• Title/Summary/Keyword: Content spectrum

Search Result 395, Processing Time 0.032 seconds

Generation of Artificial Earthquake Ground Motions using Nonstationary Random Process-Modification of Power Spectrum Compatible with Design Response Spectrum- (Nonstationary Random Process를 이용한 인공지진파 발생 -설계응답스펙트럼에 의한 파워스펙트럼의 조정-)

  • 김승훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.61-68
    • /
    • 1999
  • In the nonlinear dynamic structural analysis the given ground excitation as an input should be well defined. Because of the lack of recorded accelerograms in Korea it is required to generate an artificial earthquake by a stochastic model of ground excitation with various dynamic properties rather than recorded accelerograms. It is well known that earthquake motions are generally non-stationary with time-varying intensity and frequency content. Many researchers have proposed non-stationary random process models. Yeh and Wen (1990) proposed a non-stationary modulation function and a power spectral density function to describe such non-stationary characteristics. Satio and Wen(1994) proposed a non-stationary stochastic process model to generate earthquake ground motions which are compatible with design reponse spectrum at sites in Japan. this paper shows the process to modify power spectrum compatible with target design response spectrum for generating of nonstationary artificial earthquake ground motions. Target reponse spectrum is chosen by ATC14 to calibrate the response spectrum according to a give recurrence period.

  • PDF

Design of e-Learning System for Spectral Analysis of High-Order Pulse (고차원펄스 스펙트럼 분석을 위한 이러닝 시스템의 설계)

  • Oh, Yong-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.8
    • /
    • pp.475-487
    • /
    • 2011
  • In this paper, we present a systematic method to derive spectrum of high-order pulse and a novel design of e-Learning system that deals with deriving the spectrum using concept-based branching method. Spectrum of high-order pulse can be derived using conventional methods including 'Consecutive Differentiations' or 'Convolutions', however, their complexity of calculation should be too high to be used as the order of the pulse increase. We develop a recursive algorithm according to the order of pulse, and then derive the formula of spectrum connected to the order with a newly designed look-up table. Moving along, we design an e-Learning content for studying the procedure of deriving high-order pulse spectrum described above. In this authoring, we use the concept-based object branching method including conventional page or title-type branching in sequential playing. We design all four Content-pages divided into 'Modeling', 'Impulse Response and Transfer Function', 'Parameters' and 'Look-up Table' by these conceptual objects. And modules and sub-modules are constructed hierarchically as conceptual elements from the Content-pages. Students can easily approach to the core concepts of the analysis because of the effects of our new teaching method. We offer step-by-step processes of the e-Learning content through unit-based branching scheme for difficult modules and sub-modules in our system. In addition we can offer repetitive learning processes for necessary block of given learning objects. Moreover, this method of constructing content will be considered as an advanced effectiveness of content itself.

Applications of the wavelet transform in the generation and analysis of spectrum-compatible records

  • Suarez, Luis E.;Montejo, Luis A.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.2
    • /
    • pp.173-197
    • /
    • 2007
  • A wavelet-based procedure to generate artificial accelerograms compatible with a prescribed seismic design spectrum is described. A procedure to perform a baseline correction of the compatible accelerograms is also described. To examine how the frequency content of the modified records evolves with time, they are analyzed in the time and frequency using the wavelet transform. The changes in the strong motion duration and input energy spectrum are also investigated. An alternative way to match the design spectrum, termed the "two-band matching procedure", is proposed with the objective of preserving the non-stationary characteristics of the original record in the modified accelerogram.

