and Its Manufacturing Configuration

  • Lee, Young-Sik;Cpim;Lee, Jin-Kyu
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.135-138
    • /
    • 2000
  • This paper is intended to propose what manufacturing configuration (manufacturing planning and shop floor control) is suitable for the tire industry. Basically tire-manufacturing process is mixed-products, parallel-disconnected-flow-shop. Both throughput time and cycle tine are very short, the variety of tires is very high, the setup time is long, shop floor data reporting requirements is high, and there are many equipments and people working. And with no exception, tire industry also now confronts increasing requirements of delivery conformance with the above peculiar characteristics of tire manufacturing and changing market environments, this paper suggests, weekly master scheduling with no MRP is desirable and traditional kanban is right selection for shop floor control/scheduling. This paper describes why this configuration should be, using the manufacturing engineering principles and some new insights like four primitives of parallel flow shop. Generally known that shop with high parallel-product-mix and long setup time isn't good candidate for kanban. The four primitives of parallel flow shop explain why kanban is also useful scheduling technique in that environment.

  • PDF

Resilient Reduced-State Resource Reservation

  • Csaszar Andras;Takacs Attila;Szabo Robert;Henk Tamas
    • Journal of Communications and Networks
    • /
    • 제7권4호
    • /
    • pp.509-524
    • /
    • 2005
  • Due to the strict requirements of emerging applications, per-flow admission control is gaining increasing importance. One way to implement per-flow admission control is using an on­path resource reservation protocol, where the admission decision is made hop-by-hop after a new flow request arrives at the network boundary. The next-steps in signaling (NSIS) working group of the Internet engineering task force (IETF) is standardising such an on-path signaling protocol. One of the reservation methods considered by NSIS is reduced-state mode, which, suiting the differentiated service (DiffServ) concept, only allows per-class states in interior nodes of a domain. Although there are clear benefits of not dealing with per-flow states in interior nodes-like scalability and low complexity-, without per-flow states the handling of re-routed flows, e.g., after a failure, is a demanding and highly non-trivial task. To be applied in carrier-grade networks, the protocol needs to be resilient in this situation. In this article, we will explain the consequences of a route failover to resource reservation protocols: Severe congestion and incorrect admission decisions due to outdated reservation states. We will set requirements that handling solutions need to fulfill, and we propose extensions to reduced-state protocols accordingly. We show with a set of simulated scenarios that with the given solutions reduced-state protocols can handle re-routed flows practically as fast and robust as stateful protocols.

근궤적과 수동 조정에 의한 직접 구동형 서보밸브의 PID 제어기 및 미분피드백 이득 설계 (PID Controller and Derivative-feedback Gain Design of the Direct-drive Servo Valve Using the Root Locus and Manual Tuning)

  • 이성래
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권3호
    • /
    • pp.15-23
    • /
    • 2016
  • The direct-drive servo valve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the dc motor. Since the DDV structure is simple, it is less expensive, more reliable, and offers a reduced internal leakage and a reduced sensitivity to fluid contamination. The control system of the DDV is highly nonlinear due to a current limiter, a voltage limiter, and the flow-force effect on the spool motion. The shape of the step response of the DDV-control system varies considerably according to the magnitudes of the step input and the load pressure. The system-design requirements mean that the overshoots should be less than 20%, and the errors at 0.02s should be less than 2%, regardless of the reference-step input sizes of 1V and 5V and the load-pressure magnitudes of 0MPa and 20.7MPa. To satisfy the system-design requirements, the PID-controller parameters of $K_c$, $T_i$ and $T_d$, and the derivative-feedback gain of $K_{der}$ are designed using the root locus and manual tuning.

Call Admission Control Based on Adaptive Bandwidth Allocation for Wireless Networks

  • Chowdhury, Mostafa Zaman;Jang, Yeong Min;Haas, Zygmunt J.
    • Journal of Communications and Networks
    • /
    • 제15권1호
    • /
    • pp.15-24
    • /
    • 2013
  • Provisioning of quality of service (QoS) is a key issue in any multi-media system. However, in wireless systems, supporting QoS requirements of different traffic types is a more challenging problem due to the need to simultaneously minimize two performance metrics - the probability of dropping a handover call and the probability of blocking a new call. Since QoS requirements are not as stringent for non-real-time traffic, as opposed to real-time traffic, more calls can be accommodated by releasing some bandwidth from the already admitted non-real-time traffic calls. If the released bandwidth that is used to handle handover calls is larger than the released bandwidth that is used for new calls, then the resulting probability of dropping a handover call is smaller than the probability of blocking a new call. In this paper, we propose an efficient call admission control algorithm that relies on adaptive multi-level bandwidth-allocation scheme for non-realtime calls. The scheme allows reduction of the call dropping probability, along with an increase in the bandwidth utilization. The numerical results show that the proposed scheme is capable of attaining negligible handover call dropping probability without sacrificing bandwidth utilization.