• 제목/요약/키워드: Continuous heating system

검색결과 85건 처리시간 0.03초

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

A 2.4 GHz-Band 100 W GaN-HEMT High-Efficiency Power Amplifier for Microwave Heating

  • Nakatani, Keigo;Ishizaki, Toshio
    • Journal of electromagnetic engineering and science
    • /
    • 제15권2호
    • /
    • pp.82-88
    • /
    • 2015
  • The magnetron, a vacuum tube, is currently the usual high-power microwave power source used for microwave heating. However, the oscillating frequency and output power are unstable and noisy due to the low quality of the high-voltage power supply and low Q of the oscillation circuit. A heating system with enhanced reliability and the capability for control of chemical reactions is desired, because microwave absorption efficiency differs greatly depending on the object being heated. Recent studies on microwave high-efficiency power amplifiers have used harmonic processing techniques, such as class-F and inverse class-F. The present study describes a high-efficiency 100 W GaN-HEMT amplifier that uses a harmonic processing technique that shapes the current and voltage waveforms to improve efficiency. The fabricated GaN power amplifier obtained an output power of 50.4 dBm, a drain efficiency of 72.9%, and a power added efficiency (PAE) of 64.0% at 2.45 GHz for continuous wave operation. A prototype microwave heating system was also developed using this GaN power amplifier. Microwaves totaling 400 W are fed from patch antennas mounted on the top and bottom of the microwave chamber. Preliminary heating experiments with this system have just been initiated.

PCB-BOARD의 방열기 발열특성 해석 (Heat Characteristics Analysis of Radiator for PCB-Board)

  • 장성철;권민수;한수민
    • 동력기계공학회지
    • /
    • 제20권6호
    • /
    • pp.20-26
    • /
    • 2016
  • For power electronic devices, the thermal energy density per unit volume has seen a rapid increase in recent years, owing to the miniaturization and dense integration of electronic components, as well as the continuous development in performance and function. This research examined the validity and reliability of a thermal safety model for managing the heating conditions of TRIAC electronic components. Among the electronic components of a PCB, these can be considered as a heat source. Using the model, the heating conditions of TRIAC components were maintained at their design target levels in the process of developing an LMT motor drive board. In addition, the heating characteristics of the entire PCB were analyzed to verify its thermal safety. Finally, the reliability and validity of the thermal safety model for maintaining the heating conditions of the TRIAC electronic elements at adequate levels was verified using a numerical analysis method.

유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계 (Design of New Current Full-Bridge Resonant Inverter for Induction Heating System)

  • 이상훈;임상길;송성근
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

태양열과 가스 연소열을 적용한 복합 태양열 흡수기의 열특성 연구 (Thermal Characteristics of Hybrid Solar Receiver using a Solar and Combustion heating)

  • 강명철;김진수;강용혁;윤환기;유창균;이상남
    • 신재생에너지
    • /
    • 제2권4호
    • /
    • pp.33-38
    • /
    • 2006
  • The Dish/Stirling system with the Stirling engine is currently used to convert solar energy directly to electrical energy. Successful operation of dish/Stirling system is supported by hybrid system, which will allow continuous operation driven by solar and combustion heating. The hybrid Receiver has to be provided with an additional combustion system. The heat pipe receiver and conbustion system were manufactured and tested for thermal characteristics of receiver. Maximum temperature difference along the heat pipe surface is $200^{\circ}C$. Emission measurements showed low NOx values of 28 to 46 ppm and very high CO values of 18 to 201 ppm.

  • PDF

미세 패턴 가공을 위한 유도가열 및 수냉식 하이브리드 롤에 대한 기초 연구 (A Basic Study on Induction Heating and Water Cooling System Hybrid Roll for Fine Pattern Processing)

  • 조상현;김병인;손영수;윤동원
    • 한국생산제조학회지
    • /
    • 제22권5호
    • /
    • pp.871-878
    • /
    • 2013
  • Roll-to-roll (R2R) hot embossing systems have been developed and are widely used in various industrial domains. These systems press and heat flexible films between a press roll and a back-up roll, as said films pass through the two rolls. In previous studies, a heating roll was used for heating. However, in this study, a hybrid roll for R2R hot embossing is conceptualized and developed. This R2R system can be used for generating fine patterns on large and continuous films. The hybrid roll of our system can cool and heat the films simultaneously, thus affording greater flexibility in process design. Thermal and structural analyses were performed for developing the hybrid roll. In addition, a hybrid roll was designed based on analytical results. Experiments were conducted for measuring the performance of the developed hybrid roll.

