• Title/Summary/Keyword: Contrast agent

Search Result 361, Processing Time 0.037 seconds

The increase of blood vessels using a signal during the image acquisition phase T1 shortening effect (위상영상 획득 시 T1 shortening effect를 이용한 혈관의 신호 증가에 관한 연구)

  • Lee, Ho-Beom;Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4704-4710
    • /
    • 2015
  • The purpose of this study is to obtain a useful diagnostic image by increasing the signal strength of the peripheral artery, was to use a T1 shortening effect of gadolinium contrast agents to improve the disadvantages of the phase image. From october to december 2014 thirty patients were underwent the MRI scanning, except for heart disease. Research method was evaluated comparing the image after gadolinium contrast MR image acquisition step before evaluating the difference between the signal intensity for T1 shortening effect. In frontal lobe 19.45%, temporal lobe 23.09%, occipital lobe 25.45%, parietal lobe 18.82%, cerebellum 20.93% after peripheral arterial signal strength results of gadolinium contrast agent injection was increased significantly after injection of gadolinium both statistically significant. After injecting a contrast agent gadolinium in SWI by increasing the signal strength of the T1 shortening effect can be obtained when using the phase image to give a useful image in diagnosis and treatment.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

Principles and Technical Aspects of Perfusion Magnetic Resonance Imaging (관류 자기공명영상의 원리 및 기술)

  • Jahng, Geon-Ho;Kim, Ho-Sung;Kim, Sun-Mi;Ryu, Chang-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.91-101
    • /
    • 2011
  • Perfusion magnetic resonance imaging (pMRI) is a special technique for evaluation of blood flow. Exogenous pMRI methods which are dynamic susceptibility contrast (DSC) and dynamic contrast-enhanced (DCE) use an intravenous bolus injection of paramagnetic contrast agent. In contrast, an endogenous pMRM method which is arterial spin labeling (ASL) use diffusible blood in body. In order to scan pMRI in human, technical optimizations are very important according to disease conditions. For examples, DSC is popularly used in patients with acute stroke due to its short scan time, while DSC or DCE provides the various perfusion indices for patients with tumor. ASL is useful for children, women who are expected to be pregnant, and in patients with kidney diseases which are problematic in nephrogenic systemic fibrosis (NSF). Perfusion MRI does not require any injection of radioisotopes. We expect that demand for perfusion MRI will be higher in evaluating drug efficacy and other treatment effects.

Comparison of Multilevel with Single Level Injection during Lumbar Sympathetic Ganglion Block: Efficacy of Sympatholysis and Incidence of Psoas Muscle Injection

  • Hong, Ji-Hee;Oh, Min-Ju
    • The Korean Journal of Pain
    • /
    • v.23 no.2
    • /
    • pp.131-136
    • /
    • 2010
  • Background: We prospectively evaluated the incidence and possible factors causing intramuscular injection during lumbar sympathetic ganglion block and compared the multiple needle technique to the single technique to obtain a profound and complete block effect. Methods: Among 83 patients, 58 patients (group A, n = 27, multiple needle technique and group B, n = 31, single needle technique) were reevaluated for the changes of skin temperature (Ts) and mean segment of longitudinal contrast spread. After injecting the contrast agent, the incidence of psoas muscle injection and the change of Ts was compared between two groups. Results: The incidence of psoas muscle injection was 21.3% (46/216) and it was associated with the level of injection (L2) significantly (${\chi}_2$ = 14.773, P = 0.001). $DT^{post}$ (postblock temperature difference between ipsilateral and contralateral great toe, $4.6{\pm}2.8^{\circ}C$, $1.8{\pm}1.6^{\circ}C$, P < 0.001 for group A and B) and $DT^{net}$ ($DT^{post}$ - $DT^{pre}$, $3.9{\pm}2.7^{\circ}C$, $1.5{\pm}1.5^{\circ}C$, P < 0.001 for group A and B) was significantly higher in group A. The mean segment of longitudinal contrast spread was $8.1{\pm}0.9$ for group A and $3.2{\pm}1.6$ for group B (P < 0.001). Conclusions: The LSGB at the L2 level showed the lowest incidence of psoas muscle injection of contrast. Multiple needle approach showed more significant increase of $DT^{net}$ and $DT^{post}$.

Polymeric nanoparticles as dual-imaging probes for cancer management

  • Menon, Jyothi U.;Jadeja, Parth;Tambe, Pranjali;Thakore, Dheeraj;Zhang, Shanrong;Takahashi, Masaya;Xie, Zhiwei;Yang, Jian;Nguyen, Kytai T.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.3
    • /
    • pp.129-140
    • /
    • 2016
  • This article reports the development of biodegradable photoluminescent polymer (BPLP)-based nanoparticles (NPs) incorporating either magnetic nanoparticles (BPLP-MNPs) or gadopentate dimeglumine (BPLP-Gd NPs), for cancer diagnosis and treatment. The aim of the study is to compare these nanoparticles in terms of their surface properties, fluorescence intensities, MR imaging capabilities, and in vitro characteristics to choose the most promising dual-imaging nanoprobe. Results indicate that BPLP-MNPs and BPLP-Gd NPs had a size of $195{\pm}43nm$ and $161{\pm}55nm$, respectively and showed good stability in DI water and 10% serum for 5 days. BPLP-Gd NPs showed similar fluorescence as the original BPLP materials under UV light, whereas BPLP-MNPs showed comparatively less fluorescence. VSM and MRI confirmed that the NPs retained their magnetic properties following encapsulation within BPLP. Further, in vitro studies using HPV-7 immortalized prostate epithelial cells and human dermal fibroblasts (HDFs) showed > 70% cell viability up to $100{\mu}g/ml$ NP concentration. Dose-dependent uptake of both types of NPs by PC3 and LNCaP prostate cancer cells was also observed. Thus, our results indicate that BPLP-Gd NPs would be more appropriate for use as a dual-imaging probe as the contrast agent does not mask the fluorescence of the polymer. Future studies would involve in vivo imaging following administration of BPLP-Gd NPs for biomedical applications including cancer detection.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

