• Title/Summary/Keyword: Continuous Motion Effect

Search Result 88, Processing Time 0.028 seconds

The Relationship Between Electroencephalogram Response and Health Promoting Behavior by Applying Eight-Week Motionbeat Exercise to Obese Women (비만여성들의 8주간 모션비트 리듬운동 적용에 따른 뇌파반응과 건강증진행위의 관계)

  • Shin, Hye-Sun;Lee, Jong-Min;Seo, Su-Yeun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.400-411
    • /
    • 2017
  • This study aimed to maximize the effectiveness of motionbeat rhythm exercise on obese women and its applicability in all fields of sports. In addition, this study aimed to propose a plan to promote continuous exercise for people to incorporate as a means to improve healthy lifestyle. The results showed several effects of EEG on health promoting behaviors. Electroencephalogram (Alpha Power) of the left prefrontal cortex showed to have a significant effect on health promotion activities, with respect to stress management, in the motion beat rhythm exercise group. Considering all research findings, we found that the 8-week motion beat exercise can be used as an appropriate and effective social sport program for overweight women as it brings forth positive changes in the prefrontal cortex that maximizes the pleasantness of and interest in health promotion activities relating to stress management. Moreover, we suggest that it can be a method to create an environment for overweight people to continuously participate in exercises by providing results from fun and relaxingactivities, rather than just creating simple physical effects.

ANALYSIS OF CLINICAL EFFECT OF $CO_2$ LASER ILLUMINATION AFTER SURGICAL EXTRACTION OF IMPACTED 3RD MOLAR (하악 매복치 발치 후 $CO_2$ laser 조사의 임상적 효과 분석)

  • Kim, In-Soo;Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.349-352
    • /
    • 2001
  • Dental laser provides many advantages to the clinicians. Those are excellent hemostatic effect, good operating sight, minimal adjacent tissue injury, reduction of postoperative swelling & pain, reduction of postoperative infection, reduction of scar tissue & contraction, etc. The purpose of this study is to observe how these advantages work after surgical extraction of impacted third molar. From march 2000 to july 2000, we have randomly divided the patients who had been surgically extracted unilateral impacted third molar into two groups. The first group comprised $CO_2$ laser illumination with 3 watts, defocusing & continuous mode, rotating motion for about 3 minutes after finishing of surgical extraction & suture. The other group patients were not irradiated. The medications in two groups were same. We measured pain, swelling and trismus three times(pre-operation, first day after operation, and 7th day after operation). The number of the patients who had measured three times all are 64, laser irradiated groups are 36 and non-irradiated groups are 28. The age ranged from 19 to 50, with a mean of 27.9 years. The operative time ranged from 3 minutes to 50 minutes, with a mean of 12.1 minutes. In the $CO_2$ laser group, the pain intensity of the 7th day after operation was still increased significantly comparing with that of the pre-operation and the distance which were measured for the swelling was different significantly. In the other group, the mouth opening limitation was still decreased significantly.

  • PDF

Study on the Effect of Design Parameters of the Vane Type Inertial Separator Using Commercial CFD Code (상용 CFD 프로그램을 사용한 베인형 관성분리기의 설계인자 영향 검토)

  • Lee, Dap-Yeon;Lew, Jae-Moon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.6
    • /
    • pp.470-475
    • /
    • 2017
  • Since the intake air of gas turbine engine of marine purpose contains water particles, inertial separator for separating the air and water particles are provided. Saw type and wave type separator are now used to separate inflow water particle from the gas. In this paper, the design parameters of saw type separator are studied by numerical simulations. Using the commercial CFD program, Star-CCM+, Lagrangian-Eulerian method was used to perform the analysis of two phase flow of the mist in the air. This method solves Reynolds-Averaged Navier-Stokes equations in Eulerian framework for the continuous phase, while solves equation of motion for individual particles in Lagrangian framework. Lagrangian multiphase method was applied to monitor the particles of different sizes and shapes and to verify collision between particles by chasing particles. Water particles were injected through injectors located at the inlet of the separator and escape mode was used which assumes that the particles attached on the surface of inertial separator were removed from the simulation, effectively escaping the solution domain. Through the numerical computations with the inlet condition of constant water particle size in the wetness fraction of 85%, efficiency of eliminating the water particle and the pressure drop between the inlet and outlet were examined.

