• 제목/요약/키워드: Contrast Agents

검색결과 271건 처리시간 0.028초

뇌 혈관검사 시 적정 조영제량에 관한 연구 (A Study on the Optimum Amount of Contrast Media in Brain Angiography)

  • 김규형;이상호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

자기공명영상검사용 가돌리늄 경정맥 조영제의 급성 부작용: 부작용 전산 체계를 이용한 후향적 분석 (Acute Adverse Reactions to Gadolinium-based Intravenous Contrast Agents for MRI : Retrospective Analysis Using Computed Reporting System)

  • 최문형;최준일;정승은;안국진;이해규
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권2호
    • /
    • pp.139-145
    • /
    • 2011
  • 목적 : 단일기관에서 발생한 가돌리니움 기반의 자기공명영상 경정맥 조영제의 급성 부작용의 빈도 및 종류, 조영제 별 차이를 알아보았다. 대상 및 방법 : 병원정보시스템의 부작용 보고체계를 분석하여, 2008년 10월부터 2010년 12월 사이에 증례를 검색하였다. 부작용은 경증, 중등도, 중증으로 분류되었고 서로 다른 조영제간에 빈도의 차이가 있는지를 분석하였다. 결과 : 총 33,600건의 조영제가 투여되었고, Gd-BT-DO3A 20,824건 (62%), Gd-DTPA 10,417건 (31%), Gd-EOB-DTPA 2,359건 (7%)이었다. 부작용은 총 39예가 발생하여 빈도는 0.1161%였고, Gd-BT-DO3A 0.1248% (26/39,67%), Gd-DTPA 0.0768% (8/39, 21%), Gd-EOB-DTPA 0.2120% (5/39,13%) 였으며, 조영제 간에 유의한 차이는 없었다. 대부분 (89.7%) 이 경증 부작용이었으며 중등도 및 중증 부작용은 각각 2명에서 발생하였다. 결론 : 한국인에서의 자기공명영상 검사용 경정맥 조영제에 의한 부작용의 빈도는 드물었으며, 특히 중등도 혹은 중증 부작용은 매우 드물었다. 세가지 조영제 사이에 부작용 발생 빈도는 차이는 없었다.

가돌리늄 조영제 주입에 따른 1H-MRS spectrum의 정량적 비교 (Quantitative Comparison of 1H-MRS Spectra Depending on the Paramagnetic Gadolinium Contrast Agent(GBCA) Injection)

  • 최관우;손순룡;유병규
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.589-595
    • /
    • 2017
  • 본 연구는 1H-MRS 검사 시 조영제 사용이 대사물질의 spectrum에 어떤 영향을 미치는지 비교 분석함으로써, 조영제 주입 후 MRS 시행의 가능성을 알아보고자 하였다. 연구방법은 2017년 1월부터 동년 5월까지 뇌 MRI 검사를 시행한 30명을 대상으로, 조영제 주입 전, 후 전두엽 백질 부분의 spectrum을 획득하여 뇌 조직의 대사물질 spectrum을 비교평가 하였다. 연구결과, 조영제를 주입할 경우 각 대사물질의 spectrum은 통계적으로 의미가 없어 조영제 사용이 대사물질의 spectrum에 영향을 미치지 않음을 알 수 있었다. 결론적으로 대조도가 떨어져 병변의 위치파악이 힘든 경우 정확한 위치의 spectrum을 얻기 위해선 조영제를 사용하여 대조도를 높인 다음 MRS를 시행하는 것이 바람직 할 것으로 사료된다.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정 (Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.27-33
    • /
    • 2000
  • 목적: 전자상자성 공명(Electron Paramagnetic Resonance EPR)을 사용하여, 현재 상용되고 있는 세가지 상자성 자기공명 조영제, Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA의 전자스핀 이완시간 $T_{le}$를 결정하고자 한다. 대상 및 방법: 본 연구에 사용된 상자성 자기공명 조영제는 Gd-DTPA(Magnevist), Gd-DTPA-BMA(OMNISCAN), Gd-DOTA(Dotarem)이다. 이들 자기공명 조영제들은 2:1 부피 비율의 메탄올과 물의 혼합용액에 희석하여 저온의 glassy상태에서 EPR스펙트럼을 얻었으며, 또한 주어진 영 자기장 갈라지기 (zero-field splitting, ZFS)변수를 $3{\times}3$ 텐서량으로 계산하는 컴퓨터 시뮬레이션 프로그램 'GEN'을 사용하여, 이들 조영제들에 대한 각각 다른 ZFS변수를 가지는 시뮬레이션 스펙트럼을 만들었다. 이 결과들과 McLachlan의 평균이완율 이론을 적용하여 전자스핀 이완시간이 결정되었다. 결과: 상자성 자기공명 조영제 Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA의 전자 횡축 스핀이완시간($T_{2e}$)은 각각 0.113ns, 0.147ns, 1.81ns, g-value는 1,9737, 1.9735, 1.9830, 전자스핀 이완시간($T_{le}$)는 18.70ns, 33.40ns, $1.66{\mu}s$로 결정되었다. 결론: 실험 결과로부터 상자성 자기공명 조영제의 ZFS변수가 클수록 짧은 전자스핀 이완시간 $T_{le}$를 가진다는 일반적인 사실을 재 확인할 수 있었다. 본 연구에 사용된 3가지 자기 공명 조영제들 중에는 화학적으로 환상구조 배위자를 갖는 Gd-DOTA가 가장 긴 전자스핀 이완시간 $T_{le}$를 가지는 것으로 나타나서 일반적으로 환상구조 배위자를 갖는 조영제들이 선상구조 배위자를 갖는 조영제에 비해 전자적인 성질은 우수한 것으로 나타났고 결론적으로 상자성 조명제가 물분자의 자기이완시간에 미치는 영향을 평가하고 고효율 상자성 자기 공명 조영제 개발에는 정확한 ZFS변수 결정이 매우 중요하다는 것을 알 수 있었다.

