• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.038 seconds

Modelling for Dilution Ventilation of Indoor Contamination Materials (실내 오염물질의 희석환기에관한 모델링)

  • Sim, Seong-Hun;Jo, Sang-Jun;Kim, Gwang-Yeong
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.31-42
    • /
    • 1989
  • To investigate design factors of dilution ventilation system, numerical analysis of air contamination flow and concentration distribution have been made, by using the low Reynolds number turbulent model. And flow visualization and measurement of particle concentration for that model also have been made. By comparing of these results we have secured the essential data for the adequate counterplan of dilution ventilation system. The results of this study are as follows: 1) Inlet should be located near the wall for the prevention of the formation of the recircula¬tion zone. 2) In case of natural exhaust, air contamination flow is driven to the far outlet from the inlet. 3) It is favorable for dilution to make turbuence as much as possible.

  • PDF

Study on the Sensor Development for Liquid Contamination during Delivery (이송 중 액체오염 검출센서 개발에 관한 연구)

  • Jeong, Yi Ha;Kim, Byung Han;Hong, Joo-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.70-73
    • /
    • 2016
  • Previously proposed contamination detecting sensor was revisited for the investigation of the liquid tendency. Experiments revealed different output voltages for several kinds of liquid input, but showed same values for various flow rates of each liquid. The transmittance of the liquid was measured, and it is well correlated with the voltages. Linearity in values and the compensation of the sensor to sensor deviation were tried to obtain. And, long term test was performed as attached at the manufacturing equipment in the field.

A Study of Environmental Sanitation on the Well in SeouI (도시 영세민 정호의 위생학적 조사)

  • 김영의;최덕일;이상남;최용어
    • Journal of Environmental Health Sciences
    • /
    • v.1 no.1
    • /
    • pp.36-40
    • /
    • 1974
  • A Study on environmental sanitation on the well in Seoul was made to find the degree of Physio-chemical and Bacterial contamination. For this study 30 wells were located at Nokbundong Hongjaidong and Hongeundong from September 13 to 22 1971. As the results of this study the following conclusions were obtained. 1) Seventy per cent were being utilizing by from 10 to 50 households per well. 2) About 93 per cent of the wells were found to be dug out in Rocks. 3) Eighty-three per cent of the wells surveyed in the slums had a depth of water shorter than 20 cm. 4) The degree of Total Viable Bacteria contamination were high point $15{\times}10^2$ low point 13 and coliform bacteria were high point $79{\times}10^1$ low point 1 organism per ml. 5) Only 4 wells (13.3%) were able to drink but 26 wells (86.7%) were not drinking by physio-chemical and Bacterial contamination.

  • PDF

A Pathway Analysis Model for Determining Acceptable Levels of Contamination of Radionuclides in Soil (토양의 방사능오염 허용기준치 설정을 위한 피폭경로모델)

  • Lee, Chang-Woo;Kim, Kug-Chan;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.67-74
    • /
    • 1990
  • A methodology for calculating acceptable levels of contamination of radionuclides in soil for unrestricted use was described. Pathways of exposure include direct radiation from ground surfaces, ingestion of contaminated food and inhalation of resuspended radionuclides. Results calculated using site-specific data for Korean environment were discussed and compared with those estimated by other guidelines.

  • PDF

Effect of Roadside Soil and Vegetation with Lead and Zine by Motor Vehicles (자동차 매연중의 미량금속이 토양 및 식물체에 미치는 영향)

  • 강상준
    • Journal of Plant Biology
    • /
    • v.15 no.3
    • /
    • pp.9-13
    • /
    • 1972
  • This report deals with lead and zinc contamination of roadside soil and plants caused by motor vehicles as a function of distance from the road edge. The concentrations of Pb and Zn in roadside soil and plant samples from several locations decrease regularly with increasing distance from traffic. Soil samples up to 24m distance from the road edge are contaminated with more than 12.99ppm lead, and 13.40ppm zinc. The decrease in Pb and Zn contamination with increasing distance from the road is characteristically curvilinear; the relative coefficiency of Pb and Zn with distance is -0.69, -0.48, respectively. The average contents of Pb and Zn in plants are 21.5ppm and 30.00ppm. It is suggested that the contamination is related to the composition of gasoline, motor oil and to roadside of the residues of this metals.

