• Title/Summary/Keyword: Continuous wave of condensation technique

Search Result 19, Processing Time 0.025 seconds

Influence of plugger penetration depth on the apical extrusion of root canal sealer in Continuous Wave of Condensation Technique (플러거 삽입깊이가 근관실러의 치근단 정출에 미치는 영향)

  • So Ho-Young;Lee Young-Mi;Kim Kwang-Keun;Kim Ki-Ok;Kim Young-Kyung;Kim Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.439-445
    • /
    • 2004
  • The purpose of this study was to evaluate the influence of plugger penetration depth on the apical extrusion of root canal sealer during root canal obturation with Continuous Wave of Condensation Technique. Root canals of forty extracted human teeth were divided into four groups and were prepared up to size 40 of 0.06 taper with ProFile. After drying. canals of three groups were filled with Continuous Wave of Condensation Technique with System $B^{TM}$ and different plugger penetration depths of 3. 5, and 7 mm from the apex. Canals of one group were filled with cold lateral compaction technique as a control. Canals were filled with non-standardized master gutta-percha cones and 0.02 mL of Sealapex. Apical extruded sealer was collected in a container and weighed. Data was analyzed with one-way ANOVA and Duncan's Multiple Range Test. 3 and 5 mm penetration depth groups in Continuous Wave of Condensation Technique showed significantly more extrusion of root canal sealer than 7 mm penetration depth group (p < 0.05). However, there was no significant difference between 7 mm depth group in Continuous Wave of Condensation Technique and cold lateral compaction group (p < 0.05). The result of this study demonstrates that deeper plugger penetration depth causes more extrusion of root canal sealer in root canal obturation by Continuous Wave of Condensation Technique. Therefore, special caution is needed when plugger penetration is deeper in the canal in Continuous Wave of Condensation Technique to minimize the amount of sealer extrusion beyond apex.

AN in vitro STUDY OF THE CORONAL LEAKAGE OF TWO ROOT CANAL FILLING TECHNIQUE USING ANAEROBIC BACTERIAL LEAKAGE MODEL (근관 충전된 치아에서의 혐기성세균을 이용한 치관부 미세누출측정에 관한 연구)

  • Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.490-494
    • /
    • 1999
  • The aim of this in vitro study was to investigate the coronal leakage of obligate anaerobes into root canals obturated with two different techniques. 48 extracted human teeth with straight, single root canals were prepared with crown-down technique with Profile under copious irrigation until the master apical file was size 40. The teeth were divided randomly into experimental groups (40 teeth) and control groups (8 teeth). In the experimental groups, 20 teeth were obturated with lateral condensation and other 20 teeth were obturated with continuous wave technique with System B. Coronal leakage of two root canal filing technique was evaluated using anaerobic bacterial leakage model with Fusobacterium nucleatum(ATCC 25586) for 60 days. The results were as follows 1. The incidence of bacterial leakage of experimental groups was 65% in group 1 (lateral condensation) and 60% in group 2 (continuous wave technique with System B). This difference was not statistically significant (P>0.05). 2. There was no statistically significant difference(P>0.05) in leakage score between group 1 (lateral condensation) and group2 (continuous wave technique with System B).

  • PDF

COMPARISON OF THE SEALING ABILITY OF VARIOUS ROOT CANAL FILLING TECHNIQUES (근관충전방법에 따른 폐쇄효과의 비교)

  • Lee, Dong-Kyoung;Yoon, Soo-Han;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.346-356
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of various canal filling methods. Palatal roots of ninety extracted human maxillary molar teeth were resected at cementoenamel junction. Eighty of them were randomly assigned to four experimental groups, ten were served as positive and negative controls. All canals were prepared to # 40 using Profile. Experimental groups were obturated by lateral condensation technique, Thermafil technique, Continuous Wave of Condensation Technique, and down-pack & back-fill technique of Obtura-II, each with root canal sealer. Control groups were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then ground horizontally at 1.5mm(level 1), 2.5mm(level 2), 3.5 mm(level 3) from the anatomical apex and examined with a stereomicroscope at ${\times}40$ magnification. The gap between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (Rank-sum test). The results were as follows : 1. At the level 1, there was the greatest leakage in the Thermafil group and Obtura-II group, and the difference between the Obtura-II group and Continuous Wave of Condensation Technique group was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the Continuous Wave of Condensation Technique group, but there was no statistically significant difference between each group (p>0.05). 3. At the level 3, there was no statistically significant difference between each group(p>0.05).

