• Title/Summary/Keyword: Contamination source

Search Result 515, Processing Time 0.031 seconds

Evidences of in Situ Remediation from Long Term Monitoring Data at a TCE-contaminated Site, Wonju, Korea

  • Lee, Seong-Sun;Kim, Hun-Mi;Lee, Seung Hyun;Yang, Jae-Ha;Koh, Youn Eun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.8-17
    • /
    • 2013
  • The contamination of chlorinated ethenes at an industrial complex, Wonju, Korea, was examined based on sixteen rounds of groundwater quality data collected from 2009 to 2013. Remediation technologies such as soil vapor extraction, soil flushing, biostimulation, and pumping-and-treatment have been applied to eliminate the contaminant sources of trichloroethylene (TCE) and to prevent the migration of TCE plume from remediation target zones. At each remediation target zone, temporal monitoring data before and after the application of remediation techniques showed that the aqueous concentrations of TCE plume present at and around the main source areas decreased significantly as a result of remediation technologies. However, the TCE concentration of the plumes at the downstream area remained unchanged in response to the remediation action, but it showed a great fluctuation according to seasonal recharge variation during the monitoring period. Therefore, variations in the contaminant flux across three transects were analyzed. Prior to the remediation action, the concentration and mass discharges of TCE at the transects were affected by seasonal recharge variation and residual DNAPLs sources. After the remediation, the effect of remediation took place clearly at the transects. By tracing a time-series of plume evolution, a greater variation in the TCE concentrations was detected at the plumes near the source zones compared to the relatively stable plumes in the downstream. The difference in the temporal profiles of TCE concentrations between the plumes in the source zone and those in the downstream could have resulted from remedial actions taken at the source zones. This study demonstrates that long term monitoring data are useful in assessing the effectiveness of remediation practices.

Identification of pollutant sources using water quality and stable isotope ratios of inflow tributaries in the lower reaches of the Han-River

  • Hong, Jung-Ki;Lee, Bo-Mi;Son, Ju Yeon;Park, Jin-Rak;Lee, Sung Hye;Kim, Kap-Soon;Yu, Soon-Ju;Noh, Hye-ran
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.65-76
    • /
    • 2019
  • Despite the expansion of sewage treatment facilities to reduce pollutants in the tributaries of the Han River, water pollution accidents such as fish deaths continue to frequently occur. The purpose of this study was to identify the pollutant sources using water quality and stable isotope ratio (${\delta}^{15}N$, ${\delta}^{13}C$, ${\delta}^{15}N-NH_4$, ${\delta}^{15}N-NO_3$) analysis results in the three inflow tributaries (Gulpocheon (GP), Anyangcheon (AY) and Sincheon (SC)) of the Han River. Water quality was analyzed in June and October from 2013 to 2017, and the results showed that the concentrations of nutrients, such as T-N, $NO_3-N$, and T-P, were increased at GP4, AY3, SC3, and SC4, which lie downstream of sewage treatment facilities. The results of ${\delta}^{15}N$ for June 2017 indicated that the source of nitrogen was sewage or livestock excreta at GP4 and SC4, and organic fertilizers at AY3 and SC3. ${\delta}^{15}N-NO_3$ results suggested that the source of nitrogen was related to organic sewage, livestock or manure at GP4, AY3 and SC4. Therefore, GP4 and SC4 were more influenced by effluent from sewage treatment facilities than by their tributaries, AY3 and SC3 were considered to be influenced more by their tributary than effluent from sewage treatment facilities. With the results of this study, the source of contamination (sewage treatment facility effluent) of river inflow downstream of Han River could be confirmed using water quality and stable isotope ratio.

