• Title/Summary/Keyword: Continuous ultrasound

Search Result 100, Processing Time 0.028 seconds

Convergence Risk Factors for Thyroid Nodules Diagnosed Ultrasound (초음파검사로 진단된 갑상선결절의 융복합 위험요인)

  • Lee, Hye-Nam;Park, Yeon-Hwa
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.305-310
    • /
    • 2016
  • Recently as the ultrasonography became generalized, the annual change rate of the incidence of thyroid cancer extraordinarily grew to 24.5% in Korea. Therefore, the aim of this study was performed to identify the risk factors of thyroid cancer apart from conventional risk factors of dietary iodine and ionizing radiation. In this retrospective study, 411 patients underwent fine-needle aspiration biopsy were examined from January 2011 to March 2013. The subjects are divided into two groups which are 260 patients with benign nodule and 151 patients with malignancy nodule. We compared age, hematologic values, body mass index, waist circumference, menopausal status, breast nodules status, uterine myoma status, fatty liver status of targeted group of patients. According to the result, in thyroid cancer group with obesity, the number of case of breast nodules and myoma was higher, and their thyroid stimulating hormone values was higher than the benign nodule group. In order to establish factors influencing thyroid and thyroid cancer, there is a definite need for continuous study.

Follow-Up Intervals for Breast Imaging Reporting and Data System Category 3 Lesions on Screening Ultrasound in Screening and Tertiary Referral Centers

  • Sun Huh;Hee Jung Suh;Eun-Kyung Kim;Min Jung Kim;Jung Hyun Yoon;Vivian Youngjean Park;Hee Jung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1027-1035
    • /
    • 2020
  • Objective: To assess the appropriate follow-up interval, and rate and timepoint of cancer detection in women with Breast Imaging Reporting and Data System (BI-RADS) 3 lesions on screening ultrasonography (US) according to the type of institution. Materials and Methods: A total of 1451 asymptomatic women who had negative or benign findings on screening mammogram, BI-RADS 3 assessment on screening US, and at least 6 months of follow-up were included. The median follow-up interval was 30.8 months (range, 6.8-52.9 months). The cancer detection rate, cancer detection timepoint, risk factors, and clinicopathological characteristics were compared between the screening and tertiary centers. Nominal variables were compared using the chi-square or Fisher's exact test and continuous variables were compared using the independent t test or Mann-Whitney U test. Results: In 1451 women, 19 cancers (1.3%) were detected; two (0.1%) were diagnosed at 6 months and 17 (1.2%) were diagnosed after 12.3 months. The malignancy rates were both 1.3% in the screening (9 of 699) and tertiary (10 of 752) centers. In the screening center, all nine cancers were invasive cancers and diagnosed after 12.3 months. In the tertiary center, two were ductal carcinomas in situ and eight were invasive cancers. Two of the invasive cancers were diagnosed at 6 months and the remaining eight cancers newly developed after 13.1 months. Conclusion: One-year follow-up rather than 6-month follow-up may be suitable for BI-RADS 3 lesions on screening US found in screening centers. However, more caution is needed regarding similar findings in tertiary centers where 6-month follow-up may be more appropriate.

The Relationship between Perceived Stress Scale and Carotid Intima-Media Thickness Using Ultrasonography in University Students (대학생들의 스트레스 지각 정도와 경동맥 내막-중막 두께의 관계 연구)

  • Kim, Dae-Sik;Sung, Hyun-Ho;Lee, Jong-Woo;Cho, Eun-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.308-315
    • /
    • 2017
  • Carotid artery intima-media thickness (CIMT) test is a standardized ultrasound procedure that screens for and monitors atherosclerosis in a safe and non-invasive manner, even in individuals with no symptoms of heart disease. The purpose of this study was to research the relationship between CIMT, as measured by ultrasonography, and the degree of individual perceived stress. There was a total of 168 (male: 46, female: 122) university students in Suwon-si, Gyeonggi-do, Korea, without other diseases. Written informed consent was obtained from all participants. CIMT was measured in the right and left common carotid arteries 1 cm below the bifurcation, and internal carotid artery, using non-invasive high-resolution Medison Accuvix V20 prestige ultrasound equipment and perceived stress, was measured with the 10-item PSS (Perceived Stress Scale) questionnaire. This study indicates that PSS may be appropriate to estimate perceived stress levels and weight. Failure to control stress anxiety could lead to weight and CIMT soaring to dangerous levels, resulting in a myocardial infarction or cerebrovascular accident. There was a statistically significant difference between left CIMT (p<0.05) and weight (p<0.05) according to each stress classification. The results of this study suggest that the weight measurement is influenced in part by one's generalized stress levels. Future continuous studies should be conducted to test the influences of perceived stress and generalized anxiety on CIMT when these are many continuous variables.

