• Title/Summary/Keyword: Control Parameter

Search Result 4,554, Processing Time 0.025 seconds

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

Applicability evaluation of velocity profile method by V-ADCP measuring real-time river water use (실시간 하천수사용량 계측을 위한 V-ADCP 유속분포법의 적용성 평가)

  • Song, Jae Hyun;Park, Moon Hyung;Cha, Jun-Ho;Kim, Chi Young
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.83-96
    • /
    • 2019
  • In order to properly manage the river water use, it is necessary to collect reliable data of river water use. However, It is not easy to get credible river water use data in Korea because there are some difficultites in reporting and measuring river water use data. Thus, Han River Flood Control Office has installed and operated measuring facility using V-ADCP on the EOUBO intake open channel in the Gosan-Bongdong station section of the Mankyung river, where the use of agricultural water is large. In this study, the applicability of the V-ADCP velocity profile method was evaluated for real-time river water use. For this reason, the parameter sensitivity of Chiu's 2D velocity distribution equation was analyzed and the optimal parameters based on actual discharge data were calculated. In addition, the characteristics of the velocity profile method were analyzed by comparative evaluation of the rating curve method and the index velocity method.

Hypertensive Retinopathy and the Risk of Hemorrhagic Stroke

  • Thiagarajah, Ramani;Kandasamy, Regunath;Sellamuthu, Pulivendhan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.543-551
    • /
    • 2021
  • Objective : Hemorrhagic stroke (HS) and hypertensive retinopathy are known end organ damage of the brain and eye respectively, with HS having deleterious consequence to the patients. This study is to correlate between hypertensive retinopathy and HS in hypertensive disease. Methods : A control group of hypertensive patients only, and an investigated group of hypertensive HS patients. Fundoscopic examination to determine the grade of retinopathy was performed and then divided into low or high severity hypertensive retinopathy. Clinical and radiological parameter included are demography, vital signs, Glasgow coma scale (GCS) on admission, clot volume, site of clot, Intracerebral hemorrhage (ICH) score and Glasgow outcome scale (GOS). Data were correlated with the severity of hypertensive retinopathy. Results : Fifty patient in the control group and 51 patients in the investigated group were recruited. In the hypertensive HS group, 21 had low severity retinopathy (no or mild retinopathy) accounting for 41.2% and 30 patients had high severity (moderate or severe retinopathy). In the hypertensive patients 49 had low severity and one had high severity (p-value of 0.001). In HS group low severity showed better GCS score of 9-15 on admission (p-value of 0.003), clot volume less than 30 mL (p-value 0.001), and also a better 30 days mortality rate by using the ICH score (p-value 0.006), GOS score of 4 and 5 the low severity retinopathy fair better than the high severity retinopathy (p-value of 0.001), and the relative risk to develop HS in low severity and high severity retinopathy was 0.42 and 29.4, respectively. Conclusion : Hypertensive retinopathy screening could be used as an indicator in hypertensive patient, to evaluate the risk of developing hypertensive HS in the future.

Cryptanalysis of LILI-128 with Overdefined Systems of Equations (과포화(Overdefined) 연립방정식을 이용한 LILI-128 스트림 암호에 대한 분석)

  • 문덕재;홍석희;이상진;임종인;은희천
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.13 no.1
    • /
    • pp.139-146
    • /
    • 2003
  • In this paper we demonstrate a cryptanalysis of the stream cipher LILI-128. Our approach to analysis on LILI-128 is to solve an overdefined system of multivariate equations. The LILI-128 keystream generato $r^{[8]}$ is a LFSR-based synchronous stream cipher with 128 bit key. This cipher consists of two parts, “CLOCK CONTROL”, pan and “DATA GENERATION”, part. We focus on the “DATA GENERATION”part. This part uses the function $f_d$. that satisfies the third order of correlation immunity, high nonlinearity and balancedness. But, this function does not have highly nonlinear order(i.e. high degree in its algebraic normal form). We use this property of the function $f_d$. We reduced the problem of recovering the secret key of LILI-128 to the problem of solving a largely overdefined system of multivariate equations of degree K=6. In our best version of the XL-based cryptanalysis we have the parameter D=7. Our fastest cryptanalysis of LILI-128 requires $2^{110.7}$ CPU clocks. This complexity can be achieved using only $2^{26.3}$ keystream bits.

