• Title/Summary/Keyword: Continuous Scanning

Search Result 241, Processing Time 0.032 seconds

Surface removal of stainless steel using a single-mode continuous wave fiber laser to decontaminate primary circuits

  • Song, Ki-Hee;Shin, Jae Sung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3293-3298
    • /
    • 2022
  • Removing radioactive contaminated metal materials is a vital task during the decommissioning of nuclear power plants to reduce the cost of the post-dismantling process. The laser decontamination technique has been recognized as a key tool for a successful dismantling process as it enables a remote operation in radioactive facilities. It also minimizes exposure of workers to hazardous materials and reduces secondary waste, increasing the environmental friendless of the post-dismantling processing. In this work, we present a thorough and efficient laser decontamination approach using a single-mode continuous-wave (CW) laser. We subjected stainless steels to a surface-removal process that repetitively exposes the laser to a confined region of ~75 ㎛ at a high scanning rate of 10 m/s. We evaluate the decontamination performance by measuring the removal depth with a 3D scanning microscope and further investigate optimal removal conditions given practical parameters such as the laser power and scan properties. We successfully removed the metal surface to a depth of more than 40 ㎛ with laser power of 300 W and ten scans, showing the potential to achieve an extremely high DF more than 1000 by simply increasing the number of scans and the laser power for the decontamination of primary circuits.

Morphology of Silk Fibroin/Poly(vinyl alcohol) Blend Film (견피브로인/Poly(vinyl alcohol) 브렌드 필름의 형태학적 구조)

  • 엄인철;박영환
    • Journal of Sericultural and Entomological Science
    • /
    • v.40 no.2
    • /
    • pp.169-175
    • /
    • 1998
  • The morphology of silk fibroin/poly(vinyl alcohol)(PVA)blend films was investigated using optical microscopy and confocal laser scanning microscopy. The effects of blend ratio and molecular weight of silk fibroin and PVA on phase separation were studied. Macro-phase separation occurred for the silk fibroin-rich/poor region whereas micro-phase separation took place for the dispersed/continuous phase, In spite of differences in molecular weight and blend ratio, it is observed that the dispersed phase and continuous one are composed of silk fibroin and PVA component, respectively. As the molecular weight of silk fibroin and silk fibroin content in blend ratio are decreased, the compatibility of blend is increased due to the reduction of micro-phase separation.

  • PDF

STUDY OF PATENCY RATE IN VARIABLE MICROVASCULAR ANASTOMOSIS (다양한 방법으로 적용한 미세혈관문합술간의 개존율연구)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.5
    • /
    • pp.349-357
    • /
    • 2003
  • Several microvascular anastomotic techniques have been described with methodical effectiveness, patency rates, healing state of microscopic findings. This experimental study presents the comparison of three types of arterial microvascular anastomotic techniques: end-to-end(ETE) anastomosis, end-in-end(EIE) anastomosis, and continuous technique. Sixty male Sprague-Dawley rats, 60 femoral arteries were used for this study. Twenty rats per each technique were used and sacrificed at post-operation 1 day, 3 days, a week, 2 weeks for scanning electromicroscopic findings. The patency was monitored by miniDoppler throughout total experimental periods. The anastomotic time on each method was measured to compare the technical effectiveness. The final results were as follows: 1. The anastomotic time for the end-in-end technique was significantly shorter than another techniques. The average time for each technique was measured as 15 minutes on EIE technique, 20 minutes on continuous technique and 25 minutes on ETE technique. 2. The patency rate for the end-in-end technique at 2 weeks also was superior to another techniques. The patency rate for each technique was demonstrated as 90 % on EIE technique, 85 % on ETE technique and 80 % on continuous technique. 3. The scanning electromicroscopic findings on healing condition of vessel endothelium during the observation period showed that the end results of EIE technique, ETE technique and continuous technique in sequence were good. The end-in-end technique proved to be the superior with regard to anastomotic time and patency rate when compared to end-to-end technuqe, so EIE techniqe might be well available for the case of large discrepancy of vessel size. The patency rate, microscopic healing findings in continuous technique were seen as the lowest level among the three anastomotic techniques, therefore the application of continuous technique was recommended only on the inevitable case.