  • PDF

Primary Radiation Force to Ultrasound Contrast Agents in Propagating and Standing Acoustic Field

  • Seo, Jong-Bum
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권1E호
    • /
    • pp.1-8
    • /
    • 2009
  • Primary radiation force on ultrasound contrast agents (UCA) in a propagating and standing acoustic field was explored. A specific ultrasound contrast agent $Albunex^{(R)}$ and $Optison^{(R)}$ were chosen for simulation. The model was developed based on a shelled bubble model proposed by Church. The numerical simulation suggests that bubble translational motion is more significant in therapeutic ultrasound due to higher intensity and long pulse duration. Even a single cycle of a propagating wave of 4 MPa at 1 MHz can cause a bubble translational motion of greater than $1{\mu}m$ which is approximately one tenth of capillary. Hence, UCA characteristics can be significantly changed in therapeutic ultrasound without rapid bubble collapses.

Breast Ultrasound Microvascular Imaging and Radiogenomics

  • Ah Young Park;Bo Kyoung Seo;Mi-Ryung Han
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.677-687
    • /
    • 2021
  • Microvascular ultrasound (US) techniques are advanced Doppler techniques that provide high sensitivity and spatial resolution for detailed visualization of low-flow vessels. Microvascular US imaging can be applied to breast lesion evaluation with or without US contrast agents. Microvascular US imaging without a contrast agent uses a sophisticated wall filtering system to selectively obtain low-flow Doppler signals from overlapped artifacts. Microvascular US imaging with second-generation contrast agents amplifies flow signals and makes them last longer, which facilitates hemodynamic evaluation of breast lesions. In this review article, we will introduce various microvascular US techniques, explain their clinical applications in breast cancer diagnosis and radiologic-histopathologic correlation, and provide a summary of a recent radiogenomic study using microvascular US.

조영증강 초음파영상에서 밀도변화 데이터를 이용한 진단 파라미터 추출 기법 (Medical Parameter Extraction Using Time-Density Data in Contrast-Enhanced Ultrasound Image Sequence)

  • 이준용;정중은;김호준
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제4권7호
    • /
    • pp.297-300
    • /
    • 2015
  • 의료 진단 초음파영상에서 조영제의 전이시간과 확산패턴의 형태는 질환 및 병변을 분석하는 중요한 파라미터로 고려된다. 조영증강 초음파영상 분석과 관련한 기존의 대부분의 연구에서 대상 영역의 평균 명도 변화곡선을 기반으로 파라미터값을 추출한다. 그런데 이러한 명도 데이터는 조영제의 마이크로 버블 효과로 인하여 그 값이 왜곡될 수 있다. 이에 본 논문에서는 조영증강 초음파 진단 파라미터의 추출 과정에서 그 정확도를 개선하기 위하여 명도값의 변화뿐만 아니라, 조영제의 영향을 반영하는 픽셀에 대한 밀도 정보를 보완적으로 활용하는 방법을 제안한다. 제안된 기법은 간 질환 진단 과정에서 병변의 윤곽선 추출과 병변의 특성분석을 위하여 조영제의 확산시점과 속도를 보다 정확하게 판별할 수 있게 한다. 실제 임상 데이터를 사용한 실험결과를 통하여, 제안된 방법이 파라미터 영상 생성기법에서 개선된 결과를 생성할 수 있음을 보인다.

