• Title/Summary/Keyword: Contamination level

Search Result 1,020, Processing Time 0.032 seconds

A Comparison between the Contamination Level of Uniforms and the Nasal Staphylococcus aureus Colonization before and after the Clinical Practice of Nursing Students (간호대학생의 실습 전후 실습복 오염도 및 비강내 황색포도알균 집락정도 비교)

  • Park, Jin Hee;Shin, Gisoo;Kim, Jiyoung
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.2
    • /
    • pp.90-97
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the contamination level of uniforms with nasal colonization of Staphylococcus aureus before and after the clinical practice of nursing students. Methods: This study was a survey research, conducting microbial culture by smearing the front surface and the pockets of uniforms, and the nasal cavity both before and after clinical practice on 70 nursing students. For the analysis, descriptive statistics, chi-square test, paired t-test were used for statistical analysis using SPSS 19.0. Results: The contamination level of uniforms increased more significantly after clinical practice on the front surface (p=.008) and pockets (p=.031) than before clinical practice, and Staphylococcus aureus, and Enterobacter aerogenes were detected. Conclusion: Through the results above, it is believed that it is reasonable to do the laundering of clinical uniforms of nursing students once a week. Because it is possible to disseminate disease germs with the contamination of clinical practice uniforms in a hospital environment, it is necessary to offer education for the laundering of uniforms with appropriate management.

MICROBIOLOGICAL QUALITY OF BRAZILIAN LIPSTICKS AFTER NORMAL USE BY CONSUMERS

  • D.M.M. Pedroso;G.R. Dias;Gesztesi, J-L
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.524-526
    • /
    • 2003
  • Lipsticks are cosmetics which do not contain water and are usually preserved with parabens. When submitted to the Challenge Test, theses products did not reach the CTFA criteria, which means that microbiological contamination could occur before the end of its shelf life. The aim of this study was to evaluate the contamination level of 130 lipsticks after its use. Microorganisms were isolated from 14,6 % of the samples. However, only in two samples (1,5%) the contamination level exceeded the 100 CFU/g level, which means that, although the preservative system was not efficient to eliminate bacteria, the lack of free water was enough to prevent the microbial development. Total bacteria and fungi were determined by conventional methodology, according to CTFA Microbiological Guidelines. The microbes were then isolated and characterized as normal skin flora microorganisms. This suggest that products were contaminated by the constant application of lipsticks by consumers. This could lead to cross contamination when the same product is shared by several people. Extra care should be taken into account when this type of products are available to be tested by several consumers in demonstration displays.

  • PDF

Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics (치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사)

  • Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.472-480
    • /
    • 2017
  • The purpose of this study was to investigate Staphylococcus epidermidis contamination on hands of 20 dental hygienists and 140 equipment surface of 20 dental clinics in a local area, from July to August 2017. The degree of S. epidermidis contamination was measured using a hand plate and a rodac plate and then cultured at $35^{\circ}C$ for 24 hours. Based on hand plate criteria, hand contamination was classified into low, middle, and high groups. Analysis of the variance (ANOVA) of the contamination level of the hand parts of the group surface contamination level of the dental clinic equipment was descriptive statistics after clustering lock count. S. epidermidis contamination was moderate in 55% of the hands of dental hygienists. The area of contamination was 29.45 colony-forming units (CFU) on the palm, followed by the middle finger 7.8 CFU, ring finger 6.4 CFU, and thumb 6 CFU. Medical equipment surface contamination was showed that 3-way handle 4.45 CFU, computer mouse 3.37 CFU, mirror handle 1.60 CFU were higher than other areas. The group with high hand contamination had a high positive correlation with the S. epidermidis contamination of the hand. S. epidermidis contamination level was higher on hands than on the medical equipment surface contamination. Therefore, medical staff should recognize the importance of hand hygiene which should be practiced in the manner suggested by World Health Organization. In addition, the medical team needs to be responsible for performing infection control tasks, implementing infection management guidelines and providing systematic education on infectious disease management.

Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures (오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Jeong, Jeong Ho;Son, Jeong Ho;Park, Seok Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.

Effect of PVA Brush Contamination on Post-CMP Cleaning Performance (Post-CMP Cleaning에서 PVA 브러시 오염이 세정 효율에 미치는 영향)

  • Cho, Han-Chul;Yuh, Min-Jong;Kim, Suk-Joo;Jeong, Hae-Do
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.114-118
    • /
    • 2009
  • PVA (polyvinyl alcohol) brush cleaning method is a typical cleaning method for semiconductor cleaning process especially post-CMP cleaning. PVA brush contacts with the wafer surface and abrasive particle, generating the contact rotational torque of the brush, which is the removal mechanism. The brush rotational torque can overcome theoretically the adhesion force generated between the abrasive particle and wafer by zeta potential. However, after CMP (chemical mechanical polishing) process, many particles remained on the wafer because the brush was contaminated in previous post-CMP cleaning step. The abrasive particle on the brush redeposits to the wafer. The level of the brush contamination increased according to the cleaning run time. After cleaning the brush, the level of wafer contamination dramatically decreased. Therefore, the brush cleanliness effect on the cleaning performance and it is important for the brush to be maintained clearly.

