• 제목/요약/키워드: Continuous wall

검색결과 303건 처리시간 0.022초

Analytical study of house wall and air temperature transients under on-off and proportional control for different wall type

  • Han, Kyu-Il
    • 수산해양기술연구
    • /
    • 제46권1호
    • /
    • pp.70-81
    • /
    • 2010
  • A mathematical model is formulated to study the effect of wall mass on the thermal performance of four different houses of different construction. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one -dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures is obtained using the Laplace transform method. Typical Meteorological Year data are processed to yield hourly average monthly values. These discrete data are then converted to a continuous, time dependent form using a Fast Fourier Transform method. This study is conducted using weather data from four different locations in the United States: Albuquerque, New mexico; Miami, Florida; Santa Maria, California; and Washington D.C. for both winter and summer conditions. A computer code is developed to calculate the wall temperature profile, room air temperature, and energy consumption loads. Three sets of results are calculated one for no auxiliary energy and two for different control mechanism -- an on-off controller and a proportional controller. Comparisons are made for the cases of two controllers. Heavy weight houses with insulation in mild weather areas (such as August in Santa Maria, California) show a high comfort level. Houses using proportional control experience a higher comfort level in comparison to houses using on-off control. The result shows that there is an effect of mass on the thermal performance of a heavily constructed house in mild weather conditions.

EFI 인젝터에 의한 연료분무의 벽면충돌 특성 (Wall Impingement Phenomena of a Fuel Spray Injected by an EFI Injector)

  • 김영일;신정아륭
    • 한국분무공학회지
    • /
    • 제9권1호
    • /
    • pp.37-42
    • /
    • 2004
  • In a port fuel injection system of engine, a large part of fuel injected into an intake port adheres on its wall and inlet valve. Consequently, the wall impinging spray interaction might occur the generation of several harmful phenomena. There are uncontrollable mixture formation, an accidental backfire and unburned hydrocarbons. Therefore, it is important to analyze the fuel behavior during the spray-wall interaction. In this study, splash characteristics of impingement and reflecting or scattering behavior of droplets of fuel injected from EFI nozzle were studied experimentally. A test fuel used is LAWS and its physical characteristics are similar to the conventional gasoline except for the ignition point. Since the liquid film formed immediately after impinging on an impingement plate is unstable, it is easy to cause secondary disintegration. In addition, when the intermittently impingement on the impingement plate with LAWS, the splash ratio is around 0.6. If an injection period becomes longer, liquid film will become thick and the splash ratio will fall bout 10 percent. On the other hand, when the injection period of an intermittent spray is long, the same time lapse as a continuous spray is shown.

  • PDF

사각 연속횡보강 선조립철근으로 단부횡보강된 RC 구조벽체의 모멘트-곡률 관계 (Moment-Curvature Relationship of RC Structural Walls with Confined Boundary Elements Using Pre-Fabricated Rectangular Continuous Hoops)

  • 김희도;이승현;조재희;김성현;강수민
    • 한국전산구조공학회논문집
    • /
    • 제35권1호
    • /
    • pp.45-55
    • /
    • 2022
  • 현 설계기준에서 제시한 단부횡보강 상세는 시공성과 생산품질이 현저히 떨어지므로 내진성능과 시공성을 확보할 수 있는 RC 구조벽체의 단부횡보강 상세 개발이 필요하다. 최근 선재 제작기술의 발전으로 다양한 선조립철근의 제작이 가능해지고 있으며 특히 다양한 연속횡보강 철근 상세의 제작이 가능하게 되었다. 본 연구에서는 사각 연속횡보강 선조립철근 단부횡보강 상세를 적용한 RC 구조벽체의 모멘트-곡률 관계에 대한 분석을 진행하였다. 비선형 단면해석에 의하면 사각 연속횡보강의 상세를 적용한 RC 구조벽체는 사각 연속횡보강 영역의 면적이 증가할수록 내진성능을 확보할 수 있다. 이러한 연구결과에 근거하여 사각 연속횡보강 선조립 철근의 상세 적용시, 단부횡보강 영역의 면적만큼 사각 연속횡보강 영역의 면적을 확보해야 한다.

The Overlapping Running Suture Method Using Single Knotless Barbed Absorbable Suture Material for Abdominal Wall Closure after Single Incision Laparoscopic Appendectomy: Comparison with the Traditional Interrupted Closure Technique

  • Kim, Dong Hyun;Park, Jung Ho;Joo, Jung Il;Jeon, Jang Yong;Lim, Sang Woo
    • Journal of Minimally Invasive Surgery
    • /
    • 제21권4호
    • /
    • pp.160-167
    • /
    • 2018
  • Purpose: The aim of our study was to present an abdominal wall closure technique using barbed suture $V-Loc^{TM}$ 90 after single incision laparoscopic appendectomy (SILA) and to compare perioperative outcomes with conventional layer by layer abdominal wall closure after SILA. Methods: From March 2014 to July 2016, a retrospective case-control study was conducted for a total of 269 consecutive patients who underwent SILA. According to abdominal wall closure methods, 129 patients were classified into the V-Loc closure group and 140 patients were assigned into the conventional layer by layer closure group. In the V-Loc group, abdominal wall closure was performed from the fascia to the skin with a single thread of unidirectional absorbable barbed suture $V-Loc^{TM}$ 90 2-0 using continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time ($40.0{\pm}15.4min$ vs. $44.9{\pm}16.3min$, p=0.013) and abdominal wall cusing continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time losure time ($5.5{\pm}0.9min$ vs. $6.5{\pm}0.8min$, p<0.001). Postoperative incision length was significantly shorter in the V-Loc closure group ($1.1{\pm}0.3cm$ vs. $1.8{\pm}0.4cm$, p<0.001). Postoperative wound pain, time to resume diet, postoperative hospital stay, complications including surgical site infection, or mean patient satisfaction score at one month after hospital discharge was not significantly different between the two groups. Conclusion: In conclusion, unidirectional knotless barbed suture is a safe alternative method for abdominal wall closure after SILA. It can save time while providing comparable cosmesis.