An Investigation of the Sources of Nitrate Contamination in the Kyonggi Province Groundwater by Isotope Ratios Analysis of Nitrogen (질소 동위 원소 분석을 이용한 경기도 지역 지하수 중 질산태 질소 오염원 구명)

  • Yoo, Sun-Ho;Choi, Woo-Jung;Han, Gwang Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.1
    • /
    • pp.47-56
    • /
    • 1999
  • $^{15}N$-Isotope concentrations of groundwater from l4 wells with different land-use types in Kyonggi Province were measured to investigate the nitrate contamination sources. Water samples were collected monthly from January to December 1997 and analyzed for pH. PC, anions (fluoride, chloride, nitrate, sulfate, inorganic phosphate, and bicarbonate), and canons (calcium, magnesium, potassium, and sodium). For the analysis of the $^{15}N/^{14}N$ ratio as ${\delta}^{15}N$, $N_2$ samples were prepared through Kjeldahl-Rittenberg method and were analyzed using an isotope ratio mass spectrometer (VG Optima IRMS). Reproducibility of the method and precision of the IRMS were below 1.0‰ and 0.1‰, respectively. The ionic composition of each groundwater sample was only slightly different according to the land-use type. The nitrate concentrations of groundwater in cropland or livestock farming areas were higher than those in the residential area. The percentages of nitrate to total anions of groundwater samples from the livestock farming area were higher than those of other areas. The ${\delta}^{15}N$ values of ammonium sulfate, urea, groundwater sample in the non-contaminated area, and water from the animal manure septic tank were -2.7, 1.4, 5.5, and 27.2‰, respectively. Based on the ${\delta}^{15}N$ values, the sources of nitrate could be classified as originated from chemical fertilizers with ${\delta}^{15}N$ values below 5% and as from animal manure or municipal waste with ${\delta}^{15}N$ values over 10‰. In most cases, contamination sources investigated from ${\delta}^{15}N$ values of groundwater samples were correlated with the specific sources according to the land-use types. However, some ${\delta}^{15}N$ values did not matched the apparent land-use types, and there were seasonal variations of ${\delta}^{15}N$ values within the same well. These results suggest that the groundwater quality was affected by two or more contamination sources and the contribution of each source to the groundwater quality varied depending on the sampling season.

  • PDF

Fate and Transport of Cr(VI) Contaminated Groundwater from the Industrial Area in Daejeon (대전 산업단지 지하수의 6가 크롬 오염 및 확산 평가)

  • Chon, Chul-Min;Moon, Sang-Ho;Ahn, Joo-Sung;Kim, Yung-Sik;Won, Jong-Ho;Ahn, Kyoung-Hwan
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.403-418
    • /
    • 2007
  • The objective of this research was to characterize the fate and transport of Cr(VI) contaminated groundwater in the Daejeon industrial area. Five subsidiary monitoring wells were newly installed and two existing wells were utilized for the investigation and the reduction process of Cr(VI) contaminated groundwater of the Daejeon(Mun-pyeong) national groundwater monitoring station. The Cr(VI) concentrations at the shallow aquifer well of the station were in the range of 3.2-4.5 mg/L indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other monitoring wells except MPH-1 and 3. The Cr(VI) concentrations of MPH-1 and MPH-3 were below the drinking water guideline value (0.05 mg/L). Therefore, the plume of the Cr(VI) contaminated groundwater was predicted to be confined within the narrow boundary around the station. The soluble/exchangeable Cr(VI) concentrations were below the detection limit in all core and slime samples taken from the five newly installed wells. Although the exact source of contamination was not directly detected in the study area, the spatial Cr(VI) distribution in groundwater and characteristics of the core samples indicated that the source and the dispersion range were confined within the 100 m area from the monitoring station. The contamination might be induced from the unlined landfill of industrial wastes which was observed during the installation of an subsidiary monitoring well. For the evaluation of the natural attenuation of Cr(VI), available reduction capacities of Cr(VI) with an initial concentration of 5 mg/L were measured in soil and aquifer materials. Dark-gray clay layer samples have high capacities of Cr(VI) reduction ranging from 58 to 64%, which is obviously related to organic carbon contents of the samples. The analysis of reduction capacities implied that the soil and aquifer materials controlled the dispersion of Cr(VI) contamination in this area. However, some possibilities of dispersion by the preferential flow cannot be excluded due to the limited numbers of monitoring wells. We suggest the removal of Cr(VI) contaminated groundwater by periodical pumping, and the continuous groundwater quality monitoring for evaluation of the Cr(VI) dispersion should be followed in the study area.

