• Title/Summary/Keyword: Contraction stress

Search Result 200, Processing Time 0.031 seconds

Numerical Formulation of Thermo-Hydro-Mechanical Interface Element (열-수리-역학 거동 해석을 위한 경계면 요소의 수식화)

  • Shin, Hosung;Yoon, Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.9
    • /
    • pp.45-52
    • /
    • 2022
  • Because discontinuity in the rock mass and contact of soil-structure interaction exhibits coupled thermal-hydromechanical (THM) behavior, it is necessary to develop an interface element based on the full governing equations. In this study, we derive force equilibrium, fluid continuity, and energy equilibrium equations for the interface element. Additionally, we present a stiffness matrix of the elastoplastic mechanical model for the interface element. The developed interface element uses six nodes for displacement and four nodes for water pressure and temperature in a two-dimensional analysis. The fully coupled THM analysis for fluid injection into a fault can model the complicated evolution of injection pressure due to decreasing effective stress in the fault and thermal contraction of the surrounding rock mass. However, the result of hydromechanical analysis ignoring thermal phenomena overestimates hydromechanical variables.

Development and growth of the human fetal sacroiliac joint revisited: a comparison with the temporomandibular joint

  • Ji Hyun Kim;Zhe-Wu Jin;Shogo Hayashi;Gen Murakami;Hiroshi Abe;Jose Francisco Rodriguez-Vazquez
    • Anatomy and Cell Biology
    • /
    • v.56 no.2
    • /
    • pp.252-258
    • /
    • 2023
  • The human fetal sacroiliac joint (SIJ) is characterized by unequal development of the paired bones and delayed cavitation. Thus, during the long in utero period, the bony ilium becomes adjacent to the cartilaginous sacrum. This morphology may be analogous to that of the temporomandibular joint (TMJ). We examined horizontal histological sections of 24 fetuses at 10-30 weeks and compared the timing and sequences of joint cartilage development, cavitation, and ossification of the ilium. We also examined histological sections of the TMJ and humeroradial joint, because these also contain a disk or disk-like structure. In the ilium, endochondral ossification started in the anterior side of the SIJ, extended posteriorly and reached the joint at 12 weeks GA, and then extended over the joint at 15 weeks GA. Likewise, the joint cartilage appeared at the anterior end of the future SIJ at 12 weeks GA, and extended along the bony ilium posteriorly to cover the entire SIJ at 26 weeks GA. The cavitation started at 15 weeks GA. Therefore, joint cartilage development seemed to follow the ossification of the ilium by extending along the SIJ, and cavitation then occurred. This sequence "ossification, followed by joint cartilage formation, and then cavitation" did not occur in the TMJ or humeroradial joint. The TMJ had a periosteum-like membrane that covered the joint surface, but the humeroradial joint did not. After muscle contraction starts, it is likely that the mechanical stress from the bony ilium induces development of joint cartilage.

A Discussion on Three Different Issues Between Huangdi Neijing 黃帝內經 and Yixuexinwu 醫學心悟 Regarding the 19 Mechanisms of Disease (病機十九條) (병기(病機)19조(條)에 관하여 ≪의학심오(醫學心悟)≫가 ≪황제내경(黃帝內經)≫과 다른 세 가지 논점(論點)에 관한 고찰(考察))

  • Chan-yong Jeon
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.6
    • /
    • pp.1271-1278
    • /
    • 2023
  • Objective: The 19 Mechanisms of Disease were first described in Huangdi Neijing. When examining Yixuexinwu, three descriptions that were different from Huangdi Neijing were found. Methods and Results: After examining the two books, three differences in the description of the 19 Mechanisms of Disease were discovered: 1) The upper and lower locations of dyspnea (喘症) are reversed. 2) The ratio of provisions for "fire (火)" and "cold (寒)" is different. 3) The organ affiliation for pain is different. Conclusion: 1) The upper and lower locations of dyspnea (喘症) are reversed. : Regarding external contraction dyspnea (外感喘), Yixuexinwu used the disease of the upper location (lung 上, 肺) in the same way as in Huangdi Neijing. In terms of internal damage (內傷喘), it was separately classified as a disease of the lower location (kidney 下, 腎). 2) The ratio of provisions for "fire (火)" and "cold (寒)" is different. : Arithmetically, if you round off the number after calculating the fraction, the difference between the two ratios becomes the same. Theoretically, five provisions of "fire" are replaced by four provisions of "heat (熱)", and the difference in ratios is exactly the same. Empirically, it emphasizes that there are more illnesses from fire and heat than from cold. 3) The organ affiliation for pain is different. : Huangdi Neijing described general inflammatory pain, while the Yixuexinwu described only stress-related abdominal pain (肝木乘脾 腹痛).

