• 제목/요약/키워드: Contraction ratio

검색결과 239건 처리시간 0.023초

Endurance Capacity of the Biceps Brachii Muscle Using the High-to-Low Ratio between Two Signal Spectral Moments of Surface EMG Signals during Isotonic Contractions

  • Lee, Sang-Sik;Jang, Jee-Hun;Cho, Chang-Ok;Kim, Dong-Jun;Moon, Gun-Pil;Kim, Buom;Choi, Ahn-Ryul;Lee, Ki-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1641-1648
    • /
    • 2017
  • Many researchers had examined the validity of using the high-to-low ratio between two fixed frequency band amplitudes (H/L-FFB) from the surface electromyography of a face and body as the first spectral index to assess muscle fatigue. Despite these studies, the disadvantage of this index is the lack of a criterion for choosing the optimal border frequency. We tested the potential of using the high-to-low ratio between two signal spectral moments (H/L-SSM), without fixed border frequencies, to evaluate muscle fatigue and predict endurance time ($T_{end}$), which was determined when the subject was exhausted and could no longer follow the fixed contraction cycle. Ten healthy participants performed five sets of voluntary isotonic contractions until they could only produce 10% and 20% of their maximum voluntary contraction (MVC). The $T_{end}$ values for all participants were $138{\pm}35s$ at 10% MVC and $69{\pm}20s$ at 20% MVC. Changes in conventional spectral indices, such as the mean power frequency (MPF), Dimitrov spectral index (DSI), H/L-FFB, and H/L-SSM, were extracted from surface EMG signals and were monitored using the initial slope computed every 10% of $T_{end}$ as a statistical indicator and compared as a predictor of $T_{end}$. Significant correlations were found between $T_{end}$ and the initial H/L-SSM slope as computed over 30% of $T_{end}$. In conclusion, initial H/L-SSM slope can be used to describe changes in the spectral content of surface EMG signals and can be employed as a good predictor of $T_{end}$ compared to that of conventional spectral indices.

Comparative Study of Infraspinatus and Posterior Deltoid Muscle Activation According to Angle of External Rotation of Glenohumeral Joint

  • Yang, Dongseok;Choi, Wonho
    • 국제물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.2071-2076
    • /
    • 2020
  • Background: Based on the understanding of the muscle activation relationship between the infraspinatus and posterior deltoid muscles to according to the angle of motion during external rotation on glenohumeral joint, effective shoulder joint strengthening exercise for the prevention and rehabilitation of shoulder injury due to muscle strength imbalance can be performed by achieving the ideal muscle activity ratio during exercise. Objectives: To compare and analyze the muscle activation changes and activity ratio of the infraspinatus and posterior deltoid muscles according to the glenohumeral external rotation angle. Design: Quasi-randomized trial. Methods: The study included 48 healthy male and female adults who provided informed consent for participation in the study. All the subjects performed isometric glenohumeral external rotation by setting the angle of motion to 30°, 45°, and 60° using a 5 kg resistance weight pulley. On surface electromyography, the differences in muscle activation and activity ratio between the infraspinatus and posterior deltoid muscles were investigated. Results: A significant difference in muscle activation was found in the comparison between the infraspinatus and posterior deltoid muscles according to the glenohumeral external rotation angle (P<.05). The muscle activation levels of the infraspinatus and posterior deltoid muscles were highest at the external rotation angles of 30° and 60°, respectively. The muscle activity ratio between the infraspinatus and posterior deltoid muscles also showed a significant difference (P<.05) and was highest at the shoulder external rotation angle of 30°. Conclusion: The findings of this study suggest that muscle activity is the highest at the shoulder external rotation angle of 30° in healthy individuals.

급성과 만성 편타성-관련 손상 환자의 상지 거상과 하강 동작시 상승모근과 하승모근의 근활성도 비교 (Comparison of Upper and Lower Trapezius Activity During Shoulder Elevation and Depression for Acute and Chronic Whiplash-associated Disorder Patients)