Structural Design and Construction of the Foundation of TOKYO SKYTREE

  • Konishi, Atsuo;Emura, Masaru
    • 국제초고층학회논문집
    • /
    • 제4권4호
    • /
    • pp.249-259
    • /
    • 2015
  • This paper introduces the structural design and construction method for the foundation of the TOKYO SKYTREE, a new digital broadcasting tower in Tokyo, which has a height of 634 meters. The surface layer of the ground is occupied by soft soil, thus the foundation of this tower is an SRC continuous underground wall pile, designed and developed to have horizontal rigidity and pull-out resistance. The structural integrity and construction method of the wall pile was verified with an on-site full scale pull-out test concluding a maximum load of 40,000 kN.

해안매립지에서의 추적자시험 및 수위변화특성 연구

  • 이진용;황대규;이명재;최예권;김정우;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.221-224
    • /
    • 2002
  • To demonstrate prevention of the leachate leakage out of the landfill with creating inward hydraulic gradient, a tracer test and continuous waterlevel monitoring at the Inside and outside of the barrier wall of a costal landfill were peformed. When the tracers were injected into the well outside of the vertical wall system with high water level, then they were detected at the well inside of the system with low water level. Furthermore the lowered water level at the inside of the landfill than that at the outside prevented leachate leakage out of the landfill. This study reports results of the tracer test and waterlevel monitoring.

  • PDF

Slip Form과 Deck Plate를 채용한 벽식 APT의 접합부 Detail개발의 기초적 연구 (The basic study of the detail development of the Wall-type APT joint using Slip Form and Deck plate.)

  • 이희두;박신;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.127-132
    • /
    • 2003
  • The purpose of current study is about how to construct wall-type APT in slip form and Deck plate applied different connection of materials that wall and slab. A proposal construct's solution is using the continuous a binding string that the main of contents are slab or stairs which horizon structure part construction is joined the vertical structure part, new we Proposed of 2 solution that new technology development. We'll suggest that the development is in the construct of higher stories APT more better other construction method. We expect that the new method is good but we have many things to solute themes. Thus, we decided that this development contents are needed that correct structural investigation and constructor's security of speciality and through a fact construct, correct verification.

  • PDF

경사진 벽충돌 디젤 분무에 대한 수치해석에서 오류확산이 미치는 영향 (Analysis of the False Diffusion Effects in Numerical Simulation of Diesel Spray Impinging on Inclined Walls)

  • 권혁록;이성혁
    • 한국분무공학회지
    • /
    • 제13권1호
    • /
    • pp.22-27
    • /
    • 2008
  • The false diffusion occurs generally when the flow is oblique to the grid lines and when there is a non-zero gradient of the dependent variable in the direction normal to the flow. This numerical problem can overestimate diffusion terms in the continuous phase, causing the numerical inaccuracy for the simulation of impinging sprays on inclined walls because most of spray calculation uses rectangular grid system. Therefore, the main objective of this article is to investigate numerically the influence of false diffusion on numerical simulation for spray-wall impingement on inclined walls. It is found that unlike the spray impingement normal to the wall, the numerical diffusion exists in the case when diesel sprays impinge on the inclined walls with different angles. The results show that the correction function should be considered for accurate prediction of spray penetration length and more elaborate numerical schemes should be utilized to reduce the false diffusion.

  • PDF

Comparison of the Characteristics of Green Screen and LED Wall in Virtual Production System

  • Shan, Xinyi;Chung, Jeanhun
    • International journal of advanced smart convergence
    • /
    • 제11권2호
    • /
    • pp.64-70
    • /
    • 2022
  • In recent years, with the continuous innovation and upgrading of engine software, the real-time rendering technology in film and television has been continuously improved, and the virtual production technology has also developed rapidly. This paper introduces the green screen often used in traditional film production and a virtual production technology based on light-emitting-diode background wall that was proposed and implemented last year. We analyzed the two production methods of virtual production and compared their characteristics. Based on these results, we can better understand the differences and respective advantages of the two production methods. And we also can according to the production budget, production cycle and the creative and technical capabilities of the team make better choices during the production process. We believe virtual production technology will be production in the future to provide a more solid technical guarantee for the development of the film industry, and this work will pave the way for further research on virtual production technology.

Neural Fuzzy Mold Level Control for Continuous Steel Casting

  • Lim, Chang-Gyoon;Kueon, Yeong-Seob;Kim, Yigon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제2권2호
    • /
    • pp.146-152
    • /
    • 2002
  • Mold level control has been a major control task for continuous casting plants. The system involves nonlinearities such as stick-slip friction in the sliding gate, time-delay, friction force variations between molten steel and the inner wall of mold, and nozzle logging/unclogging. These complex problems should be solved to control mold level for steel cast. In this paper, we propose a neural fuzzy mold level control technique for solving these complex problems and give experiment studies to show the mold level control in continuous casting process.