Scintigraphic Assessment of Myocardial Viability (신티그라피에 의한 심근생존능 평가)

  • Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.155-160
    • /
    • 1993
  • The identification of viable myocardium in patients with coronary artery disease and left ventricular dysfunction is an issue of increasing clinical relavance in the current era of myocardial revascularization. There are at least two forms of reversible myocardial dysfunction. Early reperfusion does not always lead to immediate functional improvement; rather, the return of contractility in tissue salvaged by reperfusion is delayed for hours, days or even weeks, a phenomenon that has been termed "stunned myocardium". Some patients with coronary artery disease show myocardial dysfunction at rest which are associated with reduced perfusion, and which disappear after revascularization; this phenomenon has been termed "hibernating myocardium". Recently, cardiac imaging techniques that evaluate myocardial viability on the basis of perfusion-contraction mismatch and inotropic reserve have gained substantial popularity and clinical success. This review focus on the application of $^{201}TI$ and $^{99m}Tc-MIBI$ to address myocardial viability in patients with hibernating and stunned myocardium. It is clear that 4-hour redistribution images of $^{201}TI$ underestimate ischemia and overestimate scar. Delayed imaging and reinjection imaging have been developed for the assessment of viability. Among many protocols suggested, stress-redistribution-reinjection imaging gained most popularity. Although $^{99m}Tc-MIBI$ could identify myocardial viability, $^{201}TI$ reinjection technique was regarded as superior to it. In conclusion, $^{201}TI$ stress, 4-hr rest redistribution, and reinjection imaging technique may be the most preferable method for evaluation of myocardial viability.

  • PDF

Stability Evaluation on Particle Size Characteristics of Bed Materials at High-Velocity Flow (고유속 흐름에서 하상재료의 입도특성에 따른 안정성 평가연구)

  • Kim, Gwang Soo;Jung, Dong Gyu;Kim, Young Do;Park, Yong Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.365-376
    • /
    • 2021
  • In general, domestic streams and rivers are composed of alluvial rivers consisting of sand and gravel beds. These rivers can cause erosion and riverbed changes due to sudden changes in flow rates, such as floods, torrential rains, and heavy rains. In particular, there are various types of erosion, such as contraction erosion caused by changes in river shape, or local erosion occurring around obstacles such as piers, abutments or embankments. In addition, river changes can occur in various forms, such as static or dynamic periods, due to limitations such as flow rate, velocity, and shear stress. This study focused on the erosions of embankments directly related to human casualties among various river structures, and evaluated limit velocities and critical shear stress in order to identify changes in strength of natural materials by identifying the characteristics of natural hoan materials and resistance to erosions. In particular, the limitations of materials according to the type of materials in the river, characteristics of particles, and size of particles were studied using Soil loss, which is a change in the volume of the revetment material, and it is intended to be used as basic data for river design and restoration.

A Study on Physical Properties About Velvet Antler of the Elk(Cerus canadensis) (엘크 녹용의 물성 특성에 관한 연구)

