• 제목/요약/키워드: Continuous flow experiments

검색결과 128건 처리시간 0.033초

영가철 충진 복극전해조를 이용한 질산성질소 및 대장균의 연속식 제거 (Continuous Removal of Nitrate and Coliform using Bipolar ZVI Packed Bed Electrolytic Cell)

  • 정주영;박정호;최원호;박주양
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.651-658
    • /
    • 2011
  • Nitrate is a common contaminant in industrial wastewater and ground water. The maximum contaminant level set by EPA for nitrate of 10 mg/L as N. In this study, nitrate was removed using bipolar ZVI packed bed electrolytic cell that maximized the contact area between each electrode and contaminants under 600 V. Also this study investigates the simultaneously deals with removal of ammonia by operating air stripping tower. In addition to the air stripping also helped to precipitate iron ions to the form of iron oxides. Bipolar ZVI packed bed electrolytic cell was also effective in removing coliform by electrical power. In the continuous experiments for the simulated wastewater (initial nitrate for 25 mg/L as N), maximum 96.3% removal of nitrate was achieved in the applied 600 V at the flow rate of 6 mL/min.

Modeling of continuous diffusion dialysis of aqueous solutions of sulphuric acid and nickel sulphate

  • Bendova, Helena;Palaty, Zdenek
    • Membrane and Water Treatment
    • /
    • 제2권4호
    • /
    • pp.267-279
    • /
    • 2011
  • At steady state, the simultaneous transport of sulphuric acid and nickel sulphate through an anion-exchange membrane Neosepta-AFN (Astom Corporation, Tokyo, Japan) was investigated in a two-compartment counter-current dialyzer with single passes. The transport was quantified by the recovery yield of acid, rejection of salt and four phenomenological coefficients, which were correlated with the acid and salt concentrations in the feed. The phenomenological coefficients were determined by the numerical integration of the basic differential equations describing the concentration profiles of the components in the dialyzer. This integration was combined with an optimizing procedure. The experiments proved that the acid recovery yield is in the limits from 63 to 91 %, while salt rejection is in the limits from 79 to 97 % in the dependence on the volumetric liquid flow rate and composition of the feed.

두 연속 터널을 전파하는 압축파의 실험적 연구 (Experimental study of compression waves propagating into two-continuous tunnels)

  • 김희동;허남건
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1294-1302
    • /
    • 1997
  • For the purpose of investigating the impulsive noise at the exit of high-speed railway tunnel and the pressure transients inside the tunnel, experiments were carried out using a shock tube with an open end. A great deal of experimental data were obtained and explored to analyze the peak pressures and maximum pressure gradients in the pressure waves. The effects of the distance and cross-sectional area ratio between two-continuous tunnels on the characteristics of the pressure waves were investigated. The peak pressure inside the second tunnel decreases for the distance and cross-sectional area ratio between two tunnels to increase. Also the peak pressure and maximum pressure gradient of the pressure wave inside the second tunnel increase as the maximum pressure gradient of initial compression wave increases.

크랭크케이스 강제 환기 밸브의 최적설계에 관한 연구 (A Study on the Optimal Design for a Positive Crankcase Ventilation valve)

  • 이종훈;이연원;김재환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.197-201
    • /
    • 2005
  • According to operating conditions of each engine, a PCV valve has various flow rates and pressure characteristic. In a developed country, it has been developing by a computational design simulation. But, Korean companies have no ability of technical design for a PCV valve. So, they depend on their experiments and copy the designs of foreign companies when they need to design new PCV valves. These problems cause increase of error rate and take much time. Hence, optimal design for a PCV valve is needed to secure for continuous competition against foreign automobile companies. In this study, we used 4th order Runge-Kutta method for the prediction of spool movements and applied Bernoulli's equation for the determination of flow area. A spool geometry and spool displacement were predicted to be satisfied in comparison with their experiment.