The Evaluation of Accuracy for Airborne Laser Surveying via LiDAR System Calibration (시스템 초기화(Calibration)에 따른 항공레이저측량의 정확도 평가)

  • 이대희;위광재;김승용;김갑진;이재원
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.15-26
    • /
    • 2004
  • The calibration for systematic error in LiDAR is crucial for the accuracy of airborne laser scanning. The main error is the misalignment of platforms between INS(Inertial Navigation System) and Laser scanner For planimetrical calibration of LiDAR, the building is good feature which has great changes in height and continuous flat area in the top. The planimetry error(pitch, roll) is corrected by adjustment of height which is calculated from comparing ground control points(GCP) of building to laser scanning data. We can know scale correction of laser range by the comparison of LiDAR data and GCP is arranged at the end of scan angle where maximize the height error. The area for scale calibration have to be large flat and have almost same elevation. At 1000m for average flying height, The Accuracy of laser scanning data using LiDAR is within 110cm in height and ${\pm}$50cm in planmetry so we can use laser scanning data for generating 3D terrain surface, expecically digital surface model(DSM) which is difficult to measure by aerial photogrammetry in forest, coast, urban area of high buildings

  • PDF

Development of Large-area Two-photon Stereolithography Process for the Fabrication of Large Three-dimensional Microstructures (대면적 3 차원 마이크로 형상제작을 위한 스테이지 스캐닝 시스템을 이용한 이광자 흡수 광조형 공정 개발)

  • Lim, Tae-Woo;Son, Yong;Yi, Shin-Wook;Kong, Hong-Jin;Park, Sang-Hu;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.122-129
    • /
    • 2008
  • Two-photon stereolithography is recognized as a promising process for the fabrication of three-dimensional (3D) microstructures with 100 nm resolution. Generally, beam-scanning system has been used in the conventional process of two-photon stereolithography, which is limited to the fabrication of micro-prototypes in small area of several tens micrometers. For the applications to 3D high-functional micro-devices, the fabrication area of the process is required to be enlarged. In this paper, large-area two-photon stereolithography (L-TPS) employing stage scanning system has been developed. Continuous scanning method is suggested to improve the fabrication speed and parameter study is conducted. An objective lens of high numerical aperture (N.A.) and high strength material were employed in this system. Through this work, 3D microstructures of $600*600*100\;{\mu}m$ were fabricated.

Scanning Rayleigh Doppler Lidar for Wind Profiling Based on Non-polarized Beam Splitter Cube Optically Contacted FPI

  • Zheng, Jun;Sun, Dongsong;Chen, Tingdi;Zhao, Ruocan;Han, Yuli;Li, Zimu;Zhou, Anran;Zhang, Nannan
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.195-202
    • /
    • 2018
  • A Scanning Rayleigh Doppler lidar for wind profiling based on a non-polarized beam splitter cube optically contacted FPI is developed for wind measurement from high troposphere to low stratosphere in 5-35 km. Non-polarized beam splitter cube optically contacted to the FPI are used for a stable optical receiver. Zero Doppler shift correction is used to correct for laser or FPI frequency jitter and drift and the timing sequence is designed. Stability of the receiver for Doppler shift discrimination is validated by measuring the transmissions of FPI in different days and analyzed the response functions. The maximal relative wind deviation due to the stability of the optical receiver is about 4.1% and the standard deviation of wind velocity is 1.6% due to the stability. Wind measurement comparison experiments were carried out in Jiuquan ($39.741^{\circ}N$, $98.495^{\circ}E$), Gansu province of China in 2015, showing good agreement with radiosonde result data. Continuous wind field observation was performed from October 16th to November 12th and semi-continuous wind field of 19 nights are presented.