  • PDF

Downward and Upward Air Flow Effects on Fume Particle Dispersion in Laser Line Cutting of Optical Plastic Films

  • Kim, Kyoungjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.37-44
    • /
    • 2020
  • In improving laser cutting of optical plastic films for mass production of optoelectronics display units, it is important to understand particle contamination over optical film surface due to fume particle generation and dispersion. This numerical study investigates the effects of downward and upward air flow motions on fume particle dispersion around laser cut line. The simulations employ random particle sampling of up to one million fume particles by probabilistic distributions of particle size, ejection velocity and angle, and fume particle dispersion and surface landing are predicted using Basset-Boussinesq-Oseen model of low Reynolds number flows. The numerical results show that downward air flow scatters fume particles of a certain size range farther away from laser cut line and aggravate surface contamination. However, upward air flow pushes fume particles of this size range back toward laser cut line or sucks them up with rising air motion, thus significantly alleviating surface contamination.

Electrical Impedance Change due to Contamination at the Contact Interface of Connectors for Automobile Crank Shaft Position Sensor

  • Kim, Young-Tae;Sung, In-Ha;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.2
    • /
    • pp.46-52
    • /
    • 2004
  • Numerous connectors are used in automobiles for transmission of electrical signals across various electro-mechanical components. The connectors must operate with high reliability in order to minimize failures due to signal degradation. In this work, the effects of contamination at the contact interface of connectors used fur automobile crankshaft position sensor on the impedance change were investigated. An experimental set-up was built to simulate the electrical signal transmitted from the sensor to the engine control unit through a connector. Output from the connector was investigated using connectors contaminated with engine block residues and water droplets. It was found that slight contamination of the connectors could lead to significant signal degradation which can lead to engine failure. Also, the effect of water in the connector altered the signal severely. However, the signal gradually regained the original state as the water evaporated from the interface.

Flashover Failure of Polymer Insulator in Distribution Lines (배전용 폴리머애자의 섬락고장)

  • 한재홍;이병성;김찬영;윤태상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.767-770
    • /
    • 2000
  • This study was investigated for searching a cause of flashover failure of polymer insulator and preparing countermeasures. Hydrophobicity, microstructure and chemical structural change of polymer weathershed were studied by polymer characterization methods. In addition, the electrical properties such as power frequency dry flashover voltage/impulse voltage tests, contamination characteristics were carried out. The hydrophobicity of polymer weathershed was decreased significantly and cracks were observed on the surface. Also, the electrical characteristics did not satisfy the KEPCO specification. The failed polymer insulators showed the more leakage current than 4 years service-aged ones. From the result, it can be concluded that the flashover failure of polymer insulator was attributed to the surface aging and severe contamination.

  • PDF

Possibilities in using Enterococcus spp. in Microbial Source Tracking (Enterococcus spp. 를 이용한 미생물 오염 추적 기술)

  • Unno, Tatsuya;Hur, Hor-Gil
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.827-830
    • /
    • 2008
  • Enterococcus is a fecal indicator bacterium and often used to indicate fecal contamination in the environment. Carbohydrates fermentation patterns of Enterococcus isolates were investigated as a way to differentiate the source of fecal contamination. Total 1826 Enterococcus isolates were obtained from cows, pigs, chickens, ducks, and humans in two geographically different locations. Distributions of carbohydrate fermentation patterns showed discrepancies among sources. This study suggest that the possibility of the use of Enterococcus in microbial source tracking.

  • PDF

A Study of Unit Commitment Considering Environmental Effects by Fuel Substitution

  • Lee, Buhm;Kim, Yong-Ha;Park, Nam-Sup
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • This paper proposes a new generation scheduling algorithm which can consider total quantity of contamination and energy limits based on Lagrangian Relaxation. First, we formulate a Lagrangian function which consider quantity of contamination including substitution of fuel, and quantity of fuel. Second, we developed Multi-state S.U.D.P. which can treat multiple fuels. Third, we propose an effective generation scheduling algorithm including Multi-state S.U.D.P.. As a results, unit commitment and generating power can be obtained to meet the environmental and fuel constraints with fuel substitution. By applying it to the test system, effectiveness of the method is verified.