  • PDF

ANALYSIS OF TEMPERATURE RISE ON THE ROOT SURFACE DURING CONTINUOUS WAVE OF CONDENSATION TECHNIQUE (Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석)

  • Kim, Young-Ju;Hwang, Yun-Chan;Kim, Sun-Ho;Hwang, In-Nam;Choi, Bo-Young;Jeong, Young-Jin;Juhng, Woo-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.341-347
    • /
    • 2003
  • This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1 mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed $130.82{\pm}2.96^{\circ}C,{\;}158.00{\pm}5.26^{\circ}C,{\;}215.92{\pm}6.91^{\circ}C{\;}and{\;}249.88{\pm}3.65^{\circ}C$ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.0l). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was $2.37{\pm}0.09^{\circ}C{\;}at{\;}150^{\circ}C{\;}setting,{\;}3.11{\pm}0.12^{\circ}C{\;}at{\;}200^{\circ}{\;}setting,{\;}3.93{\pm}0.09^{\circ}C{\;}at{\;}250^{\circ}C{\;}setting{\;}and{\;}5.69{\pm}0.15^{\circ}C{\;}at{\;}300^{\circ}C$ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings on digital temperature display of System B HeatSource.

Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha (Plugger 삽입깊이가 근관내 gutta-percha 점유면적에 미치는 영향)

  • Lee, Young-Mi;So, Ho-Young;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.66-71
    • /
    • 2006
  • To evaluate the ratio of gutta-percha area in the canal after canal obturation with Continuous Wave of Condensation Technique (CWCT) with varying depths of plugger penetration, forty root canals of extracted human teeth were prepared up to size 40 of 0.06 taper with $ProFile^{(R)}$. Canals of three groups were filled with CWCT with System $B^{TM}$ (Analytic Tech. , USA) and different plugger penetration depths of 3, 5, or 7 mm from the apex. Canals of one group were filled with lateral condensation technique as a control The felled teeth were cross-sectioned at 1, 2 and 3 mm levels from the apical foramen. The ratio of gutta-percha area in the canal was analyzed using $Auto^{(R)}$ Cad 2000. Data were analyzed with one-way ANOVA and Duncan's multiple range test. At all levels, higher gutta-percha area ratio was found with deeper plugger penetration depth in CWCT, and cold lateral condensation group showed higher ratio than group of plugger penetration to apical 7 mm in CWCT. At apical 1 mm and 2 mm levels, group of plugger penetration to apical 3 mm showed significantly high or gutta-percha area ratio than those of apical 7 mm and lateral condensation (p<0.05). It is concluded therefore that, under the conditions of the present study, deeper plugger penetration depth results in more favorable and efficient obturation in CWCT.

COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS (GT rotary file을 이용한 근관성형법과 충전방법의 비교)

  • Kang, Yu-Mi;Jin, Jeong-Hee;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha

  • Lee, Young-Mi;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.557-557
    • /
    • 2003
  • I. Objectives The purpose of this study was to evaluate the ratio of gutta-percha area in the canal after canal obturation with Continuous Wave of Condensation Technique with varying depths of plugger penetration. II. Materials and Methods Forty extracted human teeth with single canal were divided into four group of ten teeth each. Root canals were prepared up to size 40 of 0.06 taper with $ProFile^{\circledR}$. After drying, canals of three groups were filled with Continuous Wave of Condensation Technique with System $B^{TM}$ and different plugger penetration depths of 3, 5, and 7mm from the apex.(omitted)

  • PDF

THE EFFECT OF CANAL OBTURATION ACCORDING TO THE DEPTH OF THE SYSTEM B PLUGGER TIP IN THE TYPE IV CANAL (제 IV 형 근관에서 System B Plugger tip의 깊이에 따른 근관 충전 효과)

  • Choi, Hee-Won;Kim, Soo-Mee;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.518-525
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of the apical sealing according to the depth of the System B Plugger tip when root canal was filled with gutta-percha and sealer by Continuous Wave of Condensation technique in the Type IV canal. 50 simulated resin blocks with J-shaped curvature canals were instrumented by ProTaper (Dentsply Maillefer, Ballagiues, Switzerland) Ni-Ti files using the crown-down technique. Type IV canals were made using a broken ProTaper F3 Ni-Ti file for making a ledge at 3mm short from the working length. And ProTaper F1 Ni-Ti file was used for perforating resin block. The prepared Type IV canals were randomly divided into three experimental groups of 15 each according to the depth of System B Plugger tip. All of experimental groups were obturated with Continuous Wave of Condensation technique. The length of gutta-percha and sealer in lingual of the Type IV canals was measured with a measuring digital calliper under magnifying glass (${\times}2.3$). The results are as follows : 1. In control group, there was no gutta-percha and sealer in lingual canal. 2. 3 mm group showed relatively more gutta-percha than 5mm or 7 mm group (p<0.05). 3. 7 mm group did not showed gutta-percha and relatively more void were observed than 3mm or 5 mm group. (p<0.05) In conclusion, within the limits of the results of this experiment, the 3 mm depth of System B Plugger tip was acceptable for obturating the Type IV canal.