  • PDF

알루미늄입자의 유체화, 이송 및 점화에 대한 연구(I) (Development of aluminum powder feeding system)

  • 이선기;권수현;이병준;송동주;이지형
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.241-243
    • /
    • 2012
  • Experiments were conducted to get the design concepts for the continuous aluminum particle feeding system. Two opposed cylinders were used. Aluminum particles in one cylinder were ejected to the air by the supplying gas and the pressure of the other cylinder. It was not possible to eject more aluminum mass flowrate than that of gas if particles were just thrust by the pressure difference between two cylinders. Aluminum particle/air mixture in the flow system was successfully ignited by the electric spark.

  • PDF

알루미늄 원통컵의 스피닝 성형성에 영향미치는 작업조건 연구 (Influence of Working Conditions on the Spinnability of Cylindrical Cups of Aluminum Sheet Metal)

  • 김종호;박규호;나경환;김승수
    • 소성∙가공
    • /
    • 제8권5호
    • /
    • pp.465-470
    • /
    • 1999
  • Many researchers have, nowadays, studied on spinning which can produce highly qualified products by CNC spinning machine equipped with hydraulic devices. The products have continuous metal flow which improves fatigue life, yield point, tensile strength and hardness. This study is to investigate the influence of various working conditions on the spinnability of cylindrical cups such as feed rate(ν), feed pitch(p), angle of roller holder(α), and the inclination angle of first roller path. Through experiments the feed rate of (0.4∼0.7) mm/rev was shown to give the drawing ratio of 2.5 when the angle of roller holder was 5°, However, by increasing the angle of roller holder from 5°to 20°, the range of feed rate which can produce deeper cups became wider and the spinnability was also improved. The optimum working conditions, for the maximum formability of aluminum sheet metal as well as dimensional accuracy of spun cups, are presented and discussed.

  • PDF

Biosorption of Cr (VI) ions by Ficus religiosa barks: Batch and continuous study

  • Karthick, S;Palani, R;Sivakumar, D;Meyyappan, N
    • Membrane and Water Treatment
    • /
    • 제13권5호
    • /
    • pp.209-217
    • /
    • 2022
  • In the present research, Ficus religiosa Bark (FRB) is used as an adsorbent for the removal of heavy metal Cr (VI) ions. This Ficus religiosa Bark was characterized by Scanning Electron Microscope, Fourier transform infrared Spectroscopy, Thermo Gravimetric Analyzer and the results showed that activated adsorbent have high adsorption capacity and withstand even in high temperature. Batch and Continuous experiments were conducted to determine the effect of various parameters such as pH, contact time, adsorbent dose and initial metal concentration. The biosorption followed pseudo first order kinetic model. The adsorption isotherms of Cr (VI) on Ficus religiosa fitted well with the Temkin model. In Batch study, maximum biosorption capacity of Cr (VI) was found to be 37.97 mg g-1 (at optimal pH of 2, adsorbent dosage of 0.3 grams and concentration of Cr (VI) is100 mg L-1). The Continuous mode of study shows that 97% of Cr (VI) ion removal at a flow rate of 15 ml min-1. From the results, selected Ficus religiosa Bark has the higher adsorption capacity for the removal of Cr (VI) ions from wastewater.

전산유체역학을 활용한 폐플라스틱열분해 반응기의 기체분산판에 대한 유동해석 (Effects of Thermal Dispersion Damage on the Pyrolysis and Reactor Relarionship Using Comutational Fluids Dynamics)

  • 한종일;박성수;김인재;나광호
    • 신재생에너지
    • /
    • 제19권4호
    • /
    • pp.53-60
    • /
    • 2023
  • The Computational Fluid Dynamics (CFD) model is a method of studying the flow phenomenon of fluid using a computer and finding partial differential equations that dominate processes such as heat dispersion through numerical analysis. Through CFD, a lot of information about flow disorders such as speed, pressure, density, and concentration can be obtained, and it is used in various fields from energy and aircraft design to weather prediction and environmental modeling. The simulation used for fluid analysis in this study utilized Gexcon's (FLACS) CODE, such as Norway, through overseas journals, for the accuracy of the analysis results through many experiments. It was analyzed that a technology for treating two or more catalysts with physical properties under low-temperature atmospheric pressure conditions could not be found in the prior art. Therefore, it would be desirable to establish a continuous plan by reinforcing data that can prove the effectiveness of producing efficient synthetic oil (renewable oil) through the application that pyrolysis under low-temperature and atmospheric pressure conditions.