조영제를 사용하는 환자의 부작용: 특성과 관리에 관한 연구 (Studies of the side effects on using the contrast media: It's characteristic and management)

  • 선종률;유세종
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.427-431
    • /
    • 2014
  • The purpose of this study is to monitor the current adverse reactions in administering CT contrast agents at general hospitals and also to suggest the practical guidelines to minimize the risk and to show the successful patient management. At four Dajeon city general hospitals, the contrast agents were administered in 646,828 cases and the overall prevalence of adverse reactions was 4,110 cases from January 2010 to December 2013. However, we excluded the two hospitals' 3,658 cases because the patients' data was inadequate. Consequently, the case surveys on the rest of 452 cases have been studied and submitted. After comparing the patients with a control group, we evaluated that the key factors of the adverse reactions were the gender and age difference of the patients, the examination period, the examination method, the quantity and administrating speed of the contrast agents. Even though the four general hospitals have their own management systems on adverse reactions, but their systems were not satisfying. To improve the quality of the management systems and to investigate further cases, some hospital administration procedures on the subject should be systemized and general hospitals should follow the recommended procedures. Moreover, the existing three-year-term evaluation should not only judge the adverse reaction management but also conclude some details on the sub criteria of the evaluation. The details on the sub criteria include the contrast agent characters, the quantity and administrating speed of the drug, the incidents' occurred time, an anamnesis; a case history, the medical history of the patients and the reaction occurring body parts, and the examination title. The details of the medical examiners are also added to the sub criteria.

초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석 (Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis)

  • 이학종;윤태종;윤영일
    • Ultrasonography
    • /
    • 제32권1호
    • /
    • pp.59-65
    • /
    • 2013
  • 목적: 본 연구는 초음파 조영제를 직접 합성하고 그 크기 및 소멸 시간 등의 특성을 분석하며, 기존의 초음파 조영제와의 영상을 비교하여 앞으로 초음파 조영제를 매개로 한 영상 유도 하 약물 및 유전자 치료제의 전달 시스템 구축의 기본을 갖추고자 한다. 대상 및 방법: 초음파 조영제는 21마이크로 몰의 DPPC(1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), 9 마이크로 몰의 콜레스테롤, 1.9 마이크로 몰의 DCP(Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$) 및 클로로포름 및 SF6 기체를 이용하여 합성하였다. 약 12-24시간의 동결건조 후에 초음파 조영제는 SF6 기체와 초음파 처리(sonication) 법을 이용하여 합성하였고 그 초음파 조영제의 크기는 압출기를 이용하여 일정한 크기로 조정하였다. 합성된 초음파 조영제는 동적 광산란 측정법(dynamic light scattering measurement)을 이용하여 그 크기를 분석하였다. 한편 합성한 초음파 조영제의 소멸 양상을 평가하기 위하여 광학 현미경을 이용하여 그 숫자를 합성 직후, 12시간, 24시간, 36시간, 48시간, 60시간, 72시간 및 84시간 후에 평가하였다. 초음파 조영제로서의 효과를 평가하기 위하여 모형을 만들어 현재 임상적으로 사용되고 있는 초음파 조영제와 그 에코를 비교 분석하였다. 결과: 초음파 조영제는 동결건조-초음파 처리 방법을 통하여 성공적으로 합성 할 수 있었다. 합성된 초음파 조영제는 154.2 nm의 정점 (peak)에서 가장 많이 분포하였으며 합성 후 24시간부터는 입자의 숫자들이 감소하는 양상을 보였다. 소노뷰와 합성된 초음파 조영제의 에코밝기는 유의한 차이를 보이지 않았으나 소노뷰와 생리식염수 및 합성된 초음파 조영제와 생리식염수의 에코 밝기는 통계적으로 유의한 차이를 보였다 (p < 0.01). 결론: 본 연구를 통하여 초음파 조영제를 직접 합성할 수 있는 방법을 습득할 수 있었고 그 크기 및 특성을 분석할 수 있었다.