Contamination status of groundwater used as livestock drinking in beef and dairy cattle farms, Korea (국내 소사육농가의 자가용 가축음용수 오염실태 평가조사)

  • Jang, Yangho;Lee, Soojin;Kim, Hyobi;Lee, Jeonghak;Lee, Manho;Gil, Hyekyoung;Choe, Nonghoon
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • In Korea, groundwater is main water source in livestock farms. Most dairy and cattle farms have constructed their own wells for human drinking and livestock farming. However, these private residential wells have not been controlled by government and also there was scant study about livestock drinking water quality. Therefore this study was to monitor of the livestock farms' groundwater quality in Korea. Water samples were collected at 123 dairy and cattle farms and were analysed forty six substances with quality standard for drinking water approved by the Minister of Environment. Seventy eight (63.4%) of 123 samples failed to drinking water stand a test. The most frequent contaminants were nitrate-nitrogen and microbial. 22.8% (n=28) of samples showed nitrate-N concentration of higher than 10 mg/L meant that can't be used drinking water for human and the Nitrate-N concentration analysed in the range of 0.2 to 61.2 mg/L. All of 78 failed to drinking samples had microbial problems, especially 5.7% (n=7) of samples indicated water could be contaminated by feces. Other contaminants detected were zinc and evaporation residue. Especially detected zinc concentration (32 mg/L) was about ten times higher than standard of zinc (3 mg/L). Regression analysis indicated that groundwater pH did not influence to nitrate-N concentration but the hardness and chloride could affect to nitrate-N concentration in the groundwater. Most livestock farms were adjacent to crop farmland in Korea. This could cause contamination of groundwater with nitrate-N and pesticide that could accumulate livestock product. Moreover Heavy metal such as zinc and copper could be released from a corrosive plated water pipe in livestock farm. Put together, Korea livestock system is indoor, not pasture-based, hence livestock could be exposed to potential contaminated water consistently. Therefore on the basis of these data, appropriate livestock drinking water quality standards should be prepared to keep livestock healthy and their product safe. Further, livestock drinking water quality should be monitored continuously in suitable livestock drinking water standards.

Study on Pursuit of Contamination Sources and Establishment of Sanitary Standard from Raw Pork Meat (원료돈육의 오염원 추적 및 위생기준 설정에 관한 연구)

  • 임대석;강희곤;김용곤;김창한
    • Food Science of Animal Resources
    • /
    • v.21 no.2
    • /
    • pp.149-155
    • /
    • 2001
  • The aims of this study were to examine contamination sources and provide the basic data in establishment of sanitary standard for raw pork meat. From \"Random sampling(I)\", initial total plate counts of post-slaughter samples for the group A, B and C were 1.5${\times}10^4$cfu/$textrm{cm}^2$, 5.5${\times}10^5$cfu/$textrm{cm}^2$ and 1.8${\times}10^4$cfu/$textrm{cm}^2$, respectively, and of post-prechilling samples for the group A, B and C were 1.0${\times}10^4$cfu/$textrm{cm}^2$, 4.6${\times}10^5$cfu/$textrm{cm}^2$ and 2.5${\times}10^4$cfu/$textrm{cm}^2$, respectively. Initial total plate counts of post-transportation samples for the group D, E and F did not increased, as did the group A, B and C. From \"Normal sampling(II)\", initial total plate counts of post-slaughter, post-prechilling, post-transportation and post-2 days preservation samples were 7.3${\times}10^4$cfu/$textrm{cm}^2$, 9.6${\times}10^4$cfu/$textrm{cm}^2$, 2.0${\times}10^5$cfu/$textrm{cm}^2$ and 2.5${\times}10^5$cfu/$textrm{cm}^2$, respectively. From \"Clean sampling(III)\", initial total plate counts of post-slaughter, post-prechilling, post-transportation and post-2 days preservation samples were decreased to 7.0${\times}10^2$cfu/$textrm{cm}^2$, 7.5${\times}10^2$cfu/$textrm{cm}^2$, 8.5${\times}10^2$cfu/$textrm{cm}^2$ and 5.5${\times}10^3$cfu/$textrm{cm}^2$, respectively, compared with "Normal sampling(II)". No E. coli O157:H7, Staphylococcus aureus and Salmonella were detected at each sampling step. Consequently, a slaughter method like "Clean sampling(III)" showed a better sanitary effect to low total plate counts of 10$^2$∼10$^3$times, compared with "Normal sampling(II)". The one of contamination sources for raw pork meat was at a slaughtering step, and "Clean sampling" method may be considered as the one of sanitary standards.

