• Title/Summary/Keyword: Contrast-enhanced CT

Search Result 169, Processing Time 0.021 seconds

Evaluation of the Usefulness of a Wireless Signal Device for the Use of Contrast Agent in Computed Tomography (전산화단층촬영에서 조영제 주입에 따른 무선신호기 사용의 유용성평가)

  • Hong, Ki-Man;Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.417-425
    • /
    • 2018
  • The psychological anxiety of radiologists, as well as the patients, is growing with the increasing use of CT contrast agent side effects and the process of extravasation. In this study, a satisfaction survey was conducted regarding the wireless signal device after CT examination in patients and radiologists by employing a wireless signal device during a contrast-enhanced CT examination in order to determine its usefulness to the relieve psychological anxiety, such as anxiety and fear, of patients and radiologists when using contrast agents. The use of a wireless signal device was also intended to help radiologists in dealing with the side effects of contrast agents that may occur during a CT examination and preventing extravasation. Patients aged 20 years or older, who visited the C university hospital in Jeonnam province for 4 months from August to November in 2017, were surveyed. A total number of 90 patients (57 males and 33 females),who agreed to the study after CT examination, were included in the questionnaire survey. Meanwhile, 15 radiologists, who were working at a CT room and had an experience in using a wireless signal device, were surveyed. Patient satisfaction was $6.01{\pm}0.88$ before the use of a wireless signal device and $8.20{\pm}1.06$ after use, thereby showing an increased satisfaction after its use. Radiologist satisfaction was $8.46{\pm}1.06$ after use, thereby not showing a big difference from the mean patient satisfaction. The satisfaction was high at over 8 points in both groups. The contribution to psychological stability with the use of a wireless signal device was $8.98{\pm}0.65$ in patients with prior experience of side effects and $8.00{\pm}1.21$ in patients without prior experience of side effects. In conclusion, it is considered to improve satisfaction with the examination by helping the radiologists in taking immediate action with calling via the wireless signal device and providing the patients and radiologists with psychological stability by reducing their anxiety.

Radiologic Findings of Renal Oncocytomas (신장 호산성과립세포종의 영상의학적 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.26 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • Purpose : To radiologically differentiate renal oncocytoma from other renal solid tumors, we analyzed and characterized, retrogradely, radiologic findings of renal oncocytomas. Materials and Methods : Radiologic findings of pathologically proven renal oncocytoma were analyzed in 9 patients. CT was performed in all patients, ultrasonography in 4 patients and MRI in 3 patients.(51) Results : On ultrasonography, the echogenicity of the mass was slightly more hyperechoic than normal renal parenchyma in all 4 cases. Two cases were homogeneous and the remaining two cases were relatively homogeneous. On CT, all 8 cases showed iso-density to slightly low density compared to normal renal parenchyma and 5 cases were homogeneous but the central portion of the mass was of a slightly lower density than the peripheral portion in 3 cases. All six cases had an arterial phase scan and were heterogeneously enhanced. An irregular, lower-enhancing portion was found in the central portion of the mass. Segmental inversion of contrast enhancement was found in 5 of 6 cases that had a dynamic enhancement study. On MR T1-weighted imaging, the mass was of iso-signal intensity to normal renal parenchyma and the central portion of the mass had a slightly hypo-signal intensity than the peripheral portion. On T2-weighted imaging, 2 cases were heterogeneous; the peripheral portion was of low signal intensity and central portion was of higher signal intensity than normal renal parenchyma. One case was relatively homogeneous and showed a slightly lower signal intensity than that of normal parenchyma, except for a central small portion showing high signal intensity. For 2 cases that had a dynamic study, a segmental inversion of contrast enhancement was noted. Conclusion : Renal oncocytoma is seen as a well-marginated solid mass lesion. On enhanced scans it is heterogeneously enhanced and segmental inversion of contrast enhancement may be seen. The possibility of oncocytoma can be suggested in cases showing these radiologic findings.

  • PDF

Percutaneous Radiofrequency Ablation Guided by Contrast-enhanced Ultrasound in Treatment of Metastatic Hepatocellular Carcinoma after Liver Transplantation