The Effects of Stair Climbing Training with Functional Electrical Stimulation on Muscle Strength, Balance, and Gait in Patients with Chronic Stroke

  • Koh, Sieun;Choi, Wonjae;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.32-39
    • /
    • 2021
  • Objective: The weakness of muscle strength due to stroke affects the posture control and gait in the patients with stroke. Stroke This study examined the effects of the stair climbing training with functional electrical stimulation on muscle strength, dynamic balance, and gait in individuals with chronic stroke. Design: Randomized controlled trial. Methods: Total forty-eight patients were randomly assigned to the 3 groups. Participants randomly divided to stair climbing training with functional electrical stimulation group (SCT+FES group, n=16), stair climbing training group (SCT group, n=16) and control group (n=16). Subjects in the SCT+FES group and SCT group performed stair walking training with and without functional electrical stimulation for 30 minutes, 3 sessions per week for 4 weeks and all subjects received conventional physical therapy for 30 minutes with 5 sessions per week for 4 weeks. Outcome measurements were assessed using the sit-to stand Test for strength, timed up and go test and modified-timed up and go test for dynamic balance, and 10m walk test and GaitRite system for gait. Results: In the SCT+FES group, subjects have been shown the significant increase in lower extremity strength (p<0.05), significantly improve in dynamic balance (p<0.05), and significantly improve in their temporal gait parameter (p<0.05). The SCT+FES group was significantly better than other groups in all parameters (p<0.05). Conclusions: This result suggested that the SCT+FES may be effective strategy to improve muscle strength, dynamic balance, and gait for individuals with chronic stroke.

Improvement Effect of the Eucommia ulmoides Extracts on CIA-induced Rheumatoid Arthritis Animal Models (두충 추출물의 류마티스관절염 동물모델에 대한 개선 효과)

  • Ji, Joong-Gu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.18-26
    • /
    • 2022
  • The present study aimed to evaluate the effect of Eucommia ulmoides extracts on rheumatoid arthritis biomarker in a CIA-induced DBA/1 mice. For evaluation, Eucommia ulmoides extracts was administered orally at dose of 100 mg/kg/day for 4 weeks after production of an animal model of rheumatoid arthritis and we confirmed the treatments' effects based on serum biomarker, radiological, structural parameter analysis. Compared to the negative control group, the Eucommia ulmoides extracts treatments significantly reduced the serum level of inflammation and immunoglobulin markers (i.e., TNF-α, IgG, and hs-CRP), and significantly decreased the monocyte count of white blood cells. Furthermore, the Eucommia ulmoides extracts treatments effectively preserved the joint destruction, and little the joint deformation. Moreover, compared to the negative control group, the Eucommia ulmoides extracts treatments increased the bone volume, and significantly decreased bone inflammation. The results indicate that the Eucommia ulmoides extracts improved rhrumatoid arthritis symptoms. Thus, the Eucommia ulmoides extracts may be a novel therapeutic option for the management of rheumatoid arthritis.

A Study on the Characteristics Analysis of LLC AC to DC High Frequency Resonant Converter capable of ZVZCS (ZVZCS가 가능한 LLC AC to DC 고주파 공진 컨버터의 특성 해석에 관한 연구)

  • Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.741-749
    • /
    • 2021
  • This paper presents the current-fed type LLC AC to DC high frequency resonant converter capable of ZVZCS(Zero-Voltage and Zero-Current Switching). The current-fed type LLC AC to DC high frequency resonant converter proposed in this paper could operate not only in ZVS(Zero-Voltage Switching) operation by connecting the resonant capacitors(C1, C2) in parallel across the switching devices but also in ZCS(Zero-Current Switching) operation of the secondary diode. The ZVS and ZCS operations can reduce the turn-on loss of the switching devices and the turn-off loss of the secondary diodes, respectively. The circuit analysis of current-fed type LLC AC to DC high frequency resonant converter proposed in this paper is addressed generally by adopting the normalized parameters. The operating characteristics of proposed LLC AC to DC high frequency resonant converter were also evaluated by using the normalized control parameters such as the normalized control frequency(μ), the normalized load resistor(λ) and so on. Based on the characteristic values through the characteristics of evaluation, an example of the design method of proposed LLC AC to DC high frequency resonant converter is suggested, and the validity of the theoretical analysis is confirmed using the experimental results and PSIM simulation.