  • PDF

Assessment of Immune Quality and Pathogen Contamination of Colostrums Collected from Colostrum Banks in Korea (초유은행에서 수거한 초유의 병원체 오염과 면역수준의 평가)

  • Kim, Won-Il;Park, Sang-Yul;Kim, Sang-Jin;Cho, Yong-Il;Hur, Tai-Young;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.223-229
    • /
    • 2013
  • Because colostrum is considered to be the sole source of passively acquired maternal antibodies for calves, newborn calves must consume colostrum to gain disease resistance during their early years of life. Storage of surplus colostrum from dairy cows right after calving and feeding newborn calves in deficiency of colostrum to assure adequate uptake of IgG for protection of the calf has been a common practice in the bovine production. In the current study, 35 colostrums were randomly collected from 3 colostrum banks located in different regions of Korea and monitored for general bacterial contamination and major bovine pathogens. Immunoglobulin concentrations and BVDV-specific antibodies were also determined to evaluate the immune quality of the colostrums. Moderate to severe bacterial contamination (up to 72,000,000 CFU/ml) was observed in most of the colostrums collected from colostrum banks. General immune quality of the colostrums was under the satisfactory level since most of the colostrums contained less than 50 g/L of IgG, which is the minimum concentration for good quality colostrums. Therefore, colostrum for colostrum bank should be collected at the first 2-3 post-partum milkings according to proper harvesting and handling procedures to guarantee the safety and quality of colostrum. In addition, it was recommended that colostrum should be heat-treated before frozen and stored in the bank because pasteurization at $63^{\circ}C$ for 30 min was very effective reducing the risk of disease transmission without causing significant degradation of immunoglobulins.

Antibiotic Resistant Microbial Contamination (Enterobacter cloacae) Derived from Egg Yolk and Frozen Semen Extender in Porcine In Vitro Fertilized Embryos

