• Title/Summary/Keyword: Contiguous wall

Search Result 12, Processing Time 0.022 seconds

Application of numerical simulation for the analysis and interpretation of pile-anchor system failure

  • Saleem, Masood
    • Geomechanics and Engineering
    • /
    • v.9 no.6
    • /
    • pp.689-707
    • /
    • 2015
  • Progressive increase in population causing land scarcity, which is forcing construction industry to build multistory buildings having underground basements. Normally, basements are constructed for parking facility. This research work evaluates important factors which have caused the collapse of pile-anchor system at under construction five star hotel. 21 m deep excavation is carried out, to have five basements, after installation of 600 mm diameter cast in-situ contiguous concrete piles at plot periphery. To retain piles and backfill, soil anchors are installed as pit excavation is proceeded. Before collapse, anchors are designed by federal highway administration procedure and four anchor rows are installed with three strands per anchor in first row and four in remaining. However, after collapse, system is modeled and analyzed in plaxis using mohr-coulomb method. It is investigated that in-appropriate evaluation of soil properties, additional surcharge loads, lesser number of strands per anchor, shorter grouted body length and shorter pile embedment depth caused large deformations to occur which governed the collapse of east side pile wall. To resume work, old anchors are assumed to be standing at one factor of safety and then system is analyzed using finite element approach. Finally, it is concluded to use four strands per anchor in first new row and five strands in remaining three with increase in grouted and un-grouted body lengths.

Behavior of Reinforced Earth Retaining Wall for Permitting Reinforcement to Subside with Monitoring (현장계측을 통한 보강재 침하형 보강토 옹벽의 거동특성)

  • Chung, Jin-Hyuck;Oh, Jong-Keun;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.2
    • /
    • pp.5-15
    • /
    • 2009
  • The conventional reinforced earth retaining wall has the connector system to fix the reinforcement and block. However, this system defect may cause the crack of block and the rupture of reinforcement due to the stress concentration near the face of reinforced earth retaining wall. Hence, the new connector system which was able to allow the settlement of reinforcement was developed in this study and a test was carried out in the study area which is divided into the conventional reinforced earth retaining wall and reinforced Earth Retaining Wall driving the settlement. As the results of field monitoring in situ, the ratio of tensile force calculated at maximum value on contiguous portion of front block showed that the settlement type decreased the stress concentration near the face of front block greater than the conventional type.

Study on the Performance Evaluation of CS-H Wall composed of Steel Fiber (강섬유를 이용한 CS-H 벽체의 성능 평가에 관한 연구)

  • YU, Nam-Jae;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 2017
  • In this study, CS-H walls with large stiffness were constructed using geosythetics for use in excavation at a depth of 30 m or more in Korea, and in order to construct the CS-H wall suitable for the site conditions, the formulation was examined according to the change in the mixing ratio of the geosythetics and the slump value (slump flow) and as a result, in the target slump 180 mm and the slump flow 500 mm, the formulation was confirmed to meet the mechanical properties such as the initial bending strength, the long-term behavior, and the elastic modulus as well as the economic efficiency. However, in the slump flow 600 mm, the result indicated that the formulation was inappropriate in the mechanical properties such as the initial bending strength, the long-term behavior, and the elastic modulus.

The Behavior of Earth Retaining Walls Applied to Top-Down Construction Method Using Back Analysis (Top-Down 공법이 적용된 흙막이벽의 역해석을 이용한 거동분석)

  • Hong, Won-Pyo;Kang, Chul-Joong;Yun, Jung-Mann
    • The Journal of Engineering Geology
    • /
    • v.22 no.1
    • /
    • pp.39-48
    • /
    • 2012
  • The behaviors of a diaphragm wall and a contiguous pile wall such as CIP(Case-in-place pile) and SCW(Soil-cement wall), applied to the top-down construction method, were analyzed using the SUNEX program, which is widely used to design earth retaining walls. Four types of earth pressures, as described by Rankine (1857), Terzaghi and Peck (1967), Tchbotarioff (1973), and Hong and Yun (1995a), were applied to the analysis program to predict the lateral displacement of walls. The results show that the displacements of an earth retaining walls vary with the applied earth pressure. The predicted lateral displacement based on Hong & Yun's (1995a) earth pressure is similar to the measured displacement. Therefore, the actual lateral displacement of an earth retaining wall, as applied to top-down construction method, can be accurately predicted by using an analysis program considering Hong and Yun's (1995a) earth pressure.