A STUDY ON THE PREDICTION OF GROUNDWATER CONTAMINATION USING GIS (지하수오염 예측을 위한 GIS 활용연구)

  • Jo, SiBeom;Shon, HoWoong
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.2
    • /
    • pp.121-134
    • /
    • 2004
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters, such as structural lineament density and land-use, into conventional DRASTIC model, and to predict the potential of groundwater contamination using GIS in Hwanam 2 District, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament density affects to the behavior of groundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice-layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Groundwater contamination potential map was achieved as a final result by comparing modified DRASTIC potential and the amount of pollutant load logically. The result suggest the predictability of contamination potential in a specified area in the respects of hydrogeological aspect and water quality.

  • PDF

Significant Parameters for Assessing Soil Contaminant-Leaching to Groundwater and Determining Soil Sample Size in Field Survey

  • Jeong, Seung-Woo;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • For a given soil-contaminated site, a level of soil contamination is characterized and decisions on risk may be made from the risk assessment. The study evaluated critical design factors for the determination of sample size in the sampling design plan and the assessment of soil contaminant- leaching to groundwater. Two variables, the minimum relative detectable difference (T) and coefficient of variation (CV) were evaluated for the sample size determination. The minimum number of samples can be appropriately determined by CV under a T value greater than or equal to 0.2. Soil-contaminant leaching to groundwater was evaluated by using the Soil Screening Level equation of U.S. Environmental Protection Agency and the Risk Based Screening Level equation of American Society for Testing and Materials, with the same input parameters. The groundwater concentrations estimated from soil contaminant concentrations were significantly affected by the Darcy velocity of groundwater and the organic content of soil.

Strong Red Photoluminescence from Nano-porous Silicon Formed on Fe-Contaminated Silicon Substrate

  • Kim, Dong-Lyeul;Lee, Dong-Yul;Bae, In-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.5
    • /
    • pp.194-198
    • /
    • 2004
  • The influences of the deep-level concentration of p-type Si substrates on the optical properties of nano-porous silicon (PS) are investigated by deep level transient spectroscopy (DLTS) and photoluminescence (PL). Utilizing a Si substrate with Fe contaminations significantly enhanced the PL intensity of PS. All the PS samples formed on Fe-contaminated silicon substrates had stronger PL yield than that of reference PS without any intentional Fe contamination but the emission peak is not significantly changed. For the PS 1000 sample with Fe contamination of 1,000 ppb, the maximum PL intensity showed about ten times stronger PL than that of the reference PS sample. From PL and DLTS results, the PL efficiency strongly depends on the Fe-related trap concentration in Si substrates.

Source Identification of Nitrate contamination in Groundwater of an Agricultural Site, Jeungpyeong, Korea

  • 전성천;이강근;배광옥;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.63-66
    • /
    • 2003
  • This study applied a hydrogeological field survey and isotope investigation to identify source locations and delineate pathways of groundwater contamination by nitrogen compounds. The infiltration and recharge processes were analyzed with groundwater-level fluctuation data and oxygen-hydrogen stable isotope data. The groundwater flow pattern was investigated through groundwater flow modeling and spatial and temporal variation of oxygen isotope data. Based on the flow analysis and nitrogen isotope data, source types of nitrate contamination in groundwater are identified. Groundwater recharge largely occurs in spring and summer due to precipitation or irrigation water in rice fields. Based on oxygen isotope data and cross-correlation between precipitation and groundwater level changes, groundwater recharge was found to be mainly caused by irrigation in spring and by precipitation at other times. The groundwater flow velocity calculated by a time series of spatial correlations, 231 m/yr, is in good accordance with the linear velocity estimated from hydrogeologic data. Nitrate contamination sources are natural and fertilized soils as non-point sources, and septic and animal wastes as point sources. Seasonal loading and spatial distribution of nitrate sources are estimated by using oxygen and nitrogen isotopic data.

  • PDF

Analysis of Sediment Contamination Levels in the Giheung Reservoir (기흥저수지 퇴적물에 대한 오염도 분석)

  • Oh, Kyoung-Hee;Kim, Sung-Jin;Cho, Young-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.26-32
    • /
    • 2018
  • In order to analyze the effects of sediment on the occurrence of algal bloom on the Giheung Reservoir, the contamination levels of sediments were evaluated. The concentrations of various organic compounds (ignition loss), as well as the total nitrogen, total phosphorus, and heavy metals (Zn, Cr, Co, Ni, Pb, As, Hg, Cd) were analyzed in the sediments taken at eighteen sites of the reservoir. The concentrations of ignition loss and total nitrogen tended to increase from upstream to downstream, and ranged from 4.38 to 12.93% and 2,153 to 4,723 mg/kg, respectively. Heavy metals were in the order of Zn>Cr>Co>Ni>Pb>As>Hg, and the contamination level of the heavy metals was not high as a whole. The concentrations of the total phosphorus were in the range of 765 ~ 3,238 mg/kg, which exceeded the contamination level of the "Sediment Quality Assessment Guideline of River and Lake Sediment (Rule No. 2015-687 of the National Institute of Environmental Research, Korea)" at two upstream sites, four downstream sites, and all downstream sites. These results indicated that the pollution level of the total phosphorus, which is the main factor related to algal bloom, was found to be serious. Therefore, it is necessary to establish a countermeasure for sediment management in order to control the algal bloom which occurs periodically in the reservoir.