  • 김상수;김선엽
    • 대한정형도수물리치료학회지
    • /
    • 제16권1호
    • /
    • pp.26-36
    • /
    • 2010
  • Purpose: The study compared the muscle activity and ratio of upper trapezius (UT) to lower trapezius (LT) activity between acute and chronic whiplash-associated disorder (WAD) patients. Methods: Twelve healthy (male: 7), 14 acute WAD (male: 7), and 11 chronic WAD (male: 3) volunteers participated in this study. Electromyography using a surface EMG recorded the activity of the upper trapezius and lower trapezius of both shoulders (dominant and non-dominant) during $120^{\circ}$ elevation when standing and shoulder depression when sitting. The testing order was selected randomly. Subjects were asked to maintain each experimental position for 5 seconds at end range. EMG activity was normalized using the maximal voluntary isometric contraction (MVIC) elicited using a manual muscle-testing technique. One-way repeated measures analysis of variance (ANOVA) was used to compare the average root mean square (RMS) value of EMG activity for each condition. Results: The EMG activity of the dominant UT for chronic WAD subjects was significantly higher than for acute WAD subjects during $120^{\circ}$ elevation (p<.05). The EMG activity of the dominant LT for acute WAD subjects was significantly lower than for the control group (p<.05) during $120^{\circ}$ elevation. The EMG activity of the dominant LT for WAD patients was significantly lower than for the control group during shoulder depression (p<.05), and the chronic WAD patients scored significantly the lowest (p<.01). The dominant UT/LT for chronic WAD patients was significantly higher than the ratio for acute WAD subjects during shoulder depression (p<.05); this result was higher than for the control group (p<.01). The non-dominant UT/LT (ratio) for chronic WAD patients was significantly higher than the ratio for acute WAD subjects during shoulder depression (p<.05). Conclusion: The UT for chronic WAD subjects was hyperactive when compared to the acute WAD subjects, and the was hypoactive for both acute and chronic patients, therefore intra-trapezius imbalance was more prevalent during shoulder depression.

  • PDF

입는 외골격 로봇을 위한 선형화된 출력을 갖는 회전형 줄꼬임 기반 구동기 (Rotational Twisted String Actuator with Linearized Output for a Wearable Exoskeleton)

  • 우스만 매흐무드;드미트리 포포프;이고르 가파노브;유지환
    • 제어로봇시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.524-530
    • /
    • 2015
  • Early wearable robotic devices were big, powerful and manipulator-like. Recently, various applications of wearable robotics have shown a greater demand for lower weight and compliancy. One approach to achieve these objectives is the use of novel actuators such as twisted string actuators. These actuator are very light, quiet, mechanically simple and compliant. Therefore, they can drastically decrease the weight and size of robotic systems such as exoskeletons. However, one drawback of this actuator is its nonlinear transmission ratio, which is established as a ratio between the angle of twisting of the strings and their resulting contraction. In this paper, we propose a transmission mechanism with rotational motion as the output incorporating a twisted string actuator (TSA). The designed mechanism allows the linearization of the relationships between the input and output displacements and forces of a TSA. The proposed design has been validated theoretically and through a set of computer simulations. A detailed analysis of the performance of the proposed mechanism is presented in this paper along with a design guideline.

Hydro-mechanical behavior of compacted silt over a wide suction range

  • Chen, Bo;Ding, Xiuheng;Gao, You;Sun, De'an;Yu, Haihao
    • Geomechanics and Engineering
    • /
    • 제22권3호
    • /
    • pp.237-244
    • /
    • 2020
  • To achieve a wide suction range, the low suction was imposed on compacted silt specimens by the axis translation technique and the high suction was imposed by the vapor equilibrium technique with saturated salt solutions. Firstly, the results of soil water retention tests on compacted silt show that the soil water retention curves in terms of gravimetric water content versus suction relation are independent of the dry density or void ratio in a high suction range. Therefore, triaxial tests on compacted silt with constant water content at high suctions can be considered as that with constant suction. Secondly, the results of triaxial shear tests on unsaturated compacted silt with the initial void ratio of about 0.75 show a strain-hardening behavior with a slightly shear contraction and then strain-softening behavior with an obviously dilation. As the imposed suction increases, the shear strength increases up to a peak value and then decreases when the suction is beyond a special value corresponding to the peak shear strength. The residual strength increases to fair value and those at high suctions are almost independent of imposed suctions. In addition, the contribution of suction to the strength of compacted silt would not diminish even in a high suction range.

동잡음의 영향을 개선한 비관혈식 산소포화도 측정 알고리즘에 대한 연구 (A study on non-invasive SaO$_2$ measurement algorithm to improve on effect of the motion artifact)

  • 이준하
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.101-107
    • /
    • 2000
  • 펄스옥시메트리는 서로 다른 두 파장의 빛을 이용하여 동맥혈의 산소포화도를 측정하는 비침습성의 광에 의한 측정 방법이다. 동맥혈의 맥동성분은 정맥혈, 피부 그리고 기타의 비맥동성분들에 의해 감쇠되는 직류 성분에 중첩되어 있다. 본 논문에서는 맥동 성분의 적분비를 이용하여 산소포화도를 계산하는 알고리즘을 사용하였다. 알고리즘에서는, 심장의 수축과 관련되는 맥동신호의 1/2 싸이클만을 이용한다. 이용하는 시간은 1 cycle의 약 1/4이다. 1/4 주기를 이용하는 본 알고리즘은 기존의 방식과 유사한 결과가 나타났다. 신호의 진폭이 낮고, 시간의 점유가 많은 부분을 계산에서 배제했기 때문에, 동잡음의 영향이 감소되었다.