Development of An Automated Scanning Laser Doppler Vibrometer for Measurements of In-Plane Structural Vibration (평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구)

  • Kil, Hyun-Gwon
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.231-238
    • /
    • 1997
  • An automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane vibration fields over structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

Morphology and Rheology on the Blends of PLA/CMPS

  • Shin, Boo-Young;Jo, Gyu-Soon;Kang, Kyoung-Su;Lee, Tae-Jin;Kim, Bong-Shik;Lee, Sang-Il;Song, Jeong-Sup
    • Macromolecular Research
    • /
    • v.15 no.4
    • /
    • pp.291-301
    • /
    • 2007
  • The rheological behaviors and morphologies of polylactide (PLA) and chemically modified plasticized starch (CMPS) blends were investigated. For this study, oscillatory shear flow measurements of the PLA, CMPS and their blends were performed. A scanning electron microscope (SEM) study was also conducted on the extracted extrudates of the blends. The morphology of the blend changed in relation to the composition: sphere-shaped CMPS disperse/continuous PLA, rod-like deformed CMPS phase/continuous PLA, a co-continuous structure with bridged CMPS long rods and PLA dispersed/continuous CMPS. The composition of the phase inversion could be estimated and closely coincided from the observed morphology experimental results. The rheological behavior of the blends, from oscillatory measurements, was found to vary in relation to the composition, and reflected the morphologies of the blends. PLA showed Newtonian flow behavior, while CMPS showed strong shear thinning behavior. The relationships between the morphology and rheological properties were observed in detail.

Studies on the Processing Properties and Interactions Between Porcine Blood Proteins and Waxy Rice Starch During Making Porcine Blood Cake

  • Lin, Chin-Wen;Yang, Jeng-Huh;Chu, Hsien-Pin;Su, Ho-Ping;Chen, Hsiao-Ling;Huang, Chia-Cheong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.3
    • /
    • pp.358-364
    • /
    • 2001
  • The physiochemical properties and interactions between porcine blood and waxy rice were determined. Addition of calcium chloride (0.15%) improved acceptability of blood cake and increased the gelatinization degree of waxy rice. The water-holding capacity of porcine blood gel (blood/water=60/40, v/v), extent of absorption and gelatinization of waxy rice, and scanning electron microscopy showed that blood protein matrix and waxy rice are competitors for holding water in the cooking procedure. Non-haem iron content increased linearly (R=0.95) when heating temperature rose. The presence of blood proteins caused increasing of peak temperature (Tp) of gelatinization in differential scanning calorimetric thermal gram, The microstnlcture of plasma proteins and haemoglobin appeared continuous changes, and interacted with surface of waxy rice flour in terms of network and mosaic form, respectively. The electrophoretic patterns revealed an interaction between plasma proteins and waxy rice glutelin and haemoglobin when heated could be found at temperatures above $60^{\circ}C$.

Fabrication of Three-Dimensional Scanning System for Inspection of Massive Sinkhole Disaster Sites (대형 싱크홀 재난 현장 조사용 3차원 형상화 장비 구현)

  • Kim, Soolo;Yoon, Ho-Geun;Kim, Sang-Wook
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.4
    • /
    • pp.341-349
    • /
    • 2020
  • Recently, interest in ground subsidence in urban areas has increased after a large sinkhole occurred near the high-story building area in Jamsil, Seoul, Korea, in 2014. If a massive sinkhole occurs in an urban area, it is crucial to assess its risk rapidly. Access to humans for on-site safety diagnosis may be difficult because of the additional risk of collapse in the disaster area. Generally, inspection using drones equipped with high-speed lidar sensors can be utilized. However, if the sinkhole is created vertically to a depth of 100 m, similar to the sinkhole in Guatemala, the drone cannot be applied because of the wireless communication limit and turbulence inside the sinkhole. In this study, a three-dimensional (3D) scanning system was fabricated and operated using a towed cable in a massive vertical sinkhole to a depth of 200 m. A high-speed lidar sensor was used to obtain a continuous cross-sectional shape at a certain depth. An inertial-measuring unit was applied to compensate for the error owing to the rotation and pendulum movement of the measuring unit. A reconstruction algorithm, including the compensation scheme, was developed. In a vertical hole with a depth of 180 m in the mining area, the fabricated system was applied to scan 0-165 m depth. The reconstructed shape was depicted in a 3D graph.