• Title/Summary/Keyword: Contrast examination

Search Result 466, Processing Time 0.028 seconds

Concurrent Chemoradiation with Weekly Paclitaxel and Cisplatin for Locally Advanced Cervical Cancer

  • Kalaghchi, Bita;Abdi, Robab;Amouzegar-Hashemi, Farnaz;Esmati, Ebrahim;Alikhasi, Afsaneh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.287-291
    • /
    • 2016
  • Cervical cancer is one of the most common gynecological cancers in Iranian women. This study was initiated to assess whether the combination of paclitaxel and cisplatin with radiation might feasible for these patients. The aim was to assess tumor response and toxicity of weekly cisplatin and paclitaxel along with radiotherapy in the treatment of cervical cancer. Women with primary untreated squamous cell carcinoma of the cervix with FIGO stages IB2 to IIIB were treated with weekly injections of cisplatin 30 mg/m2 and paclitaxel 35 mg/m2 for 5-6 weeks along with radiotherapy. A total of 25 patients were enrolled in this study who completed the intended treatment. Disease was assessed prior to treatment by pelvic examination and contrast enhanced MRI of the abdomen and pelvis. Response was assessed 1 month after completion of treatment by physical examination and 3 months after also by MRI.Toxicity was assessed and was graded using RTOG grading. There was a complete response rate of 84% after 3 months. The major toxicity was grade 1 and 2 anemia (92%). The mean duration of treatment was 58 days. In conclusion, combination chemotherapy with cisplatin and paclitaxel along with radiotherapy in patients with locally advanced squamous cell carcinoma of cervixwas well tolerated, in contrast to other studies, but it seems that there was no increase in tumor response and progression free survival with this treatment regimen.

Gastrotomy Approach Retrieval of Esophageal Foreign Body using Long Forceps Technique in Five Dogs (위 절개술 접근과 긴 겸자를 이용한 식도 내 이물 제거 5례)

  • Yoon, Hun-Young;Kang, Myung-Gon;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.628-631
    • /
    • 2009
  • Five dogs presented to the Veterinary Medical Teaching Hospital of the Konkuk University and Hangang Animal Hospital with a history of foreign body ingestion. On physical examination, five dogs showed lethargy, anorexia, or vomiting. Plain radiographs revealed that radiopaque foreign bodies lodged in the heart base or caudal thoracic esophagus. Positive contrast esophagogram revealed that large foreign bodies severely expanded the esophagus and there was no evidence of leakage of the contrast agent from the esophagus into the thoracic cavity. Gastrotomy for retrieval of esophageal foreign bodies using long forceps technique was performed. Esophageal foreign bodies were successfully retrieved in all dogs. The follow-ups were completed 10 days to 2 years after surgery. The follow-up information was based on physical examination by veterinarians and telephone interview with owners. The owners reported that there was no evidence of complications related to surgery such as vomiting, regurgitation, dysphagia, gagging, hyper-salivation, or anorexia in all dogs.

Evaluation of black glutinous rice (Oryza sativa L) extract as a novel nuclear stain for human sperm head assessment by microscopic examination

  • Chomean, Sirinart;Sukanto, Tanawan;Piemsup, Arreya;Chaiya, Jirattikan;Saenguthai, Kolunya;Kaset, Chollanot
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.46 no.2
    • /
    • pp.60-66
    • /
    • 2019
  • Objective: To compare black rice (Oryza sativa L) extract with three different staining methods for human sperm head assessment. Methods: Semen samples were collected from 34 volunteers. Four smears of each ejaculate were prepared for staining using the rapid Papanicolaou (PAP) stain, SpermBlue, DipQuick, and black rice extract. The percentage of defective sperm heads (mean${\pm}$standard deviation) was compared. Results: Black glutinous rice extract, a natural dye, was used instead of hematoxylin to stain the nuclei of the sperm heads. The percentage of defective sperm heads showed a significant difference between black rice extract and DipQuick (p= 0.000). In contrast, black rice extract and rapid PAP showed no statistically significant difference (p= 0.974). A strong correlation (r = 0.761) was found between the findings obtained using rapid PAP and black rice extract. In contrast, a weak correlation (r = 0.248) was obtained between DipQuick and black rice extract for the percentage of defective sperm heads. Conclusion: The results showed good agreement and a strong correlation between the rapid PAP and black rice extract stains. The advantages of black rice extract as a novel substitute for hematoxylin for nuclear staining include ease of preparation, local availability, and favorable nuclear staining properties. Further studies could also focus on comparing staining techniques in clinical samples.