Development of a PLD heater for continuous deposition and growth of superconducting layer

  • Jeongtae Kim;Insung Park;Gwantae Kim;Taekyu Kim;Hongsoo Ha
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권2호
    • /
    • pp.14-18
    • /
    • 2023
  • Superconducting layers deposited on the metal substrate using the pulsed laser deposition process (PLD) play a crucial role in exploring new applications of superconducting wires and enhancing the performance of superconducting devices. In order to improve the superconducting property and increase the throughput of superconducting wire fabricated by pulsed laser deposition, high temperature heating device is needed that provides high temperature stability and strong durability in high oxygen partial pressure environments while minimizing performance degradation caused by surface contamination. In this study, new heating device have been developed for PLD process that deposit and growth the superconducting material continuously on substrate using reel-to-reel transportation apparatus. New heating device is designed and fabricated using iron-chromium-aluminum wire and alumina tube as a heating element and sheath materials, respectively. Heating temperature of the heater was reached over 850 ℃ under 700 mTorr of oxygen partial pressure and is kept for 5 hours. The experimental results confirm the effectiveness of the developed heating device system in maintaining a stable and consistent temperature in PLD. These research findings make significant contributions to the exploration of new applications for superconducting materials and the enhancement of superconducting device performance.

수평형 CGL 소둔로의 연소 및 가열 성능 해석을 위한 오픈소스 OpenFOAM 기반 전산유체 해석 (Application of Open-source OpenFOAM for Simulating Combustion and Heating Performance in Horizontal CGL Furnace)

  • 김군홍;오경택;강덕홍
    • 대한기계학회논문집B
    • /
    • 제41권8호
    • /
    • pp.553-561
    • /
    • 2017
  • 본 연구에서는 산업용 가열 설비에 대한 연소 유동장과 복합 열전달 해석을 위하여 오픈소스 기반의 3차원 해석 시스템을 구축하고 실제 운전 중인 재가열로에 대한 해석을 통해 유용성을 확인하였다. 효율적인 가열로 전용 해석 체계를 위하여 오픈소스 OpenFOAM 라이브러리를 적용함으로써 다양한 해석 기능들을 추가로 개발할 수 있는 확장성과 상용 프로그램 도입에 비하여 경제성 측면에서도 장점들을 가지고 있다. 개발된 프로그램을 활용하여 실제 연속 아연 도금 강판 생산 공정 내의 수평형 소둔로에 대한 해석을 수행하였다. 해석 결과로부터 대상 가열 설비의 가열 성능은 고온 연소 기체에 의한 대류 보다는 복사 열전달 효과가 지배적이며, 이송되는 강판 표면으로 유입되는 복사 열전달량은 총 열전달량의 76% 수준으로 분석되었다. 현 가열로 전용 해석 시스템은 핵심적인 가열 설비 해석 기능을 포함하고 있지만, 다양한 연소 조건에 적용 가능한 난류 연소 모델과 가열로 벽면 열경계에 대한 추가적인 연구가 필요함을 확인하였다.

Cold crucible을 이용한 실리콘의 전자기주조 (Cold Crucible Electromagnetic Casting of Silicon)

  • 신제식;이상목;문병문
    • 한국주조공학회지
    • /
    • 제25권3호
    • /
    • pp.115-122
    • /
    • 2005
  • In the present study, an EMC (Electromagnetic Casting) process, using a segmented Cu cold crucible under a high frequency alternating magnetic field of 20 kHz, was practiced for the fabrication of poly-crystalline Si ingot of 50 mm diameter. The effects of Joule heating and electromagnetic pressure in molten Si were systematically investigated with various processing parameters such as electric current and crucible configuration. A preliminary experimental work was initiated with the pure Al system for the establishment of a stabilized non-contact working condition, and further adapted to the semiconductor-off-grade Si system. A commercialized software such as Opera-3D was utilized in order to simulate electromagnetic pressure and Joule heating. In order to evaluate the meniscus shape of the molten melts, shape parameter was used throughout the research. A segmented graphite crucible, which was attached at the upper part of the cold crucible, was introduced to enhance significantly the heating efficiency of Si melt keeping non-contact condition during continuous melting and casting processes.

에너지절감을 도모하는 실내 온열환경 제어논리-Adaptive Model (New approaches of Indoor Environmental Control for Energy Saving-Adaptive Model)

  • 송두삼;가토 신스케
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.838-846
    • /
    • 2006
  • The purpose of this study to develop the air-conditioning system that adopts adaptive model as an indoor climate control logic for energy saving. The adaptive model using the ability of human thermal adaptation could be expected to alleviate the indoor set-point temperature compared with the past heat-balance model. Especially, in case of hybrid air-conditioning system coupled with natural ventilation and heating/cooling system, the adaptive model can be describe the thermal comfort of inhabitant who stay at hybrid system controlled buildings with accuracy. In this paper, the concept of adaptive model will be described and the results of a continuous measurement on the actual thermal experiences and behaviors of thermal adaptation for office worker will be reported.

  • PDF