Radiation Shielding to Minimize Image Information Loss (영상 정보 손실을 최소화하는 방사선 차폐체 연구)

  • Su-han Jang;Sang-Hyeun Park;Myeong-Sik Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.449-457
    • /
    • 2023
  • Shielding for reducing exposure dose can make the diagnosis limited. The purpose of this study is to increase the efficiency of radiation protection and minimize the loss of image information by producing the shielding made of the water and the contrast medium which has different proportion and finding out the ideal proportion of them. Each shielding materials were made of water and water-soluble iodine contrast medium with the different proportion. The attenuation rate of absorbed dose was evaluated by the shielding materials in the plastic contents for measuring the efficiency of the radiation protection. As a result, the higher ratio of the contrast medium, the more efficient it is for radiation attenuation. The anatomical structure was observed most properly in case of the solution with 20 ml of the contrast medium and most difficultly in case of more than 60 ml of the contrast medium. In case of the signal intensity between skeleton and gas, the difference of average value had a significant as p < 0.001. Shielding with contrast medium attenuates less than the conventional shielding but in the examination for the sensitive part to radiation, it can be used to minimize the loss of the image information and reduce the exposure dose.

A Recommender Agent using Association Item Trees (연관 아이템 트리를 이용한 추천 에이전트)

  • Ko, Su-Jeong
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.4
    • /
    • pp.298-305
    • /
    • 2009
  • In contrast to content_based filtering systems, collaborative filtering systems not only don't contain information of items, they can not recommend items when users don't provide the information of their interests. In this paper, we propose the recommender agent using association item tree to solve the shortcomings of collaborative filtering systems. Firstly, the proposed method clusters users into groups using vector space model and K-means algorithm and selects group typical rating values. Secondly, the degree of associations between items is extracted from computing mutual information between items and an associative item tree is generated by group. Finally, the method recommends items to an active user by using a group typical rating value and an association item tree. The recommender agent recommends items by combining user information with item information. In addition, it can accurately recommend items to an active user, whose information is insufficient at first rate, by using an association item tree based on mutual information for the similarity between items. The proposed method is compared with previous methods on the data set of MovieLens recommender system.

Persulfate Oxidation of 2,4-D: Effect of Hydroxylamine and Chelating Agent (과황산을 이용한 2,4-D의 산화: 하이드록실아민, 킬레이트제의 영향)

  • Choi, Jiyeon;Yoon, Na Kyeong;Shin, Won Sik
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.54-64
    • /
    • 2021
  • The chemical warfare agents (CWAs) have been developed for offensive or defensive purposes and used as chemical weapons in war and terrorism. The CWAs are exposed to the natural environment, transported through the water system and then eventually contaminate soil and groundwater. Therefore, effective decontamination technology to remediate CWAs are needed. The CWAs are extremely dangerous and prodution is strictly prohibited, therefore, it is difficult to use CWAs even in experimental purpose. In this study, 2,4-dichlorophenoxyacetic acid (2,4-D) was chosen as a model representative CWA because it is a simulant of anti-plant CWAs and one of the major component of agent orange. The optimum degradation conditions such as oxidant:activator ratio were determined. The effects of hydroxylamine and chelating agents such as citric acid (CA), oxalic acid (OA), malic acid (MA), and EDTA addition to increase Fe2+ activation were also investigated. Scavenger experiments using tert-butyl alcohol (TBA) and ethanol confirmed that although both sulfate (SO4•-) and hydroxyl radical (•OH) existed in Fe2+-persulfate system, sulfate radical was the predominant radical. To promote the Fe2+ activator effect, the effect of hydroxylamine as a reducing agent was investigated. In chelating agents assisted Fe2+-persulfate oxidation, the addition of 2 mM of CA and MA enhanced 2,4-D degradation. In contrast, EDTA and OA inhibited the 2,4-D removal due to steric hindrance effect.

Blood Vessel Enhancement by Directed Diffusion

  • Intajag, S.;Tipsuwanporn, V.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.101-106
    • /
    • 2004
  • In this paper, a blood vessel in an angiographic image, which plays an importance role in the diagnose diseases including in the eyes, brain and heart, is enhanced by using a directed diffusion technique. A fundamental component of the angiographic analysis is vessel segmentation that the proposed method provides a preprocessing of the image into a form suitable for human analysis, or more importantly, for machine analysis such the segmentation. Vessel enhancement is a challenging problem due to the complex nature of vascular trees and to imaging imperfections. Some parts of the inherent imperfections in angiography are the intensity inhomogeneity between the larger and smaller vessels, and another imperfection is the leakage of contrast agent into the background tissue that provides to low contrast between vessels and tissue. In the proposed scheme, the directed diffusion solves the problem by formulating a local geometric structure, which consists of direction and scale of the blood vessels. The diffusion process uses the local structure to enhance by a diffusivity tensor. The proposed algorithm can be applied to maintain sharpness and coherence-smooth the intra-regions into homogeneity better than traditional diffusion methods, which are Gaussian regulation and coherence enhancing diffusion.

  • PDF