• Title/Summary/Keyword: Contrast materials

Search Result 1,577, Processing Time 0.028 seconds

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

Low Index Contrast Planar SiON Waveguides Deposited by PECVD (PECVD 법에 의해 제작된 저굴절률 차이 평판 SiON광도파로)

  • Kim, Yong-Tak;Yoon, Seok-Gyu;Yoon, Dae-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.3 s.274
    • /
    • pp.178-181
    • /
    • 2005
  • Silicon oxynitride (SiON) layers deposited upon a $SiO_2/Si$ buffer layer placed upon silicon wafers have been obtained by using PECVD from $SiH_4,\;N_2O$, and $N_2$. It can be seen that the refractive index, measured by using a prism coupler, for the SiON films can be varied between 1.4480 and 1.4958 at a wavelength of 1552 nm by changing the process parameters. Optical planar waveguides with a thickness of $6{\mu}m$ and a refractive index contrast ($\Delta$n) of $0.36\% have been deposited. Also, etching experiments were performed using ICP dry etching equipment on thick SiON films grown onto Si substrates covered by a thick $SiO_2$ buffer layer. A polarization maintaining single-mode fiber was used for the input and a microscope objective for the output at $1.55{\mu}m$. As a result, a low index contrast SiON based waveguide is fabricated with easily adjustable refractive index of core layer. It illustrates that the output intensity mode is a waveguiding single-mode.

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

Liquid Crystalline Polymer for the Alignment of Ferroelectric Liquid Crystal Display (강유전정 액정 디스플레이의 배향을 위한 액정성 고분자)

  • Jin, Sung-Ho;Jeon, Young-Jae;Lee, Jong-Chun;Kim, Gang
    • Korean Journal of Materials Research
    • /
    • v.10 no.5
    • /
    • pp.350-353
    • /
    • 2000
  • Thermotropic liquid crystalline polymer(LCP) has been used for the alignment of ferroelectric liquid crystal (FLC) molecules and the surface morphology of the resulting polymeric thin film has been observed by atomic forced microscope. The uniform alignment of FLC molecules on the surface of thermotropic LCP thin film was obtained even though microgroove structures were not formed. The contrast ratio of sample cell was about 23:1 including two polarizers and a good memory capability due to the bistability of FLC was obtained. After AC field stabilization at 20V, the typical stripe-shaped patterns appeared.

  • PDF

The Crystallization Properties of $Te_x(Sb_{85}Ge_{15})_{100-x}$ Thin films for High Contrast Ratio and Low Loss Optical Recording (고대비.저손실 광기록을 위한 $Te_x(Sb_{85}Ge_{15})_{100-x}$ 박막의 결정화 특성)

  • Kim, Jong-Ki;Kim, Hong-Seok;Lee, Hyun-Yong;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1274-1276
    • /
    • 1997
  • We have investigated the crystallization properties of $Te_x(Sb_{85}Ge_{15})_{100-x}$ (x=0.3, 0.5, 1.0 at.%) thin films as observing the reflectance change, XRD and SEM. The reflectance difference(${\Delta}R$) between amorphous and crystalline phases appears appoximately 20%, in all films, at 780nm(diode laser wavelength). In the case of $Te_{0.5}(Sb_{85}Ge_{15})_{99.5}$ thin film, especially, ${\Delta}R$ is about 30%. Also, amophous-to-crystalline phase change is observed at all films. Therefore, $Te_{0.5}(Sb_{85}Ge_{15})_{99.5}$ thin film can be evaluated as attractive optical recording material with low loss and high contrast ratio.