Optimal Design of a Fine Actuator for Optical Pick-up (광픽업 미세구동부의 최적설계)

  • Lee, Moon-G;Gweon, Dae-Gab
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.819-827
    • /
    • 1997
  • In this paper, a new modeling of a fine actuator for an optical pick-up has been proposed and multiobjective optimization of the actuator has been performed. The fine actuator is constituted of the bobbin which is supported by wire suspension, the coils which wind around the bobbin, and the magnets which cause the magnetic flux. If current flows in the coils, magnetic force is so produced as to be balanced with spring force of wire, so the bobbin is pisitioned. In this model the transfer function from input voltage to output displacementof bobbin has been obtained so that we can describe this integrated system with electromagnetic and mechanical parts. Wire suspension is regarded as a continuous Euler beam, damper as distributed viscous damping, and bobbin as a rigid body which can move up- and down- ward motion only. According to the model, the high frequency dynamic characteristics of the fine actuator can be known and the effect of damping can be investigated while the conventional second order model cannot. In multiobjective optimization, two objective functions have been chosen to maximize the fundamental frequency and the sensitivity with respect to the input voltage of the actuator so that Pareto's optimal solutions have been obtained using .epsilon.-constraint method. These objective functions will satisfy the trends which will enhance the access speed and reduce the tracking error in the optical pick-up technology of next generation. In the result of optimization, we obtain the designs of the optical pick-up fine actuator which has high speed, high sensitivity and low resonant peak. Furthermore, we offer the relation between two object functions so that the designer can make easy choice.

The Effects of Microcurrent Treatment and Ultrasound Treatment on the Pain Relief and Functional Recovery after Total Knee Replacement (미세전류치료와 초음파치료가 슬관절전치환술 후 통증경감과 기능회복에 미치는 영향)

  • Cho, Woon-Su;Kim, Yong-Nam;Kim, Yong-Seong;Hwang, Tae-Yeon;Jin, Hee-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.118-126
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate pain relief and functional recovery after total knee replacement. Methods: The treatment was performed by dividing individuals into a control group ($n_1=5$), ultrasound treatment group ($n_2=5$), and micro-current treatment group ($n_3=5$). The control group applied the hot pack for 15 minutes, Transcutaneous Electrical Nerve Stimulation (TENS) for 15 minutes, and Continuous Passive Movement (CPM) for 40 minutes. The ultrasound therapy group applied the frequency of 1 MHz, intensity of 1.0 $W/cm^2$ for five minutes following the same treatment as the control group. The micro-current therapy group applied the intensity of 25 ${\mu}A$, and pulsation frequency 5 pps for 15 minutes following the same treatment as the control group. After treatment, Visual Analogue Scale (VAS), Korean Western Ontario and McMaster Universities Arthritis Index (K-WOMAC), Berg Balance Scale (BBS), Range of Movement (ROM) and wound length was measured. Results: VAS showed significant effect in the control group and micro-current therapy group during the treatment period. According to the treatment of K-WOMACK, BBS, ROM, and Healing wounds showed main effects between groups. Conclusion: According to the results of this study, data showed improvement of pain relief, wound healing effects, and range of motion recovery. Thus, these selected treatments were effective after total knee replacement. In other words, electrical treatment continues to influence pain relief and functional recovery after total knee replacement.

Investigation of Unbalanced Mass of a Work Roll in a Cold Rolling Mill (냉간 압연기에서 작업롤의 질량 불평형에 관한 연구)

  • Kim, Young-Deuk;Kim, Chang-Wan;Park, Hyun-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.429-435
    • /
    • 2012
  • An abrasion due to continuous friction between a work roll and strip causes the mass of the work roll to be unbalanced in the rolling process. We developed a mathematical model for the rolling mill considering the unbalanced mass and verified the model experimentally. The work roll was approximated as a rigid rotor with eccentricity, and the effect of the unbalanced mass on chatter vibration was investigated. The joint forces computed by quasistatic analysis were applied to the work roll in the rolling mill. Transient responses were obtained, and frequency analysis was performed by solving equations of motion using a direct integration method. Horizontal vibrations were more strongly affected by eccentricity than vertical vibrations. In the horizontal direction, a small eccentricity of 1% of the work roll radius considerably increased the amplitude of the chatter frequency.

Free vibration analysis of combined system with variable cross section in tall buildings

  • Jahanshahia, Mohammad Reza;Rahgozar, Reza
    • Structural Engineering and Mechanics
    • /
    • v.42 no.5
    • /
    • pp.715-728
    • /
    • 2012
  • This paper deals with determining the fundamental frequency of tall buildings that consist of framed tube, shear core, belt truss and outrigger systems in which the framed tube and shear core vary in size along the height of the structure. The effect of belt truss and outrigger system is modeled as a concentrated rotational linear spring at the belt truss and outrigger system location. Many cantilevered tall structures can be treated as cantilevered beams with variable cross-section in free vibration analysis. In this paper, the continuous approach, in which a tall building is replaced by an idealized cantilever continuum representing the structural characteristics, is employed and by using energy method and Hamilton's variational principle, the governing equation for free vibration of tall building with variable distributed mass and stiffness is obtained. The general solution of governing equation is obtained by making appropriate selection for mass and stiffness distribution functions. By applying the separation of variables method for time and space, the governing partial differential equation of motion is reduced to an ordinary differential equation with variable coefficients with the assumption that the transverse displacement is harmonic. A power-series solution representing the mode shape function of tall building is used. Applying boundary conditions yields the boundary value problem; the frequency equation is established and solved through a numerical process to determine the natural frequencies. Computer program has been developed in Matlab (R2009b, Version 7.9.0.529, Mathworks Inc., California, USA). A numerical example has been solved to demonstrate the reliability of this method. The results of the proposed mathematical model give a good understanding of the structure's dynamic characteristics; it is easy to use, yet reasonably accurate and suitable for quick evaluations during the preliminary design stages.