  • Dai, Xin;Zhao, Hong-Qiang;Liu, Run-Hao;Xu, Chang-Tao;Zheng, Fang;Yu, Li-Bao;Li, Wei-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3709-3712
    • /
    • 2012
  • This study evaluated the advantages and applications of contrast-enhanced ultrasound (CEUS)-supported percutaneous radiofrequency ablation (RFA) in the treatment of metastatic hepatocellular carcinoma after liver transplantation, based on clinical details. CEUS-supported percutaneous RFA was adopted to treat 12 patients with hepatic metastatic carcinomas after liver transplantation. The diameters of the metastatic carcinomas varied from 1 cm to 5 cm, and the foci were discovered after 3 months to 12 months. Each focus was diagnosed and localised by CEUS for RFA once or twice. Curative effects were evaluated by CEUS or contrast-enhanced CT after the treatment. The re-examination results at 2 weeks post-treatment showed that the foci of 11 patients were ablated completely, whereas one patient with the largest focus required retreatment by RFA because of a partial residue. No local recurrence was found one month later in the re-examination. CEUS-supported percutaneous RFA in the treatment of hepatic metastatic carcinoma after liver transplantation has the advantages of accurate localisation, good efficacy, easy operation, and minimal invasion without any complications. Therefore, it can be recommended as the preferred therapy for hepatic metastatic carcinoma after liver transplantation.

Enhanced CT-image for Covid-19 classification using ResNet 50

  • Lobna M. Abouelmagd;Manal soubhy Ali Elbelkasy
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.1
    • /
    • pp.119-126
    • /
    • 2024
  • Disease caused by the coronavirus (COVID-19) is sweeping the globe. There are numerous methods for identifying this disease using a chest imaging. Computerized Tomography (CT) chest scans are used in this study to detect COVID-19 disease using a pretrain Convolutional Neural Network (CNN) ResNet50. This model is based on image dataset taken from two hospitals and used to identify Covid-19 illnesses. The pre-train CNN (ResNet50) architecture was used for feature extraction, and then fully connected layers were used for classification, yielding 97%, 96%, 96%, 96% for accuracy, precision, recall, and F1-score, respectively. When combining the feature extraction techniques with the Back Propagation Neural Network (BPNN), it produced accuracy, precision, recall, and F1-scores of 92.5%, 83%, 92%, and 87.3%. In our suggested approach, we use a preprocessing phase to improve accuracy. The image was enhanced using the Contrast Limited Adaptive Histogram Equalization (CLAHE) algorithm, which was followed by cropping the image before feature extraction with ResNet50. Finally, a fully connected layer was added for classification, with results of 99.1%, 98.7%, 99%, 98.8% in terms of accuracy, precision, recall, and F1-score.

Circularity Index on Contrast-Enhanced Computed Tomography Helps Distinguish Fat-Poor Angiomyolipoma from Renal Cell Carcinoma: Retrospective Analyses of Histologically Proven 257 Small Renal Tumors Less Than 4 cm

  • Hye Seon Kang;Jung Jae Park
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.735-741
    • /
    • 2021
  • Objective: To evaluate circularity as a quantitative shape factor of small renal tumor on computed tomography (CT) in differentiating fat-poor angiomyolipoma (AML) from renal cell carcinoma (RCC). Materials and Methods: In 257 consecutive patients, 257 pathologically confirmed renal tumors (either AML or RCC less than 4 cm), which did not include visible fat on unenhanced CT, were retrospectively evaluated. A radiologist drew the tumor margin to measure the perimeter and area in all the contrast-enhanced axial CT images. In each image, a quantitative shape factor, circularity, was calculated using the following equation: 4 x π x (area ÷ perimeter2). The median circularity (circularity index) was adopted as a representative value in each tumor. The circularity index was compared between fat-poor AML and RCC, and the receiver operating characteristic (ROC) curve analysis was performed. Univariable and multivariable binary logistic regression analysis was performed to determine the independent predictor of fat-poor AML. Results: Of the 257 tumors, 26 were AMLs and 231 were RCCs (184 clear cell RCCs, 25 papillary RCCs, and 22 chromophobe RCCs). The mean circularity index of AML was significantly lower than that of RCC (0.86 ± 0.04 vs. 0.93 ± 0.02, p < 0.001). The mean circularity index was not different between the subtypes of RCCs (0.93 ± 0.02, 0.92 ± 0.02, and 0.92 ± 0.02 for clear cell, papillary, and chromophobe RCCs, respectively, p = 0.210). The area under the ROC curve of circularity index was 0.924 for differentiating fat-poor AML from RCC. The sensitivity and specificity were 88.5% and 90.9%, respectively (cut-off, 0.90). Lower circularity index (≤ 0.9) was an independent predictor (odds ratio, 41.0; p < 0.001) for predicting fat-poor AML on multivariable logistic regression analysis. Conclusion: Circularity is a useful quantitative shape factor of small renal tumor for differentiating fat-poor AML from RCC.