  • Sung, S.H.;Han, J.H.;Kim, Y.M.;Kim, B.K.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.201-210
    • /
    • 2007
  • In this study, physical properties of Elk antler was investigated to develop the optimum drying and packaging methods for improving the antler quality as well as deal with diversify of demand. After the antler was sliced with 5 mm thickness, and the compressive, shear, and tensile stresses were measured at the center and velvet parts of pre-dried and dried antlers after the contained water rate of the dried antlers was maintained below 10%. The results are as follows. 1. Considering the center of pre-dried antlers, the compressive stresses were $60.73\;g/mm^2$, $145.65\;g/mm^2$, and $260.97\;g/mm^2$, respectively at the upper, middle, and lower parts while $70.67\;g/mm^2$, $811.90\;g/mm^2$, $3,235.52\;g/mm^2$, respectively for velvet layer. Considering the center of dried antlers, the compressive stresses were $190.43\;g/mm^2$, $445.81\;g/mm^2$, and $705.86\;g/mm^2$, respectively at the upper, middle, and lower parts while $734.01\;g/mm^2$, $1,238.40\;g/mm^2$, $4,134.03\;g/mm^2$, respectively for velvet layer. 2. For the pre-dried, the shear stresses were $50.24\;g/mm^2$, $294.44\;g/mm^2$, and $423.47\;g/mm^2$, respectively, and $124.14\;g/mm^2$, $367.69\;g/mm^2$, and $425.86\;g/mm^2$, respectively for the dried antlers. 3. The tensile stresses were $13.59\;g/mm^2$, $62.85\;g/mm^2$, and $112.07\;g/mm^2$, respectively for the pre-dried and $77.24\;g/mm^2$, $175.87\;g/mm^2$, and $184.06\;g/mm^2$, respectively for the dried antlers. 4. In the case of drying antlers, the physical characteristics of the antlers was. changed such as moisture evaporation, contraction, and surface hardening. For the center part, the changes of the physical characteristics were more significant at the lower part while at the upper part for the velvet layer. 5. The stress changes of Elk antlers was shown very remarkably according to growth point. Moreover, the stress was clearly higher at velvet layer part to the center part, base parts compared to the upper parts.

  • PDF

COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE (스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교)

  • Kim, Young-Kwang;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.516-526
    • /
    • 2004
  • Polymerization shrinkage of photoinitiation type composite resin cause several clinical problems. The purpose of this study was to evaluate the shrinkage strain stress, linear polymerization shrinkage, compressive strength and microhardness of recently developed composite resins. The composite resins were divided into four groups according to the contents of matrix and filler type. Group I : $Denfil^{TM}$(Vericom, Korea) with conventional matrix, Group II : $Charmfil^{(R)}$(Dentkist, Korea) with microfiller and nanofller mixture, Group III : $Filtek^{TM}$ Z250(3M-ESPE, USA) TEGDMA replaced by UDMA and Bis-EMA(6) in the matrix, and Group IV : $Filtek^{TM}$ Supreme(3M-ESPE, USA) using pure nanofiller. Preparation of acrylic molds were followed by filling and curing with light gun. Strain gauges were attached to each sample and the leads were connected to a strainmeter. With strainmeter shrinkage strain stress and linear polymerization shrinkage was measured for 10 minutes. The data detected at 1 minute and 10 minutes were analysed statistically with ONE-way ANOVA test. To evaluate the mechanical properties of tested materials, compressive hardness test and microhardness test were also rendered. The results can be summarized as follows : 1. Filling materials in acrylic molds showed initial temporary expansion in the early phase of polymerization. This was followed by contraction with the rapid increase in strain stress during the first 1 minute and gradually decreased during post-gel shrinkage phase. After 1 minute, there's no statistical differences of strain stress between groups. The highest strain stress was found in group IV and followed by group III, I, II at 10 minutes-measurement(p>.05). In regression analysis of strain stress, group III showed minimal inclination and followed by group II, I, IV during 1 minute. 2. In linear polymerization shrinkage test, the composite resins in every group showed initial increase of shrinkage velocity during the first 1 minute, followed by gradually decrease of shrinkage velocity. After 1 minute, group IV and group III showed statistical difference(p<.05). After 10 minutes, there were statistical differences between group IV and group I, III(p<.05) and between group II and group III(p<.05). In regression analysis of linear polymerization shrinkage, group II showed minimal inclination and followed by group IV, III, I during 1 minute. 3. In compressive strength test, group III showed the highest strength and followed by group II, IV, I. There were statistical differences between group III and group IV, I(p<.05). 4. In microhardness test, upper surfaces showed higher value than lower surfaces in every group(p<.05).