HI gas kinematics of paired galaxies in the cluster environment from ASKAP pilot observations

  • Kim, Shin-Jeong;Oh, Se-Heon;Kim, Minsu;Park, Hye-Jin;Kim, Shinna
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.70.1-70.1
    • /
    • 2021
  • We examine the HI gas kinematics and distributions of galaxy pairs in group or cluster environments from high-resolution Australian Square Kilometer Array Pathfinder (ASKAP) WALLABY pilot observations. We use 32 well-resolved close pair galaxies from the Hydra, Norma, and NGC 4636, two clusters and a group of which are identified by their spectroscopy information and additional visual inspection. We perform profile decomposition of HI velocity profiles of the galaxies using a new tool, BAYGAUD which allows us to separate a line-of-sight velocity profile into an optimal number of Gaussian components based on Bayesian MCMC techniques. Then, we construct super profiles via stacking of individual HI velocity profiles after aligning their central velocities. We fit a model which consists of double Gaussian components to the super profiles, and classify them as kinematically cold and warm HI gas components with respect to their velocity dispersions, narrower or wider 𝜎, respectively. The kinematically cold HI gas reservoir (M_cold/M_HI) of the paired galaxies is found to be relatively higher than that of unpaired control samples in the clusters and the group, showing a positive correlation with the HI mass in general. Additionally, we quantify the gravitational instability of the HI gas disk of the sample galaxies using their Toomre Q parameters and HI morphological disturbances. While no significant difference is found for the Q parameter values between the paired and unpaired galaxies, the paired galaxies tend to have larger HI asymmetry values which are derived using their moment0 map compared to those of the non-paired control sample galaxies in the distribution.

  • PDF

Copper-Based Compounds against Erwinia amylovora: Response Parameter Analysis and Suppression of Fire Blight in Apple

  • Duck Kyu, Ryu;Mahesh, Adhikari;Dong Hyuk, Choi;Kyung Jin, Jun;Do Hyoung, Kim;Chae Ryeong, Kim;Min Kyu, Kang;Duck Hwan, Park
    • The Plant Pathology Journal
    • /
    • v.39 no.1
    • /
    • pp.52-61
    • /
    • 2023
  • Fire blight, caused by Erwinia amylovora, is one of the major bacterial disease of apple and pear, causing enormous economic losses worldwide. Several control measures against E. amylovora have been reported till date, however, none of them have proved to be effective significantly against the pathogen. In this study, mechanisms of the copper-based control agents (CBCAs): copper oxychloride (COCHL), copper oxide (COX), copper hydroxide (CHY), copper sulfate basic (CSB), and tribasic copper sulfate (TCS) and their disease severity reduction efficacy against E. amylovora were analyzed. Bis-1,3-dibutylbarbituric acid trimethine oxonol, carboxyl fluorescein diacetate succinimidyl ester, and 5-cyano-2,3-ditolyl tetrazolium chloride staining were used to check the damage of membrane potential, cytoplasmic pHin, and respiration of CBCAs-treated E. amylovora, respectively. High disturbance in the membrane potential of E. amylovora was found under COX and COCHL treatments. Similarly, higher significant changes in the inner cytoplasmic pHin were observed under COX, COCHL, and TCS treatment. CHY and COCHL-treated E. amylovora showed a significant reduction in respiration. In vitro bioassay results revealed that CHY, CSB, and TCS at 2,000 ppm reduced the severity of fire blight both in pre- and post-treatment of CBCAs in immature apple fruits and seedlings. Overall, the most effective CBCAs against E. amylovora could be CHY at 2,000 ppm as its showed inhibition mechanisms and disease severity reduction.

Design of Heat and Fluid Flow in Cold Container Using CFD Simulation (CFD 시뮬레이션을 이용한 냉장컨테이너의 열유동 설계)

  • Yun, Hong-Sun;Kwon, Jin-Kyung;Jeong, Hoon;Lee, Hyun-Dong;Kim, Young-Keun
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.396-403
    • /
    • 2008
  • Because thermal non-uniformity of transported agricultural products is mainly affected by cooling air flow pattern in the cold transport equipment, the analysis and control of flowfield is key to optimization of cold transport equipment. The objectives of this study were to estimate the effects of geometric and operating parameters of cold container on the air flow and heat transfer, and find the optimum design parameters for the low temperature level and its uniformity in given cold container with CFD simulations. Existences of ducts, gaps between pallets and geometries of exit as geometric parameters and fan blowing velocity as operating parameter were investigated. CFD simulations were carried out with the FLUENT 6.2 code. The result showed that optimum design condition was bulk loading with no duct, wall exit and 8.0 m/s of fan blowing velocity.