• 제목/요약/키워드: Continuous Fluid

검색결과 346건 처리시간 0.024초

가스와 입자가 혼합된 2상 유동에 관한 수치해석적 연구 (Numerical Simulation of Two-Phase Flow for Gas-Solid Particles)

  • 정훈;최종욱;박찬국
    • 한국전산유체공학회지
    • /
    • 제6권4호
    • /
    • pp.8-14
    • /
    • 2001
  • The phenomena of two-phase suspension flows appear widely in nature and industrial processes. Hence, it is of great importance to understand the mechanism of the gas-solid two-phase flows. In the present study, the numerical simulation has been approached by utilizing the Eulerian-Lagrangian methodology for describing the characteristics of the fluid and particulate phases in a vertical pipe and a 90°square-sectioned bend. The continuous phase(gas phase) is described by the Eulerian formulation and a κ-ε turbulence model is employed to find mean and turbulent properties of the gas phase. The particle properties(velocity and trajectory) are then described by a Lagrangian approach and computed using the mean velocity and turbulent fluctuating velocity of the gas phase. The predictions are compared with measurements by laser-Doppler velocimeter for the validation. As a result, the calculated results show good agreements.

  • PDF

CFD를 이용한 관상 열교환기형 반응기의 mixing 효율 분석 (ANALYSIS OF MIXING EFFICIENCY OF A TUBULAR HEAT-EXCHANGER REACTOR USING CFD)

  • 이지현;송현섭;한상필
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.45-47
    • /
    • 2005
  • We have investigated the mixing behavior of a tubular heat exchanger reactor using CFD and compared its mixing performance with different type of reactors such as jet mixer and continuous stirred tank reactor (CSTR). The mixedness in each reactor was quantified introducing a statistical average value, the coefficient of variation (CoV), which is a normalized standard deviation of concentration of a component over the whole fluid domain. Through the analysis of the flow pattern and turbulent energy distribution, we suggested a simple but effective way to improve the mixing performance of the tubular heat-exchanger reactor, which include the addition of the internals and/or the increase of the recycle flow rate. It was found that the CoV value of the tubular reactor could be nearly equivalent to that of CSTR by applying those two alternatives suggested here.

  • PDF

경막외 카테터의 지주막하강으로의 이전 -증례 보고- (Presumed Subarachnoid Migration of an Epidural Catheter -A case report-)

  • 김기준;박병학;이윤우;윤덕미;남용택;김승준
    • The Korean Journal of Pain
    • /
    • 제11권2호
    • /
    • pp.311-313
    • /
    • 1998
  • Continuous epidural catheter insertion is common practice in postoperative analgesia. Subarachnoid migration of epidural catheter is a rare complication. Presumed delayed subarachnoid migration of an epidural catheter occured in a 58-year-old female patient after subtotal gastrectomy. Delayed respiratory depression occured 7 hrs after transfer to admission room. She was intubated and had ventilatory care. The fluid from the epidural catheter was examined and the result showed that gucose was 107 mg% and protein was 31 mg%. Immediate naloxone administration and ventilatory care for one day was done. The patient discharged without any sequalae.

  • PDF

Simplex Swirl Injector의 Injection Instability에 관한 연구 (The Phenomena of Injection Instability for Simplex Swirl Injector)

  • 박병성;김호영;전철균
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.287-293
    • /
    • 2005
  • Most of all combustion system has combustion instability. It is a serious problem in combustion system. Unstable injection is one of the source of combustion instability. The experimental investigation of spray characteristics for simplex swirl injector were conducted experimentally. Two kerosene based fuels were chosen as the atomizing fluid. As the major operating parameters, fuel temperature and injection pressure were chosen, and varied in the range from 253 K to 293 K and from 0.2 MPa to 1.0 MPa, respectively. Direct spray images and mean diameter were measured for the various combination of operating parameters in the flow field. The results of present study show that the injection pressure and spray cone angle are fluctuated at specific conditions while it is continuous steady injection. As the fuel temperature changes continuously, spray cone angle varies discontinuously through the region of injection instability.

  • PDF

디지털 Holographic PTV기법을 이용한 미세튜브 내부 3차원 유동장 측정 (Measurement of 3D Flow inside Micro-tube Using Digital Holographic PTV Technique)

  • 김석;김주희;이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.177-178
    • /
    • 2006
  • Digital holographic particle tracking velocimetry (HPTV) is developed by single high-speed camera and single continuous laser with long coherent length. This system can directly capture 4000 hologram fringe images for 1 second through a camera computer memory. The 3D particle location is made of the reconstruction by using a computer hologram algorithm. This system can successfully be applied to instantaneous 3D velocity measurement in the water flow inside a micro-tube. The average of 100 instantaneous velocity vectors is obtained by reconstruction and tracking with the time of evolution of recorded fringes images. In the near future, we will apply this technique to measure 3D flow information inside various micro structures.