Synthesis of Precipitated Calcium carbonate in Ca(OH)2-CO2-H2O System by the Continuous Drop Method of Ca(OH)2 Slurry

  • Ahn, Ji-Whan;Lee, Jae-Sung;Joo, Sung-Min;Kim, Hyung-Seok;Kim, Jong-Kuk;Han, Choon;Kim, Hwan
    • 한국세라믹학회지
    • /
    • 제39권4호
    • /
    • pp.327-335
    • /
    • 2002
  • Experiments were conducted to investigate the synthesis characteristics of Precipitated Calcium Carbonate(for short PCC) in Ca(OH)$_2-CO_2-H_2O$ system by the continuous drop method of Ca(OH)$_2$ slurry into the solution containing $CO_2$(aq). When the flow rate of $CO_2$(g) increases and the concentration of Ca(OH)$_2$ slurry become low, the absorption rate of $CO_2$(g) become faster than the dissolution rate of Ca(OH)$_2$. Consequently, the growth of the calcite crystal plane is facilitated resulting in synthesis of $1.0{\mu}m$ of rhombohedral calcite. On the other hand, when the flow rate of $CO_2$(g) decreases and the concentration of Ca(OH)$_2-CO_2-H_2O$ slurry become high, new nuclei is created along with the crystal growth resulting in synthesis of $0.1{\mu}m$ of prismatic calcite. Maintaining 1.0wt% of Ca(OH)$_2-CO_2-H_2O$ slurry, 120 drops/min of drop rate and $25^{circ}C$ of temperature, the shape of PCC shows colloidal and spherical agglomerate at 100 mL/min of the flow rate of $CO_2$(g); the mixture of rhombohedral and plate-shaped calcite, at 200∼500 mL/min. Therefore, as the flow rate of $CO_2$(g) increases, the shape of PCC changes from colloidal and rhombohedral calcite to plate-shaped calcite. Maintaining 500 mL/min of the flow rate of $CO_2$(g), 120 drops/min of the drop rate of Ca(OH)$_2$ slurry, and $25^{circ}C$ of temperature, the shape of PCC shows the plate-shaped calcite at 1.0∼3.0 wt% of Ca(OH)$_2$ slurry; the hexagonal plate-shape calcite of the thickness of $0.1{\mu}m$ and the width of $1.0{\mu}m$, at 4.0 wt%.

온도 변화에 따른 수돗물 저장 저수조 내 잔류염소에 관한 수학적 모형 시뮬레이션 (Mathematical Model Simulations Assessing the Effects of Temperature on Residual Chlorine Concentrations in Water Storage Tanks)

  • 노유래;박준홍
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.187-196
    • /
    • 2017
  • To ensure hygienic safety of drinking water in a water storage tank, the concentrations of residual chlorine should be above a certain regulation level. In this study, we conducted model simulations to investigate the effects of temperature on residual chlorine in water storage tank conditions typically used in Seoul. For this, values of model parameters (decomposition rate constant, sorption coefficient, and evaporation mass transfer coefficient) were experimentally determined from laboratory experiments. The model simulations under continuous flow conditions showed that the residual chlorine concentrations were satisfied the water quality standard level (0.1 mg/L) at all the temperature conditions ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$). Meanwhile, when the tanks had a no flow condition (i.e., no tap-water influent due to a sudden shut-down), the concentrations became lower than the regulatory level after certain periods. The findings from this modeling works simulating Seoul's water storage tanks suggested disappearance rate of residual chlorine could be reduced through the tanks design optimization with maintenance of low water temperature, minimization of air flow and volume, suppression of dispersion and the use of wall materials with low sorption ability.