THE EFFECTS OF THERMOCONDENSATION TECHNIQUE USING SYSTEM BTM ON THE PERIODONTIUM (System BTM를 이용한 열가압 충전시의 치주인대내에 미치는 영향)

  • Kim, Jae-Wook;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.366-378
    • /
    • 1998
  • Thermocondensation root canal filling technique have been used to fill accessary canals or to obtain homogeneous root caral fillings. But these thermocondensation technique inevitably produce heat in the canal which can be transmitted through the dentin and cementum and consequently damage periodontal ligamental cells and osteoblasts. In this study, System $B^{TM}$(Analytic technology, WA.D.S.A.) was used to evaluate the reaction of periodontal ligament tissue to "Continous Wave condensation technique" introduced by Buchanan, and the transmitted root surface temperature was measured according to measured root thicknesses. 12 Mandibular incisors of two adult dogs were used for the experiment. 6 controls were filled by lateral condensation technique with sealer.3 specimens were apically filled by Continuous Wave technique at $200^{\circ}C$ for 5 seconds and remaining 3 specimens were additionally backfilled using System $B^{TM}$(Analytic technology, WA.D.S.A.) was used to evaluate the reaction of periodontal ligament tissue to "Continous Wave condensation technique" introduced by Buchanan, and the transmitted root surface temperature was measured according to measured root thicknesses. 12 Mandibular incisors of two adult dogs were used for the experiment. 6 controls were filled by lateral condensation technique with sealer.3 specimens were apically filled by Continuous Wave technique at $200^{\circ}C$ for 5 seconds and remaining 3 specimens were additionally backfilled using System $B^{TM}$ at $100^{\circ}C$ for 20 seconds. Six weeks later, the dogs were sacrificed and the teeth stained with Hematoxylin and Eosin for histologic examination. 6 extracted human teeth were used to measure the transmitted temperature. After cutting off the crown, the canals were prepared and divided into 3 groups with root thickness of 1.5mm, 1.0mm, 0.5mm, 2 teeth in each group. Inside each root canal, System $B^{TM}$ was heated as with the temperature for the apically condensed and the back filled group, and the transmitted heat was measured on the external surface of the root. The temperature of System $B^{TM}$ heat spreader at $200^{\circ}C$ and $100^{\circ}C$ was also measured at root temperature. It can be concluded as follows: 1. In the thin area (200-$250{\mu}m$) of the root, root resorption could be seen even with heating at $200^{\circ}C$ for 5 seconds. 2. When the spreader was heated at $200^{\circ}C$ for 5 seconds and additionally at $100^{\circ}C$ for 20 seconds for backfill, all teeth showed root resorption regardless of their root thickness. 3. The transmitted external root surface temperature was higher as the root thickness decreased and as the heating time increased. In the thermocompaction technique using System $B^{TM}$, the spreader should be heated for the minimal time and used only in the apical area. The heated spreader shouldn't inserted to the binding point of the canal and backfilling should be done with other means of minimally heated gutta percha technique.

  • PDF

A STUDY OF INSERTION DEPTH OF BUCHANAN PLUGGER AFTER SHAPING USING NI-TI ROTARY FILES IN SIMULATED RESIN ROOT CANALS (Simulated resin root canal에서 엔진 구동형 Ni-Ti 파일로 근관성형 후 Buchanan plugger의 근관 내 삽입깊이에 대한 비교 연구)

  • Park, Youn-Sik;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.125-132
    • /
    • 2006
  • This study was conducted to evaluate the insertion depth of Buchanan plugger after shaping by various Ni-Ti rotary files. It was conducted to determine which size of plugger are appropriate, when root canals are shaped with Ni-Ti rotary files and obturated by Continuous wave of condensation technique. Two type of eighty simulated resin blocks were used : J-shaped and straight shaped canal. The simulated canals were instrumented by ProTaper and ProFile. Buchanan pluggers were inserted into the canal, and then the image was recorded to scanner. The distance from the apex of the canal to the plugger tip was measured by image analysis program. Data were analyzed by one-way ANOVA followed by Scheffe's test. The results were as follows 1. In straight canal finished up to ProTaper F2 and F3 file, F and FM pluggers were inserted more than 5 mm short of working length. 2. In J-shaped canal finished up to ProTaper F2 file, F pluggers were inserted more than 5 mm short of working length. Finished up to ProTaper F3 file. F and FM pluggers were inserted more than 5 mm short of working length. 3. In straight and J-shaped canal finished up to ProFile .06/#20 and .06/#25, any of Buchanan plugger could not be inserted more than 5 mm short of working length. These results suggest that canals shaped by ProTaper could be obturated by Continuous wave of condensation technique with F and FM size Buchanan plugger.