  • PDF

Transcaval TIPS in Patients with Failed Revision of Occluded Previous TIPS

  • Chang Kyu Seong;Yong Joo Kim;Tae Beom Shin;Hyo Yong Park;Tae Hun Kim;Duk Sik Kang
    • Korean Journal of Radiology
    • /
    • v.2 no.4
    • /
    • pp.204-209
    • /
    • 2001
  • Objective: To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Materials and Methods: Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Results: Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Conclusion: Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  • PDF

A Study on the Harmony for Contrast Coloration of Clothing and Makeup (의복과 메이크업의 콘트라스트 배색에 따른 조화감 연구)

  • Jeong, Su-Jin
    • Korean Journal of Human Ecology
    • /
    • v.16 no.3
    • /
    • pp.601-613
    • /
    • 2007
  • In this research, 128 stimuli of contrast coloration of lipstick and clothing were evaluated to the degree of harmony in the coordination of makeup and clothing color depending on the combination of eyeshadow color(brown, violet), lipstick color(red, orange, and purple), lipstick tone(vivid, light, dull, and dark), clothing style(formal, casual), and clothing tone(vivid, light, dull, and dark). Sets of stimulus and response scales were used as experimental materials. The subjects were 768 female undergraduates living in Gyeongsangnam-do. As to the brown eyeshadow, dull lipstick and light, dull clothing, vivid, dull, dark lipstick and dark clothing among the combinations of red lipstick and blue green clothing, dull lipstick and light, dull, dark clothing, dark lipstick and dull, dark clothing among the combinations of orange lipstick and purplish blue clothing were evaluated as harmonious coloration regardless of the clothing style. As to the violet eyeshadow, combinations of red lipstick and blue green clothing and combinations of red purple lipstick and yellow green clothing wide come out range of disharmony. Thus, the degree of harmony in the contrast coloration can be perceived to be different depending on how the color and tone of clothing and lipstick are coordinate.

The Effect of Color and Tone on Harmony of Contrast Coloration -Focus on Shirt and Tie of Menswear- (컨트라스트 배색조화에 영향을 미치는 색과 톤의 영향 - 남성복 셔츠와 타이를 중심으로 -)

  • Lim, Ji-Young
    • Fashion & Textile Research Journal
    • /
    • v.9 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • The purpose of this research was to investigate the effects of used color and tone on harmony perception by applying contrast coloration of shirt and necktie. This experiment designed by shirt color(red, blue, purple, green), tie color(green or blue tie with red shirt, yellow or red tie with blue shirt, yellow or green tie with purple shirt, purple or red tie with green shirt), shirt tone(vivid, light, dull, dark), tie tone(vivid, light, dull, dark), and perceiver gender(a male, a female). The experimental materials developed for this study were a set of stimulus and response scales, we harmonized those colors of shirts and neckties contrast, then made shirt and necktie tone differently. The subjects of this research were 640 male and 640 female college students. The data was analyzed by using SPS program. Shirt color, tie color, shirt tone, tie tone, perceiver gender influenced on harmony perception independently. Shirt color and tie color, shirt color and shirt tone, shirt color and perceiver gender, tie color and tie tone, tie color and perceiver gender, shirt tone and tie tone influenced on the harmony perception by interaction.

Theoretical Study for the ITO/Si based High Contrast Grating Structure with Focusing Capability and its Fabrication

  • Kim, J.Y.;Yeon, K.H.;Kyhm, J.;Cho, W.J.;Kim, T.J.;Kim, Y.D.;Song, J.D.
    • Applied Science and Convergence Technology
    • /
    • v.24 no.6
    • /
    • pp.250-253
    • /
    • 2015
  • High contrast grating (HCG) is the structure made up of the sub-wavelength grating of high-index and the surrounding layer of low-index, which reveals high contrast between two materials. Its advantages include high reflectivity over a broad bandwidth, polarization and wavelength selectivity, optical high-Q resonator, and phase modulation. In this work, the HCG structure comprising of indium tin oxide (ITO) and Silicon (Si), for the surrounding layer and the grating layer respectively, was studied. Its theoretical model was established, and transmittance, phase and optical behavior were calculated by rigorous coupled-wave analysis and finite element method. Furthermore, the established structure was fabricated to validate its feasibility. The fabricated structure shows the focusing capability whose length is about $10{\mu}m$, and the feasibility of the structure was demonstrated. It is also meaningful that ITO layer can contribute to the fabrication of the HCG structure, leading to enable the structure to be electrical-driven.

Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

  • Jongmin J. Lee;Yongmin Chang;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.91-97
    • /
    • 2000
  • Objective: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. Materials and Methods: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose timeintensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. Results: Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. Conclusion: Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

  • PDF