Comparison of Two Different Schemes of Once-weekly Ovum Pick Up in Dairy Heifers

  • Yang, Xiao-Yu;Li, Hua;Huang, Wen-Ying;Huang, Shu-Zhen;Zeng, Yi-tao
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.3
    • /
    • pp.314-319
    • /
    • 2005
  • To compare two different schemes, continuous scheme (CS) and discontinuous scheme (DCS), of once-weekly ovum pick up (OPU) with ultrasound-guided follicular puncture technique, Holstein heifers were randomly divided into two groups of five. After characterization of their two normal estrous cycles, the heifers were subjected to consecutive 20 weeks of once-weekly OPU under two schemes: the CS (one week interval between continuous OPU, total 100 OPU sessions performed) and the DCS (OPU fixed to the day 3 and day 10 of each estrus). Then, the status of ovaries and artificial insemination results were observed. On oocyte yield, the total number of punctured follicles using DCS was lower than that using CS, but the mean numbers of punctured follicles and recovered oocytes per session were higher in DCS than CS group. So the total number of recovered oocytes was similar in both groups. There were also no differences in the quality of recovered oocytes, nor in the developmental ability of oocytes fertilized in vitro between groups. The heifers in the DCS group showed regular estrous cycles with stable estrous signs through the periods of before, during, and after OPU, while those in CS group showed longer estrous cycles and less estrous signs during and/or after OPU compared with before period. Furthermore, the mean number of inseminations required for obtaining pregnancy after completion of the experiments was lower in DCS than CS group. The research demonstrates that similar quantity and quality oocytes can be achieved, and the side effects on donors are lower in DCS that needs fewer OPUs than CS group, and DCS is superior to CS.

The Effect of Thread-embedding therapy on 9 Patients with Partial Obesity (매선요법을 이용한 부분비만치료 9례 보고)

  • Shin, Hwa-Young;Kwon, Hyo-Jung;Lee, Yun-Kyu;Lim, Seong-Chul;Jung, Tae-Young;Lee, Bong-Hyo;Kim, Jae-Su
    • Journal of Acupuncture Research
    • /
    • v.28 no.6
    • /
    • pp.27-34
    • /
    • 2011
  • Objectives : The purpose of this study was to examine the effect of thread-embedding therapy against partial obesity. Methods : 9 women from 20 to 30 with partial obesity were treated with thread-embedding therapy and then surveyed satisfaction, reaction after treatment and whether they were re-treated or not. The results of before and after treatment were compared with physical measurement, body composition tests and fat thickness measured by ultrasound. Results : The satisfaction of patients was high and side effects were pain, bruises and unnaturalness of action, but 8 of 9 patients wanted to re-treatment. The effect of thread-embedding therapy against partial obesity was continuous and was most pronounced during the first week. Conclusions : Thread-embedding therapy may be useful to reduce partial obesity without different treatments of obesity, diet, exercise etc.

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Biophysical therapy and biostimulation in unfavorable bony circumstances: adjunctive therapies for osseointegration

  • Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.195-203
    • /
    • 2012
  • Dental implants using titanium have greatly advanced through the improvement of designs and surface treatments. Nonetheless, the anatomical limits and physiological changes of the patient are still regarded as obstacles in increasing the success rate of implants further, even with the enhancement of implant products. So there have been many efforts to overcome these limits. The intrinsic potential for bone regeneration can be stimulated through adjuvant treatments with the continuous improvement of implant properties, and this can play an important role in achieving optimum osseointegration toward peripheral bone tissue and securing ultimate long-term implant stability in standard surgical procedures. For this purpose, various chemical, biological, or biophysical measures were developed such as bone grafts, materials, pharmacological agents, growth factors, and bone formation proteins. The biophysical stimulation of bone union includes non-invasive and safe methods. In the beginning, it was developed as a method to enhance the healing of fractures, but later evolved into Pulsed Electromagnetic Field, Low-Intensity Pulsed Ultrasound, and Low-Level Laser Therapy. Their beneficial effects were confirmed in many studies. This study sought to examine bone-implant union and its latest trend as well as the biophysical stimulation method to enhance the union. In particular, this study suggested the enhancement of the function of cells and tissues under a disadvantageous bone metabolism environment through such adjunctive stimulation. This study is expected to serve as a treatment guideline for implant-bone union under unfavorable circumstances caused by systemic diseases hampering bone metabolism or the host environment.

Design of Ultrasound Dynamic Focusing Systems (초음파 다이나믹 집속 시스템의 설계)

  • 김진하;김청월
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.4
    • /
    • pp.65-71
    • /
    • 1984
  • The design formular of optical focusing systems cannot be applied to ultrasonic B scanners, which use broadband pulses instead of continuous wave. In this paper, a calculation method is studied for analyzing the propagation of ultrasonic broadband pulse excited by ultrasonic array transducers. Using the results, seveial design parameters such as the number of transducer elements, delay time, and the focal point are determined to obtain high resolution in the ultrasonic dynamic focusing system. A dynamic focusing system with low-noise switching characteristics; which attains lateral resolution of 2-3mm all along the axial direction up to 18 cm with a 3.5 MHz linear array transducer, was implemented.

  • PDF

Successful treatment of a bowel fistula in the open abdomen by perforator flaps and an aponeurosis plug

  • Sashida, Yasunori;Kayo, Munefumi;Hachiman, Hironobu;Hori, Kazuki;Kanda, Yukihiro;Nagoya, Akihiro
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.375-378
    • /
    • 2018
  • In this report, we present a case of successful treatment of a bowel fistula in the open abdomen by perforator flaps and an aponeurosis plug. A 70-year-old man underwent total gastrectomy and developed anastomotic leakage and dehiscence of the abdominal wound a week later. He was dependent upon extracorporeal membrane oxygenation, continuous hemodiafiltration, and a respirator. Bowel fluids contaminated the open abdomen. Two months after the gastric operation, a plastic surgery team, in consultation with general surgeons, performed perforator flaps on both sides and constructed, as it were, a bridge of skin sealing the orifice of the fistula. The aponeurosis of the external oblique muscle was elevated with the flap to be used as a plug. The perforators of the flaps were identified on preoperative and intraoperative ultrasonography. This modality allowed us to locate the perforators precisely and to evaluate the perforators by assessing their diameters and performing a waveform analysis. The contamination decreased dramatically afterwards. The bare areas were gradually covered by skin grafts. The fistula was closed completely 18 days after the perforator flap. An ultrasound-guided perforator flap with an aponeurosis plug can be an option for patients suffering from an open abdomen with a bowel fistula.

Analysis of Twinkling Artifacts Caused by Kidney Stones on Abdominal Ultrasound (복부 초음파 검사에서 신장결석으로 인해 발생되는 Twinkling 인공물에 관한 분석)

  • Kim, Ju-Hee;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.637-642
    • /
    • 2021
  • Kidney stones are largely classified into kidney stones, ureter stones, and urolithiasis depending on the location of their occurrence. Therefore, in this study, from January 2019 to June 2021, kidney stones found in 112 patients with flank pain or who visited for abdominal ultrasonography at a general hospital located in Daegu were diagnosed with urolithiasis. We wanted to investigate the effect on twinkling artifacts. As a result of the study, the incidence of twinkling artifacts due to kidney stones was relatively high in the longitudinal scan among the scan methods. As the number of kidney stones increased, the incidence of twinkling artifacts increased by 1.296 times (p<0.05). As the kidney stone size increased, the incidence of twinkling artifacts increased by 0.086-fold (p<0.05). It was found that the number and size of kidney stones are factors affecting twinkling artifacts. Since the effect of kidney stones on twinkling artifacts is related to the number and size of kidney stones, continuous attention should be paid to helping the detection of kidney stones by using variables affecting twinkling artifacts.