• 제목/요약/키워드: Continuous heating system

검색결과 85건 처리시간 0.025초

주거용건물의 바닥복사 난방방식에 대한 실태조사 연구 (Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing')

  • 우병관;이성;김삼열
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.

냉연 연속 소둔로 가열대 판온제어 (Strip temperature control for the heating furnace in the continuous-annealing line)

  • 정호성;유석환;백기남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.779-782
    • /
    • 1990
  • Recently batch type cold rolling processes have been replaced by continuous annealing type processes for cold rolled sheets of mild steel and high strength steel in order to obtain higher productivity, labor saving. In the continuous annealing line, it is very important to maintain the target steel strip temperature at the exit side of each furnace. The automation system of continuous annealing line is based on a hierachical composition. This paper shows how to preset the set value of furnace temperature control for the heating section in a continuous annealing line. Saying in other words, this paper presents the development of an adaptive control approach to control the exit strip temperature in the continuous annealing line. There are three parts in this approach; one is a process modelling and another is recursive parameter estimation and the other is a design of temperature controller.

  • PDF

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

제주도 GDHS의 R&D투자 타당성 분석을 위한 연속적 SDP모형의 개발 및 응용사례연구 (A Continuous Sequential Decision Process Model for R&D Economic Feasibility Assessment of the GDHS in Chejoo Island and Its Application)

  • 양문희;장경
    • 대한산업공학회지
    • /
    • 제24권1호
    • /
    • pp.115-126
    • /
    • 1998
  • A GDHS(Geothermal District Heating System) is a heating system supplying a group of districts with heat extracted from geothermal sources. Due to various advantages of GDHS including the saving of fuel consumption as well as the reduction of air pollution, a world-wide trend is to replace central/individual heating systems with GDH systems. The basic point of this paper is that a crash program mentality leads to inappropriate decisions about policy issues in large-scale research and development like the development of GDHS, R&D funding should be viewed as a sequential decision, not a once-and-for-all choice. Hence we develop on economic feasibility assessment model based on a continuous sequential decision process for the Chejoo Island GDHS Project by modifying Roberts's model.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

FTA를 이용한 볼트 유도가열시스템의 고장 및 전기화재 분석 (Analysis of Failure and Electrical Fire for Bolt Induction Heating System Using FTA)

  • 김두현;김성철;엄한얼;강문수;정천기
    • 한국안전학회지
    • /
    • 제36권4호
    • /
    • pp.12-19
    • /
    • 2021
  • This paper presents a safety assessment method for FTA-based induction heating systems; the failures and causes of electrical fire are first analyzed for each part and module qualitatively, and methods to manage high probabilities of failure and electrical fire are considered, thereby improving the reliability of the induction heating system. The cumulative importance value (ACC) of the minimal cut set is drawn by setting failure as the top event, and STACK and SMPS are observed to account for about 70% of the induction heating system failures. Thus, intensively managing the basic events contained in the minimal cut set of failures for STACK and SMPS is expected to provide effective and stable operation of the induction heating system. When electrical fire is set as the top event, the STACK percentage is 90%. Accordingly, the current IGBT is changed to a FET to increase the applied voltage and prevent induction heating system failure, and a heat sink plane is installed to prevent FET heating caused by switching, thereby preventing an electrical fire. By classifying the parts and modules of the induction heating system in detail and by applying FTA based on actual failure rates and relevant data, more practical and reasonable results may be expected. Hence, continuous research must be conducted to ensure safety when using induction heating systems.

개방된 2상 자연순환 회로내의 유동특성에 관한 실험적 연구 (An Experimental Study on the Flow Characteristics Inside an Open Two-Phase Natural Circulation Loop)

  • 경익수;이상용
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1313-1320
    • /
    • 1993
  • 본 연구에서는 가시화가 가능한 상승부를 가진 개방된2상 자연순환 회로를 설치하여 각 운전 조건에 따른 순환 유동 특성을 살펴보았다. 즉, 가열량 증가에 따 른 상승부에서의 2상 유동 양식의 변화를 관찰하였고 동시에 가열기 입구 과냉 액체의 순환 유속 및 상승부의 기공률(void fraction)을 측정하였다. 또한 가열기 입구 및 출구에 설치된 밸브의 마찰저항, 가열기 입구 액체의 과냉 정도, 그리고 충전수위등이 전반적인 유동특성에 미치는 영향을 연구하였다.

지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토 (Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature)

  • 배상무;전재영;권영식;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.

일본 돔경기장의 냉난방 설비 시스템에 관한 사례연구 (A Case Study on the Cooling and Heating System of Domed Stadiums in Japan)

  • 양정훈;김동우;송두삼
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.109-118
    • /
    • 2007
  • 본 논문은 향후 국내 돔경기장 냉난방 시스템 설계시 고려사항에 대해 고찰하고 있다. 대공간의 실내 온열환경계획은 지속적인 연구와 풍부한 경험을 통한 관련 기술의 축적이 필요한 분야이다. 따라서 다수의 돔경기장을 보유하고 있는 일본을 중심으로 돔경기장에 도입된 최신의 냉난방 설비시스템 사례를 조사하고 요소기술의 분석을 실시하였다. 또한 연구결과는 대공간의 쾌적한 실내온열환경 조성을 위한 냉난방 시스템 계획시의 기초 자료로 활용하고자 한다.

  • PDF

바닥 난방공간의 다인자 제어에 관한 실험적 연구 (An experimental study on the multiple parameter switching control for floor heating system)

  • 조성환;태춘섭;장철용
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF