• Title/Summary/Keyword: Contamination factor

Search Result 334, Processing Time 0.025 seconds

A Study on Mechanism about Contaminant Accumulation of Insulator Surface (애자표면의 오손물 누적에 관한 메커니즘 연구)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.8 no.2
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

Assessment of Worker's Diisocyanates Skin Exposure at Polyurethane Foam Manufacturing Companies (우레탄 폼 제조 사업장 작업자의 디이소시아네이트 피부노출 평가)

  • Jeong, Jee Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Objectives: Skin exposure to diisocyanates may be an important risk factor for respiratory sensitization to leading asthma. However little is known about the extent of worker's diisocyanates skin exposure and the effectiveness of personal protective equipments in polyurethane foam manufacturing companies. This study provides data on diisocyanates skin exposure, surface diisiocyantes contamination of foams and the effectiveness of personal protective gloves in five polyurethane foam manufacturing companies. Materials and methods Colorimetric SWYPE pads are used for the determination of diisocyanates on surfaces of workers skin and polyurethanes foams. Results: The forearms, necks and faces of workers in polyurethane foam manufacturing companies were found to be contaminated with diisocyanates. Heavy contamination with uncured diisocyanates at large block foams surfaces were found. Personal gloves of workers for skin protection showed significant penetrations by diisocyanates. Conclusions: We found that all workers in polyurethane foam manufacturing companies could be exposed to diisocyanates by skin exposure. Also further researches which would better quantify skin exposure are needed.

A Study on Effect of Atmospheric Gas on the Surface Cleanliness in the Batch Annealing Furnace (BAF풀림시 분위기가스가 표면 청정도에 미치는 영향에 관한 연구)

  • Yoon, Soon Hyun;Kim, Moon Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.2
    • /
    • pp.159-167
    • /
    • 1996
  • The effect of atmospheric gas on the surface cleanliness in the batch annealing furnace(BAF) is presented. It is very important to improve the surface cleanliness to investigate the surface defects such as carbon contamination, smudge and yellow color phenomenon on the surface of steel sheet. In order to study the occurrence of surface defects of steel sheet, the annealing operations were carried out in the H2 BAF with 75% hydrogen and conventional BAF with 4% hydrogen. The hydrogen is important factor that affect the energy saving in the entire annealing cycle and the surface cleanliness. In the conventional BAF, it shows that to protect the yellow color phenomenon the proper finish temperature is $80^{\circ}C$ and in the smudge sample the oxidized thickness has the depth of $120{\AA}$.

  • PDF

Heavy Metal Distribution in Soils from the Maehyang-ri Inland Shooting Range Area (매향리 내륙 사격장 토양의 중금속 오염 분포)

  • Lee, Jun-Ho;Park, Kap-Song
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.407-414
    • /
    • 2008
  • This study was conducted to evaluate the heavy metal contamination in the soils of Maehyang-ri inland shooting range area. The texture of the Maehyang-ri inland shooting range soil was sandy. Extraction of heavy metals reached quasi-equilibrium within 6 hours using shaking with 0.1 N HCl. 95% and 94% of extraction efficiency was observed for Cu and Pb in the Maehyang-ri shooting range soils, respectively. And Cu and Pb contamination of level of the T-1 region soil was $114.4{\pm}5.7mg/kg$ and $362.3{\pm}20.5mg/kg$. This may be due to the effects of mineralogical factor, soil particle size and un-residual fractions such as exchangeable, carbonate, Fe-Mn oxide and organic+sulfide.

Antibiotic and Heavy Metal Resistance of Coliform Bacteria Isolated from Mineral Water (약수에서 分離한 大腸菌群의 일부 중금속 및 抗生劑耐性에 관한 연구)

  • Jeong, Jee-Yeon;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.63-73
    • /
    • 1989
  • The purposes of this study were to find out the heavy metal and antibiotic resistant coliform bacteria from mineral water and the resistant factors. For the experiment, mineral water samples were taken from A area and B area during the period from march to July, 1988. The results of the experiment were as follows 1. From mineral water, eleven resistant coliforms and one susceptible coliform were isolated. 2. All resistant isolates harbored diverse plasmids of ranged ca. 14-54kb. 3. Susceptible coliform harbored a only plasmid of ca. 2.8 kb. 4. All resistant isolates harbored common size of plasmid of ca. 14kb. 5. As a result of the transformation and agarose gel electrophoresis experiments, resistant factor was R-plasmid. In conclusion, It is suggested that heavy metal contamination of mineral water is the selective pressure for the plasmid encoding the tolerance. Heavy metal resistance, in some case, is present with antibiotic resistance. Therefore, heavy metal contamination of mineral water induces antibiotic resistant bacteria.