Preliminary study of presumptive intradural-intramedullary intervertebral disc extrusion in 20 dogs

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Background: Intradural-intramedullary intervertebral disc extrusion (IIVDE) is a rare condition of intervertebral disc disease. However, the diagnosis of IIVDE is challenging because the prognosis and imaging characteristics are poorly characterized. Objectives: We aimed to describe the clinical and imaging characteristics of tentatively diagnosed IIVDE in dogs to assess the prognostic utility of neurological grade and magnetic resonance imaging (MRI) findings. Methods: Twenty dogs were included in this retrospective cohort study. Results: Nonchondrodystrophic breeds (n = 16) were more predisposed than chondrodystrophic breeds. Most dogs showed acute onset of clinical signs. Neurological examination at admission showed predominant non-ambulatory paraparesis (n = 9); paresis (n = 16) was confirmed more frequently than paralysis (n = 4). Follow-up neurological examination results were only available for 11 dogs, ten of whom showed neurological improvement and 8 showed successful outcomes at 1 month. The characteristic MRI findings include thoracic vertebra (T)2 hyperintense, T1 hypointense, intramedullary linear tracts with reduced disc volume, and cleft of the annulus fibrosus. None of the MRI measurements were significantly correlated with neurological grade at admission. Neurological grade did not differ according to the presence of parenchymal hemorrhage, parenchymal contrast enhancement, and meningeal contrast enhancement. Neurological grades at admission showed a statistical correlation with those observed at the 1-month follow-up (r = 0.814, p = 0.02). Conclusions: IIVDE is a rare form of disc extrusion commonly experienced after physical activity or trauma and most frequently affects the cranial-cervical and thoracolumbar regions of nonchondrodystrophic dog breeds. Neurological score at admission emerged as a more useful prognostic indicator than MRI findings in dogs with suspected IIVDE.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

Consideration of Adverse Reaction to MDCT Contrast Media (MDCT에 사용되는 조영제의 부작용에 대한 고찰)

  • Yang, Won-Seok;Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.51-57
    • /
    • 2012
  • In this experiment, we investigated 82 patients who suffered adverse reactions due to contrast medium. We selected the subjects out of 21,178 people who had an intravenous injection of contrast medium to undergo MDCT examination at one university hospital in Busan in 2007. As a result, the largest groups of the patients were as follows. 52.4% of the patients were male when classify by gender; 28.0% of the patients were 50's by age; 45% of the patients got when it was spring(April and March); 75.6% of the patients had a side effects when the speed of injection is 2.5mL/sec; 58.5% of the patients were suffered when the volume of injected contrast medium is over 130mL. Urticaria was the main symptom of side effect as 26.8%. And the main treatment for the effect was alleviating the symptoms before making patients to return home. Thus, practical preventive measures are needed as follows : use the OCS system to observe warning signs at risky patients, secure warming spaces for patients to cope with season changing, prepare enough emergency kits for the patients in danger, and establish CPR call systems, explain the risk of contrast medium and get agree about using contrast medium.