  • Kwak, Seong-Song;Jeong, Se-Heon;Jang, Seung-Hoon;Jeon, Yu-Byeol;Nam, Young-Hee;Biswas, Dibyendu;Lee, Wan-Kyu;Hyun, Sang-Hwan
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • The present study was to investigate the source of contamination during semen processing for in vitro uses. In the present study, frozen semen was prepared from liquid semen in our laboratory for in vitro fertilization (IVF) experiments due to lack of fresh semen. Antibiotics were added in the frozen semen extender (kanamycin and gentamicin) and in vitro culture (IVC) medium (gentamicin) for further inhibiting growth of microorganisms. Nevertheless, proliferations of microorganisms were observed in IVC culture drop during culturing of IVF embryos using frozen semen. Randomly 3 samples were taken from the liquid semen, frozen semen and egg yolk. Contaminated IVC medium, frozen-thawed semen, liquid semen and egg yolk were cultured in de Man, Rogosa and Sharpe (MRS) agar medium. Whitish colonies were detected in contaminated IVC drop, frozen-thawed semen samples and egg yolk but no colonies were formed in liquid semen samples. Gram-negative and rod-shaped identical bacteria were found in both frozen-thawed semen sample and contaminated IVC drop and egg yolk samples. Enterobacter cloacae were confirmed by API 20E kit according to manufacturer's instruction with identification value (% ID) 94.3% and T index 0.88. Antibiotic susceptibility tests were done according to Clinical and Laboratory Standards Institute (CLSI) by using ampicillin, amikacin, cephalothin, gentamicin, kanamycin, tetracycline, oxytetracycline, sulfamethoxazole trimethoprim, norfloxacin and ciprofloxacin test. Among them Enterobacter cloacae were resistant to ampicillin, amikacin, cephalothin, gentamicin, kanamycin but susceptible to tetracycline, oxytetracycline, sulfamethoxazole trimethoprim, norfloxacin and ciprofloxacin. From these findings it could be suggested that this contamination sources might be from egg yolk.

A geophysical survey result over a hydrocarbon contaminated site (물리탐사를 이용한 국내 유류오염지역 조사 사례)

  • Song Yoonho;Park Sam Gyu;Seol Soon Jn;Choi Seong-Jun;Chung Seung-Hwan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2001.09a
    • /
    • pp.122-140
    • /
    • 2001
  • We have applied the geophysical survey, mainly electric and electromagnetic (EM) methods, to a test site contaminated by hydrocarbon waste disposal and local spill. The multi-frequency, moving source & receiver EM survey along with ground penetrating radar (GPR) showed a fairly good performance in detection of buried metal pipes and objects. Magnetic survey measuring vertical and horizontal gradients were so sensitive to the small metallic objects spread over the surface that it's hard to discriminate the buried pipe. We chose electrical resistivity, EM and GPR survey to examine the soil contamination. Depth slices of resistivity distribution as the results of the inversion of resistivity and EM data coincided each other and closely matched the contaminated area determined by chemical analysis of the soil samples. GPR images did not show the reflection events related with contamination plume since there are no distinct spill in this site. We inferred the contamination using the penetration depth of the GPR energy, which could be used as auxiliary information to the resistivity and EM results. We summarized the applicability of each survey methods based on this results and proposed a desirable survey scheme for the determination of hydrocarbon contaminated site.

  • PDF

Using GIS Modeling to Assess the Distribution and Spatial Probability of Soil Contamination of Geologic Origin in Korea (GIS 모델링을 이용한 국내 지질 기원 토양오염의 분포 현황과 공간적 개연성 연구)

  • Jae-Jin Choi;Kyeong-Hun Cha;Gyo-Cheol Jeong;Jong-Tae Kim;Seong-Cheol Park
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.39-49
    • /
    • 2023
  • Soil contaminants measured and managed in Korea include those of geologic origin such as arsenic, cadmium, copper, lead, zinc, nickel, mercury, and fluoride. This study identifies the distribution of these contaminants using GIS modeling to analyze the spatial probability of soil contamination originating from geology. The modeling found that cadmium, copper, lead, nickel, and mercury often exceed the regulated standard by <1%. Concentrations of arsenic and zinc greatly exceeded the standard in the vicinity of mines and industrial complexes: mining and industry seemed to have substantial effects on the concentrations of these metals. Although fluoride was sampled at the lowest number of points, its frequency of exceeding the standard was the highest. No obvious source of artificial contamination has been identified, and fluoride's distribution characteristics showed continuity over a wide area, suggesting a strong correlation between geological characteristics and fluoride concentration. The highest frequencies of fluoride exceeding the standard were in Jurassic granite (40.00%) and Precambrian banded gneiss (34.12%). As these rocks contributed to the formation of soil through their weathering, high fluoride concentrations can be expected in soil in areas where these rocks are distributed.