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

Vertebral Venous Congestion That May Mimic Vertebral Metastasis on Contrast-Enhanced Chest Computed Tomography in Chemoport Inserted Patients

  • Jeong In Shin;Choong Guen Chee;Min A Yoon;Hye Won Chung;Min Hee Lee;Sang Hoon Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.62-73
    • /
    • 2024
  • Objective: This study aimed to determine the prevalence of vertebral venous congestion (VVC) in patients with chemoport insertion, evaluate the imaging characteristics of nodular VVC, and identify the factors associated with VVC. Materials and Methods: This retrospective single-center study was based on follow-up contrast-enhanced chest computed tomography (CT) of 1412 adult patients who underwent chemoport insertion between January 2016 and December 2016. The prevalence of venous stenosis, reflux, and VVC were evaluated. The imaging features of nodular VVC, including specific locations within the vertebral body, were analyzed. To identify the factors associated with VVC, patients with VVC were compared with a subset of patients without VVC who had been followed up for > 3 years without developing VVC after chemoport insertion. Toward this, a multivariable logistic regression analysis was performed. Results: After excluding 333 patients, 1079 were analyzed (mean age ± standard deviation, 62.3 ± 11.6 years; 540 females). The prevalence of VVC was 5.8% (63/1079), with all patients (63/63) demonstrating vertebral venous reflux and 67% (42/63) with innominate vein stenosis. The median interval between chemoport insertion and VVC was 515 days (interquartile range, 204-881 days). The prevalence of nodular VVC was 1.5% (16/1079), with a mean size of 5.9 ± 3.1 mm and attenuation of 784 ± 162 HU. Nodular VVC tended to be located subcortically. Forty-four patients with VVC underwent CT examinations with contrast injections in both arms; the VVC disappeared in 70% (31/44) when the contrast was injected in the arm contralateral to the chemoport site. Bevacizumab use was independently associated with VVC (odds ratio, 3.45; P < 0.001). Conclusion: The prevalence of VVC and nodular VVC was low in patients who underwent chemoport insertion. Nodular VVC was always accompanied by vertebral venous reflux and tended to be located subcortically. To avoid VVC, contrast injection in the arm contralateral to the chemoport site is preferred.

Penetrating Cardiac Injury and Traumatic Pericardial Effusion Caused by a Nail Gun

  • Miranda, Willem Guillermo Calderon;Fuentes, Edgardo Jimenez;Hernandez, Nidia Escobar;Salazar, Luis Rafael Moscote;Parizel, Paul M.
    • Journal of Trauma and Injury
    • /
    • v.30 no.1
    • /
    • pp.21-23
    • /
    • 2017
  • Penetrating cardiac injury caused by nail gun is an uncommon life-threatening condition characterized by a rapidly severe hemodynamic status compromise. We report non-contrast-enhanced CT findings of a right ventricle myocardium injury leading to a fluid collection in the pericardial space with the same attenuation as blood. The CT findings well depicted the pathological feature of a significant cardiac injury and may be helpful for the surgical management.

Computed tomographic features of focal lipogranulomatous lymphangitis for differentiating from malignant intestinal lesions in a dog

  • Hye-Won Lee;Jin-Woo Jung;Seungjo Park;Kija Lee;Sang-Kwon Lee
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.25.1-25.6
    • /
    • 2023
  • An eight-year-old Maltese dog presented with diarrhea and anorexia. Ultrasonography revealed marked focal wall thickening with loss of layering in the distal ileum. Contrast-enhanced computed tomography (CT) revealed a preserved wall layer with hypoattenuating middle wall thickening. In some segments of the lesion, small nodules protruding toward the mesentery from the outer layer were observed. Histopathology revealed focal lipogranulomatous lymphangitis (FLL) with lymphangiectasia. This is the first report to describe the CT features of FLL in a dog. CT features of preserved wall layers with hypoattenuating middle wall thickening and small nodules can assist in diagnosing FLL in dogs.

Solitary Necrotic Nodules of the Liver Mimicking Hepatic Metastasis: Report of Two Cases

  • Kwon-Ha Yoon;Ki Jung Yun;Jung-Min Lee;Chang Guhn Kim
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.165-168
    • /
    • 2000
  • We present two cases of solitary necrotic nodules of the liver which on radiologic images mimicked hepatic metastasis. Solitary necrotic nodule of the liver is a rare but benign entity which histopathologically consists of an outer fibrotic capsule with inflammatory cells and a central core of amorphous necrotic material. The lesion was seen on contrast-enhanced CT as an ovoid-shaped hypoattenuating nodule; on CT during hepatic arteriography as enhancing nodule; on intraoperative US as a target-appearing hypoechoic nodule; on T2WI as a hyperintensity nodule, and on dynamic MR as a subtle peripheral enhancing nodule. Although the radiologic features are not specific, solitary necrotic nodule of the liver should be included in the differential diagnosis of hepatic metastasis.

  • PDF