The Effect of Composite Ratio and Wall Thickness on the Shear Behavior of Composite Basement Wall (합성율과 벽체두께가 합성지하벽의 전단거동에 미치는 영향)

  • Seo, Soo-Yeon;Kim, Seong-Soo;Yoon, Yong-Dae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • When doing underground excavation works for the purpose of constructing large underground structures for a building in the limited space in downtown area, the stability of the adjacent ground must be top priority, and to accomplish this, it is essential to review the retaining wall construction carefully. H-Pile, which has been mainly used as a stress-carrying material in temporary earth-retaining structures, is most likely to be abandoned after completion of the works for the basement exterior wall in relation to contiguous bored piles, so it will result in a waste of material. To improve this situation, Basement Composite Wall where H-Pile and basement wall are compounded, has been developed. This wall is being used most frequently in many local construction sites. In this study, five specimens are made in order to evaluate the shear resistance of the basement composite wall and tested. Test parameter is the composition ratio and wall thickness according to shear connectors. Test result shows that the shear strength is improved when the composite ratio is increased but the magnitude is not much. A formula, which considers the contribution of concrete, web of H-pile as well as flange' effect in calculation of shear strength of composite basement wall, is suggested and used to calculation of the strength of specimens. It is found that there is a good co-relation between test result and the calculated one by the formula.

A Study on the Minimum Distance between Landscape Trees and Apartment Buildings (수목생육 조건을 고려한 조경수목과 아파트 건물의 최소 이격거리에 관한 연구)

  • Jang, Ha-Kyung;Ahn, Geun-Young;Lee, Eun-Heui
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.1 s.120
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study is to suggest the minimum distance needed between landscape trees and apartment buildings. in order for the trees to grow soundly and maintain constant growth. Therefore, this study investigated and analyzed the present conditions of the green-spaces contiguous to apartment buildings and the trees inside the apartment complex. The following general problems were identified : (1) the tree growth conditions, (2) the planting intervals, and (3) the planting methods in the apartment complexes. The method of this study was to survey areas, measure the trees and analyze the results. Ten apartment complexes located in Seoul were randomly selected for this study. To analyze the greens contiguous to the building of each apartment complex, the greens were divided into three types, including the front greens, the side greens, and the rear greens. The study surveyed the width of all contiguous greens and the distance from trees to my given building. Four representative sites were specifically investigated to measure the crown widths, heights, and diameters of the trees. These investigations were carried out over 3 months from August to December 2006. According to the results of the study, it was found that the greens are narrower in width and the more closer to a building. The study identified a correlation between the tree and the passage of time after the completion of construction of an apartment complex, showing that the malformation of the trees worsened as time passed. As a result of measuring the right crown and left crown width with the tree trunk as the center, a broad difference was found between coniform trees and trees that tend to branch out more. For example, the ratio of the width of the Acer palmatum is 1:6. However, the ratio of the Metasequoia glyptostroboide is 1:1.7. Based on the overall analysis, it was concluded that the maintained minimum width must be greater than one meter over the green space according to the 'Landscape Standard 2000'. However, that is only applicable to cases such as apartment buildings that present no obstacles. In conclusion having greens placed within one meter of width to a building is not an appropriate environment for the healthy growth of trees. To create sound green spaces, sustainable, long-term growth rate and size should be considered. It is necessary to prepare new standards for the computation of planting trees and the measurement of square landscapes. Wall greenery and shrubberies could be an alternative in the case of a narrow-width green space.

Restoration of Iksan Imperial Capital City Structure and Construction Model in Late Baekje from the Point of Ancient Capital City Planning (백제 후기 익산도성 조영계획모델에 대한 도성계획사적 해석)

