• 제목/요약/키워드: Contrast phase

검색결과 833건 처리시간 0.028초

TEM 관련 이론해설 (3): 영상 형성이론과 회절이론 (Theory of Imaging And Diffraction)

  • 이확주
    • Applied Microscopy
    • /
    • 제33권3호
    • /
    • pp.169-178
    • /
    • 2003
  • 영상이론과 회절 이론을 같은 비중으로 다루고 이들과의 관계를 나타내는 wave optics 이론을 소개하였다. 결맞는 파동 이론과 결 안맞는 파동이론 사이의 차이를 나타내고 Abbe이론과 여러 가지 phase contrast 이론들을 small angle 근사로 접근하였다. 마지막으로 다중 성분 시스템에 대한 파동 광학의 수학적인 방법의 적용을 소개하였다.

Effects of Contrast Phases on Automated Measurements of Muscle Quantity and Quality Using CT

  • Dong Wook Kim;Kyung Won Kim;Yousun Ko;Taeyong Park;Jeongjin Lee;Jung Bok Lee;Jiyeon Ha;Hyemin Ahn;Yu Sub Sung;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1909-1917
    • /
    • 2021
  • Objective: Muscle quantity and quality can be measured with an automated system on CT. However, the effects of contrast phases on the muscle measurements have not been established, which we aimed to investigate in this study. Materials and Methods: Muscle quantity was measured according to the skeletal muscle area (SMA) measured by a convolutional neural network-based automated system at the L3 level in 89 subjects undergoing multiphasic abdominal CT comprising unenhanced phase, arterial phase, portal venous phase (PVP), or delayed phase imaging. Muscle quality was analyzed using the mean muscle density and the muscle quality map, which comprises normal and low-attenuation muscle areas (NAMA and LAMA, respectively) based on the muscle attenuation threshold. The SMA, mean muscle density, NAMA, and LAMA were compared between PVP and other phases using paired t tests. Bland-Altman analysis was used to evaluate the inter-phase variability between PVP and other phases. Based on the cutoffs for low muscle quantity and quality, the counts of individuals who scored lower than the cutoff values were compared between PVP and other phases. Results: All indices showed significant differences between PVP and other phases (p < 0.001 for all). The SMA, mean muscle density, and NAMA increased during the later phases, whereas LAMA decreased during the later phases. Bland-Altman analysis showed that the mean differences between PVP and other phases ranged -2.1 to 0.3 cm2 for SMA, -12.0 to 2.6 cm2 for NAMA, and -2.2 to 9.9 cm2 for LAMA.The number of patients who were categorized as low muscle quantity did not significant differ between PVP and other phases (p ≥ 0.5), whereas the number of patients with low muscle quality significantly differed (p ≤ 0.002). Conclusion: SMA was less affected by the contrast phases. However, the muscle quality measurements changed with the contrast phases to greater extents and would require a standardization of the contrast phase for reliable measurement.

Hepatic Angiomyolipoma: Contrast Patterns with SonoVue-enhanced Real-time Gray-scale Ultrasonography

  • Wei, Rui-Xue;Wang, Wen-Ping;Ding, Hong;Huang, Bei-Jian;Li, Chao-Lun;Fan, Pei-Li;Hou, Jun;He, Nian-An
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권2호
    • /
    • pp.493-497
    • /
    • 2012
  • This study was conducted to retrospectively evaluate the pattern of contrast enhancement with SonoVue on gray-scale ultrasonography of hepatic angiomyolipoma (HAML). Imaging features of 33 pathologically proven HAML lesions in 33 patients who underwent baseline ultrasound and contrast-enhanced ultrasonography (CEUS) were assessed retrospectively. All lesions were enhanced in the arterial phase and showed whole-tumor filling in. Thirty-two of 33 (97%) lesions showed early positive enhancement in the arterial phase. Twenty-three of these exhibited isoechoic or hyperechoic features in the portal phase. HAML demonstrate characteristic manifestations with SonoVue-enhanced real-time gray-scale ultrasonography.