  • PDF

디지털 화상처리를 이용한 차축 Casing Nut 용접부 치수 검사 프로그램 개발에 관한 연구 (A study on the development of dimension inspect Program for the vehicle axle casing nut welding part using digital image processing)

  • 김재열
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.135-143
    • /
    • 2000
  • The vision system is easy to use the exclusive use as a independent computer system but it is not much popularization by reason of expensive and difficult to adapt to the various fields, because it is easy to the existed computer system, the price is cheap and also it can use to the various measurement purpose which user wanted and programed. The measurement method of the vehicle axle casing nut welding part is that measure the value of the welding part to adapt the actual operation program from using the ratio between the actual length of the standard specimen and the length of image, to measure the ratio between the actual product and the camera image. A defect is found by the assembled visual inspection system. The inspection algorithm which estimates the quality of welded product is developed and also, the software program which processes the automatic test function of the inspection system. We make the foundation of the inspection automatic system and we will help to apply other welding machine.

  • PDF

사출 금형 수축률 산정에 관한 연구 (A Study on injection mold shrinkage estimates)

  • 최광혁;한성렬;이춘규
    • Design & Manufacturing
    • /
    • 제10권3호
    • /
    • pp.30-33
    • /
    • 2016
  • It is true that the plastic shrinkage is inevitable. Shrinkage rate in effect at the time of mold design will soon determine the size of the global product. Process for the shrinkage of the plastic that provides how made, yet it has identified a process for making the question whether the shrinkage that can be trusted, and by the experimental results were as follows: as shrinkage, see ISO but, according to circumstances the process can go to the agreement between the parties. shrinkage ratio of the pressure sensor installed in the specimen mold is essential, amount of pressure sensor is that it is appropriate approximately 2-3. proper holding pressure is a significant effect on shrinkage Mitch, so that the effect of selecting the contraction ratio data according to the appropriate holding pressure during mold making. shrinkage CAE analysis results are difficult to utilize in the mold-making chamber. Based on these results, it concluded by looking forward to the improved products produced shrinkage.

승모판막 수술에 따른 심전도 변화 (The Study on Electrocardiographic Changes after Mitral Valvular Replacement)

  • 여승동;임승평
    • Journal of Chest Surgery
    • /
    • 제24권4호
    • /
    • pp.421-427
    • /
    • 1991
  • Atrial fibrillation[Af] is closely related to thrombus in left atrium, systemic embolism, and loss of the contribution of atrial contraction to cardiac output. Therefore maintenance of sinus rhythm[SR] is undoubtedly hemodynamically superior to Af in the clinical course of mitral valvular disease especially in the unstable period immediately after surgery. In this article, the conversion rate and the factors influencing the conversion of Af to SR after surgery were studied. Ninety-three patients with mitral valvular replacement at Chungnam National University Hospital were analysed with electrocardiography before and after surgery during the period from June 1985 to June 1990. Eighty patients presented Af before surgery. Twenty-four[30Yo] of the patients were converted to SR[A group] and fifty six presented continuous Af after surgery[B group]. The duration of preoperative Af, preoperative left atrial dimension[LAD], preoperative functional status[NYHA classification] and cardiothoracic[CT] ratio were factors influencing the conversion of Af to SR after surgery. The mean preoperative duration of Af was 3.5$\pm$2.6yr in group A and 7.6$\pm$4.9yr in group B. The mean preoperative LAD was 53. 7$\pm$9.4mm in group A and 62.5$\pm$11.2mm in group B. Before surgery, eleven patients[46%] were belong to NYHA class I, II in group A and eight[14%] in group B. The preoperative CT ratio was 62$\pm$6% in group A and 69$\pm$8% in group B.

  • PDF

깔때기 경사충격파를 고려한 환형 분사 초음속 이젝터 이론해석 (Theoretical Analysis of Annular Injection Supersonic Ejector with a Simple Funnel Shock Wave Model)

  • 김세훈;권세진
    • 한국추진공학회지
    • /
    • 제10권1호
    • /
    • pp.23-29
    • /
    • 2006
  • 환형 분사 초음속 이젝터에서는 초음속의 주유동이 벽면을 타고 분사되므로 주유동 노즐 출구(혼합 챔버 입구)에서 혼합챔버의 수축각에 의한 깔때기(funnel) 모양의 경사충격파가 발생한다. 본 연구에서는 이차원(Wedge) 경사충격파와 원뿔(Cone) 경사충격파를 이용하여 간단한 깔때기 경사충격파 모델링(Modeling)을 수행하였다. 이러한 모델링을 이용하여 기존의 이차원 경사충격파를 이용한 이론해석 보다 부유동 압력을 보다 정확히 예측할 수 있었다. 같은 해석 방법을 이용하여 유량비에 대한 초음속 이젝터의 압축비와 단열 효율을 얻을 수 있었다.