• 제목/요약/키워드: Contrast to Noise Ratio

검색결과 289건 처리시간 0.032초

스피커 어레이를 이용한 개인용 모니터와 TV 오디오 시스템 (Personal monitor & TV audio system by using speaker array)

  • 이찬희;장지호;박진영;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.638-643
    • /
    • 2007
  • With development of high display quality of TV and Monitor, personal audio system is arising great interest. In this study, we applied a method to make a good bright zone around the user and dark zone to other region by maximizing the ratio of sound energy between the bright and dark zone. We have attempted to use a line speaker array system to localize the sound in our listening zone. It depends on the size of the zone and array parameters, for example, array size, speaker spacing, wave length of sound.

  • PDF

High-Quality and Robust Reversible Data Hiding by Coefficient Shifting Algorithm

  • Yang, Ching-Yu;Lin, Chih-Hung
    • ETRI Journal
    • /
    • 제34권3호
    • /
    • pp.429-438
    • /
    • 2012
  • This study presents two reversible data hiding schemes based on the coefficient shifting (CS) algorithm. The first scheme uses the CS algorithm with a mean predictor in the spatial domain to provide a large payload while minimizing distortion. To guard against manipulations, the second scheme uses a robust version of the CS algorithm with feature embedding implemented in the integer wavelet transform domain. Simulations demonstrate that both the payload and peak signal-to-noise ratio generated by the CS algorithm with a mean predictor are better than those generated by existing techniques. In addition, the marked images generated by the variant of the CS algorithm are robust to various manipulations created by JPEG2000 compression, JPEG compression, noise additions, (edge) sharpening, low-pass filtering, bit truncation, brightness, contrast, (color) quantization, winding, zigzag and poster edge distortion, and inversion.

Tagline 간격의 조절을 통한 SPAMM 영상에서의 Tagging 대조도 대 잡음비의 변화 (The Variation of Tagging Contrast-to-Noise Radio (CNR) of SPAMM Image by Modulation of Tagline Spacing)

  • 강원석;최병욱;최규옥;이상호;홍순일;정해조;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.224-228
    • /
    • 2002
  • MR영상에 Spatial Modulation of Magnetization (SPAMM)과 같은 lagging 기법을 이용하여 심근의 움직임을 분석하여 임상에 적용하려는 많은 노력들이 이루어지고 있다. Tagging 대조도는 자동 tagline 검출 알고리즘을 사용하는 경우, 그 정확도에 영향을 미칠 수 있으며, 이는 tagline들 간의 간격에 의해 영향을 받을 수 있다. 본 연구의 목적은 SPAMM 영상에서 tagline 간격과 tagging 대조도와의 관계를 생체내 연구를 통해 알아보고자 하였다. 두 명의 건강한 지원자를 대상으로 1.5T MR 시스템에서 SPAMM 기반의 ECG triggered MR 영상을 획득하였다. 영상을 획득할 때, 먼저 3.6 mm에서 9.6 mm 사이의 간격을 가지는 수평 tagging stripe pattern의 tagline을 가하였다. 심실의 영상은 심장주기가 진행되는 동안 field echo EPI (FE-EPI) 기법을 이용하여 심실 중간 부분에서 얻었다 각 영상에 대한 tagging contrast-to-noise ratio (CNR)는 IDL을 이용한 프로그램을 사용하여 측정하였다. 분석 결과는, 심근의 수축이 진행되는 동안, tagline 간격이 좁은 경우 CNR은 급격한 감소를 나타내었으나, 간격이 넓은 경우에서는 CNR 감소 현상이 보이지 않았다. 같은 심장 위상에서, CNR은 tagline 간격이 넓어짐에 따라 증가하는 경향을 보였다. 특히, 완전히 수축한 심장 위상에서는, CNR의 변화가 다른 위상일 때와 비교해서 그 증가율이 높음을 알 수 있었다. 이러한 양상은 움직임이 없는 다른 주변 조직에서는 관찰되지 않았다. 결론적으로, 본 연구에서는 lagging 대조도가 tagline 간격 및 심근의 수축에 영향을 받을 수 있음을 알 수 있었으며, 앞으로 정확한 심근 움직임 연구를 위한 기초 자료로 쓰여질 수 있을 것이라 생각된다.