Theoretical Study for the ITO/Si based High Contrast Grating Structure with Focusing Capability and its Fabrication

  • Kim, J.Y.;Yeon, K.H.;Kyhm, J.;Cho, W.J.;Kim, T.J.;Kim, Y.D.;Song, J.D.
    • Applied Science and Convergence Technology
    • /
    • 제24권6호
    • /
    • pp.250-253
    • /
    • 2015
  • High contrast grating (HCG) is the structure made up of the sub-wavelength grating of high-index and the surrounding layer of low-index, which reveals high contrast between two materials. Its advantages include high reflectivity over a broad bandwidth, polarization and wavelength selectivity, optical high-Q resonator, and phase modulation. In this work, the HCG structure comprising of indium tin oxide (ITO) and Silicon (Si), for the surrounding layer and the grating layer respectively, was studied. Its theoretical model was established, and transmittance, phase and optical behavior were calculated by rigorous coupled-wave analysis and finite element method. Furthermore, the established structure was fabricated to validate its feasibility. The fabricated structure shows the focusing capability whose length is about $10{\mu}m$, and the feasibility of the structure was demonstrated. It is also meaningful that ITO layer can contribute to the fabrication of the HCG structure, leading to enable the structure to be electrical-driven.

PHENOL이 미고정(未固定) 조상아세포(造象牙細胞)에 미치는 영향(影響)에 관(關)한 위상차현미경적(位相差顯微鏡的) 연구(硏究) (A PHASE CONTRAST MICROSCOPIC STUDY OF THE EFFECT OF PHENOL ON UNFIXED ODONTOBLAST)

  • 홍경택
    • 대한치과보철학회지
    • /
    • 제17권1호
    • /
    • pp.47-59
    • /
    • 1979
  • In order to study the morphologic changes of the unfixed odontoblasts suspended in phenol solution of several different concentrations, the author carried out the extraction of lower incisor of S-D strain rats to collect the odontoblasts, and the cells obtained were suspended immediately in saline solution. After observing the odontoblasts in fresh state, the saline solution was substituted with 0.125%, 0.25% 0.5%, 1% and 2% diluted phenol solutions. The morphologic changes were examined with phase contrast microscope at intervals of 10, 30, and 60 minutes. The results were as follows: 1. In saline solution the odontoblast showed cytoplasmic swelling, slender cytoplasmic process, thick rim nuclear membrane with increased dark contrast, and prominent nucleoli and chromatin granules with lapse of time intervals. In accordance with time intervals, blisters appeared in the supranuclear zone and increased its size and moved outward of the cytoplasmic membrane resulting detachment from the cell membrane. The phase dark cytoplasmic granules were increased in its dark contrast and in its size. 2. In 0.125% and 0.25% phenol solution, the odontoblasts and its nucleus shrunk immeidately and its contrast of cellular components was increased. With the lapse of time, the phase-dark granules in cytoplasm were aggregated, and several blisters were formed in and out of the cells. The outline of cytoplasmic membrane was also obscured. 3. In 0.5% phenol solution, the necleus shrunk at once, but soon after it revealed karyolysis accompanying dark contrast of neclear components such as nuclear membrane, nucleoli, and chromatin granules. On the contrary, the cytoplasmic granules showed aggregation and increased dark contrast, small and large blisters were formed in and out of the odontblasts and the outline of cytoplasmic membrane became obscured. 4. In 1% phenol solution, it showed shrinkage of odontblasts and its nuclei with thick rim nuclear membrane, aggregation of chromatin granules and occasional karyorrhexis. The dark contrast of cytoplasmic granules was increased and aggregated each other. But the blister formation could not be found. 5. In 2% phenol solution, it showed the shrinkage of odontoblasts and pyknotic nuclei with increased dark contrast of nucleoli and chromatin granules. The number of cytoplasmic granules was decreased by aggregation. But the blister formation could not be found as in 1% phenol solution.

