Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
Journal of Magnetics
/
제19권2호
/
pp.185-191
/
2014
In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.
이 연구의 목적은 Roadmap 영상에서 화질에 영향을 미치는 인자들을 알아보기 위한 것으로, 조영제의 희석률, Collimation Field, Flow Rate를 변화하여 연구를 하였다. 화질의 정량적인 평가를 위해, 아크릴를 이용하여 3mm 혈관모형의 Water Phantom을 자체 제작하였고, 자체 제작한 혈관모형의 Water Phantom으로 Roadmap 영상을 획득하고, SNR(Signal to Noise Ratio)과 CNR(Contrast to Noise Ratio)을 분석하였다. CM : N/S 희석률 변화에 대한 연구에서 CM : N/S 희석률을 (100%~10% : 100%)로 변화를 주었으며, 혈관모형 Water Phantom을 이용하여 촬영한 Roadmap 영상의 SNR과 CNR의 측정 결과 CM에 N/S 희석률이 높아질수록 SNR의 측정값이 점차적으로 낮아짐을 나타났고, CNR의 측정값도 점차적으로 낮아짐을 나타났다. 결론적으로 CM : N/S의 희석률이 높아질수록 SNR과 CNR 낮아짐을 확인하였고, CM : N/S의 희석률(100%~70 : 30%)에서 유의한 이미지를 얻을 수 있음을 확인하였다. Collimation Field 변화에 대한 연구에서 혈관모형 Water Phantom을 이용하여 Colimation Field를 혈관모형 중심으로 좌, 우 2 cm 간격으로 좁히면서 0 cm, 2 cm, 4 cm, 6 cm, 8 cm 10 cm, 12 cm으로 각각 변화를 주었으며, Roadmap을 촬영한 영상의 SNR과 CNR의 측정 결과는 Collimation Field를 혈관모형 중심으로 좁힐수록 SNR과 CNR의 측정값이 증가하는 것을 확인할 수 있었다. Flow rate 변화에 대한 연구에서 Autoinjector의 Volume을 15로 일정하게 하고, Flow Rate를 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 으로 각각 변화를 주었다. 혈관모형 Water Phantom을 이용하여 Roadmap 영상을 촬영한 이미지의 SNR과 CNR의 측정 결과 Flow Rate를 증가했을 때, SNR의 측정값이 점차적으로 감소하다가 Flow Rate 9~10에서 SNR의 측정값이 점차적 증가를 보였고, CNR의 측정값도 점차적으로 감소하다가 Flow Rate 9~10에서 CNR의 측정값이 점차적으로 증가를 보였다. 그러나 ROI Mean 값과 Background Mean 값으로 SNR과 CNR의 상관관계를 확인할 수 없었다. 상관관계를 확인하기 위해 Flow Rate 변화에 따른 Roadmap 연구는 향후 더 많은 연구로 확인해야 할 것으로 사료된다. 결론적으로 Roadmap 영상의 화질에 영향을 미치는 인자들을 알아보기 위해 조영제의 희석률, Collimation Field, Flow Rate 변화에 대한 연구에서 조영제에 N/S의 희석률이 증가할수록 SNR과 CNR이 낮아져 화질과 대조도가 낮아지는 것을 확인하였으며, Collimation Field를 좁힐수록 SNR과 CNR이 증가하여 화질과 대조도가 높아지는 것을 확인하였다. 그러나 Flow Rate 변화에 대한 연구에서는 상관관계를 확인할 수 없었다. 검사 및 시술을 할 때 신장의 영향을 최소화하기 위해 적절한 조영제 농도 선택과 대조도 향상 및 피폭 감소를 위한 적절한 Collimation Field를 사용하는 것이 유용할 것으로 판단된다.