  • PDF

고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 조영제의 유용성 (The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography)

  • 최관우;김윤신;손순룡;이호범;나사라;민정환;유병규;이종석
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5682-5688
    • /
    • 2013
  • 본 연구는 고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 1mmol/mL 조영제를 사용함으로써 현재 대다수의 의료기관에서 사용하고 있는 0.5mmol/ml 조영제 대비 신호대잡음비와 대조도대잡음비를 높여 진단적 가치를 극대화 시키는데 목적을 두었다. 연구방법은 2012년 1월부터 2013년 6월까지 가돌리늄 함유량에 따른 대조도 차이를 알아보기 위하여 0.5mmol/mL 함유량을 가진 기존의 조영제를 사용한 20명과 1mmol/mL 함유량을 가진 새로운 조영제를 사용한 27명 등 총 47명의 환자를 연구대상으로 하였으며, 고관절의 관절공간과 인접한 근육조직인 장요근, 그리고 대퇴골두의 신호강도를 각각 측정한 후 신호대잡음비와 대조도대잡음비를 비교 평가하였다. 연구 결과, 가돌리늄 함유량이 높은 1mmol/mL 조영제 사용 시 SNR은 관절공간 27.00%(p<.01), 대퇴골두 30.01%(p<.01), 장요근 18.74%(p>.05) 높았고, 대조도대잡음비 또한 신호대잡음비와 같이 관절공간과 장요근, 관절공간과 대퇴골두 모두 28.31%(p<.01)와 26.74%(p<.01)로 높았다. 결론적으로 단위 부피당 가돌리늄 함유량이 높은 1mmol/mL 조영제를 사용하면 높은 T1 단축효과로 인해 신호강도가 커지고 대조도 차이가 큰 영상을 획득 할 수 있어, 진단적 가치가 높은 영상을 얻을 수 있다. 본 연구는 고관절의 자기공명관절조영검사에 대한 1mmol/mL 조영제의 유용성을 최초로 증명하여 진단적 가치를 높일 수 있는 방안을 제시하였다는 데에 학문적 가치가 크다고 하겠다.

Multi-Element Defocusing을 이용한 Tx/Rx 양방향 빔포밍 (Tx/Rx Bidirectional Beamforming Using Multi - Element Defocusing)

  • 이용호;황재섭;송태경;안영복
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.219-220
    • /
    • 1998
  • Although a single-element synthetic aperture system can produce high-resolution beam profile, it is not a highly practical system because of its low signal to noise ratio against conventional system's. A multi-element synthetic aperture processing has been proposed with defocusing in this paper. A multi element subaperture defocused to emulate a single element spatial response with high acoustic power. The results have higher signal to noise and better contrast resolution than conventional synthetic aperture method.

  • PDF

범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구 (Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study)

  • 반영각;황동훈;김정열;강천구;김재삼
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.49-53
    • /
    • 2016
  • 최근 Cadmium-zinc-telluride (CZT) 반도체를 이용한 심장전용 감마카메라가 심장 핵의학 검사에 사용되고 있다. 본 연구는 기존 NaI(Tl) 신틸레이터를 사용한 감마카메라와 성능을 비교해 보고자 한다. CZT반도체를 사용한 심장전용 감마카메라(DSPECT, Spectrum-dynamic)와 범용 신틸레이터 SPECT 감마카메라(Infinia, GE)를 사용하여 연구를 진행했다. 방사성 동위원소는 $^{99m}TcO^{-4}$를 사용하고, 일반 임상 심장핵의학 검사에 사용된 조건을 실험 조건으로 설정 했다. NEMA 2001, 3 line phantom을 사용하여 반치폭(full width at half maximum, FWHM)을 측정하여 공간분해능(Spatial resolution)을 비교했다. 심장 팬텀을 사용하여 대조도대잡음비(Contrast to noise, CNR)를 비교하여 영상을 평가했다. 그리고 팬텀의 시간 당 MBq당 계수를 측정하여 민감도도 평가했다. NaI (Tl) 신틸레이터를 사용한 범용SPECT 감마카메라와 CZT 반도체를 사용한 심장 전용 감마카메라의 영상평가에서 감도는 $52.83counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$$195.83counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$로 나왔고, 공간분해능은 16.90 mm과 9.47 mm로 나왔다. 그리고 대조도대 잡음비는 3.6 과 4.2 로 나왔다. 기존 카메라를 이용한 심장 핵의학 영상과 비교하여 CZT를 사용한 심장 전용 감마카메라는 감도 및 공간분해능, 대조도대잡음비가 기존 감마카메라와 비교하여 월등하여 임상에서 환자의 피폭선량 저감과 검사 시간 단축, 높은 분해능의 영상으로 환자 만족도에 큰 영향을 줄 것으로 사료 된다.