  • PDF

Electrical Properties of Outdoor Insulator with the Difference of Contaminated Condition (오손조건에 따른 옥외절연물의 전기적 특성)

  • 최남호;구경완;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.467-470
    • /
    • 2000
  • This paper present the result of the investigation, electric properties of outdoor insulators with the difference of contaminated condition. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. A mini-fog chamber with transparent acryl and the standard contamination solution with kaoline was used. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current and the ambient condition, such as relative humidity and temperature, a DAS system was developed with LabView. From the result, we could know the influence of contaminated condition. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

The Electric Properties of Insulators Due to Non-soluble Contaminant (불용성 오손물에 의한 절연물의 전기적 특성에 관한 연구)

  • 최남호;국연호;조성인;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.691-695
    • /
    • 2000
  • This paper present the result of the investigation, the electric properties of insulators due to non-soluble contamination. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. Though the non-soluble do not distribute on conductivity of contaminant layer, that has the hygroscopic property. For this study, we make a mini-fog chamber with transparent acryl and the kaoline was used for non-soluble contaminant. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current a DAS system was developed with LabView. With the result, we could know the influence of non-soluble content and the relationship between NSDD and ESDD.

  • PDF

Analyses of Leakage Current of Transmission Insulator as a Function of Environmental Condition (환경에 따른 송전용 애자의 누설전류 분석)

  • Choi, In-Hyuk;Lee, Dong-Il;Kim, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1166-1170
    • /
    • 2004
  • The leakage currents of transmission insulator were investigated as a function of environmental conditions, such as temperature, humidity, and rainfall. The insulators were artificially contaminated with insoluble yellow soil and kaolin which helped salt to stick on the surface of insulator. The insulators contaminated with the grade of B, C, and D were installed in the KoChang Testing Center. The leakage currents were measured and compared with non-contaminated insulators. The results indicated that the most important factor affecting leakage current was humidity. After heavy rain, the artificially contaminated salt was dissolved, resulting in similar characteristics between with and without contamination

  • PDF

A Study on Groundwater Contamination Potential of Pyungtaek-Gun Area, Kyunggi-Do Using GIS (GIS를 이용한 경기도 평택군 지역의 지하수 오염 가능성 평가 연구)

  • 조시범;민경덕;우남칠;이사로
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.87-94
    • /
    • 1999
  • This study is providing Modified DRASTIC Model to which lineament density and land use are added as additional factors using geographic infomation system(GIS). and then to evaluate groundwater contamination potential of Pyungtek-Gun area in Kyunggi-Do. In this study. the reason for using additional factors is because. in case of lineament density. when we consider that most of aquifer is bedrock aquifer in hydrogeologic environment of the Korea, lineament is very important to flow of groundwater and contamination material. and because land use can reflect indirectly impact of point or non_point source in study area. For statistical analysis. vector coverage per each factor is converted to grid layer and after each correlation coefficient between factors, covariance, variance. eigenvalue and eigenvector by principal component analysis of 3 direction. are calculated. correlation between factors is analyzed. Also after correlation coefficients between general DRASTIC layer and rated lineament density layer and between general DRASTIC layer and rated land use layer are calculated. final modified DRASTIC Model is constructed by using them with each weighting. when modified DRASTIC Model was compared with general DRASTIC Model, comtamination potential in modified DRASTIC Model is fairly detailed and consequently. vulnerable area which has high contamination potential could be presented concretly.

  • PDF

Introduction on the Contamination Design Standard(Revision Proposal) of 345kV/154kV Transmission System in KEPCO (345kV/154kV 직접접지계 송전설비의 내오손 설계기준(안) 해설)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Lee, O.B.;Shin, T.W.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.262-264
    • /
    • 2002
  • This paper shows the design standard of KEPCO on the contamination design for 345 kV and 154 kV transmission tower. Up to now, because the design standard of KEPCO on the insulation design contains 154 kV transmission system only, we had investigated the 343 kV system for the revision of design standard, with respect to the contamination design, we have used the same design philosophy which were adopted to the 765 kV transmission tower. In order to determine the number of insulator discs, we had investigated the withstand voltage of discs according to the level of ESDD(Equivalent Salt Deposit Density) and kinds of disc types. The TOV(Power Frequency Temporary Overvoltage) were estimated by EMTP(Electromagnetic Transient Program) for both 154 kV and 345 kV transmission system. The overvoltage level was appeared 1.35 p.u. between phase to ground for both 154 kV and 345 kV transmission system, but finally this factor was not applied to the design standard considering current design standard and economic point of view. With regard to classification of contamination area of 345 kV transmission system, we added the clean area which was not specified in the current design practise.

  • PDF