A Study on the Combustion Characteristics with Hydrogen Contents of SNG Fuel in Low-Swirl Combustor (저선회 연소기에서 합성천연가스(SNG) 연료의 수소함량에 따른 연소 특성 연구)

  • JEONG, HWANGHUI;KANG, KIJOONG;LEE, KEEMAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.181-189
    • /
    • 2017
  • This paper describes experimental results on combustion characteristics with hydrogen contents of synthetic natural gas (SNG) in low swirl combustor. To investigate the effect of hydrogen contents for premixed SNG flame, stability map, CH chemiluminescence images, flame spectrum analysis and emission performances were measured. In the results, as the hydrogen content was increased, the lean flammable limit was expanded and the flame length was decreased. The hydrogen contents affected the flame liftoff height, and it has different tendency according to the equivalence ratio and flame shape. The change of height and length of flame according to hydrogen contents is caused by the fast burning velocity of hydrogen, which can be confirmed by GRI 3.0 reaction mechanism in PREMIX code. The intensity of $OH^*$, $CH^*$ and $C_2^*$ was confirmed by spectrum analysis of flame. As a result, the $CH^*$ intensity was not significantly different according to hydrogen content. The increase of hydrogen contents influenced positively CO and NOx emission performances.

Development of a Continuous High-Speed Single-Kernel Brown Rice Sorting Machine Based on Rice Protein Content

  • Natsuga, Motoyasu;Nakamura, Akitoshi;Kawano, Sumio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1616-1616
    • /
    • 2001
  • To select kernels for breeding that have required constituent content from either naturally distributed samples or artificially mutated ones, it is necessary to process batch samples in a short time. The constituent content of single-kernel grains such as wheat and rice has been determined using conventional bench type NIR instruments; however, it takes a lot of time and effort. Shizuoka Seiki (Fukuroi-city, Japan) and NFRI (National Food Research Institute) of MAFF (Ministry of Agriculture, forestry and Fisheries of Japan) have jointly developed a continuous high-speed single-kernel brown rice sorting machine based on rice protein content. It consists of several sections such as a feeding mechanism, measuring unit, sorting mechanism and controlling PC. The feeding mechanism picks up single-kernel brown rice from the hopper (maximum of 5kg storage capacity) and sends it to the measuring unit. A spectrum of the brown rice is obtained in the measuring unit, which consists of a near-infrared array sensor. The brown rice is then sorted in the sorting mechanism based on its protein content estimated by the controlling PC. In the present study, measuring speed was approximately 500ms for the full spectrum range and overall sorting speed was approximately 2.8s for one kernel. Accuracy of estimation was approximately SEP=0.5% of dry matter protein content for nonglutinous rice.

  • PDF

An Improved Detection Technique for Spread Spectrum Audio Watermarking with a Spectral Envelope Filter

  • Jung, Sa-Rah;Seok, Jong-Won;Hong, Jin-Woo
    • ETRI Journal
    • /
    • v.25 no.1
    • /
    • pp.52-54
    • /
    • 2003
  • We propose an improved algorithm for detecting audio watermarks based on a spread spectrum in the spectral domain. Since the energy of a watermark is much smaller than that of the cover audio data, pre-processing to reduce the effect of the cover data is needed to reliably extract watermarks. We introduce a spectral envelope filter as a pre-process that enhances detecting performance by filtering out the intrinsic spectral character of cover data. The proposed watermarking structure can be easily included in the compression system and can extract watermarks from partially decompressed spectral data. Our experimental results demonstrate that with a bit error rate of around 10 dB against general attacks, the proposed detecting scheme works better than detectors without the spectral filter.

  • PDF

Nondestructive Determination of Sugar Contents in Shingo Pears with Different Temperature