Image Measurement on Influence from Application of Compression Band on Intravenous Urography for Urolithiasis Patient (요로결석 환자의 경정맥 요로조영 검사 시 압박 유무에 따른 영상평가)

  • Kim, Hyeong-Gyun;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.261-266
    • /
    • 2015
  • Intravenous urography (IVU) for urolithiasis is a radiologic examination to diagnosis stone in the ureter path using iodine contrast media, which is radioopacity material. The method includes compression on the upper iliac crest. The compression band prevents outlet of the contrast media through the bladder and enables easier movement to upper urinary tract. This usage depends on the policy of a hospital. Therefore, this study aimed to review and compare the characteristic of progress of contrast media either in compression and non-compression. The retrospective image measurement on 60 cases of intravenous pyelography was conducted at a hospital with the identical type and amount of contrast media as well as criteria for testing. Image measurement was limited to 5 minutes clip, which is optimal for progress of contrast media depending on usage of the compression band. Also, anatomical regions were set as following: "RP" is from renal pyramid to renal pelvis, "PL" is from renal pelvis to lumbar three endplate, and "IU" and "IL" for upper and lower parts from both iliac crests. Analysis has been conducted through the statistical method based on Fisher's Exact Test to find if there are differences of distribution with the anatomical regions with compression or no compression. It has been confirmed that there is no statistical significant difference as the video measurement on 30 cases of compression and non-compression group respectively resulted in P value of 0.580 from left and 0.711 from right (both 0.960). Therefore, it has been concluded that application of a compression band on an intravenous pyelography for urolithiasis patient does not meaningfully affect the progress of contrast media.

Development and Implementation of a Critical Pathway for Prevention of Adverse Reactions to Contrast Media for Computed Tomography (CT 조영제의 부작용 예방을 위한 표준진료지침서의 개발과 적용)

  • Jang, Keun-Jo;Kim, Myeong-Goo;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • The purpose of this study is to develop a critical pathway (CP) for the prevention of adverse reactions to contrast media for computed tomography. The CP was developed and implemented by a multidisciplinary group in Seoul National University Hospital. The CP was applied to CT patients. Patients who underwent CT scanning were included in the CP group from March in 2004. The satisfaction of the patients with CP was compared with non-CP groups. We also investigated the degree of satisfaction among the radiological technologists and nurses. The degree of patient satisfaction with the care process increased patient information(24%), prevention of adverse reactions to contrast media(19%), pre-cognitive effect of adverse reactions to contrast media(39%) and information degree of adverse reactions to contrast media(19%). This CP program can be used as one of the patient care tools for reducing the adverse reactions to contrast media and increasing the efficiency of care process in CT examination settings.

  • PDF

Study on the Contrast Media Volume according to Scan Time during Brain Angiography Examination (Brain Angiography 검사 시 Scan Time에 따른 Contrast Media Volume에 대한 연구)

  • Lee, Ju Ryeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.29-35
    • /
    • 2021
  • The purpose of this study was to investigate whether there is a difference in image quality before and after reducing the amount of contrast medium in cerebral hemorrhagic patients who periodically follow up CT, and after reducing the amount of contrast medium, the image before and after reduction was examined, and the image quality was assessed by setting ROI at each vessel location using MMWP program. First Rt. CCA, Lt.CCA. Rt.MCA, Lt.MCA and Basilar Artery each got an ROI. Second, the mean and standard deviation values for the ROI were obtained. Third, SNR and CNR were obtained through the average and standard deviation values obtained. T-test statistics show that the SNR and CNR values obtained show that the result values for SNR are Rt.CCA 0.765, Ltd.CCA 0.871, Rt.MCA 0.343 LT.MCA 0.235, Basilar alternative 0.916, result value for CNR Rt.CCA 0.088, Ltd.CCA 0.069, Rt.MCA 0.818, Let's...MCA 0.579 and Basilar Artery 0.878. The results obtained through the obtained SNR and CNR values showed no difference in the quality of the images before and after reducing contrast medium. Therefore, we hope that this study will be an indicator that reduces the burden on contrast agents on patients who do CT examinations periodically.