유방암 환자가 매년 증가함에 따라 BSGI 검사에 대한 의존도가 높아지고 검사 건수가 증가하고 있는 추세이다. 하지만 국내에서 BSGI 검사는 각 기관의 상황 및 업체권고에 따라 검사 프로토콜을 적용하고 있으며 관련 연구가 미비한 실정이다. 그러므로 본 연구에서는 영상의 질을 평가할 수 있는 팬텀을 자체적으로 제작하여 검사 프로토콜에 대해 고찰하고자 하였다. Dilon 6800 BSGI 장비를 이용하여 팬텀 내 구의 크기는 5단계로 구분하여 제작하여 실험하였다. 방사성동위원소는 $^{99m}TcO_4$를 사용하여 배후방사능과 관심영역의 비율을 2 : 4 : 8로 구분하였으며 5, 7, 10분 영상을 획득하였다. 획득된 영상은 각 구의 크기에 따라 관심영역을 설정하고 정량적, 정성적 분석을 시행하였다. 획득된 데이터는 SPSS ver.18.0을 통해 통계 분석하였다. 정량적, 정성적 분석 결과, 방사성동위원소의 주입량에 따른 각 구의 계수율은 주입량이 많을수록 계수율이 증가하였고, 구의 크기가 클수록 계수율이 증가하는 성향을 나타냈다(p<0.005). 영상획득시간에 따른 각 구의 계수율은 획득시간이 길수록 계수율이 증가하였고, 구의 크기가 클수록 증가하는 성향을 나타냈다(p<0.005). 방사성동위원소의 주입량에 따른 각 구의 대조도 잡음비는 주입량이 많을수록 증가하는 성향을 나타냈고, 8배 비율의 획득영상에서 대조도 잡음비가 가장 높았다. 또한 영상획득시간에 따른 각 구의 대조도 잡음비는 획득시간이 길수록 증가하는 성향을 나타냈고, 7분 획득영상에서 대조도 잡음비가 가장 높았다(p<0.005). 자체적으로 제작한 팬텀을 통한 정량적, 정성적 평가에서 통계적으로 유의한 차이가 있었으며, 팬텀의 유용성을 확인할 수 있었다. 또한 본 연구를 통해 장비 특성과 환경을 고려하여 BSGI 검사 프로토콜을 확인하고 활용한다면 보다 임상적 가치가 높을 것으로 사료된다.
The ability to recognize human emotion is one of the hallmarks of human-robot interaction. Hence this paper describes the realization of emotion recognition. For emotion recognition from voice, we propose a new feature called frequency range of meaningful signal. With this feature, we reached average recognition rate of 76% in speaker-dependent. From the experimental results, we confirm the usefulness of the proposed feature. We also define the noise environment and conduct the noise-environment test. In contrast to other features, the proposed feature is robust in a noise-environment.
본 연구는 심장 혈관 조영술의 투시 영상과 씨네 영상을 획득하는 데 있어서 초당 프레임 횟수를 변화함에 따라 흡수선량과 획득 영상의 화질의 추이를 살펴보는 것을 목적으로 한다. 또, FOV 확대와 Live Zoom이라는 두 가지 확대 모드에 따른 변화도 고찰 대상으로 한다. 인체모형 팬텀을 심장 혈관 조영장치 위에서 초당 프레임 횟수를 7.5, 15, 30 f/s로 설정하고 두 가지 확대 모드에 대하여 각각 5회씩 촬영하였다. 선량의 척도로서는 흡수선량과 에어 커머가 사용되었고, 화질 평가의 척도로는 잡음의 세기로서의 표준 편차(SD), 신호 대 잡음비(SNR)와 대조도 대 잡음비(CNR) 등을 활용하였다. 초당 프레임 횟수가 30부터 15, 7.5 f/s로 감소되었을 때, DAP와 에어 커머는 동일한 비율로 감소하였으나, 화질의 척도인 SD, SNR과 CNR은 거의 변화가 없었다. 확대 모드에의 의존도에 관해서는, Live Zoom이 FOV 확대와 비교하였을 때, DAP, 에어 커머와 SD에 대해서는 통계적 의미 있는 차이를 보이지 않았으나, SNR과 CNR에 있어서는 통계적 유의미한 개선을 보였다. 이러한 실험 결과에 의하여, 초당 프레임 횟수는 화질의 열화 없이 되도록 낮게 설정하는 것이 가능하며, 확대 모드도 추가적인 선량 없이 실시간 확대가 가능한 Live Zoom 모드를 적극적으로 활용 가능하며 이는 화질의 여러 척도의 저하를 가져오지 않음을 알 수 있었다.