  • PDF

머리 가속도를 고려한 의자 서스펜션의 퍼지제어 (Fuzzy Control of the Seat Suspension System Considering the Acceleration of a Driver's Head)

  • 공경철;전도영
    • 제어로봇시스템학회논문지
    • /
    • 제11권7호
    • /
    • pp.572-577
    • /
    • 2005
  • This paper applies the fuzzy logic controller to a semiactive seat suspension system in order to obtain the better ride comfort in constraint of specific rattle space. The seat suspension system used for this research is a scissors-type one with the MR (Magneto Rheological) fluid damper. Since a seat suspension system with a driver can not be exactly modeled, it is effective to control with the fuzzy logic controller. The rule was carefully tuned to effectively reduce the vibration transmitted to a driver. The on-road ride was realized on a hydraulic excitor and the result shows that the fuzzy controller has reduced the vibration of a seat suspension system compared to the continuous skyhook controller.

비정렬격자 SIMPLE 알고리즘기반 이상유동 수치해석 기법 (NUMERICAL METHOD FOR TWO-PHASE FLOW ANALYSIS USING SIMPLE-ALGORITHM ON AN UNSTRUCTURED MESH)

  • 김종태;박익규;조형규;김경두;정재준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.71-78
    • /
    • 2008
  • For analyses of multi-phase flows in a water-cooled nuclear power plant, a three-dimensional SIMPLE-algorithm based hydrodynamic solver CUPID-S has been developed. As governing equations, it adopts a two-fluid three-field model for the two-phase flows. The three fields represent a continuous liquid, a dispersed droplets, and a vapour field. The governing equations are discretized by a finite volume method on an unstructured grid to handle the geometrical complexity of the nuclear reactors. The phasic momentum equations are coupled and solved with a sparse block Gauss-Seidel matrix solver to increase a numerical stability. The pressure correction equation derived by summing the phasic volume fraction equations is applied on the unstructured mesh in the context of a cell-centered co-located scheme. This paper presents the numerical method and the preliminary results of the calculations.

  • PDF

Continuous Viscosity Measurement of Non-Newtonian Fluids over a Range of Shear Rates Using a Mass-Detecting Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제16권2호
    • /
    • pp.255-261
    • /
    • 2002
  • A newly designed mass-detecting capillary viscometer uses a novel concept to continuously measure non-Newtonian fluids viscosity over a range of shear rates. A single measurement of liquid-mass variation with time replaces the now rate and pressure drop measurements that are usually required by capillary tube viscometers. Using a load cell and a capillary, we measured change in the mass flow rate through a capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For aqueous polymer solutions, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. This new method overcomes the drawbacks of conventional capillary viscometers meassuring non-Newtonian fluid viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure non -Newtonian viscosity over a wide range of shear rate extending as low as 1 s$\^$-1/. Second, this design provides simplicity (i. e., ease of operation, no moving parts), and low cost.

NUFLEX의 상변화, 분무유동 및 MHD 해석 (NUMERICAL ANALYSIS OF PHASE CHANGE AND SPRAY, MHD FLOW USING A NUFLEX)

  • 노경철;유홍선;강관구;허남건
    • 한국전산유체공학회지
    • /
    • 제12권2호
    • /
    • pp.32-36
    • /
    • 2007
  • NUFLEX is a general purpose program for the analysis 3D thermo/fluid flow and pre/post processor in a complex geometry. NUFLEX is composed of various physical models, such as phase change(solidification/melting) and spray, MHD(Magneto Hydraulic Dynamics) models. It is possible to simulate continuous cast iron process and spray droplet breakup/collision phenomenon. For the verification of these models, compared with the experimental data and commercial CFD code's results. The results show good agreements with experimental and comercial CFD codes's results.

비정렬격자 SIMPLE 알고리즘기반 이상유동 수치해석 기법 (NUMERICAL METHOD FOR TWO-PHASE FLOW ANALYSIS USING SIMPLE-ALGORITHM ON AN UNSTRUCTURED MESH)

  • 김종태;박익규;조형규;김경두;정재준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.71-78
    • /
    • 2008
  • For analyses of multi-phase flows in a water-cooled nuclear power plant, a three-dimensional SIMPLE-algorithm based hydrodynamic solver CUPID-S has been developed. As governing equations, it adopts a two-fluid three-field model for the two-phase flows. The three fields represent a continuous liquid, a dispersed droplets, and a vapour field. The governing equations are discretized by a finite volume method on an unstructured grid to handle the geometrical complexity of the nuclear reactors. The phasic momentum equations are coupled and solved with a sparse block Gauss-Seidel matrix solver to increase a numerical stability. The pressure correction equation derived by summing the phasic volume fraction equations is applied on the unstructured mesh in the context of a cell-centered co-located scheme. This paper presents the numerical method and the preliminary results of the calculations.

  • PDF