• 제목/요약/키워드: Continuous ice making

검색결과 14건 처리시간 0.031초

제어압력 및 수용액의 농도가 관내 연속제빙에 미치는 영향 (Influence of Control Pressure and Concentration of Water Solution at Continuous Ice Making in a Tube)

  • 박기원;오후규
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1236-1244
    • /
    • 2001
  • In the present study, the possibility of continuous slurry ice making using flowing water solution in a cooled tube has been investigated. The experiments were carried out at various concentration and velocity of water solution, temperature of cooled tube wall, and control pressure in a tube. As a result, four types of operating conditions, that is super-cooling, continuous ice making, intermittent ice making and ice blockage, were classified. And it was found that the critical condition for the continuous ice making was acquired as a function of these experimental parameters.

  • PDF

수평냉각관내에서 유동하는 유기수용액의 제빙형태 (Ice Marking Pattern of Flowing Organic Water Solution in a Horizontal Cooled Tube)

  • 박기원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권5호
    • /
    • pp.52-57
    • /
    • 2000
  • Recently large capacity of electric equipment and increasing in atomic power generation are shown. One of the reason is shortage of the electric power supply for air conditioning load during summer. And every consumer is concerning about economical refrigeration and air conditioning system to decreases electric power consumption and decrease in global warming. For these necessities, ice making thermal storage system is required. Therefore, in this paper, the possibility of continuous slurry ice making using flowing organic water solution in cooled circular tube has been investigated. The experiments was carried out under some parameters of concentration and velocity of water solution, temperature of cooled tube wall, and control pressure in tube, As a result, four types of operating conditions in the pipe, that was supercooling, continuous ice making, intermittent ice making and ice blockage, were classified . And it was found that the critical condition for continuous ice making was acquired as a function of these experimental parameters.

  • PDF

가압 판형 열교환기에 의한 수용액의 아이스슬러리 생성 (Ice Slurry Formation of a Solution in a Pressurized Plate Heat Exchanger)

  • 이동규;김병선;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.596-602
    • /
    • 2006
  • Ice adhesion and blockage problems have been issued in continuous ice slurry making process. So we composed continuous ice slurry making device using a commercial small plate heat exchanger (PHX), and investigated character of ice formation. An experiment of ice formation was peformed with an aqueous solution of ethylene glycol 7 mass%. In the experiment, the effect of the pressurization on ice slurry formation during the cooling process was investigated. The pressurization test for the aqueous solution was performed by setting valves at the PHX inlet and outlet. At the results, the time of continuous ice formation increased as the pressure of the plate heat exchanger increased for cooling temperature of $-5^{\circ}C$. Also continuous ice formation at the cooling temperature of $-7^{\circ}C$ showed a possibility. It was found that the pressurization may contribute to suppress the dissolution of supercooled aqueous solution in the PHX.

자성유체를 이용한 다이나믹형 빙축열 시스템에 관한 실험적 연구 (An Experimental Study of Dynamic Type Ice Storage System Using Magneticfluid)

  • 황승식
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1484-1493
    • /
    • 2004
  • In this study, it induced to a conclusion below by experiment consideration to regarding an effective supercooling ends method of the flow cooling water in a tube of continuous ice making method and the static cooling water in a tube of continuous ice making method which used magneticfluid in a dynamic type ice storage system. Continuous ice making in a tube of the flow cooling water was shortened about 12 minutes until supercooling ends that case which gave vertical eccentricity rotation magnetic field 120rpm than did not provide magnetic field by experimental result that was tested to supercooling ends effect from shape control of magneticfluid. Continuous ice making method in a tube of the static cooling water compared with and reviewed the case that was not provided with the magnetic field and exposed cooling surface instantaneously by magnetic field. It confirmed that supercooling degree $\Delta$ $T_{c}$, $\Delta$ $T_{s}$, and $\Delta$ $T_{w}$ became lower because of heat transfering increasing by the occurrence of natural convection between after cooling starting progress time 1∼3 minutes if it did not give a magnetic field, and peformed the supercooling ends when natural convection occurred confirmed that refrigerating capacity was better. That relation $\Delta$ $T_{c}$, and $t_{e}$/($\Delta$ $T_{c}$-$\Delta$ $T_{s}$) after convection occurred, was not depended on $T_{b}$ and initial temperature if the depth of water and thickness of magneticfluid were regular and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.lar and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.c}$.>.