  • Lee, Kyung-Chan
    • Journal of architectural history
    • /
    • v.24 no.3
    • /
    • pp.31-41
    • /
    • 2015
  • This study aims to draw out planning principles and structure of Iksan imperial capital city in late Baekje, especially in view of the relationship among imperial capital city planning area, skeletal axis and the location of royal castle. With site survey and analysis of historical records, old maps, topographical maps, archeological excavation data, land registration map of 1915, some significant inferences were drawn out. Firstly from the point of topological conditions, the contiguous line of a stratum from Mireuk mountain(彌勒山) to Wangkung-ri castle(王宮里遺蹟) and two waterways made a topological axis of Iksan Imperial capital city. Secondly district of Iksan imperial capital city can be deduced to the inner area north to Kummado soil wall(金馬都土城), south to the confluence of Iksan river(益山川) and Busang river(扶桑川), west to Okum mountain fortress(五金山城) and Galjeon river(葛田川), east to line near to eastern wall of Jesuksa temple(帝釋寺). Iksan ssang-reung(益山雙陵) was located outside western boundary line of capital city. Thirdly axis from Wangkung-ri castle to northern Kummado soil wall made a skeletal axis of city structure. It got through northern lowland along Buk river(北川) between Yonghwa(龍華山) and Mireuk mountain. Fourthly the location of royal palace can be deduced to the north part of the city around Kumma town area along the planning principle of northern royal palace.

Ultrastructure of Initial Cytological Changes of Cowpea in Root Nodule Formation

  • Kim, Young-Ho;Cheon, Choong-ll
    • The Plant Pathology Journal
    • /
    • v.15 no.2
    • /
    • pp.127-130
    • /
    • 1999
  • Cytological changes of cowpea root at the early stage of root nodule formation (within 5 days after inoculation) were viewed by light and electron microscopy. The root region affected by the rhizobial infection, which was composed of a redial array of cortical cells, had prominent cell divisions, mostly anticlinal in the inner cortical cells and in addition oblique and periclinal in the outer cells. An infected root hair cell (or root hair-producing epidermal cell) had numerous infection threads and degenerated cytoplasm. Module meristem was formed adjacent to the infected root hair cell, and characterized by dense cytoplasm, prominent nucleus, numerous small vacuoles, and increased plastids, containing infection threads as well. Bacterial cells were dividing inside the infection thread, the wall materials of which appeared to be dissolved ad accumulated in small vacuoles. inner cortical cells contiguous to the nodule meristem appeared to be actively dividing and dedifferentiating; however, they were not infected by the rhizobia. These structural characteristics are similar to those in the Bradyrhizobium-soybean association previously reported, and may reflect the similar cytological process in cowpea in the early nodule formation.

  • PDF

Automated Detection and Volume Calculation of Nodular Lung Cancer on CT Scans (CT 영상에서 결절성 폐암의 자동추출 및 체적계산)

  • Kim, Do-Yeon;Kim, Jin-Hwan;Noh, Seung-Moo;Park, Jong-Won
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.5
    • /
    • pp.451-457
    • /
    • 2001
  • This paper describes automated methods for the detection of lung nodules and their volume calculation on CT scans. Gray-level threshold methods were used to segment the thorax from the background and then the lung parenchymes from the thoracic wall and mediastinum. A scanning-ball algorithm was applied to more accurately delineate the lung boundaries, thereby incorporating peripheral nodules contiguous to pleural surface within the segmented lung parenchymes. The lesions which have the high gray value were extracted from the segmented lung parenchymes. The selected lesions include nodules, blood vessels and partial volume effects. The discriminating features such as size, solid-shape, average, standard deviation and correlation coefficient of selected lesions were used to distinguish true nodules from pseudo-lesions. Volume and circularity calculation were performed for each identified nodules. The identified nodules were sorted in descending order of the volume. These method were applied to 621 image slices of 19 cases. The sensitivity was 95% and there was no false-positive result.

  • PDF

Imaging Diagnosis: Heartbase Tumor in a Dog (개의 심기저부 종양의 영상진단학적 특징)

  • Chang, Jin-Hwa;Jung, Joo-Hyun;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.48-51
    • /
    • 2008
  • A ten-year-old Yorkshire Terrier developed serious abdominal distension and respiratory distress. Radiography and ultrasonography revealed a hyperechoic mass around the aorta that was contiguous with the right atrium and main pulmonary artery. It was resulted in failure of the right side of the heart including tricuspid regurgitation, hepatomegaly with dilation of the hepatic vein and severe ascites due to a large, expansile mass. Computed tomography(CT) identified a large mass originating at the cardiac hilar region and spanning from the cranial vena cava to the caudal vena cava. The tumor had invaded the cranial vena cava, caudal vena cava, heart and pleural wall. A tentative diagnosis of chemodectoma was assigned to the tumor through a fine needle aspiration. This report focuses on the typical features of imaging diagnosis of heartbase tumors by radiography, ultrasonography and CT.