  • PDF

Mura 검출을 위한 Model Fitting 및 Least Square Estimator의 비교 (Comparison of Model Fitting & Least Square Estimator for Detecting Mura)

  • 오창환;주효남;류근호
    • 제어로봇시스템학회논문지
    • /
    • 제14권5호
    • /
    • pp.415-419
    • /
    • 2008
  • Detecting and correcting defects on LCD glasses early in the manufacturing process becomes important for panel makers to reduce the manufacturing costs and to improve productivity. Many attempts have been made and were successfully applied to detect and identify simple defects such as scratches, dents, and foreign objects on glasses. However, it is still difficult to robustly detect low-contrast defect region, called Mura or blemish area on glasses. Typically, these defect areas are roughly defined as relatively large, several millimeters of diameter, and relatively dark and/or bright region of low Signal-to-Noise Ratio (SNR) against background of low-frequency signal. The aim of this article is to present a robust algorithm to segment these blemish defects. Early 90's, a highly robust estimator, known as the Model-Fitting (MF) estimator was developed by X. Zhuang et. al. and have been successfully used in many computer vision application. Compared to the conventional Least-Square (LS) estimator the MF estimator can successfully estimate model parameters from a dataset of contaminated Gaussian mixture. Such a noise model is defined as a regular white Gaussian noise model with probability $1-\varepsilon$ plus an outlier process with probability $varepsilon$. In the sense of robust estimation, the blemish defect in images can be considered as being a group of outliers in the process of estimating image background model parameters. The algorithm developed in this paper uses a modified MF estimator to robustly estimate the background model and as a by-product to segment the blemish defects, the outliers.

퍼지적분을 이용한 영상품질의 객관적이고 정량적 평가: 팬톰 연구 (Objective and Quantitative Evaluation of Image Quality Using Fuzzy Integral: Phantom Study)

  • 김성현;서태석;최보영;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.201-208
    • /
    • 2008
  • 물리적 평가(physical evaluation)가 영상품질의 객관화와 정량화를 위한 토대를 제공함에도 불구하고, 부정확하고 가변적인 특성을 지닌 주관적 평가(subjective evaluation)가 영상평가에 중요한 역할을 하게 된다. 본 연구에서는 디지털 방사선 영상의 물리적 평가와 주간적 평가의 단점을 상호 보완하고 객관적 정량화를 위한 새로운 방법을 제안하고자 한다. 임상에 사용되고 있는 4대의 디지털 방사선 영상 촬영장치로부터 동일한 임상조건에서 흉부 팬톰 영상을 획득하였다. 물리적 영상평가를 위하여 디지털 흉부 팬톰 내에서 3개의 영역(폐, 심장, 그리고 복부)에 존재하는 CNR (contrast-to-noise ratio)를 측정하였고 분할(segmentation)과 정합(registration)등 다양한 영상처리기술이 적용되었다. 주관적 평가는 5명의 관찰자에 의한 저 대조도 물체의 식별 정도를 점수화 하였다. 두 평가의 특성을 보완 및 결합하고자 퍼지적분 이론이 도입되었다. 4대의 시스템으로부터의 평가결과가 비교되었으며, 물리적 평가와 주관적 평가가 항상 비례하지 않음을 보였다. 물리적 평가에서는 높은 점수를 보였던 시스템이 주관적 평가에서는 상대적으로 낮은 평가를 보였다. 본 연구에서 제안한 퍼지적분에 의한 영상평가의 정량화는 물리적 평가와 주관적 평가를 모두 포함하는 총체적인 평가 방법이며, 다양한 영상품질 평가에 유용할 것이라 사료된다.

  • PDF

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

맘모패드의 새로운 재질에 관한 평가 (Evaluation of New Material Mammopad)

  • 문영주;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.265-270
    • /
    • 2019
  • Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.