  • PDF

Diagnosis of Irrigation Time Based on Microchange of Stem Diameter in Greenhouse Tomato (온실재배 토마토의 농직경 변화에 의한 관개시기 진단)

  • 이변우
    • Journal of Bio-Environment Control
    • /
    • v.6 no.4
    • /
    • pp.250-257
    • /
    • 1997
  • Stem diameter and shoot fresh weight of tomato grown in greenhouse were measured non-destructively at 10 minutes interval from 1 to 16 July, 1996 with displacement detector using strain gauges and with suspension-type load cell, respectively, and simultaneously were measured soil water potential, transpiration and solar radiation. Ample water was irrigated before experiment, and thereafter, irrigations were made on the next morning when visual symptoms of wilting appeared. Shoot fresh weight and stem diameter showed very similar patterns in diurnal changes which are characterized by predawn maximum and afternoon minimum and in long- term evolutions, suggesting that stem diameter shrinkage and expansion are closely related to plant water content and growth, respectively, Shoot weight and stem diameter reached minimum values a little later than the time on which transpiration showed maximum. The daily net gains of fresh weight(DG) and stem diameter(DI) showed significantly Positive correlations with solar radiation in those days on which plants were not water-stressed. However, Dl and DG on those days of water stress showed much lower values than expected from the relationships between solar radiation and them. Transpiration was much lower than the expected potential transpiration on 10 July, implying that plants were water-stressed. In this case water stress was not detected from visual symptom of wilting and/or soil water potential, but was able to be identified by the lower DI and DG than the expected. The maximum contraction of stem diameter(MC) and the maximum loss of fresh weight(ML) during daytime showed significantly positive correlations with solar radiation in those days on which plants were not water-stressed and were observed greater than expected from the relationships on severely water-stressed days. But mild water stress could not be discernable by ML and MC. It would be concluded that the daily net gains of fresh weight and/or stem diameter could be used as criteria for diagnosing the water status of tomato and for triggoring the onset of irrigation in automatic system.

  • PDF

Student Experience and Satisfaction with Clinical Nursing Practice in Women's Health Nursing (간호학생의 여성건강간호학 임상실습 경험 및 만족도 조사)

  • Kim, Yun-Mi;Chun, Na-Mi;Lee, Eun-Hee;Cho, In-Sook;Ahn, Suk-Hee;Kim, Jeung-Im;Hur, Myung-Haeng;Lee, Sook-Hee;Lee, Hae-Kyung;Chung, Chae-Weon;Kang, Nam-Mi;Kim, Hae-Won
    • Women's Health Nursing
    • /
    • v.17 no.3
    • /
    • pp.225-242
    • /
    • 2011
  • Purpose: The purpose of this study was to identify students' experiences of performance and their satisfaction with clinical nursing practice in Women's health nursing. Methods: Data was collected using questionnaire consisting of 104; 89,; and 82 nursing activities with 12; 10; and 7 domains for delivery floor, obstetric, and gynecologic wards retrospectively. Five hundred ninety nursing students from 10 four year and one three year colleges, were recruited and selected for data collection. Results: Site specific core nursing activities among top 15 items of performed experience were: interpreting fetal monitoring; massage for pain reduction; breathing technique; perineal pad change; non stress test; manual check for uterine contraction; and position change for the delivery floor. Experiences of clinical nursing practice for the obstetric ward and the gynecologic ward were identified and ranked as well. Observation of delivery, measurement & test during labor and observation of anesthesia and operation were the highest ranked activity domains of satisfaction for delivery floor, obstetric and gynecologic wards retrospectively. Conclusion: Discussions are needed to standardize curriculum for clinical practice in women's health nursing initiated at the level of Korean Society of Womens' Health Nursing by reflecting this result. Strategic approaches are emphasized in order to enhance a collaboration between clinical fields and colleges.

EFFECT OF RESIN MATRIX ON DEGREE OF CONVERSION AND FRACTURE TOUGHNESS OF DENIAL COMPOSITES (기질레진의 조성에 따른 복합레진의 물리적 성질에 관한 연구)

  • Lee, Yun-Shin;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical proper-ties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the pro-portion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K$_{1c}$) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filer contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level. The results were as follows; 1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin 2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity. 3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA. 4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased. 5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity. These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.