Purpose: To report initial experience and evaluate feasibility of cervical carotid artery contrast-enhanced MR angiography (CEMRA) using whole body coil at 3.0T Method: Twenty-eight patients (14 male, ages 41-80, mean age 63) underwent CEMRA at the 3.0T using whole body coil and 3D-FSPGR (TR/TE 6.6/l.3 msec, FA 30, thickness 1.3mm), and thirty patients (17 male, ages 30-80, mean age 57) underwent CEMRA at the 1.5T using Helmholtz neck coil and 3D FLASH sequence (TR/TE 3.8/l.4msec, FA 35, thickness 1mm). At both 1.5 and 3.0T, a power injector (Spectris) injected 20m1 of gadolinium to the right or left antecubital vein at a rate of 3mL/s. All CEMRA cases were accepted by one neuroradiologiest. We measured the signal intensities at the bifurcation of common carotid artery (CCA), vertebral artery (V2) and two surrounding tissues (ST) and noise at the background in all patients, and also compared contras-to-noise ratios (CNR) of CCA/ST and V2/ST at 3.0 and 1.5T
본 논문에서는 하이브리드 복호 후 전달(HDF)기법을 이용하는 2홉 무선 통신 네트워크의 BER(Bit Error Rate) 성능을 분석한다. 기존의 HDF 기법은 릴레이에서 복호된 데이터의 전달유무를 수신되는 신호 대 잡음비(SNR)를 기준으로 한다. 반면 본 논문에서는 SNR 기준 방식 대신 대수 우도비(Log Likelihood Ratio, LLR) 분석 기법을 제안한다. 제안한 새로운 HDF 기법의 근사적 BER 표현식을 유도하며, Monte-Carlo 시뮬레이션으로 검증한다. 또한 HDF 기법을 위한 최적의 임계값을 계산한다. 다양한 수식으로 인한 결론은 본 논문에서 제안하는 LLR기반 HDF가 기존의 SNR기반 HDF보다 레일리 페이딩채널과 AWGN환경에서 어떠한 임계값과 어떠한 릴레이 위치에도 뛰어난 성능을 보임을 증명한다.
To evaluation of clinical usefulness for B1+RMS limits, we compared image quality of Routine, Specific absorption rate (SAR) and Root mean square (RMS) protocol. 5 volunteers underwent Magnetic Resonance Imaging (MRI) scan of the brain using three different protocols. We draw Region of interest ROI in cortex, white matter, gray matter, putamen and thalamus of axial plan. Signal to noise ratio (SNR) were evaluated in each area and Contrast to noise ration (CNR) were evaluated between white matter and gray matter. Qualitative evaluation was used to score each ROI. B1+RMS is confirmed its usefulness compared to conventional SAR standard on the aspect of improvement of image quality, reduction of scan time and easy adjusting parameter.
목적 : 뇌백질 신호억제를 위한 중간시간 반전회복(Medium Tau Inversion Recovery, MTIR)영상에서 뇌회질과 뇌배질의 대조도를 다른 기법의 MR영상과 비교해 보고 뇌피질에 이상이 있는 환자에서 MTIR영상의 유용성을 평가하고자 하였다. 대상 및 방법 : 2명의 정상 지원자와 뇌피질 이형성증을 포함한 뇌피질 질환이 있는 21명을 대상으로 뇌회질과 뇌백질의 신호의 차이를 관심영역에서 대조도 백분율과 대조도 잡음비로 츠정하여 MTIR영상과 여러 가지 다른 MR영상을 비교하였다. 또한 시각적으로 병변이 뚜렷함, 새로운 병변의 발견여부를 시각적으로 비교 평가하였다. 결과 : MTIR영상은 다른 MR영상에 비해 대조도 백분율, 대조도 잡음비가 높아 뇌회질과 뇌백질의 신호의 차이가 가장 뚜렷하였다. 신경이주이상을 포함한 21명의 뇌피질 환자에서는 MTIR영상에서 다른 영상보다 병변이 뚜려사고 병변의 묘사(delineation)을 증가 시켰으나 새로운 병변은 발견하지 못해다. 결론 : MTIR영상은 뇌회질과 뇌백질의 대조도를 증가시키는 영상 기법이며 뇌피질을 침범한 질환을 특히 뇌피질 이형성증의 병변을 매우 잘 나타냈다. 기존의 T1강조영상 또는 3D-MPRAG에서 뇌피질-백질의 구별이 어려운 경우에는 보완적으로 이용가치가 있는 영상기법으로 생각된다.
본 논문에서는 SOFM기반 신경망 분류기를 이용한 매크로블록 기반 전송률제어 방식을 제안한다. 수학적 왜곡 비트율 모델과 귀환회기 방식을 기반으로 하는 기존의 전송률 제어 방법에 비하여, 제안된 방법은 전송비트 제어용 전역모델을 설정하고 이를 최적으로 제어할 수 있는 SOFM기반 신경망 분류기를 이용하여 영상특성 변화에 적극적인 대처를 할 수 있다. 제안된 전송률 제어 알고리즘은 기존의 MPEG-4 매크로블록 기반 전송률 제어 알고리즘에 비해 전체 연산 복잡도는 비슷하게 유지하면서 피크신호 대 잡음비의 비교에 있어서 0.2 dB ~ 0.6 dB 정도 성능이 우수함을 확인하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.