  • Lee, Kang-J.;Choi, Kyu H.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1264-1264
    • /
    • 2001
  • The affect of surface temperatures of fruits on spectrum which measures actual sugar contents was observed. PLSR was applied to develop the sugar content evaluation system that was not affected by temperature. The reflected spectrum was used at the wavelengths of 654 and 1052nm with the separation distance of 2.5nm. To increase the conformance of a model using unknown samples, let the minimum value of PRESS be an optimum factor. 71 Shingo pears stored in a refrigerator were left in a room temperature for a while and these temperatures and reflected spectrums were measured. Reflected spectrums were measured at the wavelengths of 654 and 1052nm, 3 samples in one second. To measure these at different temperatures, the experiment was repeated hourly and four times. Starting temperatures of 2-3 were increased up to 17. The total number of measured spectrum was 284. To develop a sugar content evaluation system model using measured reflected spectrum, three groups of samples were considered. First group had 51 samples at 14 and second group had 141 samples with lower or higher temperatures than 14. Third group had 155 samples with well distributed temperatures. Other samples were used as validations to ensure the conformance. Measuring the sugar contents of samples with surface temperatures other than 14 were difficult with PLS model I, developed by using a sample temperature of 14. If the sugar contents were compensated using samples' temperatures, results of prediction would be close to the expected results and it would be one of the most important factors to develop this system. PLS models I and II could compensate the temperature but the precision would not come up to the standard. High precision was expected by using samples with wide ranges of temperatures and sugar contents. Both models showed the possibility of an improvement of a sugar content evaluation system disregarding the temperature. For practical use of a system, selecting samples should be done carefully to reduce the effect of the temperature.

  • PDF

Absorption Spectroscopy of Biological Specimens Near X-ray Absorption Edges of Constituent Elements

  • Ito, Atsushi;Shinohara, Kunio
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.460-462
    • /
    • 2002
  • Absorption spectra of biological specimens in the soft X-ray region have been presented with special reference to the XANES (X-ray absorption Near Edge Structure) of constituent elements. Absorption spectrum in this wavelength region is characterized by the absorption edges from which elemental content could be derived. In addition, XANES has a characteristic profile for chemical environment around the element such as chemical bond. Using the specific absorption peak we can assign not only the chemical bond but also molecules having such a chemical bond. In the present paper, absorption spectrum of DNA was measured in the wavelength range from 1.5nm to 5nm. Spectrum of Chinese Hamster Ovary (CHO) cells was compared with the DNA spectrum. XANES were distinct at the K absorption edges of major elements, C, N and O. In the spectrum of the cells prominent peaks at the L absorption edge of minor element Ca were also detectable. XANES profiles in small local areas in a cell could also be measured in combination with X-ray microscopy. These give information about local chemical environment in a cell. XANES at the phosphorus K absorption edge in a human HeLa cell was successfully obtained corresponding to a sharp and intensive XANES peak of DNA.

  • PDF

Music Spectrum Analysis and a Content Summary Technique Based on the $\frac{1}{\Large f}$ Characteristic (음악의 스펙트럼 분석과 $\frac{1}{\Large f}$ 스펙트럼 특성을 이용한 대표부분 추출)

  • Bae, Jin-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12C
    • /
    • pp.1156-1163
    • /
    • 2007
  • A digital formatted music can be summarized with a fixed length using spectrum signal processing in this paper. We experimentally tested the hypothesis that the power spectrum of a popular music has $\frac{1}{\Large f}$ shape. Based on this hypothesis, a music is summarized by a system proposed in the paper. The system consists of a pre-processing block obtaining a test spectrum and a decision block calculating similarities. It is noteworthy that a digital formatted music can be summarized automatically using a similar system based on various hypotheses.

Study and Application of the Relationship between Water Content and Sugar Content in Fruit and Vegetables (청과물의 수분과 당도와의 관계 구명 및 응용)

  • 조성인;배영민
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.299-306
    • /
    • 1995
  • This study was carried to find out relationships between water content and sugar content in fruit and vegetables and present the possibility of estimating sugar content by measuring water content. Water content and sugar content of melons, peaches, and apples were measured. Both F-test and linear regression analysis on the experimental data were done. The regression models were developed and validated. The results were summarized as follow : 1. According to the F-test, the coefficients of determinant were greater than 0.8, and significance probability was less than 0.0001 in each materials. 2. According to the regression analysis of melons, peaches, and apples, the standard errors of calibration(SEC) were 0.67 brix%, 0.82 brix%, and 0.72 brix%, respectively. 3. The standard errors of prediction(SEP) were 0.76 brix%, 1.03 brix%, and 0.77 brix%, respectively. 4. The relationship between sugar content and water content in apple was successfully applied to measure the sugar content from hydrogen NMR spectrum of apple samples.

  • PDF