Effects of Pressure Biofeedback Unit Application on Muscle Strength and Balance in Total Knee Arthroplasty Patients during Exercise for Strengthening the Knee Extensor Muscle (무릎 폄근 강화 운동 동안 압력 생체되먹임 장비 적용이 무릎관절 전치환술 환자들의 근력과 균형에 미치는 영향)

  • Park, Jin;Park, Han-Kyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.101-108
    • /
    • 2021
  • Purpose : The purpose of this study is to verify the effect of selective muscle strengthening of the knee joint extensor muscles using a pressure biofeedback unit to improve knee extensor strength and the balance ability of total knee replacement patients. Through this, we tried to provide clinical information. Methods : In this study, 12 patients with total knee replacement were recruited from a rehabilitation hospital. They were divided into two groups: a feedback group (n=6) and a control group (n=6). All patients received 30 minutes of continuous passive motion and leg-strengthening exercises for 15 minutes five times a week for two weeks. Subjects performed knee extension exercises with or without biofeedback units in the sitting position. The knee extensor strength and balance ability were measured before and after exercise. Knee extensor strength was measured by Biodex system 3 and balance ability was measured by Balancia software. Results : Both the experimental group and the control group showed a significant difference in the muscle strength of the knee joint extensor muscles after intervention (p<.05). In comparison, the experimental group showed a significant difference than the control group (p<.05). Both the experimental group and the control group showed a significant difference in the velocity average, path length, area 95 % center of pressure (COP), weight distribution, five times sit to stand test (FTSST) after intervention. In comparison, the experimental group showed a significant difference in velocity average, area 95 % COP, and FTSST than the control group (p<.05). Conclusion : In order to strengthen the knee extensor muscle and improve the balance ability in total knee replacement patients, it is necessary to consider providing pressure biofeedback unit during leg strengthening exercises.

Injection of a Denser Fluid into a Rotating Cylindrical Container Filled with Homogeneous Lighter Fluid (균질의 회전유체에 고밀도유체 주입실험)

  • 나정열;황병준
    • 한국해양학회지
    • /
    • v.30 no.4
    • /
    • pp.355-364
    • /
    • 1995
  • A heavy fluid is injected to a rotating cylindrical container of flat or inclined bottom filled with homogeneous lighter fluid. Continuous flow-in and spreading patterns over the bottom of the container are observed and at the same time upper-layer motions induced by the movement of the heavy fluid are traced by thymol blue solution. Regardless of bottom geometry, the injected denser fluid is deflected toward "western wall" and continuous its path along the boundary with radial spreading which occurs in the bottom boundary layer to make a quite asymmetric flow. When the bottom contains a slope(${\beta}$-plane), increased pressure gradient causes the fluid move faster to produce a stronger Coriolis force. This makes the width of the flow narrower than that of f-plane. But, when the denser flow reaches the southern part of the container, a local-depth of denser fluid increases (much greater than the Ekman-layer depth) such that the spreading velocity along the wall is reduced and the interfacial slope increases to make the upper-layer adjust geographically to have oppositely directed upper-layer motion along the interfacial boundary. The role of the denser fluid in terms of vorticity generation in the upper-layer is such that it produces local topographic effect over the western half of the container and also induces vortex-tube stretching which is especially dominant in the f-plane.

  • PDF

Shipboard Active Phased Array Antenna System for Satellite Communications (위성 통신용 선박 탑재 능동 위상배열 안테나 시스템)

  • 전순익;채종석;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1089-1097
    • /
    • 2002
  • In this paper, the novel shipboard Active Phased Array Antenna(APAA) system for maritime mobile satellite communications is introduced. The antenna uses novel technologies like wide range hybrid tracking, single antenna elements with both of Rx and Tx, asymmetrical array structure, interference isolation between Rx and Tx, and error correction method from frequency scan effect. The antenna has single aperture for both of Rx and Tx with 32 $\times$ 4 two-dimensional array. The antenna has two beams. Its frequencies are 7.25 ~ 7.75 GHz for Rx and 7.9 ~ 8.4 GHz for Tx. The antenna gains are 35.4 dBi for Rx and 35.7 dBi for Tx, those are 54 % of efficiency. The electrically steering ranges are $\pm$35$^{\circ}$ of elevation direction and $\pm$4$^{\circ}$ of azimuth direction. The mechanical control ranges at hybrid tracking capability are continuous 360$^{\circ}$ of azimuth direction and $\pm$10$^{\circ}$ of elevation direction. The antenna has 2.2$^{\circ}$ of 3 dB beamwidth, -14 dB of sidelobe level, and 21 dB of cross-pol suppression. The antenna performance was measured by near field measurement set. Its system performance was tested on the ship motion simulator and with the satellite transponder simulator. The test result showed that its tracking error was within -3 dB from its peak gain under motion condition. The antenna system was tested by real modulated Direct Broadcasting Satellite(DBS) signals to check its communication processing function.