• Title/Summary/Keyword: Continuous Operation

Search Result 1,708, Processing Time 0.023 seconds

Development of Continuous Capture Test Architecture in the Boundary Scan (경계면스캔에서의 연속캡쳐 시험구조 개발)

  • Jhang, Young-Sig;Lee, Chang-Hee
    • The KIPS Transactions:PartA
    • /
    • v.16A no.2
    • /
    • pp.79-88
    • /
    • 2009
  • In boundary scan architecture, test stimuli are shifted in one at a time and applied to the on-chip system logic. The test results are captured into the BSR and are examined by subsequent shifting. In this paper, we developed a continuous capture test architecture and test procedure using TPG based on boundary scan is used to performance test. In this architecture, test patterns of TPG are applied to CUT with system clock rate, and response of CUT is continuously captured by CBSR(Continuous Capture Boundary Scan Register) at the same rate and the captured results is shifted to TDO at the same rate. The suggested a continuous capture test architecture and test procedure is simulated by Altera Max+Plus 10.0. The simulation results shows the accurate operation and effectiveness of the proposed test architecture and procedure.

A Study on Development of Operation Evaluation Index for Safety Management System Using AHP (AHP를 이용한 안전관리체제 운영평가지표 개발에 관한 연구)

  • Noh, Chang-Kyun;Lee, Jong-In;Shin, Chul-Ho;Kim, Hyung-Geun;Yim, Jeong-Bin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.247-252
    • /
    • 2006
  • In this study, the index for operation evaluation index for safety management system that can be facilitated as the assessment tool for system operation monitoring and operation outcome and the safety management system of shipping companies has been developed. By using this index, this study may provide the instruction or consultation for frequent facilitation by comprehensively recording the required knowledge for each operation stage for the companies that prepares the introduction of the safety management system and companies that already introduced the system to maintain and develop the system. In addition, when working on internal audit and assessing the system operation outcome, it may be facilitated as the assessment tool to contribute in continuous improvement and development. This index is consisted of 11 large categories, 35 items of medium categories and 447 small categories.

  • PDF

Economic Feasibility Analysis for Development of Small Hydropower Using Agricultural Reservoirs (농업용 저수지의 소수력 개발을 위한 경제성 분석)

  • Woo, Jae-Yeoul;Kim, Jin-Soo;Jang, Hoon;Kim, Young-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.2
    • /
    • pp.53-60
    • /
    • 2011
  • This study was conducted to investigate the effect of hydropower factors (watershed, gross head), operation ratio and unit electricity cost on the benefit-cost ratio (B/C ratio) of small hydropower using agricultural reservoirs. The equation of B/C ratio was expressed as a function of watershed area, gross head, operation ratio and unit electricity cost. The benefit increased with watershed area, gross head and unit electricity cost, while the cost increased with watershed area and gross head but decreased with operation ratio. The B/C ratio increased with watershed area, gross head, operation ratio and unit electricity cost. While the effect of gross head on the B/C ratio decreased with watershed area, the effect of operation ratio and unit electricity cost on the B/C ratio increased with watershed area. The operation ratio is an important factor to affect the B/C ratio and therefore we need to develop hydropower for the heightened dams to expect high operation ratio due to continuous water release. The unit electricity cost is also an important factor to affect the B/C ratio and the B/C ratio was always below 1 unless unit electricity cost is over 60 Won/kWh under given conditions. The reservoirs with economic feasibility for small hydropower development were three in 21 when the equation of B/C ratio was appled to the study reservoirs. The results can be used to choose the appropriate reservoir with economic feasibility for development of small hydropower.

A Basic Study on the Development of O&M Cost Assessment Model to Improve Operational Efficiency of Large Public Research Infrastructures (CAM) (대형 공공연구인프라의 운영 효율성 제고를 위한 운영 및 유지관리비 평가모델 개발 기초연구)

  • Choi, Sun-Ah;Son, Seung-Hyun;Lee, Sung-Ho;Oh, Oum-Joong;Han, Bum-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.93-94
    • /
    • 2021
  • The Korean government has invested a tremendous amount of money in the last 10 years to build large public research infrastructures (LPRI). For efficient operation and maintenance of LPRI built with expensive equipment and professional engineers, reasonable budget needs to be allocated. However, it is difficult to fulfill sustainable operation and maintenance (O&M) because there is no standard on budgeting for efficient LPRI operation, including expensive equipment and manpower allocation. There have been a lot of cost assessment studies regarding O&M of high-demand facilities such as hospitals, hotels and residential buildings, but a very few on sustainable O&M of LPRI. Therefore, mid/long-term budget establishment plans for efficient LPRI O&M are required from the initial planning stage and a cost assessment model to support the plans should be developed. The objective of this paper is to propose a cost assessment model for sustainable operation and maintenance of large public research infrastructures. To do so, actual O&M data of 6 LPRI types in operation are collected, and regression analysis model (RAM) is used for development and evaluation a cost assessment model. The study result will support sustainable operation of LPRI from a business perspective and be used as basic data for continuous development of cost assessment models to establish budgets for LPRI operation from an academic perspective.

  • PDF

Clinical Characteristics of Small Bowel Perforation due to Blunt Abdominal Trauma (복부 둔상으로 인한 소장 천공의 임상 양상에 대한 고찰)

  • Bae, Jung-Min
    • Journal of Trauma and Injury
    • /
    • v.24 no.2
    • /
    • pp.125-128
    • /
    • 2011
  • Purpose: Blunt small bowel injury (SBI) is frequently combined other organ injury. So, clinical outcome and characteristics of SBI are influenced by other combined injuries. Thus, we analyzed isolated SBI patients and studied clinical outcome and characteristics. Methods: Between 2005 and 2010, 36 consecutive patients undergoing laparotomy due to isolated SBI were identified in a retrospectively collected. Database. Clinical outcome and characteristics were analyzed. Results: Laparotomy was performed in 36 patients. Primary repair was performed 17 patients. Segmental resection of small bowel was performed 19 patients. Median time gap from trauma to operation was 9 hours. In 24 hours from trauma, operation was performed 31 patients. Post operative death was 5 patients. Mean hospital stay was 18 days and median hospital stay was 12 days. There were significant differences between operation type and minor complication and hospital stay. And there were significant differences between time gap in 24 hours and minor complication. But, there were no significant between time gap and mortality. Conclusion: Although this study had many limitations, some valuable information was produced. When operation above 24 hours was delayed in SBI, minor complications were significantly increased. Segmental resection of small bowel in SBI were significantly increased minor complications and hospital stay. So, preventive measures for surgical site infection was important to reduce wound complication and hospital stay. Further continuous study and multi-center study were should be performed to improve clinical outcome in SBI.

Operational Characteristics of Bride Type SFCL Using Switching Operation of Resistive Type HTSC Element (저항형 고온초전도 소자의 스위칭동작을 이용한 브리지타입 고온초전도 전류제한기의 동작 특성)

  • Lim, Sung-Hun;Park, Chung-Ryul;Lee, Jong-Hwa;Ko, Seok-Cheol;Park, Hyeong-Min;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.83-85
    • /
    • 2004
  • We proposed the bridge type fault current limiter(FCL) using switching operation of high-Tc superconducting(HTSC) thin film. The proposed bridge type FCL consists of HTSC thin film, a diode bridge and a dc reactor. The controller for the operation of an interrupter is required in the conventional bridge type FCL to prevent the continuous increase of fault current after a fault happens. On the other hand, the proposed bridge type FCL can limit the fault current without the interrupter and the controller for its operation by the resistance generated when the gradually increased fault current exceeds HTSC thin film's critical current. We calculated the time when the gradually increased fault current started to be limited by the resistance generated in HTSC thin film after a fault happened and confirmed that it could be dependent on the amplitude of source voltage. The experimental results well agreed with the calculated ones from simulation.

  • PDF

A Study on the Current and Operation Situation of Rural Traditional Theme Community -Case of the Bullat Communitye at Sojun-li in Cheongweon-gun- (농촌 전통테마마을의 현황 및 운영 실태에 대한 사례 연구 -청원군 소전리 벌랏한지마을을 중심으로-)

  • Weon, Se Yong;Park, Jae Pyoung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.9 no.1
    • /
    • pp.51-59
    • /
    • 2007
  • This study is on analyzing of current and operation situation of rural Traditonal Theme Community started from 2002. In this study it analysed result of strength and weakness from the step of selection of plan to the process and operation situation about Bullat Community at Sojun-li in Cheongweon-gun, and suggested improvement method based on the result. First, rural communities have to get peculiar theme for success of green tourism. In spite of the disadvantage as regional conditions for access, the special themes of every communities brought good results about project propulsion. Second, It is need to manage programs which are tour events for short-term, and experience programs for staying all days for increasing income. To make succeed this kind of program, is necessary for giving informations for various visitors such as personal, family and groups. Third, there is need to make continuous programs attracting for four seasons, and operation management having a stable income.

  • PDF

OPERATOR BEHAVIORS OBSERVED IN FOLLOWING EMERGENCY OPERATING PROCEDURE UNDER A SIMULATED EMERGENCY

  • Choi, Sun-Yeong;Park, Jin-Kyun
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.379-386
    • /
    • 2012
  • A symptom-based procedure with a critical safety function monitoring system has been established to reduce the operator's diagnosis and cognitive burden since the Three-Mile Island (TMI) accident. However, it has been reported that a symptom-based procedure also requires an operator's cognitive efforts to cope with off-normal events. This can be caused by mismatches between a static model, an emergency operating procedure (EOP), and a dynamic process, the nature of an ongoing situation. The purpose of this study is to share the evidence of mismatches that may result in an excessive cognitive burden in conducting EOPs. For this purpose, we analyzed simulated emergency operation records and observed some operator behaviors during the EOP operation: continuous steps, improper description, parameter check at a fixed time, decision by information previously obtained, execution complexity, operation by the operator's knowledge, notes and cautions, and a foldout page. Since observations in this study are comparable to the results of an existing study, it is expected that the operational behaviors observed in this study are generic features of operators who have to cope with a dynamic situation using a static procedure.

Parallel-Connected Magnetic Energy Recovery Switch Used as a Continuous Reactive Power Controller

  • Wei, Yewen;Fang, Bo;Kang, Longyun;Huang, Zhizhen;liu, Teguo
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1494-1503
    • /
    • 2016
  • Power quality promotion has received increasing attention because of the wide use of semiconductor devices in recent decades. Reactive power regulation is crucial to ensuring the stable operation of power systems. In this study, a continuous reactive power controller, which is referred to as a parallel-connected magnetic energy recovery switch (MERS), is developed to regulate voltage or power factor in power grids. First, the operating principle is introduced, and a mathematical model is built. Second, a new control method for restraining current harmonics and the peak voltages of capacitors is presented. Using the proposed method, the MERS shows a wide range in terms of reactive power compensation. Finally, the performance of the proposed controller is demonstrated through computer simulations and experiments. Unlike STATCOMs, the proposed controller entails low losses, adopts a small dc capacitor, and offers ease of use.

A basic study on the improvement of the continuous type fishing system for largehead hairtail hand line in coastal area of Jeju island, Korea (제주도 연안 연속식 갈치채낚기 조획시스템의 개량에 관한 기초적 연구)

  • Kim, Byung-Yeob;Lee, Chang-Heon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • This experimental study was carried out to obtain the base data for saving the man power in the fishing operation of largehead hairtail hand line by using the continuous type hand line system with a rotary device which could make a main line move automatically. In order to solve the twists and entangling on the main line happened during operating test, the resistance board was suspended at the end of the main line at sea. As the result, there were no problems of tangling and so on due to up and down moving of a main line. According to the control of a fixed angle of guide roller, it was possible to prevent the main line to be separated from a side roller and a guide roller. In addition, PVC tube between a guide roller and a side roller enabled a main line to be moved smoothly without any entanglement.