판형 열교환기를 이용한 과냉각수용액에서 유동과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Influence of the Supercooling Degree and Cooling Rate on a Continuous Ice Formation by a Supercooled Aqueous Solution in Flow Using a Plate Heat Exchanger)

  • 이동규;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.647-653
    • /
    • 2007
  • In dynamic ice storage system(DISS), ice slurry is formed not only from solution freezing by mechanical removing parts but also supercooled solution. However, in order to perform continuous ice formation in the system without mechanical moving parts, supercooled aqueous solution should be formed stable through cooling heat exchanger and be dissolved uniformly in storage tank. In previous study, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger)

  • 이동규;백종현;홍희기;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF

자성유체를 이용한 빙축열 시스템에서의 과냉각 유제에 관한 실험적 연구 (An Experimental Study of Undercooling Ends in the Ice Storage System Using Magneticfluid)

  • 이희상;전운학;이봉규;김중;황승식
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.143-149
    • /
    • 1999
  • In this study , the new method which is used by magneticfluid for undercooling ends and continuous ice making is introduced to ice making in the ice stroage system and its validity is studied experimentally . This study made sure how shape control of magniticfluid and instant explosure method can effect on the undercooling degree and it exchange by time change at the moments of undercooling ends and acquired the fundamental knowledge for control method about undercooling ends.

  • PDF

냉각면 성상이 빙부착에 미치는 영향 (Effect on the Adhesion of Ice Slurry by the Characteristic of Cooling Surface)

  • 승현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.183-190
    • /
    • 2005
  • In the process of ice-slurry making, ice adhesion on cooling wall or in narrow flow Path disturbs continuous ice formation. In this study, the effect on the ice adhesion to cooling surface by some freezing experiments was investigated, quantitatively. Three types of solutions were frozen in various coating vessels with stirring. In the experiment, the ice adhesion between cooling wall and Ice-slurry was evaluated by measuring stirring power. From the result, the stirring power of slurry mixture in PTFE-coating vessel was smaller than those in PE-coating, PFA-coating and bare SUS vessel. Especially, in EG H PG 1.S/ HD 1.5 mass$\%$ solution, the stirring power in the PE-coating vessel was smaller than that in the PFA-coating or SUS vessel.

유기수용액에 의한 냉각관내 연속제빙시의 제빙량 (Quantity of Ice Slurry in Cooled Tube by Continuous Ice Making using Organic Water Solution)

  • 박기원
    • 에너지공학
    • /
    • 제9권3호
    • /
    • pp.221-227
    • /
    • 2000
  • 본 논문은 냉각된 원관내에서 유동하는 프로필렌글리콜 수용액의 제빙에 관하여 실험한 것이다. 실험은 수용액의 질량농도, 수용액의 유속, 관벽의 온도, 펌프의 압력 등을 변화시키면서 행하였다. 그 결과 관내에서의 제빙량은 프로필렌글리콜 수용액의 관내유속, 벽면과 냉각도 및 수용액의 농도에 영향을 받고 있었고, 수용액의 질량농도가 낮을수록 또 시험수용액의 유속이 빠를수록 관내에서의 제빙량은 증가하는 경향을 띄었다. 그리고 관내제빙율에 영향을 미치는 인자들의 효과를 검토하여 관내제빙율에 관한 우차원식을 얻었다.

  • PDF

축냉 시스템을 적용한 쇼케이스 운전에 대한 실험적 연구 (Experimental Study of Showcase Using Cold Storage System)

  • 이은지;이동원;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1111-1116
    • /
    • 2008
  • The purpose of this study is to maintain high efficiency and reasonable use of cold-heat storage systems operated the showcase. An experimental study is carried out to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that at the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling.

  • PDF