  • PDF

Identification of ginseng root using quantitative X-ray microtomography

  • Ye, Linlin;Xue, Yanling;Wang, Yudan;Qi, Juncheng;Xiao, Tiqiao
    • Journal of Ginseng Research
    • /
    • 제41권3호
    • /
    • pp.290-297
    • /
    • 2017
  • Background: The use of X-ray phase-contrast microtomography for the investigation of Chinese medicinal materials is advantageous for its nondestructive, in situ, and three-dimensional quantitative imaging properties. Methods: The X-ray phase-contrast microtomography quantitative imaging method was used to investigate the microstructure of ginseng, and the phase-retrieval method is also employed to process the experimental data. Four different ginseng samples were collected and investigated; these were classified according to their species, production area, and sample growth pattern. Results: The quantitative internal characteristic microstructures of ginseng were extracted successfully. The size and position distributions of the calcium oxalate cluster crystals (COCCs), important secondary metabolites that accumulate in ginseng, are revealed by the three-dimensional quantitative imaging method. The volume and amount of the COCCs in different species of the ginseng are obtained by a quantitative analysis of the three-dimensional microstructures, which shows obvious difference among the four species of ginseng. Conclusion: This study is the first to provide evidence of the distribution characteristics of COCCs to identify four types of ginseng, with regard to species authentication and age identification, by X-ray phase-contrast microtomography quantitative imaging. This method is also expected to reveal important relationships between COCCs and the occurrence of the effective medicinal components of ginseng.

Ultrasonic Image of the Side Drilled Holes in SS Reference Block as Combining Bases of Support for Spatial Frequency Response

  • 구길모;송철화;백원필;강희영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.322-326
    • /
    • 2008
  • In this paper, we have studied the images which have been reconstructed by using combination of images acquired by the variation of operating frequency. When inner images have been reconstructed, they have been superposed by the surface state effect. In this case, the images of the phase object can be enhanced by the contrast of inner images. There is a kind of specimen, one is a reference block having 1/4T, 1/2T, 3/4T side drilled holes as main run piping material of the steam generator in nuclear power plants. It has been shown that the two results of defect shapes have better than before in this processing and phase contrast grow about twice. And we have constructed the acoustic microscope by using a quadrature detector that enables to acquire the amplitude and phase of the reflected signal simultaneously. Further more we have studied the reconstruction method of the amplitude and phase images, the enhancement method of the defect images' contrast.

  • PDF

축 방향 공간주파수 대역의 확장을 통한 고체 내부영상 개선 (The Enhancement of Inner-solid Image by the Bandwidth Increment of Vertically Spatial Frequency)

  • 구길모;김상백;김현;전계석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.176-180
    • /
    • 2001
  • In this paper, we have studies the images have been reconstructed by using combination of images which has been acquired by the variation of operating frequency. When inner images has been reconstructed, inner image has been superposition by surface state effect. In this case, image enhancement the phase object and enhance the contrast of inner image. In the result of the specimen for the round defect with 2mm diameter, for the types of the depth are 1.5mm, 2mm, 2.5mm, and 3mm, it has been show that the shape of defect has better than before this processing and phase contrast grow large twice. And we have constructed the acoustic microscope by using quadrature detector that is able simultaneously to acquired the amplitude and phase of the reflected signal. Father more we have studied the reconstruction method of the amplitude and phase images and the enhancement method of the defect images' contrast.

  • PDF

Phase Imaging of Worn Surface of TiN Coating and Interpretation by Force Spectroscopy

  • Hyo Sok;Chizhik, S-A;I Luzinov
    • KSTLE International Journal
    • /
    • 제1권2호
    • /
    • pp.69-75
    • /
    • 2000
  • The paper compares topography, phase contrast and force spectroscopy in atomic force microscopy data for evaluating the microheterogeneity of surface layer. The worn surface of ion-plated TiN coating was measured using both a laboratory-built and a commercial AFM. The results of analysis revealed structural and micromechanical heterogeneity of the worn surfaces. We demonstrated that the phase image allows relatively qualitative estimation of elastic modulus of the sample surface. The tribolayer formed in the worn surface possessed much lower stiffness than the original coating. It is shown that the most stable phase imaging is provided with a stiff cantilever. In this case, phase contrast is well conditioned, first of all, by microheterogeneity of elastic properties of the investigated surfaces. In this study an attempt was also made to correlate the results of phase imaging with that of the farce spectroscopy. The joint analysis of information on the surface properties obtained by the phase imaging and quantitative data measured with the force spectroscopy methods allows a better understanding of the nature of the surface micromechanical heterogeneity.

  • PDF

경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성 (Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy)

  • 임정환;송준혁;신규만;김성학
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF